J CELLULOSE I sayr water he,,.
March 9, 1987
DOW CHEMICAL U.S.A.
LOUISIANA DIVISION P, O. BOX ISO
PLAOUEMINE. LOUISIANA 707SB-01B0
boa ses-sooo
Joan Pennington Analytical Labs
cc: Bruce Alexius Woody Chew Rodney Webb Henry Bell Jack Gathers Ed Pittman Judi Lay Gerald Wagener Mike Nevill
REACTIVE CHEMICALS COMMITTEE REVIEW, FOLLOW-UP
Project: Soft Water Heaters at Cellulose
Project Rep.: Lisa Widere
Committee Present: Wagener, Pittman, Lay, Gathers
Considerations:
1. Check possibilities of contaminating system with organics from the process.
2. Check the design basis for all relief devices.
Response:
1. There is not a possibility of contaminating the hot soft water with organics.
2. The design basis for all relief devices was reviewed by Process Engineering.
Lisa Widere Cellulose Products Plant
sgl
confident Tai. DO 003530
an operating unit op the dow chemical company
DOW CHEMICAL U.S.A.
December 11, 1986
LOUISIANA DIVISION p. O. BOX ISO
PLAOUEMINE. LOUISIANA 707B6-01B0 BOA 389-8000
Lisa Widere Cellulose
4501 Bldg.
cc: Safety Supt: Bruce Alexius - 2805
Plant Mgr: Woody Chew
- 4501
Major Mgr: Rodney Webb - 5701
Safety Mgr: Henry Bell
- 4701T
REACTIVE CHEMICALS COMMITTEE REVIEW - DECEMBER 10, 1986
PROJECT: Soft Water Heaters at Cellulose
PROJECT REPS: Lisa Widere
COMMITTEE PRESENT; Wagener, Pittman, Lay (Nevill), Gathers
CONSIDERATIONS;
1. Check possibilities of contaminating system with organics from the process.
2. Check the design basis for all relief devices.
Please respond in writing to the Committee Chairman within two weeks as to action taken or planned in regard to these considerations.
Jack Gathers
for J. Y. Pennington, Chairman REACTIVE CHEMICALS COMMITTEE
rcb
CONFTDFNTIA! DO 003531
AN OPERATING UNIT OP THE DOW CHEMICAL COMPANY
CATE ^14
Henry Bell Donna Carville Rex Cochran Jack Gathers John Henley Nark Mitchell John Monroe Mike Nevill Gerald Wagener
cci Plant Supt:.
o^
Plant Rep:
gjK a fytJ i
Major Mgr:
Safety Supt: ____
Tech Center Rep:
AS&TL Rep:
(> CP, 4/hotJOas.
tjJJL/usUbREACTIVE CHEMICALS COMMITTEE REVIEW - _
There will be a review meeting
j iHbjlW/.itf
The meeting will be held in
at ^.m. to review _
(What)
If you are unable to attend please arrange for someone to substitute for you, and advise me (283) or Robbie Bagaley (1805) of your
replacement.
J. Y. Pennington, Chairman REACTIVE CHEMICALS COMMITTEE
rcb
CONFIDENTIAL. DO 003532