Document Lpn84GYjXD6Nq0OdDVZrazdab

Boilers, Oil Burning General Electric Company AIR CONDITIONING PRODUCTS Air Conditioning Department, 570 Lexington Ave., New York, N. Y. For Steam, Hot Water, Vapor, or Warm Air Heating Systems, General Electric Offers a complete line of Air Conditioning Equipment consisting of: The G-E Oil Furnace (2 sizes) Type LA4 and LA5. The G-E Winter Air Conditioner for Warm Air Systems (Type AA3)--See Page 630. The G-E Winter Air Conditioner for Radiator Systems (Type AC1)--See Page 630. The G-E Room Air Conditioner (Type ADI and AD2)--See Page 630. The Furnace is ideally suited for the heating of large quantities of water for commercial purposes. It may be used for special applications requiring up to 14 lb. steam pressure. The G-E Oil Furnace uses a new principle of atomization and combustion. Oil, and atomizing air, under low pressure, meet in collision within the nozzle tip and emulsify: expansion of the air, as the mix ture emerges from the nozzle, shatters the oil into an "oil fog." This atomized oil is blown from the nozzle toward the bottom of the furnace, where it meets the supply of secondary air introduced at the bottom, resulting in progressive, quiet and com plete combustion of the oil. Design Features 1. All rotating parts on one shaft, automatically oiled, no belts, no packing. 2. Heavy welded-steel boiler, with combustion C spaces entirely surrounded by water. 3. Down-draft opera tion, with chimney at the bottom, results in high efficiency. 4. Built-in domestic hot water heating coil. 5. Sub-atmospheric pressure within unit pre vents escape of odors. 6. Large oil orifice, non clogging; non-dripping nozzle tip protected from heat of flame. 7. Oil viscosity com pensation. 8. Temperature-resist ing metal parts. 9. Electric ignition during starting cycle only. 10. All controls built-in, including four-second de tector with self-checking contacts, water tempera ture or steam pressure limit, low water cut-off (steam), expansion relief door with electric cut-out, domestic hot water temperature switch, synchro nous motor-driven primary control, and electric clock thermal control with separate day and night settings. 11. Burner head, motor compressor, and controls separately and quickly removable and replaceable. 12. Designed, manufactured and guaranteed by a single responsible manufacturer--General Electric. Specifications TYPE LA4 Output--133,000 B.t.u. per hour (555 sq. ft. equivalent direct steam radiation). Water Capacity--47.5 gal. (full), 31.6 gal. (to water line). Heating Surface--30.5 sq. ft.--93.3% water backed. Piping Connections--3 in. outlet, two in. returns. Electrical Input--195 watts at max. oil rate for steam systems, 285 watts with water circulator for water systems. Dimensions--5 ft, 3 in. high, 35 in. wide, 42 in. deep. Weight--050 pounds com- ietely assembled, without TMwater. TYPE LA5 Output -- 275,000 B. t. u. per hour (1145 sq. ft. equiva lent direct steam radiation). Water Capacity--76.7 gal(full), 64-3 gal. (to water line). Heating Surface--53.5 sq. ft.--95% water backed. Piping Connections--4 in. outlet, two 2H in- returns. Electrical Input--200 watts at max. oil rate for steam system, 290 watts with water circulator for hot water systems. Dimensions--5 ft., 7 high; 37 wide; 51 in. deep. Weight--1660 lbs. completely assembled, with out water. 666 Burners, Oil Williams Oil-O-Matic Heating Corporation Manufacturers of Automatic and Manually Controlled Fuel Oil Burners 0n.$$nc Bloomington, 111. Service to Architects and Builders Bloomington, III. Chicago, 185 North Michigan Avenue 0n$jiC New York. Graybar Building Williams Oil-O-Matic offers a complete line of oil heating equip Model No. SPECIFICATIONS Length, Width. In. In. Height, In. HP. Gals. Fuel Oil per RTJVf. Operating Hr. Min. Max. ment--covering all heating and hot water needs. Also boilerburner units, heavy duty range burners and unit heaters. Latter used with water heaters where both hot water and heat are required. %Model K-1.5 Model KB (1200). 25 29 15 16 22 1/8 1750 20 1/6 1150 Vi P/x Model KB(I800) Model J(I200) Model J (1600) Model JJ . Model K (1200) Model K (1800) 29 45 45 50 34 34 18 20 23 33 28 28 20 1/4 1750 5 25 1/4 1150 4 10 25 1/2 1750 8 15 22 1 1750 12 25. 21 1/6 1150 21 1/4 1750 Wl 2Vi 3 5 WATER HEATERS Wha* WHBf WHCt 48 23 28 m 1750 75 23 23 1/8 1750 68 29 34 1/8 1750 i.(5 IV. Output.- 90* rise, 60 gallons per hour. {Output: 90 rise, 120 gallons per hour. {Output: 90 rise, 210 gallons per hour; the In case motor. odd frequency motors are used, the maximum TThke.-m--i-n--i-m--u--m----c-a'--pacity -r-e-m---a"ins---t-h-e---f-a--m--e- . capacity of the Model K must burner will be reduced be substituted for KB in prop for odi irtion to the r.p.m. of currents and export How to Decide Size of Burner For low pressure domestic boiler, 1 gal. of fuel oil per hour (L40,000 B.t.u.'s) is re quired for ap proximately: 300 sq. ft. of steam radia tion or its equivalent. Model K-1.5 Od-O-Malic 480 sq. ft. of hot water radiation or its equivalent. 70,000 B.t.u.'s when using hot air furnace ratings. 24 sq. ft. steam boiler heating surface (or 2.2 hp.). 1 sq. ft. of grate surface with combustion space 3 ft. high or its equivalent. For detail dat3, see Oil-O-Matic Instal lation and Service Manual. Domestic Hot Water Supply Three water heater models cover the domestic and commercial water heating fields. Entire apparatus-including genuine Oil-O-Matic oil burner, combustion cham ber, water tank, and all automatic controls --now combined in a single neat and compact unit. Refer to specifications for dimensions and output capacities of all models--WHA, WHB, andWHC. .. Wide variety of sizes for steam or hot Water. Write for details. . Underwriters' Listing Oi1-O- Matic burn ers are listed as standard by National Board of Fire Underwriters to bum oils conforming to A. P. 1. standard specifications for Nos. 1, 2, 3, and 4, also Hoi Water Supply Unit Pacific Coast Disel. Each burner carries Underwriters' label. Also approved by all important codes and governing bodies. Range Burners New type Oil-O-Matic range burner, for heavy duty ranges, brings oil heat econo my to restaurant,, hotel, hospital, steam ship, dining car, resort and club. No priming, no heat generating, no matches, no wicks required; a single lever controls everything. Boiler-Burner Units Engineering Service A complete line of welded steel and also cast-iron sectional Boiler-Burner Units. Engineering service is available to architects--see A. I, A., File No. 30-GL. 667