Document LoBQ4zkZNKppKdGDX8xpQmZLX

J. W. Ware From: Date: D. W. Hollis June 4, 1985 Subject: VCM RELEASE - MAY 23, 1985 Incident At approximately 1:30 a.m. on May 23, 1985, VCM was released through the old nodule duap Sveco while D300 reactor was being charged and D400 reactor was being dumped. The charge water valve was open on D400 and this allowed VCM to enter the dump aysten. The panel operator, J. D. Sins, started charge of D300 and duap of D400 at about the sane tine. The "A" operator, Darnell Perry, and Danny Fllppo (training), were near D300 Initiator pot to add Initiator at the completion of charge. They noticed VCM coning out of the duap Sweco and Perry radioed to Sins to shut off D400 duap and to close the energency duap valve at the Sweco. The deluge systea was set off by the vapor release. The pressure on D400 spiked up to 10 psig Indicating VCM went Into the reactor. Sins then reported that there had not been a closed light indication on D400 water charge valve all shift. An Inspection of the valve showed that* it was open. The magnet assembly had slipped out of place and when repositioned to give an open Indication, the valve dosed. Due to the pressure spike, D400 reactor was recovered again prior to finish of dump. The charge was aborted on D300 with 327 counts of VCM on the charge meter. The reactor was recovered and recharged The fixed point monitoring system detected VCM levels at the base of D300 and also picked up a one time reading at several points In the new unit. No one was exposed to VCM. Investigation Exaad.netion of reactor Interlocks showed that an open light must be obtained on the reactor valves during charge to complete the circuit. If an open light Is now shown, the Modicon continues to try to open the valve and will not acknowledge any closed signal. * i In the case of the D400 release, the charge water valve never had an open light so It never closed even though the mode on the reactor had been changed several times. All reactor valves that are not controlled by an automatic cycle will close when the mode Is changed. The reactor VCM charge valves are wired so that charge will not start if they do not have an open light. This solves the problem of leaving the VCM valves open due to no open light. rrniHEcrTsicansDnSrTTrs::i J. W. Ware 6/04/85 VCM Release - May 23, 1985 Page 2 wann'Jiag* MhhdUUta tWPn,in|iipiiuiiipifiPi|iii^riiiiiiiuiii!Miiii*iii!mm^mvw * Recoeaendations Changes can be made in the Modlcon interlocks to prevent a recurrence of the D400 release. 1) Modify the following reactor valve interlocks so that they are closed on a mode change even if they never had an open light. a. Colloid charge valve b. Water charge valve c. VCM charge valves d. Main dump valve 2) Interlock the colloid, VCM and recovered automatic charge buttons so that if they are turned off during a charge, it will shut down that system. Currently, they give a charge enable only and cannot be used to stop charge. b Changing the charge sequence so that an open light is not necessary or so valves could be. closed with the push buttons would require extensive wiring changes. After the above changes are made, all the valves can be closed by changing modes. D. W. Hollis rah cc: JF, CWT, CRS, MLN, REP, VEM, GAM(2) Wl I i i i i il ;1 I .1 j I i I i i i -i j f i i i iti !i i i i I I I i II i [ i !l'U 1 J i 3! I I I I i j| !* l i , f * I I i i I i i i 4 I i 1 ;? i i -1 i. *;j j ti,n, j ' j |r : i-' ,I Tf. VAB.0001217449