Document Lpj1g9mqok1eqnrqVj3pvavJb

Controls and Instruments GENERAL 801 ALIEN AVENUE CONTROLS MaHufrieherteM, Automatic P*toUuAef ^lemp&iatune., Jleoel & Qlcua Qoubiok FACTORY BRANCHES: BALTIMORE (5), BIRMINGHAM (3), BOSTON (16). BUFFALO (3) CHICAnn (5), CINCINNATI (2LCLEVELAND (15), DALLAS (2), DENVER (4), DETROIT (21). WASHING TON (6), GLENDALE (1), HOUSTON (6). KANSAS CITY (2), MINNEAPOLIS (2), NEW YORK nn PHILADELPHIA (23), PITTSBURGH (22), ST. LOUIS (3), SAN FRANCISCO (7). NEWARK rtV SEATTLE (1), TULSA (6). DISTRIBUTORS IN PRINCIPAL CITIES. w THERMOSTATS Compact, snap-action, T-70 Metrotherm Thermostat. Functional beauty for accurate, remote control of desired tem perature. Extends only J'g in. from wall. Streamlined stain less cover, sensitive to slightest BX-69 GAS ACTUATED PACKAGE SETS Type T-70 temperature change, ivory plas tic base. MAGNETIC GAS VALVES Versatile, two-wire, straight magnetic cur rent-failure valve. Pack less. Insures tight shut off indefinitely. Hum less. Size range, A in. to 6 in. I.P.S. Operat ing pressures up to 5 lb. Voltages and frequen cies A.C. or D.C. Quiet, positive, trouble-free. Type KSB Available in explosionproof housing. SLOW OPENING GAS VALVES New combustion con trol afforded by these diaphragm- controlled gas valves. Governor regulates fuel supply to burner in direct ratio to steam pres sure, eliminating Type B-66-0 hunting aspect. Low fire adjustment pre vents main valve or gas flow from re ducing below adjustable set minimum. Available 1 in. to 6 in. I.P.S. MAGNETIC VALVES Provides six times more f)Ower than ordinary so- enoid valves. Controls air, gas, water, light, heavy oils, steam. Pos itive opening, complete i shut-off, packless, hum- free. Available for any Type K-IO voltage, A.C. or D.C., in sizes up to IM in. I.P.S., port sizes up to % in. K-20 Series is de signed for applications where single nee dle port sizes provide sufficient flow ca pacity. No outside current required. Operates on all types of gases. Safe, quiet, depend able. For all gas-heating appliances. Set consists of a PG-9 500 millivolt pilot generator, a B-60 gas control valve, a T-70 snap-action thermostat, thermo static cable and vent tubing. Everything needed in convenient package for remote gas control. *hi-g MAGNETIC VALVES Designed for positive operation on aircraft, trucks, tractors, tanks, graders, ships, and other moving equipment. Handle all fluids, vapors and gases on anything that rolls, floats or flies at pressures up to 3000 lb or more. Packless, two- wire, current - failure type, available normally open, normally closed for intermittent or continuous duty. *Trade Mark--"hi-g" indicates positive ability to function in any position, regardless of vibration, change of motion or acceleration REFRIGERANT CONTROLS Magnetic piloted, two wire, current failure, high pressure, packless. Handle large capacities with minimum pressure drop and loss. Tight shut-off. Operates on wide variety of fluids and gases. Type K-16 1282 General Controls Controls and Instruments Type Q-l-7 HYDRAMOTOR VALVES Simplify valve control in stallations. Two-wire, cur rent failure, electric - hy draulic operation. Ample motor - driven power, slow opening and closing move ment. Operator drives against a spring in one di rection; power failure or opening of circuit causes spring to operate in other direction. THERMAL EXPANSION VALVES Type V-2)0 with new se lective capacity car tridge provides instant sizing adjustment. Only one valve required for full capacity range in each body size at all back pressure or suction temperature ranges. For Freon, Methyl Chloride or Sulphur Dioxide. GAS FUEL GOVERNORS MANUAL RESET VALVES Equipped with manuallyreset electromagneticallyheld valve operator. Cur. rent flowing to operator f permits manual opening by turning valve wheel at side. Current failure releases op erator allowing valve to close. Trip-free mechanism cannot be opened under unsafe conditions. Once closed j valve is re-opened manually because applying TypeV-no current has no-effect. STRAINERS Actual tests prove impor tance of strainers in prolong ing operating life and reduc ing leakage of flow controls. SY-6 Series STRAINERS come in 8 types; meshes 3/16 _ in. diam.to 120-per-inch. Type 5i-6 THERMOPILOT (Valve Model) Manually - reset, electromagneticallyheld-o'penvalve with current generated by -single couple subject to heat' of pilot flame. Available % in. to VA in. I.P.S. 'Type MRS THERMOPILOTS Proven principles of op eration insure "dependa bility. Flame applied to thermocouple maintains electrical contact, allow ing electrical gas valve to open. When flame fails, Thermopilot opens cir cuit to main gas valve. Flexible, armored, asbes Type A-100 tos-covered cable detach able from relay. 2 or 3- wire control. Electrical rating, 2 amp., 24 volt; 1 amp., 115 volt; 0.5 mp., 230 volt. Throttle gas lines according to boiler pressure applied to diaphragm. Ball bearing thrust adjustment, ground and polished non-corrosive stems, low friction packing gland seal, multiple calibrat ed springs, high lift for maxi mum capacity. Suitable for butane, natural or manufac tured gas. Available $ in. to 3 in., I.P.S. Type V-tS-6 RELAYS AND TRANSFORMERS Type RS-100 handles sin gle phase motor loads up to 1 hp or heating loads up i to 1.1 kw. Combines dou-1 ble-break relay and inte-1 gral transformer. Nor-1 mally open; large double break contacts. Two-wire I control circuit; maximum I holding current 0.4 amps. ' Furnished with A in. con duit connections and low Type RS-100 voltage outlet. A.C. only. FAN AND LIMIT CONTROL Combination Fan and Safety Limit Control in corporates two separate ' switch units, one acting as a fan control; the other for safety limit operation. Each switch makes and breaks its own circuit inde pendently. External ad- Type L-54 justing knob on fan switch may be turned to "fan summer" position for manual control of fan for summer ventilation. LOW PRESSURE GAS REGULATORS New V-300 Series are reliable, trouble-free valves with high cap acity, close regula tion, yet small and compact. Regulator size range" from Y% to 2 in. I.P.S. Internal Type Y-500 parts, corrosion-resistant. Cast iron reg ulator bodies,long lifecalibratedsprings, properly fitted all-metal valves. 1283