Document LgmeEBZ6qbnZGb7e2o3MeNd45
10
^CC
Monsanto
','*'"*'**4loCA"ON|
G. C. Chesnut - Texas City
OATf June 9, 1983
SOMCT KtftftfNCf
MAY SAFETY MEETING Dept. 33
TO K. E. Bretz
cc. A. H. Conrad M. J. Leidy R. T. Hammann
The subject of the May safety meeting was "Unsafe Acts". Slides of unsafe acts were shown and discussed.
Procedure bulletin No. P-0115 was also reviewed at this time.
/jP
ATTENDED:
Scott Boggess White Tovrea Prendergass Lemons Rains Lessa Lingenfelter Holcomb Heer Nelson Thomas
6'-/\ _C George Chesnut
/
LAM001235 SC
000038
PROCEDURE BULLETIN--TEXAS CITY PLANT P-0115
FLAMMABLE AND COMBUSTIBLE LIQUIDS STORAGE AND DISPENSING AREAS
t"'
I. PURPOSE
The purpose of this bulletin is to establish a procedure for dispensing and storage of flammable and combustible liquids.
II. SCOPE
This bulletin covers the responsibility and an acceptable method for storage and dispensing of flammable and combustible liquids. Flammable liquids have flash points below 100F, combustible liquids have flash points above 100F. See paragraph IV, B. for details.
III. POLICY AND RESPONSIBILITY
All Manufacturing units. Stores Department, Process Technology Department and any other department storing and dispensing flammable and combustible liquids have the individual respon sibility to see that these liquids are stored and dispensed in a safe and proper manner.
IV. PROCEDURE
''
A. Drum Storage
1. Drums used for dispensing flammable or combustible
liquids which are mounted in a horizontal position
must be equipped with self-closing valves, relief vent
devices, ground connections and individual drip pans
equipped with safety screens or filled with absorbent
material. Some means.of protecting drip pans from over
flowing because Of rain must be provided. Drip pans
should be emptied on a routine basis.
-
2. -------------
Drums mounted vertically and equipped with hand operated pumps do not require a drip pan, but must have relief vent devices, grounds and tops should be protected from weather.
3. All drums used for dispensing flammable liquid must be located away from operating equipment by a minimum distance of 20 feet. They must be located on a non absorbent floor.
4. Flammable liquids in excess of one quart dispensed from drums should be carried in safety cans equipped with suitable screens. The can being filled should be bonded to the grounded drum while filling.
\
SC 000039
ORIGINAL ISSUE: 10/1/76 REVISED:
PAGE JL0FJ_
LAM001236
PROCEDURE BULLETIN--texas city plant p~0115
FLAMMABLE AND COMBUSTIBLE LIQUIDS STORAGE AND DISPENSING AREAS
5. Locations for storage and dispensing of flammable liquid should be situated to provide adequate natural ventilation. -Vj
If this is not possible, mechanical ventilation should be 77* provided.
6. Suitable fire control devices must be available where flammable liquids are dispensed.
7. All drums must be labeled as to chemical content.
B. Storage Other Them Drums
Laboratories at this location may store up to 2 gal/100 ft.2 .
of floor space of Class I flammable liquids. An additional 2 gal/100 ft.2 may be stored in safety cans or approved storage
cabinets. Quantities of Class II and III combustible liquids
may also be stored such that the total for Classes I, II and III does not exceed 4 gal/100 ft.2 in bottles or 8 gal/100 ft.2
if half of it is in approved safety cans or cabinets. In addi tion, 1 gallon of acetone in an approved plastic bottle is permitted and is excluded from the above totals. Any devia
tion from this provision will require written authorization
from the Department Head or Manufacturing Superintendent and
the Loss Prevention & Safety Department. The roost flammable liquids, Class IA, should be limited to
)
*
no larger than 1 pint in glass or approved plastic bottles. Class IB is limited to a maximum of 1 quart.
' V
EXAMPLES
,v". ..
.. .
Class IA, Flash point <73F, Boiling point <100F
Ethyl ether
Pentane
... ~ :
.
s. -V
~
__Class IB, Flash point <73F, Boiling point >100F
Acetone Benzene Carbon disulfide
Hexane Ethyl Alcohol
Class IC, Flash point 73F-100F
Turpentine * Xylene
000040
ORIGINAL ISSUE: 10/1/76 REVISED:
PAGE _L0F_L LAM001237
PROCEDURE BULLETIN--texas city plant p-ons
FLAMMABLE AND COMBUSTIBLE LIQUIDS STORAGE AND DISPENSING AREAS
V
Class II, Flash point 100-140F
Cellosolve Mineral spirits
Class IIIA, Flash point 140-200F
Class IIIB, Flash point >200F
V. INSPECTION & CONTROL
It is recommended that each individual department set aside ' designated areas for the storage of both drum and less than
drum quantities of flammable liquids. Periodic inspections of these areas should be scheduled to insure that they are being properly used and that quantities stored in labs and buildings are limited as specified above. In addition, the inspection should verify that all containers are properly labeled as to content and that only authorized materials are stored. The inspections should be made at least every six months.
Reviewed by: Plant Managers Safety Board
SC
000041 ORIGINAL ISSUE: 10/1/76 | REVISED?
LAM001238
PAGEJ-OF-L