CHAPTER 9
!\
1952 Guide
as would be expected in warmer weather.; Fig. 8 represents the results of
one such survey.13 When water vapor is allowed to enter a wall and condensation occurs on
its outer cold elements, it appears as frost or liquid: If the weather temperature rises frequently, frost melts and becoming liquid, is likely to penetrate capillary materials like wood, or run down when the surface is non-absorbing or is already saturated with water. In weather that is con tinuously cold for a long period, the frost may build back into a cavity or fibrous insulation and, when it reaches a warmer plane, will run to lower, cooler levels where it forms a mass .of ice. Water seepage to the weather side may occur harmlessly in masonry walls when the weather is above freezing but water seepage into the building must obviously be avoided. In typical frame construction with wood sheathing which has large water absorbing capacity, seepage is rare and occurs only after a long period of steady cold weather. More generally, moisture accumulates in wood sheathing and siding through the colder months and reaches a peak in late
Heat Transmission Coefficients of Building Materials
207
wall structure permits. Ventilation, as discussed later in this chapter, is an important correction factor in these cases.
Insulation in a wall or roof reduces-heat loss and lowers the temperature ' of the outer elements of the'structure, thus increasing the possibility of condensation if the vapor path to the cold surface is not blocked. Since low vapor resistance is a characteristic of fibrous insulation, the needed vapor resistance must be provided by other means. It is to be noted that, in typical residential conditions, condensation does not occur in fibrous insulation:itself, except when frost has formed on sheathing arid gradually
OUTSIDE TEMPERATURE
Fig. 8. Relative Humidity in Dwellings
winter, after which the drying of spring and summer completes the annual cycle. The average winter temperature arid its duration are factors in the condensation problem. In Fig. 9 the United States is divided into three condensation zones based on winter weather conditions.20 Zone I roughly includes those areas where the design temperature is --20 F Or. colder; zone II those for which the design temperature is zero to -- 20 F, and zone III those at zero and warmer. Within- each zone, similar degrees of con densation trouble are to be expected, and similar corrective measures
apply. In roofs, the condensation problem is much the same as in walls. The
roof covering may be even more resistant to the escape of vapor than wall coverings such as paint;.and while paint is likely to be ruptured,by exces sive moisture, no such relief occurs in roofs. Thus roofs furnish con spicuous examples of rapid decay in lumber.
: In crawl spaces;over uncovered damp ground, a large, water evaporation sometimes occurs and causes condensation on the outer ends of floor joists and other members that are below the floor line and near to the outside. Water vapor from the.crawl space may also enter walls, be transported by rising'air in a stack effect, and even reach the attic by this route when the
(Zones Include Arens with Design Temperatures sbout as follows: Zone I, -20 F and lower-
Zone II. 0 F to - 20 F; and Zone III, above 0 F)
uu lower,
built backward among the fibers. Wet insulation may result from this condition or from liquid condensation seeping down from.a higher level.
Control of Concealed Condensation
An excessive accumulation of moisture in walls (or roofs) can be prer vented by one or more of the following measures: (1) provide, a vapor bar rier to limit vapor entrance into the wall, (2) ventilate the building to reduce vapor pressure therein, (3) ventilate the wall cavity to remove vapor that has entered.
I. Vapor Barrier. A vapor barrier is the principal and most obvious correction, but each measure is more effective if aided by the effect of another. In habitations, some ventilation of the living space, either inci dental or planned, is necessary. . Also, a small amont of cavity ventilation is essential in cases where the vapor inflow is not completely stopped and the moisture storing capacity of the outer wall elements is slight. -This applies to some prefabricated designs using metal siding.
Vapor barrier sheets are often built into the wall near the warm surface. In wood; frame walls they may be applied to the inside surface of the studs. They, are sometimes attached to the warm side of the insulating materials,