Document LpxmerxQbrBb51ox8E3wNMKDb

C.H I 14S-2 INTERNAL CORRESPONDENCE CHEMICALS AND PLASTICS Dhbkm Car H Paul W. McDaniel Medical Dept. DOC NYC L. F. Crow J. L. Myers J. A. Riddle p. o. box k. king cnv. California 93930 Dot* January 3, 1968 OHpfaofleg 0*pL Aumritg Utfr dote 1 Dear Mr. McDaniel: Enclosed are dust particle counts taken on December 29, 1967. It should be noted that the entire bagging area has been enclosed and is a "NO SMOKING OR EATING" area. All personnel working in this area are required to wear respirators. Weather: Gentle wind from the south west, fair, 55 high purity open being bagged. There are still plans for reduction of dust in this area. SAMPLE 59 Ragging room COMMENT Large quantities of visible dust Doors closed, personnel wearing respirators. mpfcf 11.7 47 Bagging room 24 Lab Same as above Routine work being performed, fume hoods in operation 12.5 2.3 26 Lab 93 Rock Fiber Circuit 69 Refiner Circuit 65 Office Building Same as above Normal Operation Normal Operation These were taken due to south wind blowing 3.0 3.7 3.8 2.1 71 Maintenance Building 68 North Parking Lot Very truly yours. Same as above Dryer exhaust in this direction 2.1 4.4 D. S. Kaoens UCC 004970a V I-'IV O r If I M9-2 I INTERNAL CORRESPONDENCE- CHEMICALS AND PLASTICS PMdoa t-rnffrt P. w McDaniel Medical Dept. 4-202 270 Park Avenue New York r-rr- P. D. Dexter L. F. Crow P. 0. BOX K, KING CITY, CALIFORNIA 93930 Dai. December 13, 1968 Oftglmitiag Dfrt. Aafmriflf hUmt data Mj.4 Dear Paul: I'm sorry we didn't get a chance to talk about your dust count results before you left. Enclosed Is a set Kamens took yesterday. They are generally within the' present limit except In the bagging area, reflecting the fact that ve discontinued dumping floor sweepings off the truck dock. Effective 12/11/68, floor sweepings will be wet down before they are taken out of the bagging area. This should eliminate this source of airborne dust. We will require respirators on personnel hand stacking at the end of the bag conveyor, based on the test results. We will proceed to design and install a wet system for returning cleanup material from the bagging area to the head end of the circuit. This should reduce dust counts throughout the plant. Please let me know if you have any other recommendations for improvement. J. A. Riddle JAR/c g end. \ UCC 004970c