Document LmJ9d947wKa8vEbXZezo2pe3
Heai-Surface (Fan System)
The G & O Manufacturing Company
138 Winchester Avenue
New Haven, Connecticut
INDIVIDUAL FIN TUBING
RADIATING ELEMENTS FOR UNIT HEATERS (High and Low Pressure) AND CONCEALED RADIATORS
INDUSTRIAL HEATING COILS REFRIGERATING CONDENSERS
EVAPORATORS, INTERCOOLERS, AFTERCOOLERS, COOLING COILS AND OTHER HEAT TRANSFER PRODUCTS
Individual G & O Fins--The use of individual fins results in high efficiency in heat transfer from primary tube surface to secondary fin surface, because all G & O fins have ample collars around the tube opening insuring liberal contact with tubing.
Any Size or Shape--Fins of any size or shape may be obtained giving any desired proportion of
primary and secondary radiating surface.
Square Fins--A square fin has about 30% greater surface than a round fin of a diameter equal to a side of the square.
along tubes.
Individual Fins--Individual fins permit of any fin spacing: also, of using fins in groups at intervals Fins placed at practically any angle on tubes.
Various Shapes--G & O individual fin tubing is furnished in straight lengths: in U bends with short radii: in continuous return bend coils(`or other shapes. Ends of tubes may be left free of alloy for mechanical joints.
G & O Individual Fin Tube Data
Standard Sizes
Fin Surface
O.D.
Fin Spacing
of Tube
Size
*
Linear Foot
'/ */'
6 0.55 aq. ft.
w '/' 1.
6 0.80 sq. ft.
>/.* Vi' r'd. . 6 0.60 aq. ft.
>/.' I'/z' r'd-
6 1.55 >q. ft.
Vf.
W -q-
6 2.40 aq. ft
1* W q.
6 4.00 aq. ft.
Pioneer Manufacturers of Individual Fin Tubing in this Country
822
Heaters, Unit
Electric Air Heater Company
Division of AMERICAN FOUNDRY EQUIPMENT CO.
Mishawaka, Indiana, U. S. A.
Manufacturers of Industrial and Domestic Electric Air Heaters
Experience of hundreds of users arid many
operation tests by power and public service
interests, insurance companies, United
States Government and other authorative
Front View
institutions have proved that the Electromode Electric Air Heaters are practical
for hundreds of varied applications.
They incorporate the unit heater principle in which forced air circulation provides uniform temperature. They are clean, convenient, instantaneous, efficient, fully
automatic and portable. The low initial ^cost and minimum installation expense ^enables economical heating for many
applications.
The heart of the Electromode Heater is the
I heating unit. This consists of a helicoil,
sheathed wire type (Galrod) of resistance
heater element cast integral with an
Heater Element_____________
aluminum alloy fin type grkK The heat
Back View transformed from electric energy is quickly
Industrial Eleclromode AU-Electric Unit Heater
conducted through the finned area of the
heating unit and is carried off by the forced
Eledromode "Built-in-Wall'' air circulation. The operating tempera
AU-Eleciric Heater
ture of the unit is comparatively low and
with the special cut-out switch, absolute
Eledromode Portable
safety is assured.
AU-Eledrii Heater
In addition to the industrial type, the
Electromode Heaters are made in domestic
models. The "built-in-wall" type and the
portable model are both ideal for home use
where occasional heat is required.
Write us for complete information on the Electromode Line of heaters
Mode! No.
85-12 83-15 83-18
84-20 84-24 84-30 84-40
12-6 12-9 12-12
18-135 18-1575 18-18 18-27
24-36 24-42 24-18 24-60
INDUSTRIAL TYPE
K.W.
1.2 1.5 . 1.8
2.0 2.4 3.0 4.0.
6.0 9.0 12.0
13.5. 15.75 18.0 27.0
36.0 42.0 48.0 60.0
C.F.M.
75 95 95
150 150 210 210
375 560 625
1055 1055 1055 1410
2815 2815 3130 3130
B.T.U.
4,098 5,122 6,147
6,830 8,196 JO,245 13,660
20,490 30,735 40,980
46,102 53,786 61,470 92,205
122,940 143,430 163,920 204,900
RATINGS
"BUILT-IN-WALL** TYPE
E.D.R.
17.1 21.3 25.7
28.5 34.2 42.7 57.0
85.4 128.0 170.8
192.1 224.1 256.1 384.2
5(1.8 597.6 683.0 853.8
Model
A1200 A1600 A2000 B3000
K.W.
1.2 1.6 2.0 3.0
C.F.M.
110 110 110 180
B.T.U. ; E.D.R.
4,098 ' 5,464 6,830. 10.245
17.1 22.8 28.5 42.7
All models supplied either for'2 . in. by 4 in. or 2 in. by 6 in. stud mountings.
ELECTROMODE--PORTABLE TYPE
Model
AI5 A20
B30 B40 B50
K.W.
1V2 2
3 4 5
B.T.U.
5,118 6,824
10,236 13,648 17,060
C.F.M.
76 100
150 200 250
E.DJL
21.3 28.4
42.7 56.9 71.1