Document LgoaO7zy29Vo6kLGDRqO89pq5
Oil Burners
Heating System wt Heaters
9*
-Air Conditioning Unit
Ray Oil Burner Co.
Since 1872
1301 San Jose Avenue San Francisco 12,;Cal.
Distributors in All Principal Cities of the World
Atlantic Seaboard Division 629 Grove Street
Jersey City 2, N. J.
Consult your local Telephone Directory
Products: A complete line of Horizontal Rotary and Pressure Atomizing Oil Burners;'
Combination Oil-or-Gas Burners; Industrial Gas Burners; Oil Burning Water Heat ers ; Winter Air Conditioning Units, Commercial Ranges.
Oil Burners
Heating Systems water Heaters Air Conditioning Unit
Ray Oil Burner Co.
Since 1872
1301 San Jose Avenue San Francisco 12, Cal.
Atlantic Seaboard Division 629 Grove Street
Jersey City 2, N. J.
There is a RAY Burner for every Heating Purpose.
RAY COMBINATION OIL-GAS BURNER
1 to 1000 Boiler hp Type AG. Manual, Semi-Au tomatic,
RCR for St otl, manual operation.
Steam Turbine Drive, Type TG, all grades oil.
Tested and approved for
U. S. Navy Service.
Four, 8 oven, fully auto matic oil Ranges,
RAY HORIZONTAL ROTARY OIL BURNERS
Built in fully automatic, semi-automatic and manual types;
in sizes from 1 to 1000 Boiler hp; to burn all grades of fuel oil.
Standard models include both direct and belt drives--the
latter being recommended for use where other than 50 or 60
Cycles AC, or only DC is available. Types for straight elec-
Type ARJP, Fully Au . trie or straight gas ignition; pump or gravity feeds. Direct
tomatic for heavy oil drive types include a steam turbine driven model.
where gae for ignition not ' available.
All fully automatic types for heavy oil incorporate the Ray Dual Pump and Reservoir, with the Ray VISCOSITY Valve,
a patented, exclusive feature which automatically meters the
correct amount of fuel at all times, regardless of changes in
viscosity of the oil due to temperature variations. All larger
sizes employ dual ignition system, consisting of dual high-volt
age transformers, dual electric ignitors and dual gas valves.
Fully automatic sizes 9 and 10 include as standard equipment
electronic pilot and flame failure control.
RAY PRESSURE ATOMIZING OIL BURNERS Fully automatic, for No. 2 oil or lighter. AC or DC; capaci ties to 18 gal/hr.
RAY WINTER AIR CONDITIONING UNITS Built in four sizes, with input capacities of 105,000, 140,000, 230,000, 350,000, 450,000 Btu.
RAY OIL WATER HEATERS Four sizes. Capacities: 35, 45, 60 and 75 gal. Maximum recover rates: 100 to 240 gph.
Type. AR144 Size 10 for No. 6. oil. Available in 10 sizes from t to 810 gph.
RAY OIL FIRED RANGES Seven sizes for manual or fully automatic operation.
Type BR-141, Belt Drive
Automatic.
to 100
gph.
Ray OH Furnace, Winter Air Conditioning Unit.
Small capacity CK to gph) rotary burner.
1390
Fully Automatic, Type JP, Si or lighter oH
ARC-181 Model 50 for Low Pressure Gas
Combination OH and High Pressure Gas, Type AR-HN.
Type XPJC for Low Pressure Gas
ARC-MODEL 50. This burner consists of a rotary type oil burner of Ray conventional design coupled with a gas housing for low pressure gas, from 2 in. WC to 10 in. WC. The gas burner parts provide for the introduction of gas in a manner which fully utilizes the energy in the high pressure air supplied by the rotary burner fan. Gas and primary air are intimately combined, in two stages, before mixing with the secondary air which is introduced through a vaned annular opening concentric with the nozzle. Change from one fuel to the other requires less than one minute. Avail able in ten sizes; in capacities to 31,500,000 Btu/hr.
TYPE HN for gas pressures above 1 lb/sq in. may be used alone or in combina tion with a Ray Oil Burner. Built in eleven sizes; in capacities to 43,000,000 Btu/hr.
TYPE XPJC. Combination gas-oil burner of the pressure atomizing type. Available in three sizes; in capacities from 560,000 to 2,500,000 Btu/hr.
HOURLY CAPACITY RATINGS of RAY OIL BURNERS
Burner Size
JP XPJ XPJ-1
XP-2
0000 000 00 0
1 % 8
51 0 it 72 88
9 .10
12
8
V 7
1 1
Mo H
tor .P
.
Oil Capacity U. S. Gallons
Min.
1 1 3 8
Max.
3 4 8 18
Equivalent Boiler HP
Min.
3 3 9 25
Max.
9 12 25 56
0.5 2.5
2
8
0.5 2.5
2
8
1 2.5 3
8
25
7 16
4 11
5 15 8 22
13 35
17 50 27 72
10 33 12 50
15 67 25 100
35 110 40 165 50 . 225
85 335
35 150
120 500
50
210
' 165.
700
75 320 . 250 1000
Equivalent Lbs. Steam Generated
Min. Max.
110 325 110 430 325 865 865 1950
60 290
60 290 no 290
230 580
460 1250 580 1720
930 2500
1150
1400 1720
2900
3800
5800 7750 11500
4000 . 5800
8700
17400 24400
37000
Heat Capacity
Input Thou. Btu Oil or' 3000 Btu Gas
Min.
Max.
140 420
140 560 420 1120
1120 2500
Equivalent Sq. Ft Steam Radiation
Min.
438 438 1310 3500
Max.
1310 1750 3500 7900
75 375 234 1170 75 375 234 1170 150 375 469 1170 300 750 938 2350
600 1650 1870 5170
750 2250 2350 7030
1200
3300
3750
10,300
1500 1800 2250 3750
5250 7500 11250
4950 7500 10000 15000
22500 31500 48000
4690 5620 7030 11700
_
--
--
15500 23400 31400 46900
__
--
NOTE: The6e ratings are predicated upon specific conditions o! drift and furnace volume. It may be per missible, under desirable conditions, to operate at higher rates, or advisable under restricted condi tions, to operate at reduced rates. Heating capacities are based upon 150,000 Btu per gal of oil for rotary burners and 140,000 Btu per gal of oil for pressure atomising burners and upon an overall boiler efficiency of 75 per cent.