4Pw Ratings & Data of Discontinued American Boilers & Radiators 25818 FOREWORD - - Boilers prior to 1925, but including the Ideal Arco Round Boiler (1925 - 1929), Ideal Type "A"1 Boiler (1925), and Ideal Yonda Sectional and Smokeless Boilers (1925), were rated on the basis of gross output with allowance for piping loss. The Ideal Assembled Sectional Boiler (1924) was rated in a different manner, with Recommended Load including piping shown in Sq. Ft. E.D.R. This constitutes the dividing Line between "Gross Output"' ratings with allowance for piping loss and current "Net Installed Radiation" ratings which include allowances for normal piping (covered) and Pick up loads and for heating domestic hot water when not more than two bathrooms are to be served, or if the use of domestic hot water does not exceed 75 gallons in 24 hours. In replacing any boiler, the actual heating requirements of the installation should first be determined, since, as has been pointed out, printed ratings have varied from time to time with changes in Boiler Manufacturers' methods of rating their products; whether on new or replacement work, the chief consideration is that "Sufficient Radiation must he installed for the Requirements of the Building". If, because of additional loads placed on the boiler since its installation, it is of insufficient size to take care of the job, it is now even more important that the replace ment be correctly sized in accordance with present-day standards to insure satisfaction. 25819 2 IDEAL SECTIONAL BOILER U898 - 1906) 30"& 40" Bciler No. 502 or 512 602 or 612 702 or 712 084 or 184 085 or 185 086 or 186 087 or 187 088 or 188 045 or 245 046 or 246 047 or 247 048 or 248 049 or 249 050 or 250 051 or 251 602 or 62 603 or 63 604 or 64 605 or 65 606 or 66 703 or 73 704 or 74 705 or 75 706 or 76 Rating STEAM `Load lac. Piping - -225 300 375 188 250 314 375 500 625 750 900 900 1100 1300 1500 1700 1900 2100 314 420 520 630 750 750 920 1090 1250 1420 1590 1750 1000 1200 1400 1600 1800 2000 2300 26 00 2800 835 1000 1170 1340 1500 1670 1920 2170 2340 HOT WATER `Load Inc. Rating Piping 375 313 500 420 625 520 625 825 1025 1250 1250 1500 1825 2150 2475 2775 3100 3450 520 690 855 1045 1045 1250 1520 1790 2060 2320 2590 2880 1650 2000 2350 2700 3050 3500 4000 4500 5000 1380 1670 I960 2260 2550 2920 3340 3760 4180 Grate , Area Sq. ft 1.2 1-5 1.8 2.25 3-00 3-75 4.50 5-25 5.00 6.00 7.1 8.2 10.0 7.1 8.2 6.2 6.2 7-5 8.7 10.1 10.1 12.1 14.1 16.1 Water Lise Inches 43/ 43 43 44 44 44 44 44 50 50 50 50 50 50 50 58 58 58 58 58 58 58 58 58 103 or 14 104 or 15 203 or 24 204 or 25 205 or 26 303 or 35 304 or 36 305 or 3? 403 or 45 404 or 46 405 or 47 504 or 46 505 or 57 5 06 or 58 13 34 44 55 300 350 400 450 500 550 600 650 850 1000 1100 1300 1500 1700 IDEAL PORTABLE ROUND (1898 - 1906) 250 292 334 376 418 460 500 544 710 835 920 1085 1252 1420 400 450 550 625 675 875 975 1100 1400 1600 1700 2000 2250 2400 350 775 1200 1775 334 376 460 52z 565 730 815 920 1170 1340 1420 1670 I860 2000 292 647 1000 1480 IDEAL JUNIOR BOILER (1898 - 1908) 1.97 1.97 2.4 2.4 2.4 3-4 3-4 3-4 4.9 4.9 4.9 7.1 7.1 7.1 1.97 3-4 4.9 7.1 41 46-1/2 42 48-1/4 54-1/2 43-1/2 50-1/4 57 45 52 59 53 61 69 201 301 302 1500 or 1501 1600 or 1601 2 -.20 or led 1900 or 1901 175 250 300 300 340 r-r. . *- J 575 146 1.22 46 209 1.76 46 250 1.76 50 250 500 420 1.22 48-1/4 284 600 500 1.22 52-1/4 i' 0 L75 - ) n 1.76 48-3/8 480 900 750 1.76 52-i/c `The highest ratings listed are taken . An allowance for piping has been made on these loads. 25820 r- Boiler No. 16 18 20 120 113 or 130 114 223 or 230 224 or 240 225 333 or 330 334 or 340 335 443 or 430 444 or 440 44!) or 450 554 or 530 555 or 540 556. or 550 IDEAL INVINCIBLE BOILER (1898 - 1908) Rating STEAM `Load Piping HOT WATER `Load Inc. Rating Pi ping 350 500 650 225 275 325 375 425 475 545 615 800 900 1000 1150 1350 1500 250 360 465 161 197 232 268 304 340 390 440 570 645 715 820 965 1070 550 800 1050 375 425 600 675 850 1000 1250 1500 1650 1825 2150 2400 395 570 750 268 304 4j0 485 610 715 895 1070 1180 1300 1540 1720 Grate Area Sn P* fnrKoi* 1.4 1.76 2.18 1.97 1.97 1.97 2.4 2.4 2.4 3-4 3-4 3.4 4.9 4.9 4.9 7.1 7.1 7.1 38-1/2 39-3/4 41 " 41 46-1/2 42 48-1/4 54-1/2 43-1/2 50-1/4 57 45 5/ 59 53 61 69 A or C--015 or 152 A or C-018 or 182 A or C-019 or 183 A or C-020 or 211 A or C-021 or 212 A or C-022 or 213 A or C-024 or 241 A or C-025 or 242 A or C--026 or 243 A or C-027 or 281 A or C-028 or 282 A or C-029 or 283 A or 0-031 or 321 A or C-032 or 322 A or C-033 or 323 IDEAL PREMIER ROUND BOILER (1900 - 1908) (HARD COAL) 225 300 375 400 450 500 550 610 670 850 925 1000 1100 1200 1300 IBS 250 313 334 376 418 460 510 560 710 770 835 920 1000 1085 375 500 600 660 750 825 900 1000 1100 1400 1525 1650 1825 2000 2150 313 413 500 550 625 690 750 835 920 1170 1275 1330 1525 1670 1795 1.23 1.77 1.77 2.4 2.4 2.4 3-14 3-14 3.14 4.3 4.3 4.3 5-6 5-6 5-6 49-1/2 52-1/2 57 47-1,2 53 58-1/2 49 54 59-1/2 51 57-1/4 63-3/4 53-1/4 60 66-1/4 IDEAL PREMIER ROUND BOILER (SOFT CfJAL) (1900 - 1906) B or B-015 or 152 B or D-018 or 182 B or D-021 or 212 B or D--022 or 213 B or D-O25 or 242 B or D--026 or 243 B or D-028 or 282 B or D-029 or 283 E cr D-C32 or 322 B or D-033 or 323 200 250 400 4^0 500 600 800 900 1050 1200 167 209 334 375 416 500 670 750 87' IOCO 325 400 650 750 825 1000 1325 1500 1725 2000 270 334 542 625 690 835 1105 1250 1440 1670 1.23 1.77 2.4 2.4 3.14 3-14 4.27 4.27 5.6 5.6 49-1/4 52-1/2 53 56-1/4 54 59-1/2 57-1/4 63-3/4 60 06-I/4 `The highest ratings listed are taken. An allowance for piping has been made on these loads. 25821 4 IDEAL SECTIONAL BOILER (1900 - 1904) Boiler No. 065 or 365 066 or 366 067 or 367 068 or 368 069 or 369 0610 or 3610 0611 or 3611 0612 or 3612 0613 or 3613 15-1-W 15-2-W 17-3-W 17-4-W 17-5-W 19-3-Vf 19-4-W 19-5-W 22-3-W 22-4-W 22-5-W 25-3-W 25-4-W 25-5-W 28-3-W 28-4-W 28-5-W 31-3-W 31-4-W 31-5-W 34-3-W 34-4-W 34-5-W Rating STEAM Load Inc. Piping HOT WATER "Load Inc. Rat ing Piping 1800 ~ 2250 2700 3150 3600 3250 3600 3950 4300 1500 1880 2260. 2630 3000 2720 3000 3300 3600 3000 3700 4450 5200 5950 5350 5925 6500 7075 25UU 3100 . 3720 4350 4970 4460 4925 5420 5900 IDEAL STANDARD WATER BOILER (1904 - 1909) 400 425 500 550 600 750 825 900 875 950 1025 1250 1350 1425 1500 1600 1700 1750 1950 2050 2350 2500 26 5 0 334 355 420 460 500 625 690 750 730 795 855 1040 1130 1190 1250 1340 1420 1460 1630 1710 I960 2090 2210 Sq. Ft. 8.0 10.0 12.0 14.0 16.0 14.0 16.0 16.0 16.0 1.06 1.06 1.40 1.40 1.40 1.76 1.76 1.76 2.40 2.40 2.40 3.44 3.44 3.44 4.12 4.12 4.12 4.90 4.90 4.90 5-94 5-94 5-94 Water !i ne Inches 6l 61 61 61 61 61 61 61 61 ACME FIRE BOX BOILER (1904 - 1914) 1 900 835 1400 1300 4.3 51 2 1000 925 1600 1480 5-3 51 3 1200 1110 1900 1760 6.3 51 4 1400 1300 2200 2040 6.7 56 5 1700 1570 2700 2500 8.0 56 6 2100 1940 3400 3150 9.2 56 7 2200 2040 3500 3240 9-5 61 8 2500 2320 4000 3700 11.0 61 9 2900 2680 4600 4250 12.5 61 10 3200 2960 5100 4720 13.0 66 11 3800 3520 6100 5650 14.7 66 12 4400 4070 7000 6500 16.4 66 13 4900 4540 7800 7210 18.6 68 14 5800 5360 9300 8600 20.6 68 IDEAL RETURN FLUE PORTABLE STEEL BOILER (1904) 1200 1500 1800 noo 26 0 0 3000 3500 4500 1200 1500 1800 2100 26 0 0 3000 3500 4500 1110 1390 1670 1940 2400 2780 3240 4160 2000 2475 2975 3475 43OO 4950 5775 7425 1850 2290 2750 3220 3960 4560 5350 6850 7-5 9.0 9.0 12.0 12.2 14.0 15.7 17.5 67 67 67 67 77 77 11 77 "The highest ratings listed are taken. An allowance for piping has been Bade on these loads. 25822 Boiler No. S or W-2-4 S or W-2-5 S or W-2-6 S or W-2-7 S or W-3-5 S or W-3-6 S or W-3-7 S or W-4-5 S or W-4-6 S or W--4--7 S or K-5-5 S or W-5-6 S or W-5-7 S or W-5-8 S or W-5-9 Rating -825 300 375 450 500 600 700 800 1000 1200 1400 1700 2000 2300 2600 IDEAL COKE BOILER (1904 - 1906) STEAM `Load Inc. Piping HOT WATER *Lond Inc. Rating Piping 188 250 313 376 418 500 585 670 835 1000 1170 1420 1670 1920 2170 375 500 625 750 825 1000 1150 1325 1650 2000 2325 2800 3300 3800 4300 313 418 522 625 690 835 960 1105 1380 1670 1940 2340 2760 3170 3600 Grate Area Sq. Ft. 1.05 1.46 1.82 2.18 2.1 2.6 3-1 3-4 4.3 5.1 5.0 6.2 7.5 8.8 10.0 Indies 45-1/2 45-1/2 45-1/2 45-1/2 47 47 47 57-1/2 57-1/2 57-1/2 64 64 64 64 64 T-30-S or W T-33-S or W T-38-S or W T-44-S or W T-50-S or W T-56-S or W T-62-S or W T-68-S or W 1-19--S or 1-22-S or W 1-25-S or 1-2S-S or W 1-31-S or W 1-34-S or W 250 325 385 535 700 900 1125 1375 IDEAL PERFECTION BOILER (1905) 179 400 286 232 525 376 275 635 455 383 680 486 500 1155 825 645 1485 1060 805 1860 1330 985 2270 1620 * * IDEAL ARCO ROUND BOILER (SOFT COAL) (1906 - 1909) 275 400 500 800 1000 1250 229 332 415 665 835 1040 450 650 825 1325 1650 2075 375 540 685 1100 1375 1730 "Equipped with First Pattern Arco Base 1.2 1.6 2.0 2.6 3-4 4-3 5-2 6.3 1.76 2.40 3.14 4.12 4.90 5-94 42 43-1/4 43-1/2 45-3/8 45-3/4 46-3/8 46-5/8 46-7/8 45-1/2 49 49-1/4 50 52-1/2 54-3/4 2-19-S or W 3-19-S or W 2-22-S or W 3-22-S or W 2-25-S or W 3-25-S or W 2-2&-S or W 3-2S-S or W 2-31-S or 3-31-S or W 2-34-S or W 3-34-S or W "IDEAL ARCO ROUND BOILER (SOFT COAL) (1906 - 1909) 350 400 525 575 625 700 900 1000 1275 1400 1500 1650 292 332 437 480 520 582 750 835 1060 1165 1250 1370 575 650 875 950 1025 1150 1500 1650 2100 2325 2475 2725 480 540 730 790 850 955 1250 1370 1750 1940 2060 2280 1.76 1.76 2.40 2.40 3-14 3-14 4.12 4.12 4.90 4.90 5 94 5.94 50 54-1/2 53-1/2 56-7/8 54-1/4 59-1/4 56 6I-3/4 57-1/4 63-1/4 59-3/8 65-1/2 "Equipped wi th First Pattern Arco Base `The highest ratings listed are taken. An allowance for piping has been made on these loads. 25823 Boiler No. > or W-3&-5 S or W--36--6 S or W-36-7 S or W-36-8 S or W-36-9 Rating 2100 2625 3150 3675 4200 IDEAL SECTIONAL BOILER (1904 - 1925) `Load Inc. Piping 1640 2050 2460 2860 3280 Rating 3450 4325 5200 6050 6925 `Load Inc. Piping 2700 3380 4050 4720 5440 Grate Area Sq. Ft. 9.12 11.4 13*7 16.0 18.2 Water Line Inches 60-3/4 60-3/4 60-3/4 60-3/4 60-3/4 S or W-30-5 S or W-30-6 S or W-30-7 S or W-30-8 1275 1625 1975 2325 1000 1270 1540 1820 1904 - 1906 2100 2675 3250 3825 1640 2080 2540 2980 8.9 10.9 12.8 14.7 60-1/2 60-1/2 60-1/2 60-1/2 S or W-28-5 S or W-28-6 S or W-28-7 S or W-28-8 1300 1625 1950 2275 1015 1270 1520 1780 1904 - 1925 2150 26 75 3200 3725 1680 2080 2500 2900 6.24 7.80 9.36 10.92 53-3/8 53-3/8 53-3/8 53-3/8 S or VI-25-5 S or W--25--6 S or W--25--7 S or W-25-8 1100 1350 1600 1850 860 1055 1250 1440 1909 - 1925 1825 2225 2650 3050 1420 1740 2065 2380 5.44 6.80 8.16 9.52 51 51 51 51 S or W-22-5 S or W-22-6 S or W-22-7 S or W--22--S 800 1000 1200 1400 625 780 935 1090 1904 - 1925 1300 1650 2000 2350 1015 1290 1560 1830 4.08 5.10 6.12 8.00 46-1/4 46-1/4 46-1/4 46-1/4 S or W-21-5 S or W-21-6 S or W-21-7 800 1000 1200 S or W--19--5 S or W--19--6 S or Vt-19-7 600 750 900 S or K-15-4 S or W-15-5 S or Vi--15--6 S or V-15-7 S or >i--15--8 300 425 550 675 800 625 780 935 470 585 700 234 332 430 525 625 1904 - 1906 1325 1650 2000 1909 - 1925 1000 1250 1500 1906 - 1920 500 700 90Q 1100 1300 1035 1290 1560 780 975 1170 390 545 700 860 1015 4.1 50 5-1 50 6.1 50 3.32 4.15 4.98 43-3/8 43-3/8 43-3/8 1.95 2.60 3.25 4.9 5-7 40-7/8 40-7/8 40-7/8 40-7/8 40-7/8 `Hie highest ratings listed are taken. An allowance for piping has been ade on these loads. 25824 Boiler No. S or T-48-6 S or T-48-7 S or T-48-8 S or T-48-9 S or T-48-10 T-48-11 T-48-12 W-4S-6 T-48-60 IDEAL SECTIONAL BOILER (1906 - 1922) Rating STEAM Load Inc Piping HOT WATER Load Inc. Rating Piping - 5275 6300 7325 8350 9375 10,400 11,425 4400 5260 6100 6960 7820 8700 9550 8700 7250 Grate Area Sq. Ft. 18.00 21.60 25.20 28.80 32.40 25.20 25.20 18.0 Water Line Inches 72 72 72 72 72 72 72 W-48-7 W-48-70 W-48-8 T-48-80 10.375 12,050 8650 10,070 21.60 25.20 W-48-9 W-4S-90 W-48-10 W-48-100 13.725 15.400 11.500 12,900 28.80 32.40 T-48-110 T-48-120 17,075 18,750 14.250 15,650 25.20 25.20 1200 1500 1800 2200 2600 3000 3600 4500 1200 1500 1800 2200 26 00 3000 3600 4500 IDEAL CYLINDRICAL STEEL BOILER (1906 - 19 1 4) 1110 1390 1660 2040 2400 2760 3325 4155 2000 2500 3000 36 0 0 4300 5000 6000 7500 1850 2310 2780 3325 3980 46 20 5550 6840 8.75 8.75 8.75 12.0 12.0 14.0 16.0 18.0 58 55 58 61-1/2 61-1/2 61-1/2 61-1/2 61-1/2 IDEAL PREMIER BOILER (1908 - 1909) 1015 or 1115 2015 or 2115 175 200 146 167 300 250 325 270 3015 or 3115 225 188 350 292 1018 or 1118 2018 or 2118 275 300 230 250 450 375 500 418 3018 or 3118 325 270 550 460 1021 or 1121 400 334 600 500 2021 or 2121 3021 or 3121 4021 or 4121 425 450 475 355 375 396 650 542 700 585 750 625 1024 or 1124 2024 or 2124 525 575 438 480 875 730 950 792 3024 or 3124 625 522 1025 855 4024 or 4124 650 542 1075 900 1027 or 1127 750 625 1250 1042 2027 or 2127 202? or 31^7 800 S50 670 710 1325 14 00 1105 r.7C 4027 or 4127 900 750 1475 1230 1.21 1.21 1.21 1.76 1.76 1.76 2.4 2.4 2.4 2.4 3-14 3-14 3-14 3-14 3-9 3.9 3-9 40-1/2 44-1/2 48-1/2 43-1/4 47-1/2 51-3/4 44-1/2 49 53-1/2 58-1/8 45-1/2 50-1/4 55 59-9/16 46-3/8 51-5/16 r6-l/4 61-3/16 n e highest ratings listed are taken An allowance for piping has been Bade on these loads. 25825 8 "IDEAL ARCO ROUND BOILER (190$ - 1924J Boiler No. 3-19-S or W 3-20-S or W 3-22-S or W 3-23-S or W 3-25-S or W 3-28-S or W 3-32-S or W 3-34-S or W 4-19-S or W 4-20-S or W 4-22-S or W 4-23-S or W 4-25-S or W 4-28-S or W 4-31-S or W 4-34-S or W 5--19--S or W 5-20-S or W 5-22-S or W 5-23-S or W 5-25-S or W 5-28-S or W 5-31-S or W 5-34-S or W 6--19--S or W 6-20-S or W 6-22-S or W 6-23-S or W 6--25--S or W 6-28-S or W 6-31-S or W 6-34-S or W Rating 385 4j\j " 535 610 700 900 1125 1375 410 480 570 650 750 965 1200 1465 430 500 600 685 800 1025 1275 1550 450 520 630 715 835 1070 1330 1615 STEAM `Load Inc. Piping 300 352 418 475 546 705 880 1070 320 375 445 506 585 752 935 1140 336 390 470 535 625 800 995 1210 352 406 492 558 650 635 1040 1260 HOT WATER `Load Inc. Rating Piping 635 740 880 1000 1155 1485 1860 2270 675 790 940 1065 1240 1590 1980 2415 710 825 990 1130 1320 1690 2100 2555 740 860 1040 1180 1375 1765 2195 2665 495 57 6 685 780 900 1160 1450 1770 527 615 735 830 965 1240 1540 1880 554 612 770 880 1030 1320 1640 1990 577 670 810 920 1070 1380 1710 2080 "Equipped with Second and Third Pattern Arco Bases Grate Area Sq. Ft. 1.76 2.23 2.40 2.91. 3.14 4.12 4.90 5-94 1.76 2.23 2.40 2.91 3.14 4.12 4.90 5.94 1.76 2.23 2.40 2.91 3.14 4.12 4.90 5.94 1.76 2.23 2.40 2.91 3-14 4.12 4.90 5-94 Water Line Inches 40- 7/8 41- y/m 42- 1/4 41- 5/16 42- 3/4 44 45- 5/8 46- 3/8 45- 1/2 46- 1/8 47 46- 5/8 47- 7/8 49- 1/4 51 52 50 50- 3/4 51- 1/2 51- 3/8 52- 1/2 54-1/4 56- 1/4 57- 1/2 54- 5/8 55- 5/16 56- 1/4 56-1/8 57- 5/6 50-1/2 61-5/8 63-1/8 364-S or W 374-S or W 384-S or W 394-S or W 3104-S or W 468-S or W 478-S or W 488-S or W 498-S or W 4108-S or W 4118-S or W 4128-S or W 670-S or W 680-S or W 690-S or W 610Q-S or W 6110-S or W 6120-S or W 974-S or W 984-S or W 994--S or W 9104-S or W 9H4-S or W 9124-S or W 1500 1800 2100 2400 2700 3000 3500 4000 4500 5000 5500 6000 6300 7200 8100 9000 9900 10,800 8750 10,000 11,250 12,P00 13.750 15.000 IDEAL DOWNDRAFT SMOKELESS BOILER 1250 2450 1505 1755 2950 3450 2005 2260 3950 4450 2505 2920 4800 5600 3340 6400 3760 7200 4180 8000 4600 5000 526 0 6000 6760 8800 9600 10,000 11,500 13,000 7500 826 0 9000 14,500 16,000 17,500 7300 14,000 8350 9400 10,420 11,''00 12,520 16,000 18,000 20,000 22,000 24,000 (1913 - 1920) 2050 2460 2880 3300 3720 4000 4680 5350 6000 6700 7350 8000 8350 9600 10,850 12,100 13,370 14,600 11.700 13.370 15,000 16,700 18,400 20,000 54-1/2 54-1/2 54-1/2 54-1/2 54-1/2 61 61 61 61 61 61 61 72 72 72 72 72 72 72 72 72 72 72 72 `The highest ratings listed are taken. An allowance for piping has been made ou these loads. 25826 IDEAL TYPE "A" BOILER (1920 - 1925) 9. Boiler No. Rating STEAM `Load Inc. Piping 1--A--4 or 40 1--A--5 or 50 l-A-6 or 60 l-A-7 or 70 -- 4RQ 600 750 900 450 562 675' HOT WATER `Load Inc. Rating Piping n ks d1000 1250 1500 750 935 1125 Grate Area Sq. Ft. h jn 2.5 3-1 3'7 Water Line Inches oc JJ 35 35 35 2-A-5 or 50 2-A-6 or 60 2-A-7 or 70 2-A-8 or 80 2-A-9 or 90 1100 1400 1700 2000 2300 IDEAL TYPE "A" BOILER (1920 - 1922) 825 1050 1275 1500 1730 1800 2300 28 00 3300 3800 1350 1730 2100 2480 2850 4.0 5-0 6.0 7.0 6.0 43 43 43 43 43 3-A-5 or 50 3-A-6 or 60 3-A-7 or 70 3-A-8 or 80 3-A-9 or 90 3-A-10 or 100 3-A-ll or 110 26 00 3250 3900 4550 5200 5850 6500 1950 2440 2920 3420 3900 4400 4880 1922 4400 5500 6600 7700 8800 9900 11,000 3300 4225 4950 5780 6600 7420 8250 8.0 10.0 12.0 14.0 16.0 18.0 20.0 49 49 49 49 49 49 49 1-04 or 40 1-05 or 50 1-06 or 60 1-07 or 70 1-08 or 80 1-09 or 90 1-010 or 100 675 900 1125 1350 1575 1800 2025 IDEAL TYPE 'C' BOLLER (1920) 526 700 875 1050 1230 1400 1580 1050 1400 1750 2100 2450 2800 3150 820 1090 1365 1640 1910 2180 2460 IDEAL WATER TUBE BOILER (1922) S-or W-23-T-5 S-or W-23-T-6 S-or W-23-T-7 S-or W-23-T-8 S-23-T-9 S-23-T-10 S-23-T-11 W-23-T-90 W-23-T-100 W-23-T-110 S-29-T-5 S-29-T-6 S-29-T-7 S-29-T-8 S-29-T-9 S-29-T-10 S-29-T-11 *-29-1-5 W-29-T-6 W-29-T-7 or 70 W-29-T-8 or 80 K-29-T-9 or 90 W -29-T-lC or 100 W-29-T-H0 600 750 900 1050 1200 1350 1500 1200 1500 1800 2100 2400 2700 3000 442 552 662 772 882 992 1102 882 1102 1320 1540 1770 1980 2200 975 1200 1425 1650 1875 2100 2325 716 882 1050 1210 1380 1540 1710 1Q20 2400 2880 3360 3840 4320 48 00 1410 1765 2120 2470 2820 5180 3525 2.72 3-36 4.00 4.64 5.28 5-92 6.56 5.28 5-92 6.56 4.84 6.05 7.26 8.47 9.68 10.89 12.10 4.84 6.05 7.26 8.47 9.68 10.89 12.1C 44-1/2 44-1/2 44-1/2 44-1/2 44-1/2 44-1/2 44-1/2 52-3/4 52-3/4 52-3/4 52-3/4 52-3/4 52-3/4 52-3/4 `The highest ratings listed are taken. owance for piping has been ade on these loads. 25827 10 Boiler No. S-36-T-5 S-36-T-6 S-36-T-7 S-36-T-8 S-36-T-9 S-36-T-10 S-36-T-11 S-36-T-12 W-36-T-5 W-36-T-6 W-36-T-7 W-36-T-8 or 80 W-36-T-9 or 90 W-36-T-10 or 100 W-36-T-11 or 110 W-36-T-12 or 120 IDEAL WATER TUBE BOILER (1922) Rating STEAM `Load Inc. Piping HOT WATER `Load Inc. Rating Piping 1750 2200 2650 3100 3550 4000 4450 4900 1365 1720 2070 2420 2770 3120 3470 3820 287 5 3600 4325 5050 5775 6500 7225 7950 2240 2800 3380 3940 4500 5070 5650 6200 Grate Area Sq. Ft. 6.0 7.5 9.0 10.5 12.0 13.5 15.0 16.5 6.0 7.5 9.0 10.5 12.0 13.5 15.0 16.5 Water Line Inches 58 58 58 58 58 58 58 58 S or W-79-T-7 S or W-79-T-8 S or W-79-T-9 S or W-79-T-10 S or W-79-T-ll S or W-79-T-12 S or W-79-T-13 S or W-79-T-14 S or W-79-T-15 S or W-79-T-16 S or W-79-T-17 8400 9600 10,800 12,000 13,200 14,400 15,600 16,800 18,000 19,200 20,400 IDEAL WATER TUBE BOILER (1922) 7020 8010 9000 10,000 11,000 12,000 13,000 14,000 15,000 16,000 17,000 13,440 15.360 17,280 19,200 21,120 23,040 24,960 26,880 28,800 30,720 32,640 11,200 12,810 14,400 16,000 17,600 19,300 20,800 22,420 24,020 25,600 27,200 22.96 26.24 29.52 32.80 27.88 31.16 31.16 34.44 34.44 37.72 37.72 67 67 67 67 67 67 67 67 67 67 67 S or W-1724 S or W-1744 S or W-1924 S or W-1944 S or W-2024 S or W-2044 S or W-2224 S or W-2244 S or W-2524 S or W-2544 S or W-2824 S or W-2S44 S or W-3104 S or W-3124 S or W-3144 S or W-3105 S or W-3IO6 IDEAL ARCO ROUND BOILER (1925 - 1929) 400 450 550 600 675 725 825 875 1025 1100 1300 1400 1500 1600 1700 1600 1700 200 225 275 300 330 362 412 437 512 550 650 700 750 800 850 800 850 675 750 925 1000 1125 1200 1375 1450 1700 1825 2150 2350 2475 26 5 0 2825 26 5 0 2825 338 375 463 500 562 600 688 725 850 912 1075 1175 1240 1325 1413 1325 1413 1.4 1.4 1.9 1.9 2.2 2.2 2.6 2.6 3-5 3-5 4.4 4.4 5-3 5-3 5-3 5-3 5-3 48-1/2 50 46-1/2 48 47-1/2 49 48-1/2 50 49-1/2 51 50-1/2 52 51 52-1/2 54 56 62 `The highest ratings listed are taken. An allowance for piping has been nade on these loads. 25828 IDEAL TTPE 'A' BOILER U925) 11 Boiler No. rV* VI* R.--no a t S or W-2205-A' S or W-2206-A S or W-2207-A S or W-2208-A S or W-2209-A S or W-3205-A S or W-3206-A S or W-3207-A S or W-3208-A S or W-3209-A S or W-321&-A S or W-3211-A S or K-3212-A ~ S or W-1814 S or W-1824 S or W-1834 S or W-1844 S or W-1815 S or Vf--1825 S or W--1835 S or W-1845 S or W-1816 S or W-1826 S or W-1836 S or W-1846 S or W-1817 S or W-1827 S or W--1837 S or W-1847 S or W-1818 S or W-1828 S or W-1838 S or W-1848 S or W-1815-S S or W-1825-S S or W-1835-S S or W-1845-S S or W-1816-S S or W-1826-S S or W-1836-S S or W-1846-S S or W-1817-S S or W-1827-S S or W-1837-S S or W-1847-S S or W-1818-S S or W-1828-S S or W-1838-S S or W-1848-S S or W-1819-S S or W-1829-S S or W-1S39-S S or W-1849-S S or W-1810-S S or W-1820-S S or W-1830-S S or W-1840-S STEAM *Load Inc. Rating Piping HOT WATER `Load Inc. Rating Piping 1000 1250 1500 1750 2000 2250 2500 3000 3500 4000 4500 5000 5500 6000 540 600 660 720 780 840 900 960 1020 1080 1140 1200 1260 1320 1380 1440 1500 1560 1620 1680 780 840 900 960 1020 1080 1140 1200 1260 1320 1380 1440 1500 1560 1620 1680 1740 1800 I860 1920 1980 2040 2100 2160 625 780 935 1095 1250 1410 1516 1870 2185 2500 2810 3120 3400 3750 1600 2000 2400 2800 3200 3600 4000 4800 5600 6400 7200 8000 8800 96 00 1000 1250 . 1500 1750 2000 2250 2500 3000 3500 4000 4500 5000 5500 6000 IDEAL T0NDA SECTIONAL BOILER (1925) 306 340 374 407 442 475 510 545 576 611 645 680 715 748 782 815 850 885 916 952 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200 2300 2400 2500 26 00 2700 2800 510 566 623 680 735 791 850 905 965 1020 1075 1132 1190 1248 1300 1360 1415 1470 1530 1590 IDEAL YON DA 340KELESS BOILER (1925) 442 1300 735 475 1400 791 510 1500 850 545 576 611 645 680 715 748 782 815 850 1600 1700 1800 1900 2000 2100 2200 2300 2400 2500 905 965 1020 1075 1132 1190 1248 1300 1360 1415 885 916 952 990 1020 1052 . 1088 1120 1156 1190 1225 26 0 0 2700 2800 2900 3000 3100 3200 3300 3400 3500 3600 1470 1530 1590 1640 1700 1760 1610 1970 1930 I960 2040 Grate Area Sq. Ft. 2.76 3.68 4.60 5-52 6.44 7-36 6.22 7.77 9.32 10.87 12.42 13.97 15.52 17.07 1.94 2.12 2.3 2.47 2.65 2.83 3.01 3.18 3-36 3-54 3.71 3-89 4.07 4.24 4.42 4.60 4.77 4.95 5-13 5.31 2.65 2.83 3.01 3.18 3-36 3.54 3-71 3-89 4.07 4.24 4.42 4.6 4.77 4.95 5.13 5.31 5-49 5.67 5 -85 6.02 6.20 6.37 6-55 6.73 Water Line Inches 50 50 50 50 50 50 56-3/4 56-3/4 56-3/4 56-3/4 56-3/4 56-3/4 56-3/4 56-3/4 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 48 *Tbe highest ratings listed are taken. An allowance for p iping has been nade on these loads. 25829 12 IDEAL ASSEMBLED SECTIONAL BOILER (1924) Boiler No. /Recommended Load-Sq. Ft. E.D.R. Steam Water Grate Area Sq. Ft. Floor Area Occur Inches Water Line Ins. Base Height Inches Chi mney Size Height Inches Feet S or W-1204 S or W-1205 S or W-1206 S or W-1207 S or W-1208 225 375 300 500 375 625 450 750 525 875 .81 1.08 1.35 1.62 1.89 17 x 13-1/2 17 x 17 17 x 20-1/2 17 x 24 17 x 27-1/2 39-1/4 39-1/4 39-1/4 39-1/4 39-1/4 None 11 " 11 tt 8x8 8x8 8x8 8x8 8x8 25 25 30 30 35 /Recomnen dedt Load represents attached load - including piping - which may be placed on boiler in accordance with accepted installation standards for economical operation. Boiler No. S or W--1814 S or W-1824 S or W-1834 S or W-1844 S or W-1815 S or W-1825 S or W-1835 S or W-1845 S or W-1816 S or W-1826 S or W-1836 S or W-1846 S or W-1817 S or W-1827 S or W-1837 S or W-1847 S or W-1818 S or W-1828 S or W-1838 S or W-1848 IDEAL ARCO SECTIONAL BOILER (1923 - 1924) "Installed Radiation Sq. Ft. Steam Water Grate Area Sq. Ft. Floor Area Occupied Inches Water Line Inches Base Height Inches 480 540 600 660 720 780 840 900 960 1020 1080 1140 1200 1260 1320 1380 1440 1500 1560 1620 800 900 1000 1100 1200 1300 1400 1500 1600 1700 1800 1900 2000 2100 2200 2300 2400 2500 26 00 2700 1.77 1.94 2.12 2.30 2.47 2.65 2.83 3.01 3.18 3-36 3-54 3-71 3-89 4.07 4.24 4.42 4.60 4.77 4.95 5.13 27-1/2 x 21-3/4 27-1/2 x 23-1/4 27-1/2 x 24-3/4 27-1/2 x 26-1/4 27-1/2 x 27-3/4 27-1/2 x 29-1/4 27-1/2 x 30-3/4 27-1/2 x 32-1/4 27-1/2 x 33-3/4 27-1/2 x 35-1/4 27-1/2 x 36-3/4 27-1/2 x 38-1/4 27-1/2 x 39-3/4 27-1/2 x 41-1/4 27-1/2 x 42-3/4 27-1/2 x 44-1/4 27-1/2 x 45-3/4 27-1/2 x 47-1/4 27-1/2 x 48-3/4 27-1/2 x 50-1/4 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 43 None II 11 11 tl II II II M II M II 11 M 11 H If It II 11 Chimne y Size i eight Inches Feet 8X8 8X8 8X8 8X8 10 X 10 10 X 10 10 X 10 10 X 10 10 X 10 10 X 10 10 X 10 10 X 10 10 X 10 12 X 12 12 X 12 12 X 12 12 X 12 12 X 12 12 X 12 12 X 12 35 35 35 35 35 35 35 35 35 35 40 40 40 40 45 45 45 45 45 45 IDEAL ARCOFLASH BOILER (1928 - 1932) Boiler No. "Installed Radiation Sq. Ft. Steam Water Grate Area Sq. Ft. Floor Area Occupied Inches Water Line Inches Base Height Inches Chimney Height He ight Inches Feet S or W-18 S or W-20 S or W-22 S or W-24 250 400 300 480 350 560 450 720 1.77 2.18 2.65 3-14 26-1/2 Dia. 28-1/2 " 31-1/4 " 33-1/4 " 38-5/8 38-5/8 38-5/8 38-5/8 11-1/2 11-1/2 11-1/2 11-1/2 8x8 8x8 8x8 8x8 30 30 35 35 "These ratings represent the maximum net loads (240 Bfu per sq. ft. steam and 150 Elu per sq. ft. hot water) that may be connected to the boiler. Allowances have been made in these ratings for normal piping (covered) and pick-up loads and for heating domestic hot water when not more than two bathrooms are to be served, or if the use of domestic hot water does not exceed 75 gallons in 24 hours. 25830 NO. 23 <23 INCH) IDEAL WATER TUBE BOILER Uy23 - 1947) 1J Boiler No. "Installed Radiation Sq. Ft. Steam-Water (site Area Sq.Ft. Firing Firing Rate Rite Us. Lbs.Per Per Hour Hour Floor Ann Ocrunied Inchrc Fire Ifox Dimensions Inches Width Irngtl lleiglit Floor to Center Witter Otse of Crown Qnmney Line Height 3 met Size Heiid Ins. las. Ins. Indies pee S or W-23-T-5 S or W-23-T-6 S or W-23-T-7 S or W-23-T-S S or K-23-T-9 400 640 500 800 600 960 700 1120 800 1280 2.72 3.36 4.00 4.64 5.S "T TYpo - Anthracite Linl lliana Pi red) 31-3/4 x 21 31-3;4 x 25 31-3/4 x 29 31-3-4 x 2] 31-3`4 x 37 2j x 16-L 2 23 x 20-1,''2 23 x 24-V 2 23 X 26-L'2 23 x 32-1/2 44- O'2 44-1/2 44-02 44-L/2 44-L'2 None II II " M 30 8x8 30 30 8 x 12 30 30 8 x 12 35 30 8 x 12 35 30 12 x 12 40 S or W-2305 S or W-23O6 S or K-2307 S or W-23O8 S or W-2309 S or W-SfJlO S or W-C623 S or W-C723 S or W-C823 S or W-0923 S or W-IU23 400 640 500 600 600 960 700 1120 600 LbO 900 1440 2.72 3-36 4.00 4.64 5-258 5-92 Coni (Hand Filed) 31-3'4 x 21 31-3'4 x 25 31-3/4 x 29 31-3/4 x 33 31-3/4 X 37 31-3/4 x 41 23 x 16-1/2 23 x 20-1/2 23 X 24rl/2 23 x 28-1/2 23 x 32-1/2 23 X 36-V2 44-1/2 44-02 44-02 44-1/2 4-1-1/2 44-02 II II II ir 11 H 30 8 x 12 30 30 b x 12 35 30 8 x 12 35 30 8 x 12 35 30 8 x 12 40 30 12 x 12 40 650 770 910 1050 1190 1030 1230 1450 3680 1905 * 16.5 19.3 22.9 25.8 nt 6 Oil Fired 31-3/4 x 25 31-3/4 X 29 31-3/4 x 33 31 -3/4 x 37 31-1/4 X 41 23 x 20-02 23 x 24-1/2 23 x 28-L'2 2") x "12-1/2 2J x "(6-1/2 4002 44-02 44-02 4 01/2 44-1/2 II II II " 30 30 30 30 30 *Minimim Burner Capacity-Lbs. Oil Per flour, based on oil of 39,700 Btu per pound. 8x6 8xb 6 x 12 8 x 12 8 x 12 30 30 30 35 39 SC or WG-23-T-6 SC or WG-23-T-7 SC or WC-23-T-8 SC or WC-23-T-9 SC or WC-23-T-10 SC or W023-T-U 650 770 910 IO3O 1190 1330 1040 lOJO 1155 1680 1905 2130 Stoker Fired 26 31-3 4 x c5 2J X 20-L 2 4 4-- L 2 30 31-3'") x 29 23 x 24-02 4-4-02 35 3!-y4 x 33 23 x 28-1/2 44-02 41 31-3 4 x 37 2J x 32-02 44-02 46 31-3/4 x 41 23 x 35-02 44-02 51 31-3/4 X 46 23 x 40-O'2 44-1/2 " It M " " 30 b \ b 30 30 8x8 30 3D 8 x 12 30 30 8 x 12 35 30 8 x 12 35 30 12 x 12 35 NO. 29 ( 29 INCH) HEAL WATER ME B/lIfJt (1923 - 1937) S or W-29-T-5 S or W-29-T-6 S or W-29-T-7 S or W-29-T-8 800 1000 1200 1400 1280 1600 1920 2240 "T1 Type - Anthracite Coal (Jlnnd Fired) 4.84 6.05 7.26 8.47 3S-1/2 x 30 /fcb-L 2 X 36 38-L' 2 X 42 38-1/2 x 4b 29 x 23-1/2 29 x 29-L 2 29 x 35-L/2 29 x 41-1/2 52-3/4 5^3'4 52-3/4 32-3/4 II It If 33 12 x 12 35 33 12 x 12 35 33 12 x 16 40 33 12 x 16 45 S or W-2905 S or W-2906 S or W-2907 S or W-290B S or W-2W S or W-29IO S or W-2911 800 1000 1200 1400 16 CO 1800 2000 l/SO 1600 1920 "2240 2650 2880 3200 4.84 6.05 7.26 8.47 9.63 10.89 12.10 Coal (Hand Fired) 38-L/2 x 30 36-L 2 x 36 3&-L'2 X 42 38-L'2 x -18 38-1/2 x 54 3S-L'2 X 60 38-1/ 2 x 66 29 x 2> 1/2 29 x 29-1/2 29 x 35-L 2 29 x 41-1'2 29 x 47-L 2 29 x 53-1/2 29 X 59-1/2 52-3/4 52-3/"4 52-3-4 52-3-1 52-3-4 52-3 4 5 2-3'4 II " n 33 12 x 16 35 33 12 x 16 40 33 16 x 16 40 33 16 x 16 45 33 16 x 20 50 33 16 x 20 55 33 20 x 20 60 "These ratings represent the maximum net loads (240 Btu per sq. ft. steam and 150 Btu per sq. ft. hot v>aterj that may be connected to the boiler \! I ow-inr'r s have been made in Mince ratings for normal piping icoveredj and pick-up loads and for healing domestic hot water hcn not more Ibae two bathrooms are to be served, or if the use of domestic tiot water does not exceed 75 gallons in 24 hours. 25831 14 NO. 36 (36 INCH) IDEAL HATER TUBE BOILER (1923 - 1947) Boiler No. S or W-3S-T-6 S or H-36-T-7 S or W-36-T-8 S or K-3&-T-9 S or W-36-T-10 S or W-36-T-11 S or W-35-T-12 S or K--T-13 S or W-3606 S or W-3607 S or W-350B S or W-3609 S or Vf-3610 S or VPtfll S or W-3612 S or Vi-5613 S or W-3614 S or W-3615 "Installed fediation Sn. Pt.. Steaa-tfeter Grate Area Sq.Ft. Floor Area Oocupisd Inches Fire Box Dimensions Indies Width Lmgth Witer Lise Ins. Dase Las. Height Floor to Center of VI VTU UqIC.Ci Inches "T" Type - Anthracite Coal (Hand Fired) 1600 2560 7.50 50-1/4 x 36 36 x 29-1/2 57 12-1/4 38-1/2 2000 3200 9.00 50-1/4 x 42 36 x 35-1/2 57 12-1/4 38-1/2 2400 3840 10.50 50-1/4 x 48 36 x 41-1/2 57 12-1/4 3B-1/2 fflOO 4480 12.00 50-1/4 x 54 36 x 47-1/2 57 12-1/4 38-1/2 3200 5120 13.50 50-1/4 x 60 36 x 53-1/2 57 12-V4 38-1/2 3600 5760 15.00 50-1/4 x 66 36 x 59-1/2 57 12-1/4 33-1/2 4000 6400 16.50 50-1/4 x 72 36 x 65-1/2 57 12-1/4 38-1/2 4400 7010 18.00 50-1/4 x 78 36 x 71-1/2 57 12-1/4 33-1/2 Coal (Hand Fired) 1600 2000 2400 2809 3200 3600 4000 4400 4800 5200 2560 3200 ?J40 4480 5120 5760 6400 7040 7680 8J20 7.50 9.00 10.50 12.00 13.50 15.00 16.50 18.00 19.50 21.00 50-1/4 x 36 50-1/4 x 42 50-1/4 x 48 50-1/4 x 54 50-1/4 x 60 50-1/4 x 66 50-1/4 x 72 50-1/4 X 78 50-1/4 x 84 50-1/4 x 90 36 x 29-1/2 36 X 35-I/2 36 X 41-1/2 36 x 47-1/2 36 x 53-1/2 36 x 59-1/2 36 x 65-1/2 36 x 71-1/2 36 X 77-1/2 36 x 83-1/2 57 57 5? 57 57 57 57 57 57 57 12-1/4 12-1/4 12-1/4 12-1/4 12-1/4 12-1/4 12-1/4 12-1/4 12-1/4 12-1/4 38-1/2 38-1/2 33-1/2 38-1/2 38-1/2 38-1/2 38-1/2 38-1/2 38-1/2 38-1/2 oVJ-L._&Qe. uire11 yleiviit Inches Feet 16 x 20 16 x 20 20 x 20 20 x 20 20 x 20 20 x 20 20 x 24 20 x 24 45 50 50 55 55 60 60 65 16 x 20 16 x 20 20 x 20 20 x 20 20 x 20 20 x 20 20 x 24 20 x 24 20 x 24 24 x 24 45 50 50 55 55 60 60 65 70 75 Boiler No. NO. 36 WATER TUBE BOILER (1923 - 1956) * Installed Radiation Sq. Ft. Steam Water Floor Area Occupied Inches Firing Rate Lbs.. Coal or Gals. Oil Per Hour Water Line Inches Base Height Inches Height Floor to Center of Crown Sieet Inches Chimney Size Height Inches Feet S or W-0736 S or W-O836 S or W-O936 S or W-1036 S or W-H36 S or W-1236 2350 2800 3250 3700 4150 4600 3915 4600 5280 5945 6640 7360 50 x 42 50 X 48 50 X 54 50 X 60 50 X 66 50 X 72 or WO36-T-6 or VC-36-T-7 or WC-36-T-8 or WC-3S-T-9 or WC-36-T-10 or WC-36-T-ll or WCM6-T-12 1900 2350 2800 3250 3700 4150 4600 3210 3915 4600 5280 5945 6640 7360 50 x 36 50 x 42 50 x 48 50 x 54 50 X 60 50 x 66 50 r 72 Oil Fired 7.6 8.9 10.2 11.4 12.6 13.8 57 57 57 . 57 57 57 Stoker Fired 71 57 86 57 101 57 116 57 131 57 145 57 160 57 12-3/8 12-3/8 12-3/8 12-3/8 12-3/8 12-3/8 12-3/8 12-3/8 12-3/8 12-3/8 12-3/8 12-3/8 12-2/8 38-1/2 38-1/2 38-1/2 38-1/2 38-1/2 38-1/2 16 X 16 16 X 16 16 X 20 16 X 20 16 X 20 20 X 20 30 35 40 50 55 6u 38-1/2 38-1/2 38-1/2 38-1/2 38-1/2 38-1/2 38-1/2 12 X 16 16 X 16 16 X 16 16 X 20 16 X 20 16 X 20 20 X 20 25 30 35 40 50 55 60 `For Smoke Hood add 11-1/2". "These ratings represent the maximim net loads (240 Btu per sq. ft. steam and lqO T'.tn per sq. ft. hot water) that may be connected to the boiler. Ailowances have been made in these ratings for normal piping (covered) and pick-up loads and for heating domestic hot water when not more than two bathrooms are to bn served, or if the use of domestic hot water does not exceed 75 gulLons in 24 hours. 25832 NO. 48 (48 INCH) HEAL WATH* TUEE BOILER (1923 - 1945) 15 Boiler No. "Installed C>U>4|1luwvtsvn S^lFt. Steam Water OMwdwiuAca Area Sq.Ft. Firing t0v.i4ueLbs.Per Hour Firing Rate Lbs.Per Hour Ruui Aiea Occupied Indies Height Floor to Fire Box Center Dimensions ' Base of Cmwu1 Inches Line Heirfit Sieet Width Length Ins. Ins. Inches GlifflQCT Sire Heirfit Inches Feet Coal (Hand Fired) S or WM807 S or W-4809 S or W-4809 S or K-4810 S or W-4811 S or W-4812 S or W-4813 S or Vf-4814 6000 9600 7000 moo 7600 12160 6400 13440 9000 14400 9600 15360 10400 16640 11000 17600 21.60 25.20 25.20 28.80 28.80 28.80 32.40 32.40 58-y8 x 68-1/2 48 x 64 69 14-1/2 37-3/4 24 x 24 58-3/8 x 79-1/4 48 x 74-3/4 69 14-1/2 37-3/4 24 x 94 58-3/8 x 90 48 x 85-1/2 69 14-1/2 37-3/4 24 x 28 58-3/8 x 100-3/4 48 x 96-1/4 69 14-1/2 37-y4 24 x 28 56-3/8 x 111-1/2 48 x 107 69 14-1/2 3?-3;4 28 x 28 56-3/8 x 122-1/4 48 x 117-3/4 69 14-1/2 37-3/4 28 x 28 56-3/8 x 133 48 x 128-1/2 69 14-1/2 37-3/4 28 x 32 56-3/8 x 143-3/4 48 x 139-1/4 69 14-1/2 37-3/4 28 x 32 70 75 80 85 95 100 105 no S or IM8Q3-0 S or W-4809-0 S or W-4810-0 S or W-4811-0 S or VM812-0 S or W-4813-0 S or W-4814-0 4965 7945 5645 9035 6330 IOI30 7020 11230 7700 1232O 8380 13410 9060 14530 *** 119.1 135.0 152.0 169.0 185.0 201.5 218.4 Oil Fired 56-3/8 x 79-1/4 48 x 74-3/4 69 14-1/2 37-3/4 20 x 24 50-3/B x 90 48 x 85-1/2 69 14-1/2 37-3/4 20 x 24 58-3/8 X 100-3/4 48 x 96-1/4 69 14-1/2 37-3/4 24 x 24 56-3/8 x 111-1/2 48 x 107 69 14-1/2 37-y4 24 x 24 56-3/8 x 122-1/4 48 x 117-3/4 69 14-1/2 37-3/4 24 x 21 5&-3/8 x 133 48 x 126-1/2 69 14-1/2 37-3/4 24x18 58-3/8 x 143-3/4 48 x 139-V4 69 14-1/2 37-3/4 24 x 28 60 65 70 75 80 85 90 Stoker Fired 3C or WC-4807 4000 6400 37 or VC-4808 4965 7945 SC or W>4809 5645 0035 ( SC or VC-4810 6330 10130 37 or VC-4811 7020 1230 37 or VC-4812 7700 12320 37 or VC4813 8380 13410 37 or VC-4814 9090 14530 15b 5B-y8 x 68-1/2 48 x 64 69 14-1/2 37-3/4 20 x 24 196 58-3/8 x 79 -1/4 48 x 74-3/4 69 14-1/2 37-3/4 20 x 74 223 56-3/8 x 90 48 x 85-1/2 69 14-1/2 37-3/4 20 x 24 250 58-3/6 x 100-3/4 48 x 96-1/4 69 14-1/2 37-3/4 24 x 24 278 56-3/6 x 111-1/2 48 x 107 69 14-1/2 37-3/4 24 x 24 306 58-3/8 x 122-1/4 48 x 117-3'4 69 14-ly2 37-3/4 24 x 24 2)1 5^3/8 x 133 48 x 128-1/2 69 14-1/2 37-3/4 24 x 28 359 58-3/8 x 143-3/4 48 x 139-1/4 69 14-1/2 37-3/4 24 x 2s 60 60 65 70 75 sU 85 90 Boiler No. NO. 79 (79 INCH) IDEAL WATER TUBE BOILER (1923 - 1942) "Installed Firing Firing fadiatiap Grate Rate Rate Sq.Ft.' Area Lbs.Per Lbs.Per Steam Vfeter Sq.Ft. Hour Hour Floor Area Occupied Indies Fire Box Dimensicxis Indies Width Length Height Floor to Center Water Base of Crow (himiev Line Height Sieet Size Heid' Lns. Lns. Indies Indies Fret Sor Vf-7909 S or Vf-7910 S or Vf-7911 S or W-7912 S or W-7913 S or W-7914 S or Vf-7915 S or W-7916 S or W-7917 7000 moo 8500 13600 9500 15200 11000 17600 12000 19200 13000 20800 14000 22400 15000 25600 16000 25600 21.9 24.9 28.0 31.1 34.2 37-3 34.2 34.2 37.3 Coal (Hand Fired) 96-1/2 x 60 76-3/4 x 53-1/2 98-1/2 x 66 78-3/4 x 59-1/2 98-m x 72 78-3/4 X 65-1/2 yy-1/2 x 7b 78-3/4 x 71-1/2 96-1/2 X 64 76-3/4 x 77-1/2 9^1/2 x 90 76-3/4 x 83-62 98-V2 x 96 78-3/4 x 89-1/2 98-1/2 x 102 78-3/4 x 95-1/2 98-1/2 x 108 76-3/4 x 101-1/2 67 67 67 67 67 67 67 67 67 None " II II II 11 II 41 24 x IS 41 24 x & 41 74 x 7H 41 x 7b 41 30 x JO 41 30 x 36 41 30 X 36 41 36 x 36 41 36 x 36 85 90 95 100 105 no 115 120 125 "These ratings represent the imxhiuji net lends (240 Blu per sq. ft. steam and 150 per sq. ft. hot water) tint may be connected to the boiler. Allowances hare been made in tliese rating for noiml piping (covered) and pick-up loads and for heating domestic hot water when not more tlnn two bathrooms are to be served or if the use of domestic hot water does not exceed 75 gallons in 24 hours. * Minimus Goal Burning Capacity - Lbs. Per Hour, based on ooal of 12,500 Blu per pound. `"Minims Burner Capacity - Lbs, Oil Per Hour, based on oil of 19,700 Btu per pound. 25833 16 NO. 79 (79 INCH) IDEAL WATER TUBE BOILER (1923 - 1942) - CONTINUED Boiler No. "Installed Firing Firing Radiation Grate fete fete Sq.Ft^. -Area Los.Per Lbs.fer Steam Water Sq.Ft. Hour Hour Floor Area Occupied Indies Fire Box Dimensions Inches Width Length Line Ins. lleid't Floor to Center Base of Crown Height COlienit Chimney c; _ _ U~. -J, *'-1 1 ^ Ins. Inches Indies Feet S or 1^7909-0 S or W-7910-0 S or W-7911-0 S or W-7912-0 S or W-7913-0 S or W-7914-0 S or W-7916-0 S or W-7916-0 S or W-7917-0 7295 U675 8115 12965 8935 14295 9765 15625 105B5 16935 11415 1K265 12235 19575 13065 20905 13&S5 22215 175.0 195-0 214.0 234.0 254.0 274.0 294.0 313.0 334.0 Oil or Stoker Fired S8 98-1/2 x 60 78-3/4 x 53-1/2 67 3d yy-1/2 x 66 78-3/4 x 59-1/2 67 352 96-1/2 x 72 78-y4 x 65-1/2 67 366 96-1/2 x 78 78-3/4 x 71-1/2 67 41b 96-1/2 x 84 78-3/4 x 77-1/2 67 482 9b-1/2 x 90 78-3/4 x 83-1/2 67 507 98-1/2 x 96 78-3/4 x 89-1/2 67 516 96-1/2 x 102 78-3/4 x 95-1/2 67 543 96-1/2 x 108 78-3/4 x 101-1/2 67 Nooe 11 II II II II II It II 41 24 x 21 bO 41 24 x 24 85 41 24 x 28 90 41 24 x 28 95 41 24 x 28 100 41 24 X 28 105 41 28 x & no 41 28 x 26 115 41 28 x 28 120 ***For Stoker Fired use Prefix "SC" or "VC" and omit Suffix ,"0". NO. 1 IDEAL REDFLASH BOILER (1926 - 1946) Boiler No. "Installed Radiation Sq Ft." Stearn Water * ** Firing Firing Grate fete fete Area Lbs.Per Llis.Pcr Sq.Ft. Hour Hour Floor Area Occupied Indies Fire Box Dimensions Water Base Indies Line lleid't Width Length Ins. Ins. Hei^it Floor to Center of Crown Giimey Siert Size lleidil Inches inches Feet 1-S or W-4 1--S or W-5 1-S or W-6 1-S or W-7 1-S or WU5 1-S or W-9 1-S or W-10 1-S or W-ll 200 32O 290 465 370 590 450 720 530 850 610 975 690 1105 700 1130 1.33 1.79 2.25 2.71 3.17 3-63 4.09 4.55 1-33 or WC-5 1--33 or WC-6 1--SC or WC-7 1-SC or VC-8 1-SC or VC-9 1-SC or WC-10 1-33 or VC-11 280 450 340 515 400 640 460 735 520 830 580 930 640 1025 1-S or W-5-0 1-S or K-6-0 265 425 305 490 1-S or W-7-0 360 575 1-S or V^&-0 400 640 1-S or W-9-0 455 730 1-S or Vi-10-0 495 700 1-S or Vi-11-0 550 880 6.2 7.1 8.4 9.4 10.7 11.7 13.0 Coal (Hand Fired) 26-3/4 x 16-5/16 IS x 11-1.2 45 10 26-3/4 x 20-5/16 lb x 15-1/2 45 10 26-3/4 x 24-5/26 lb x 19-1''2 45 10 26-3/4 x 28-5/16 18 x 23-1/2 45 10 26-3/4 x 32-5/I6 18 x 27-1/2 45 10 26-3/4 x 36-5/16 18 x 31-1/2 45 10 26-3/4 x 40-5/16 lb x 35-1/2 45 10 26-3/4 X 44-5/16 18 x 39-1/2 45 10 Stoker Fired U 26-3/4 x 20-5/16 IS x 15-1/2 45 10 13 26-3/4 x 24-5/16 IS x 19-1/2 45 10 15 26-3/4 x 28-5/16 18 x 23-1/2 45 10 17 26-3/4 x 32-5/16 18 x 27-1/2 45 10 19 26-3/4 x 35-5/16 18 x 31-1/2 45 10 21 26-3/4 x 40-5/16 18 x 35-1/2 45 10 23 25-3/4 x 44-5/16 18 x 39-1/2 45 10 Oil Fired 25-3'4 x 20-5/16 IS x 15-1/2 45 10 26--3 4 x 214--5/lb IS x 19-12 45 10 26-y4 x 28-5/16 18 x 23-1/2 45 10 26-3/4 x 32-5/16 18 x 27-1/2 45 10 26-3/4 X 36-5/16 IS x 31-1/2 45 10 26-3/4 x 40-5/16 18 x 35-12 45 10 26-3'4 x 44-5-16 lo x 33-12 45 10 32 8x8 25 32 8x8 30 32 8 x 8 30 32 8 x 12 35 32 8 x 12 35 32 8 x 12 35 32 12 x 12 35 32 12 x 12 35 32 8x8 30 32 8 x 8 30 32 8 x 8 30 32 8x8 30 32 8 x 12 30 32 8 x 12 35 32 8 x 12 35 32 8x8 30 32 8 x 8 30 32 8x8 30 32 8x8 30 32 8 x 12 30 32 8 x 12 35 8 x 12 35 ^iinimuji Burner Capacity - Lbs. Oil Per Hour - based on oil o| lp.Tt'J B'ai per fxmnd. f^tiaimm Coal Burning Capacity - Lhs. Coal Per Hour - based on oonl of 12,500 Btu per pound. "These ratings represent the maximim net loads (IK) Btu per sq. It steam and 150 Btu persq. ft. hot water) that may be oocnocted to the boiler. Aiicvnnces have been muie in tliese rulings for normal piping (covered) and pick-up loads and for heating domestic hot water wtien not more Unn bathrooms are to be served, or if the use of domestic hot water does not exceed 75 gaiicr.s ^ 74 loirs. 25834 Boiler No. NO. 3 REOFLASH BOILF3? (1927 - 1956) (10 through 14 sections only) 17 ** Installed Radiation _ 5g- Ft. Steam Water Floor Area Occupied Inches Firing Rate Lbs. Coal or Gais. Oii For Hour Water Line Inches Base iieignt Inches Height Floor to Center of Crown Sieet Inches Chimney Si 7p. iieignt Inches Feet Oil Fired 3-S or W-10-0 3-S or W-11-0 3-S or W-12-0 3-S or W-13-0 3-S or W-14-0 2700 3000 3300 3600 3900 4450 4905 5355 5800 6240 45-5/8 X 60 45-5/B X 66 45-5/8 X 72 45-5/8 X 78 45-5/8 X 84 8.8 9.6 10.2 11.o' 11.8 53-1/2 53-1/2 53-1/2 53-1/2 53-1/2 Stoker Fired 12 12 12 12 12 35 16 X 16 35 35 16 X 20 -10 35 16 X 20 10 35 16 X 20 IT 35 20 X 20 45 3-SC or WC-10 3-SC or VE-11 3-SC or WC-12 3-SC or WC-13 3-SC or WC-14 2700 3000 2300 3600 3900 4450 4905 5355 5800 6240 45-5/8 x 60 45-5/8 x 66 45-5/8 x 72 45-5/8 x 78 45-5/8 x 84 98 53-1/2 10a 53-1/2 118 53-1/2 128 53-1/2 137 53-1/2 Hand Fired 12 12 12 12 12 35 16 X 16 35 35 16 X 20 40 35 16 X 20 40 35 16 X 20 45 35 20 X 20 45 3-S or W-10 3-S or W-ll 3-S or W-12 3-S or W-13 2700 3000 3300 3600 4320 4800 5280 5760 45-5/8 x 60 45-5/8 x 66 45-5/8 x 72 45-5/8 x 78 53-1/2 53-1/2 53-1/2 53-1/2 12 12 12 12 35 16 x 20 55 35 16 x 20 60 35 20 x 20 65 35 20 x 20 65 *0n Hand Fired add 21" to length for Snoke Hood. On Oi l and Stoker Fired add 3-1/4" Cor Jxnoko Cnl Kr. NO. 4 REDFLASI BOILER (1928 - 1956) Boiler No. ** Installed Radiation Sq. Ft. Steam Water Floor Area Occupied Inches Firing Rate Lbs. Coal or Gals. Oil Per Hour Water Line Inches Base Height Inches Height Floor to Center of Crown Sheet Inches Qi imnev Si 7,e Heigh Inches Feet 4-S or W-10-0 4-S or W-11-0 4-S or W-12-0 4-S or W-13-0 4-S or W-14-0 2750 3100 3450 3800 4150 4525 5055 5575 6090 6640 * 54-3/4 x 70 54-3/4 x 77 54-3/4 x 84 54-3/4 x 91 54-3/4 x 98 Oil Fired 9-1 10.1 11.0 11.9 12.9 55-1/2 55-1/2 55-1/2 55-1/2 55-1/2 12 12 12 12 12 34 16 x 16 30 34 16 x 16 35 31 16 x 20 IU 34 16 x 2(1 10 34 16 x 20 13 4-SC or WC-10 4-SC or WC-11 4-SC or WC-12 4-SC or WC-13 4-SC or WC-14 3200 3600 4000 4400 4800 5205 5800 6400 7040 7680 54-3/4 X 70 54-3/4 x 77 54-3/4 x 84 54-3/4 x 91 54-3/4 x ys Stoker Fired 115 55-1/2 12S 55-1/2 141 55-1/2 153 55-1/2 166 55-1/2 12 12 12 12 12 34 16 x 16 30 34 16 X 20 35 31 16 x 20 40 34 16 x 20 45 34 20 x 20 50 *0n Hand Fired add 24" to length for Seoke Hood. On Oil and Stoker Fired add 3-1/4" (or Snoke Co11 ar. **These ratings represent the max imum net 1 nads (240 Dtu per sq . (t. steam and 150 Btn per sq . (t. lint water) that may be connected to the Ini ler. Al lowinces have hern made in these rat.ints for normal n i ni n,r (covered) and pick-up loads and for heating domestic hot water when not more than two hath rooms are to he served, or if the use of domestic hot water does not exceed 75 gallons in 24 hours. 25835 IS Boiler No. ** Installed Radiation Sq,. Ft. Steam Water NO. 4 REDFLASH BOILER (1928 - 1956) (Coat'd.) Floor Area Occunied Inches Firing Rate Lbs. Coal or GaJs. Oi 1 Per Hour Water Line Inchps Base Height Tnrhpc Height Floor to Center of Crown Sheet Tnohoo Size T aohn Height Fee* U9 VOOC 9 1 CD 4-S or W-7 4-S or W-8 4-S or W-9 4-S or W-10 4-S or W-U 4-S or W-12 4-S or W-13 3000 3575 4150 4725 5300 5875 6450 4800 5720 6640 7560 8480 9400 10320 < 54-3/4 x 49 54-3/4 x 56 54-3/4 X 63 54-3/4 X 70 54-3/4 x 77 54-3/4 x 84 54-3/4 x 91 Hand Fired 55-1/2 55-1/2 55-1/2 55-1/2 55-1/2 55-1/2 55-1/2 12 12 12 12 12 12 12 34 16 x 20 45 34 20 x 20 50 34 20 x 20 55 34 20 x 20 no 34 2U x 24 65 34 20 x 24 70 3i 20 x 24 75 *On Hand Fired add 24" to length for &noke Hood. On Oil and Stoker Fired add 3-1/4" for Smoke Collar. NO. 5 REDFLASH BOILER (1928 - 1956) Boiler No. ** Installed Radiation Sq. Ft. Steam Water Floor Area Occupied Inches Firing Rate Lbs. Coal or Gals. Oil Per Hour Water Line Inches Base Height Inches Height Floor to Center of Crown Sheet Inches Chimney Size llei MU Inches Feet 5-S or W-10-0 5-S or W-11-0 5-S or W-12-0 5-S or W-13-0 5-S or W-14-0 5-S or W-15-0 5-S or W-16-0 5-S or W-17-0 4400 4900 5400 5900 6400 6900 7400 6240 7040 7840 8640 9440 10240 11040 11840 * 64-1/8 x 80 64-1/8 x 88 64-1/8 x 96 64-1/8 x 104 64-1/8 x 112 64-1/8 x 120 64-1/8 x 128 64-1/8 x 136 Oil Fired 12.4 13-7 15.0 16.3 17.6 19.0 20.4 21.8 59-1/2 59-1/2 59-1/2 59-1/2 59-1/2 59-1/2 59-1/2 59-1/2 12 12 12 12 12 12 12 12 33-1/2 33-1/2 33-1/2 33-1/2 33-1/2 33-1/2 33-1/2 33-1/2 16 x 20 20 x 2(1 20 x 2U 2U x 20 20 x 25 20 x 24 20 x 25 20 x 24 80 35 35 10 45 50 55 60 5-SC or WC-10 5-SC or MC-11 5-SC or WC-12 5-SC or WC-13 5-SC or WC-14 5-SC or WC-15 5-SC or WC-16 5-SC or WC-17 4500 5100 5700 6300 6900 7500 8100 8700 7200 8160 9120 10060 11040 12000 12960 13920 * 64-1/8 x 80 64-1/8 x 88 64-1/8 x 96 64-1/8 x 104 64-1/8 x 112 64-1/8 x 120 64-1/8 x 128 64-1/8 x 136 Stoker Fired 156 59-1/2 175 59-1/2 194 59-1/2 214 59-1/2 234 59-1/2 255 59-1/2 275 59-1/2 296 59-1/2 12 12 12 12 12 12 12 12 33-1/2 33-1/2 33-1/2 33-1/2 33-1/2 33-1/2 33-1/2 33-1/2 20 x 20 20 x 20 20 x 20 20 x 25 20 x 24 20 x 24 20 x 25 24 x 24 35 35 40 45 50 55 6u 65 5-S or tt-8 5-S or W-9 5-S or W-10 5-S or W-ll 5-S or W-12 5-S or W-13 5-S or W-14 5-S or W-15 5000 5700 6400 7100 7800 8500 9200 9900 8000 9120 10240 11360 12480 13600 14720 15840 * 64-1/8 x 64 64-1/8 x 72 64-1/8 x 80 64-1/8 x 88 64-1/8 x 96 64-1/8 x 104 64-1/8 x 112 64-1/8 x 120 Rand Fired 59-1/2 69-1/2 59-1/2 59-1/2 59-1/2 59-1/2 59-1/2 59-1/2 12 12 12 12 12 12 12 12 33-1/2 33-1/2 33-1/2 33-1/2 33-1/2 33-1/2 33-1/2 33-1/2 20 x 24 20 x 24 24 x 24 24 x 24 24 x 28 21 x 28 24 x 28 28 x 28 60 65 70 75 80 85 90 yu *0n Hand Fired add 28" to loigth for Smoke Rood. On Oil and Stot;er Fired add 3-1/1" for Smoke Col 1 ar. "These ratings represent the maximum net loads (241) Htu per sq. ft. steam and 150 Htu per sq. ft. hot water) that may be connected totheboiler. Al lowances have lieen made in these ratings for normal pining (covered) and pick-up loads and for heating domestic hot water when not more than two bathrooms are to bn served, or if the use of domestic hot water does not exceed 75 gal Ions in 21 hours. 25836 NO. 12 IDEAL OIL B0IIR (JACKETED) (1931 - 1942) Boiler No. "Installed Firing Rviifttirwi Grate fete StefL^fe-ter -Area Lbs.Per Sq.Ft. Hour Firing fete Lbs.Per Hour ,T" 'r Area Occupied indies Fire Box Dimaisions Indies Width Length Water Line Lns. Hei^it Floor to Center Lkse of Cnwn 1Height fcheet Ins. Indies Qiiimey Size Height Inches Feet S or W-0412 S or W-0512 S or W-0612 S or W-0712 510 815 660 IO55 810 1295 960 1535 10.8 13.8 16.9 20.0 u 32-5/8 x 34 32-5/8 X 42 32-5/8 x 50 32-5/8 x 58 23 x 22-1/4 50-3/8 23 x 30-1/4 50-3/8 23 x 38-1/4 50-3/8 23 x 46-1/4 50-3/8 32-3/4 32-3/4 12-1/2 32-3/4 12-1/2 32-3/4 12-1/2 32-3/4 8x8 8x8 8 x 12 8 x 12 30 30 30 35 sfksed on oil of 19.700 Btu per lb. //Dunmsians apply to flndi jacket. For extended jacket add 24" to last figure. NO. 21 IDEAL STOKER BOILER (1932 - 1942) SC or WC-421 SC or VC-521 SC or NC-621 SC or NC-721 510 710 910 mo 815 11$ 1456 1776 M 20 27 34 42 `"Based on Coal of 12,500 Btu per lb. 34 x 34 34 X 42 34 x 50 34 x 58 23 x 22-1/4 55-3/8 13 x 30-1/4 55-3/8 23 x 38-1/4 55-3/8 23 x 46-1/4 55-3/8 7-1/8 7-1/8 7-1/8 7-V8 37-3/4 37-3/4 37-y4 37-3/4 8x 8 8x 8 8 x 12 8 x 12 30 30 35 40 IDEAL ARCO ROUND BOILER (1929 - 1942) S or W-1704 S or W-1904 S or W-2004 S or W-2204 S or W-2504 Sor W-2804 No. 4 Series: Base, Firepot, Single Section and Dome 200 320 1.4 24-3/4 Dia. 15 Dia. 47-3/8 13 275 440 1.88 26-1/2 17-1/2 44-64 12 330 530 2.23 23-1/2 19 46-3/4 12 380 610 2.62 32-1/8 21 45-L'8 12 500 800 3-53 600 960 4.36 34-7/8 38-7/8 23-1/2 27 47-1/8 48-1/2 12 12 39-1/4 36-1/2 35-1/2 38-1/2 39 39-V2 8x8 8x8 8x8 8 x 12 8 x 12 8 x 12 30 30 30 35 35 35 S or W-1705 S or W-1905 S or W-2005 S or W-2205 S or W-2505 S or W-2B05 220 350 300 480 350 575 440 705 580 930 750 1200 No. 5 Series: 1.4 1.88 2.23 2.62 3-53 4.35 Base, Pircpot, Douhle Section and Dome 24-3/4 Dia. 15 26-1/2 17-1/2 51-7/6 49-1/4 28-1/2 32-1/8 34-7/8 38-7/8 19 21 261/2 T( 50-58 51 52-1/8 53-1/8 13 12 12 12 12 12 39-1/4 36-1/2 36-1/2 38-1/2 39 39-1/2 8x8 8x8 8x8 8 x 12 8 x 12 12 x 12 30 35 35 35 40 45 S or W-1706 S or W-1906 Sor W-2006 S or W-22G6 SorW-2506 S or W-806 No. 6 Series: Base, Firepot, Double Section, Single Section and Dome 240 385 325 520 380 610 460 735 625 1000 800 1280 1.4 1.88 2.23 2.62 3-53 4-35 24-3/4 Dia. 26-1/2 iB-1/2 32-1/8 34-7/8 38-7/8 15 17-1/2 19 21 23-1/2 27 56-3/8 13 39-1/4 5663 12 35-1/2 54-3/4 12 35-1/2 58-V8 12 38-1/2 57-1/8 12 39 58 12 39-V2 8x8 8x8 8 x 12 8 x 12 8 x 12 12 x 12 35 35 35 40 40 45 "These ratings represent the maximum net loads (240 Btu per sq. ft. steam and 150 Btu per sq. ft. hot water) that may be connected to the boiler. AJJonnces have been unde in these ratings for normal piping (covered) and pick-up loads and for heating domestic hot water wh(n not more tlnn two Intluooms are to be served, or if the use of domestic hot water does not exceed 75 ^lloos in 24 hours. 25837 20 IDEAL ARGOLA WATER BOILER (1932 - 1947) Coal Fired Boiler No. 4-A, AJ or AI 5-A, AJ or AI 6-A, AJ or AI 7-A, AJ or AI Sj-A, AJ or AI 9-A, AJ or AI 10-A, AJ or AI Installed - Whter 120 170 220 270 320 370 420 5-A-O, AJ-0 or AI-0 6-A-O, AJ-0 or AI-0 7-A-O, AJ-0 or AI-0 8-A-O, AJ-0 or AI-0 9-A-O, AJ-0 or AI-0 10-A-0, AJ-0 or AI-0 150 200 250 300 350 400 Grate Ares. Sq.Ft. 0.67 0.90 1.13 1-36 1.59 1.82 2.05 Floor Area 0ccunied Inches Fire Box lAnensioo Inches Width Length 17 x 12 17 x 15 17 X 18 17 x 21 17 x 24 17 x 27 17 x 30 12-5/8 12-5/8 12-5/8 12-5/8 12-5/8 12-5/8 12-5/8 8-3/4 11-3/4 14-3/4 17-3/4 20-3/4 23-3/4 26-3/4 Oil Fired 17 x 15 12-5/8 17 x 18 17 x 21 12-5/8 12-5/8 17 x U 17 x 27 17 x 30 12-5/8 12-5/8 12-5/8 11-3/4 14-3/4 17-3/4 20-3/4 23-3/4 26-3/4 Base Height Ins. 5 5 5 5 5 5 5 Hei^it Floor to Center Of Crnvn Sieet Inches 36-3/8 36-3/8 36-3/8 36-3/8 36-3/8 -3/8 36-3/8 5 36-3/8 5 36-3/8 5 36-3/8 5 36-3/8 5 35-3/8 5 35-3/Sc ARCOLA WATER HEATER FOR HOT WATER SUPPLY (1942 - 1947) Heater Number 1004-A 1005-A 1006-A 1007-A 1008-A 1009-A 1010-A Number of Sections 4 5 6 7 8 9 10 Nominal Capacity Gallons Coal 240 320 Oil ... 200 400 260 480 320 560 380 620 440 680 500 Length Inches 12 15 18 21 24 27 30 TAPPINGS Inlets Inches Outlets Inches 1-2 1/2 1-2 1/2 1-2 1/2 1-2 1/2 1-2 1/2 1-2 1/2 1-2 1/2 2-2 2-2 2-2 2-2 2-2 2-2 2-2 Qunney Size Height Inches Feet 8x8 8x8 8x8 8x8 8x8 8x8 8x8 30 30 30 30 30 30 30 8x8 8x8 8x8 8x8 8x8 8x8 30 30 30 30 30 30 Size of Smoke pipe Inches 6 6 6 6 6 6 6 NEW IDEAL ARCO ROUND BOILER (JACKETED) (1934 to 1939) Boiler No. S or W-181 S or W-201 S or W-221 S or W-222 S or W-223 S or W-252 S or W-253 S or W-282 S or K-283 Installed Radiation Grate Sq.Ft. Area Steam Vfeter Sq.Ft. // 300 480 1.77 350 560 2.18 400 640 2.65 450 720 2.62 500 800 2.62 600 960 3-53 650 1040 3-53 750 1200 4.35 800 1280 4.36 Firing Firing fete fete Lbs.Per Lbs.fer Hour Hour Floor Area Occupied Inches 26-1/2 Dia. 28-1/2 31-1/4 32-1/4 32-1/4 35 35 39 39 Fire Box Dimensions Water Inches Line Width Length Ins. 18 Dia. 20 22 22 22 25 25 28 18 36-5/8 38-5/8 3H/8 47 51-3/4 48-1/2 53-1/2 50-3/8 55-V2 Hei^it Floor to Center Base of Crcwn Height Sieet Ins. Ins. 14 - 34-1/4 14 34-7/8 14-1/2 34 14-1/2 37-5/8 14-1/2 37-5/8 15-1/4 38 15-1/4 38 15-1/4 35 15-1/4 35 Qunney Size Height Indies Feet 8x8 8x8 8x8 8x 12 8 x 12 8 x 12 8 x 12 8 x 12 12 x 12 30 30 35 35 35 35 40 35 40 Opacities based on water temperature rise of 25 F. per hour. "These ratings represent the modmin net loads (240 Btu per sq. ft. steam and 150 Btu per sq. ft. hot veter) that nay be connected to the boiler. Allowances have been made in those ratings for normal piping (covered) and pick-up loads and for heating danestic hot water whoi not more tiein twi bathrooms are to be served, or if the use of domestic hot water does not exceed 75 gallons in 24 hours. /Recoomended load sq. ft. E.D.R. Represents attached load - including piping - which may be placed 00 Boiler in accordance with accepted installation standards for economical operation. 25838 boiler No. IDEAL MAGAZINE BOILER NO. 15 (1933 - 1937) 21 "Installed Firing Firing fediation Grate Rate fete Sq.Ft. Area Lbs.Per Lbs.fer tfeter Sq.Ft. Hour Hour /4 Floor Area Occupied Inches Fire Box Dimensions feter Inches Line Width Length Ins. Hei^at Floor to Center Base of Gown Height Sieet Ins. Ins. Qiinney Size Heigh Indies Feet 15-S or W-04 15-S or W-<6 15-S or W-06 15-S or W-C7 15-S or W-06 400 550 700 850 1000 640 880 1120 1350 16D0 1.82 2.60 3-38 4.16 4.54 33-3/4 x 27 33-3/4 x 33 33-3/4 x 39 33-3/4 x 45 33-3/4 x 51 40-5/8 40-5/8 40-5/8 40-5/8 40-5/8 None II H II fl 8x8 8 x 12 8 x 12 8 x 12 12 x 12 35 35 40 40 45 25-S or W-05 25-5 or W-06 25-S or VMJ7 25-S or W-06 25-S or W-09 25-S or W-10 IDEAL MAGAZINE BOILER NO. 25 (1933 - 1937) 750 900 1200 1500 1800 2100 1200 1440 1920 2400 2860 3360 3-35 4.3 5.25 6.2 7.15 8.1 42-1/2 x 29--1/4 42-1/2 x 35-1/4 42-1/2 x 41-1/4 42-1/2 x 47-1/4 42-1/2 x 53-1/4 42-1/2 x 59-1/4 43-1/4 43-1/4 43-1/4 43-1/4 43-V4 43-V4 None It It M It tl 8 x 12 8 x 12 12 x 12 12 x 12 12 x 12 12 x 16 35 35 35 40 40 45 S or W-92-7 S or W-92-8 S or W-92-9 S or W-92-10 S or W-92-11 S or W-92-12 1450 168C 1900 2130 2370 2600 2320 2690 3040 3410 3790 4260 NO. 92 IDEAL OIL BOILER (JACKETED) (1935 - 1942) e 35-5 40.6 45.8 51.0 56.2 61.3 42-y4 x 97 42-3/4 x 63 42-3/4 X 69 42-3/4 X 75 42-3/4 x 81 42-3/4 x 87 29 x 35-I/2 29 x 41-1/2 29 x 47-1/2 29 x 53-1/2 x 59-1/2 29 x 65-1/2 52-3/4 52-3/4 52-3/4 52-3/4 52-3/4 52-3/4 None 11 II II " It 33 33 33 33 33 33 33hsed on Coal of 19,700 Btu per lb. 12 X 12 12 x 12 12 x 16 12 x 16 12 x 16 12 x 16 35 35 40 40 45 45 SC or hC-92-7 SC or IC-92-8 SC or hC-92-9 SC or MC-92-10 SC or (C-92-11 SC or VC-92-12 1450 1680 1900 2130 2370 2600 NO. 2320 2690 3040 3410 3790 4160 92 IDEAL, STOKER BOILER (JACKETED) (1935 - 1942) IM 55 62 42-3/4 x 57 29 x 35-1/2 42-3/4 x 63 29 X 41-1/2 5^4 52-3/4 None It 71 42-3/4 x 69 29 x 47-1/2 52-3/4 tl 80 42-3/4 x 75 29 x 53-1/2 52-3/4 n 88 42-3/4 x 81 29 X 59-1/2 52-3/4 It 97 42-3/4 x 87 29 X 65-1/2 52-3/4 it 33 33 33 33 33 33 3fesed cn Coal of 13,000 Btu per lb. 12 x 12 12 x 12 12 x 16 12 x 16 12 x 16 12 x 16 35 35 40 40 45 45 "These ratings represent the namun net lends (240 Btu per sq. ft. steam and 150 Btu per sq. ft. bot water) that may be connected to the boiler. Allowances have been unde in these ratings for norml piping (covered) and pick-up loads and for heating domestic hot water when not more than two bathrooms are to be served, or if the use of domestic hot water does not exceed 75 gallons in 24 hours. r^Reooninaided load sq. ft. E.D.R. Represents attached load - including piping - which my be placed 00 Boiler in accordance with accepted installation standards for economical operation. 25839 22 NO. 7 IDEAL BOILER (1937 - 1941) Boiler No. "Installed Firing Firing fedinticu Orate fete fete inaa 1 Ppt* lbc ftor Steam Water-Sq.Ft. Hour Hour Floor Area fW^mirvi Inches Fire Box Dimensions Width length feter 1 ^_ Base Ins. Ins. Heigit Floor to Center 1of Clown Sicct Ins. CLii c:-.. H"' -*-,t Inches Foot S or #-7U S or #-715 S or #-719 S or #-723 S or #-727 S or #-731 S or *-735 S or #-739 220 350 1.68 320 510 2.15 410 655 2.62 500 800 3.09 590 945 3-56 670 1070 4.03 750 1200 4.50 820 1310 4.97 Coal (Hand Fired) 29-1/2 x 16-1/8 29-1/2 x 21-5/8 29-1/2 x 25-1/8 29-1/2 x 26-5/8 29-1/2 x 32-1/8 29-1/2 x 35-5/8 29-1/2 x 39-1/8 29-1/2 x 42-5/8 18 x li-5/8 46-3/4 38 x 15 46-3/4 18 x 18-7/16 46-3/4 IS x 22 46-3/4 18 x 25-7/16 46-3'4 18 x 29 46--3/4 18 x 32-7/16 46-3/4 18 x 36 46-3/4 12-1/4 12-1/4 12-1/4 14/-1/4 12-1/4 12-1/4 12-1/4 12-1/4 32-1/4 32-1/4 32-1/4 32-1/4 32-1/4 32-1/4 32-1/4 32-1/4 8x8 8x8 8x 8 8 x 12 8 x 12 8 x 12 12 x 12 12 x 12 30 30 35 35 35 35 35 40 S or #-715-0 S or #-719-0 S or #-723-0 S or #-727-0 S or #-731-0 S or #-735-0 S or #.739-0 340 410 480 550 620 690 760 545 655 770 880 990 1105 1215 0 8.0 9.5 10.5 12.0 13.5 14.5 16.0 ^ased on oil of 19.700 Btu per Lb. Oil Fired 29-1/2 x 21-5/8 29-1/2 x 25-1/2 29-1/2 x 28-5/8 29-1/2 x 32-V8 29-1/2 x 35-5/8 29-1/2 x 39-1/8 29-1/2 x 42-5/8 18 x 15 46-3/4 18 x 18-7/16 46-3/4 18 x 22 46~y4 18 x 25-7/16 46-34 18 x 29 46-3/4 18 x 32-7/16 46-3/4 18 x 36 46-3/4 12-1/4 12-1/4 12-3/4 12-1/4 12-1/4 12-1/4 12-1/4 32-1/4 32-1/4 32-1/4 32-1/4 32-1/4 32-1/4 32-1/4 8x8 8x8 8x8 8 x 12 8 x 12 8 x 12 8 x 12 30 30 30 30 30 35 35 SC or WG-919 SC or M3-92S SC or VO-927 SC or WC-931 SC or VO-935 SC or VO-939 410 490 570 650 730 810 655 785 910 1040 1170 1295 m 17.0 20.0 22.0 25.0 17.0 30.0 s^ksed an Coal of 12,500 Btu per Ub. Stoker Fired 29-3/2 x 25-1/2 29-1/2 X 28-5/8 29-1/2 x 32-1/8 29-1/2 x 35-5/8 $-1/2 x 39-1/8 29-1/2 x 42-5/8 18 x 18-7/16 46-3/4 18 x 22 46-3/4 18 x 25-7/16 46-3/4 18 x 29 46-3/4 18 x 32-7/16 46-3'4 18 x 36 46-3/4 12-1/4 12-1/4 12-1/4 12-1/4 12-1/4 12-1/4 32-1/4 32-1/4 32-1/4 32-1/4 32-1/4 32-1/4 8x8 8x8 8 x 12 8 x 12 8 x 12 8 x 12 30 3) 30 30 35 35 S or #-0411 390 625 S or #-0511 480 770 S or #-0611 560 895 S or #-0711 640 1025 S or #-0811 730 1170 S or #-0911 8L0 1295 NO. 11 IDEAL OIL BOILER (JACKETED) (1938 - 1942) 8.5 10.3 12.1 13.5 14.9 16.3 U 29-3/4 X 24 29-3/4 X 27-1/2 29-3/4 X 31 $-3/4 X 31-1/2 29-3/4 X 31 29-3/4 X 41-1/2 18 x 15 47-1/4 18 x 18-7/16 47-1/4 18 x 22 47-1/4 18 x 25-7/16 47-1/4 18 x 29 4721/4 IS x 32-7/16 47-1/4 12-1/4 12-1/4 12-1/4 12-1/4 12-1/4 12-1/4 32-1/4 32--1/4 32-1/4 32-1/4 32-1/4 32-1/4 8x8 8x8 8x8 8 x 12 8 x 12 8 x 12 30 30 30 35 35 35 Based on oil of 19,700 Btu per lb. //Dimensions apply bo flush jacket, Fbr extended jacket add 23-3/4" to last figure. **Tbese ratings represent the raxinua net loads (240 Btu per sq. ft. steam and 150 Btu per sq. ft. hot water) that any be connected to the boiler. ALLoences have been nude in these ratings for normal piping (oov^red) and pick-up loads and for heating dcnestic hot water when not more Ufin two bathrooms are to be served, or if the use of domestic hot teter does not exrxed 75 gallons in 24 hours. 25840 NO. 24 IDEAL ARCOFIRE STOKER BOILER (1938 - 1942) Boiler No. SC or WC-824 3C or VC-924 3C or VC-1024 SC or VC-1124 SC or VC-1224 SC or VC-1324 `^Installed Firing Radiation Grate fete 0 Sq-fV Area Lbs.Per Steam Water Sq.Ft. Hour 900 1440 1075 1720 1250 2000 1425 2280 1600 2560 1775 2840 Firing fete Lbs. Per Floor Area Occupied Hour Indies oe 34 42-3/4 x 57 41 424-3/4 x 63 47 42-3/4 x 69 53 42-34 X 75 60 42-3 4 x 81 66 42-3/4 x 87 Fire Box Dimensions Water Indies Line Width Length Ins. @ 24 x 19-1/2 50-3/4 24 x 24-1/2 50-3/4 24 x 24-L'2 50-3/4 21 x 29- L 2 50-3 4 21 x 24-1/2 50-3./4 21 x 29-1/2 50-3/4 fkse Hei^it Ins. gy 12-1/2 12-1/2 12-1/2 12-1/2 12-1/2 12-1/2 Hei^it Floor to Center of Crwn Sheet Ins. Chimney Size Heiri't Inches Feet 23 12 x 12 40 13 12 x 12 40 23 12 x 16 45 12 x 16 45 23 12 X 16 45 23 12 x 16 50 S Mininum ranges to 57-S^4" depending on fese Height. (y@ Minima fenges to 19-1/2". / Distance from Gotten V&ter Leg to Crown 3ieet. * Based on Coal of 13,000 Btu per Lb. S or W-64 S or W-65 300 4fcs0 375 600 NO. 6 IDEAL OIL BOILER TUXEDO OIL BOILER (1940 - 1942) H 44-5/8 X 24-3'4 11-1/8 x 10 52-5/8 x 24-3'4 14-1/8 x 10 43 42 8x8 8x6 25 25 H Dimensions o*' Refractory EHck Chamber ** These ratings represent the maximum net loads (210 Btu per sq. ft. steam and 150 Btu per sq. ft. hot water) that ray be connected to the boiler. Allowances have been made in these ratings for normal piping (covered) and pick-up loads and for heating domestic bot water when not more than tw bathrooms are to be served, or if the use of domestic hot water does not exceed 75 gallcxis in 24 hours. NO. 1-G STANDARD GAS BOILER (1928 - 1955) Boiler No. Installed Radiation Sq. Ft. Steam Water Floor Area Occupied Inches A.G.A. Input Mill Water Line Inches Chinney Diameter Height Inches Feet 1-G-S or Vf-4 1-G-S or W-5 1-G-S or VP-6 1-G-S -or VP-7 1-G-S or VP-8 1-G-S or W-y 1-G-S or VP-10 395 530 670 810 950 1095 1240 715 960 1200 1440 1675 1915 2160 19 x 25 23 x 25 27 x 25 31 x 25 35 x 25 39 x 25 43 x 25 180 240 300 360 420 480 540 30 30 30 30 30 30 30 6 20 7 20 8 20 6 2(J 9 20 y 20 9 20 Note: Ratings shown are for installations at eLevations up to 2000 ft. All ratings are for Natural Manufactured, Mixed, LP and LP-Air gases. 25841 24 NO. 4-G STANDARD GAS B0HR (1928 - 1955) Boiler No. Installed Radiation o Sq. Ft. Steam Water Floor Area Occupied Inches A.G.A. Input ru3! Water Line luciies Oiimney Diameter Height Inches Feet 4r-G-S or W-6 4-G-S or W-7 4-G-S or W-8 4-G-S or W-9 4-G-S or W-10 4-G-S or W-ll 4-G-S or W-13 4-G-S or W-15 4-G-S or W-17 4-G-S or W-19 4-G-S or W-21 4-G-S or W-22 1390 1690 1995 2300 2610 2935 2400 2880 3355 3835 4315 4795 3570 4230 4895 5565 6205 6520 5760 6765 7825 8895 9920 10435 27 x 41-1/2 31 x 41-1/2 35 x 41-1/2 39 x 41-1/2 43 x 41-1/2 47 x 41-1/2 61-1/4 x 41-1/2 69-1/4 x 41-1/2 77-1/4 x 41-1/2 85-1/4 x 41-1/2 93-1/4 x 41-1/2 103-1/2 x 41-1/2 600 720 840 960 1080 1200 1440 1680 1920 2160 2400 2520 43 43 43 43 43 43 43 43 43 43 43 43 9 20 10 20 11 20 11 20 12 20 12 2U 13 20 14 20 15 20 16 20 17 20 17 20 4-G-S or W-25 4-G-S or W-28 4-G-S or W-31 4-G-S or W-33 4-G-S or W-37 4-G-S or W-41 7455 8385 9315 9940 11180 12420 11905 13405 14880 15875 17840 19840 115-1/2 x 41-1/2 127-1/2 x 41-1/2 139-1/2 x 41-1/2 153-3/4 x 41-1/2 169-3/4 x 41-1/2 185-3/4 X 41-1/2 2880 3240 3600 3840 4320 4800 43 43 43 43 43 43 18 20 19 20 20 20 20 20 22 20 24 20 Note: Ratings shown are for installations at elevations up to 2000 ft. All ratings are for Natural, Manufactured, Mixed, LP and LP-Air gases. Radiator Height Inches 15" 18" 20" 22" 1 Column Width 5-3/8" Centers 1-1/2" 1-1/2 Sq. Ft. per section 0.600 Sq. Ft. lineal inch per PEERLESS COLUMN RADIATOR (1901 - 1925) 2 Column Width 8-1/4" Centers 2-1/2" 3 Column Width 9-3/4" Centers 2-1/2" 1-1/2" Sq. FI. per section 0.6 Sq. Ft. per lineal inch 2-1/4 Sq. Ft. per section 0.9 Sq. Ft. per lineal inch 2 Sq. Ft. per section 0.800 Sq. Ft. per lineal inch 3 Sq. Ft. per section 1.2 Sq. Ft. per lineal inch 4 Column Width 11-1/4" Centers 3" 3 Sq. Ft. per section 1.0 Sq. Ft. per lineal inch 4 Sq. Ft. per section 1-333 Sq. Ft. lineh.1 inch pe 25842 Radiator Height Inches 1 Column Width Jj-3/8" Centers 1-1/2" PEERUSSS COLUMN RADIATOR (1901 - 1925) 2 Column Width 8-1/4" Centers 2-1/2" 3 Column width 9-3/4" Centers 2-1/2" 4 Column Width 11-1/4" Centers 3" 23" 1-2/3 Sq Ft. 2-1/3 Sq. Ft. per section per section 0.667 Sq. Ft. per 0*933 Sq. Ft. per lineal inch lineal inch 26" 2 Sq. Ft. 2-2/3 Sq. Ft. 3-3/4 Sq. Ft. 5 Sq. Ft. per section per section per section per section .800 Sq. Ft. per 1.067 Sq. Ft. per 1.5 Sq. Ft. per 1.667 Sq. Ft. pe lineal inch lineal inch lineal inch lineal inch 32" 2-1/2 Sq. Ft. 3-1/3 Sq. Ft. 4-1/2 Sq. Ft. 6-1/2 Sq. Ft. per section per section per section per section 1 Sq. Ft. per 1.333 Sq. Ft. per 1.8 Sq. Ft. per 2.167 Sq. Ft. lineal inch lineal inch lineal inch lineal inch 38" 3 Sq. Ft. 4 Sq. Ft. 5 Sq. Ft. 8 Sq. Ft. per section per section per section per section 1.2 Sq. Ft. per 1.6 Sq. Ft. per 2.0 Sq. Ft. per 2.667 Sq. Ft. lineal inch lineal inch lineal inch lineal inch 45" 5 Sq. Ft. 6 Sq. Ft. 10 Sq. Ft. per section per section per section 2 Sq. Ft per 2.4 Sq. Ft. per 3*333 Sq. Ft. lineal inch lineal inch lineal inch Height Inches 13-5/16 13-5/16 13-5/16 PEERLESS WALL RADIATOR (1920 - 1953) TYPE A Length or Width Inches 16-5/8 21-7/8 29-1/16 Thickness Inches 2-7/8 2-7/8 2-7/8 Heating Surface Square Feet 6 8 11 Height Inches 8 PEERLESS BATHROOM RADIATOR (1920 - 1948) Length Inches 20-1/2 L. 1 :i i Thickness Inches 1-1/2 Heating Surface Square Feet 4-1/2 25843 26 CORTO RADIATORS (192? - 1942) Radiator Height Inches 3 Tube Width 4-6/8" Centers 2-1/2" 4 Tube Width 6-5/16"Centers 1/2" 5 Tube Width 8" Centers 2-1/2" 6 Tube Width 9-11/16" Centers 2-1/2" 7 Tube (Window) W< J i V H4 c\ /mt Centers 2-1/2" 20" 23" 26" 32" 38" 14" 17" 1-3/4 Sq. Ft. per section 0.7 Sq. Ft. per lineal inch 2 Sq. Ft. per section 0.8 Sq. Ft. per lineal inch 2-1/4 Sq. Ft. per section 0.9 Sq. Ft. per lineal inch 2-1/2 Sq. Ft. per section 1.0 Sq. Ft. per lineal inch 2-2/3 Sq. Ft. per section 1.178 Sq. Ft. per lineal inch 3 Sq. Ft. per section 1.2 Sq. Ft. per lineal inch 3 Sq. Ft. per section 1.2 Sq. Ft. per lineal inch 3-1/2 Sq. Ft. per section 1.4 Sq. Ft. per lineal inch 3-2/3 Sq. Ft. per section 1.467 Sq. Ft. pe lineal inch 2-1/3 Sq. Ft. per section 0.933 Sq. Ft. per lineal inch 2-3/4 Sq. Ft. per section 1.1 Sq. Ft, per lineal inch 3-1/2 Sq. Ft. per section 1.4 Sq. Ft. per lineal inch 4 Sq. Ft. per section 1.6 Sq. Ft. per lineal inch 3 Sq. Ft. per section 1.2 Sq. Ft. per lineal inch 3-1/2 Sq. Ft. per section 1.4 Sq. Ft. per lineal inch 4-1/3 Sq. Ft. per section 1.733 Sq. Ft. per lineal inch 5 Sq. Ft. per section 2.0 Sq. Ft. per lineal inch 3-1/2 Sq. Ft. per section 1.4 Sq. Ft. per lineal inch 4-1/4 Sq. Ft. per section 1.7 Sq. Ft. per lineal inch 5 Sq. Ft. per section 2.0 Sq. Ft. per lineaL inch 6 Sq. Ft. per section 2.4 Sq. Ft. per lineal incli 2-1/2 Sq. Ft. per section 1.0 Sq. Ft. per lineal inch 3 Sq. Ft. per section 1.2 Sq. Ft. per lineal inch Radiator Height Inches 2Q" 23" CORTO HOSPITAL RADIATOR (1927 - 1942) 3 Tube Width 4-5/8" Centers 3" 1-3/4 Sq. Ft. per section 0.583 Sq. Ft. per lineal inch 2 Sq. Ft. per section .667 Sq. Ft. lineal inch per 5 Tube Width 8" Center 3" 2-2/3 Sq. Ft. per section 0.889 Sq. Ft. lineal inch per 3 Sq. Ft. per section 1.0 Sq. Ft. per lineal inch 25844 CORTO HOSPITAL RADIATOR (1927 - 1942) (Cont'd.) ISUkVJ A C* OS/ t Height ` Inches ~ 26" 32" 38" JO 1-\--.Vo- Width 4-5/8" Centers 3" 2-1/3 Sq. Ft. per section 0.778 Sq. Ft. per lineal inch 3 Sq. Ft. per section 1.0 Sq. Ft. per lineal inch 3-1/2 Sq. Ft. per section 1.167 Sq. Ft. per lineal inch s Tii Kp Width 8" Center 3" 3-1/2 Sq. Ft. per section 1.167 Sq. Ft. lineal inch per 4-1/3 Sq. Ft. per section 1.444 Sq. Ft. per lineal inch 5 Sq. Ft. per section 1.667 Sq. Ft. per lineal inch Radiator Height Inches 19" 22" 25" 32" ARCO RADIATOR (1-1/2" Center) (1930 - 1939) 3 Tube Width 3-1/2" 1.1 Sq. Ft. per section 0.733 Sq. Ft. lineal inch per 1.3 Sq. Ft. per section 0.867 Sq. Ft. per lineal inch 1.6 Sq. Ft. per section 1.067 Sq. Ft. lineal inch per 4 Tube Width 4-3/4" 1.6 Sq. Ft. per section 1.067 Sq. Ft. per lineal inch 1.8 Sq. Ft. per section 1.2 Sq. Ft. per lineal inch 2.0 Sq. Ft. per section 1.333 Sq. Ft. lineal inch per 6 Tube Width 7-7/S" 2.3 Sq. Ft. per section 1.467 Sq. Ft. lineal inch per 3.0 Sq. Ft. per section 2.0 Sq. Ft. per lineal inch 3-7 Sq. Ft. per section 2.467 Sq. Ft. per lineal inch ARCO SUNRAD (1938 - 1950) 2" Centers Depth Height Heat Emission Sq. Ft. per section 5 7-1/2 10 23 2 3 BASEBOARD RADIANT PANEL (1947 - 195D TTPE R Depth Height Heat Emission Sq. Ft. per Lineal Foot 2-1/b" 8" 1.25 25845 I < A^ERiCAN-^taitdard PLUMBING AND HEATING DIVISION A*/5D!C AM BAOIATOR & STANDARD SANITARY CORPORATION NEW YORK I 8. NEW YORK 25846 <1 lorn No 706- 2 !