Document LggepOBEK1pz8716ddmK41VYQ
AR226-2393
C-8 REDUCTION & CONTROL PROGRAMS STATUS
RJZ026555
R. J. Z1PFEL 6-11 -87
003546-19 - 06/09/87 - SJZ;kst
EID09I378
EID137075
MEETING AGENDA
AIM
GROUNDRULES
PLAN POLICY AND GOALS
C-8 SAFETY AND HEALTH INFORMATION
ENVIRONMENTAL CONTROL PROGRAMS
WORK ENVIRONMENT PROGRAMS
- C-8 IN BLOOD HISTORY
- C-8 IN AIR HISTORY
~
`
PATH FORW ARD/ACTION ITEMS
9 CONCLUSIONS
003546-26 - 06/09/87 - RJZ:kst
EID091379
RJZ026556
EID137076
MEETING AIM
TO REVIEW THE FLUOROPRODUCTS C-8 REDUCTION AND CONTROL PLAN THROUGH OPEN DISCUSSIONS AROUND THE HISTORY AND STATUS OF THE C-8 RELATED PROGRAMS TO ASSURE THAT ALIGNMENT BETWEEN CORPORATE SAFETY AND SPD BUSINESS OBJECTIVES CONTINUES.
RJZ026557
003546-20 - 06/03/87 - RJZrkst
EID091380
EID137077
GROUND RULES
HOLD QUESTIONS UNTIL END OF PRESENTATION EXCEPT IF MEANING IS NOT CLEAR.
RJZ026S58
003546-35 - 06/09/87 - BJZ:kst
ETO091381
EID137078
C-8 CONTROL PLAN POLICY AND GOALS
REDUCE PUBLIC EXPOSURE THROUGH THE ECONOMICAL IMPLEMENTATION OF THE OPTIMUM TECHNOLOGIES AVAILABLE
REDUCE EXPOSURE BELOW AEL BY ENGINEERING CONTROLS AND PROTECTIVE EQUIPMENT
REDUCE EXPOSURE BY ENGINEERING CONTROLS AND PROTECTIVE EQUIPMENT SO THAT ELEVATED ORGANIC FLUORINE LEVELS IN BLOOD WILL DECREASE AND ACCUMULATION OF ORGANIC FLUORIDES IN NEW WORKERS WILL BE LIMITED
RJZ026559
003546-27 - 05/19/87 - RJZrkst
EID091382
EID137079
C-8 DATA TO DATE IT IS NOT A TERATOGEN
IT IS NOT AN EMBRYOTOXIN
IT IS NOT A MUTAGEN
IT IS MODERATELY TOXIC - LD 50 540 mg/kg
IT HAS AN ESTIMATED BIOLOGICAL HALF LIFE OF ONE TO THREE YEARS IN HUMAN BLOOD
NO KNOWN REPORTS OF HEALTH RELATED EFFECTS REPORTED BY DuPONT
- 3M HAS HAD ONE EMPLOYEE WITH REVERSIBLE LIVER DAMAGE (UPDATED JANUARY 1987)
003546-2 - 06/09/87 - RJZ:kst
E1D091383
09S9ZQ2FS
EID137080
C-8 EXPOSURE LIMITS
AEL IN AIR
0.56 MOLES PER BILLION
3 0.01 mg/m
BLOOD LEVELS
NONE ESTABLISHED
PUBLIC EXPOSURE LIMITS NONE ESTABLISHED
RJZ026561
003546-21&22 - 06/09/87 - RJZikst
EID091384
EID137081
C-8 HISTORY
8/51 Began use of C-8 in dispersion polymer ization. Few precautions in handling.
6/07/78
Advised personnel that 3M found elevated organic fluorine levels in blood of workers exposed to fluorinated surfactants. Started internal review and monitoring.
9/79 Provisional AEL established by Haskell.
3/20/81
3M advised that C-8 caused birth defects in unborn when fed by stomach tube to female rats. All fem ale employees with potential C-8 exposure were promptly transferred to other plant areas.
4/10/81
C-8 specific blood test developed and put in use.
3/01/82 5/17/82
Studies completed which found C-8 not to be a teratogen and no adverse health effects.
3 Final AEL established at 0.01 mg/m or 0.56 ppb.
8/85 First commercial shipment of TBSA from Chambers Works.
12/86
Demonstrated feasibility in the laboratory to economically concentrate C-8 in water solutions.
003546- - 06/09/87 - BJZ:kst
EID091385
RJZ026562
EID137082
C-8 ENVIRONMENTAL CONTROL PROGRAMS STATUS VERSUS 1984
AIR
FINE POWDER DRYER VENT SCRUBBING AND RECOVERY
1984 .1988-89
CURRENT 1989
WATER
REPLACE C-8 WITH TBSA 100% in 1985 15% in 1987 30% in 1990
ELIMINATE SUPERNATE PONDS
- NEW ITEM 1H88
RJZQ26563
003546-32 - 06/03/87 - RJZ:kst
EiD091386
EID137083
WASHINGTON WORKS OFF PLANT EMISSIONS
WATER
POUNDS 0 8
1983
1986
21,700
19,100
AIR
12,700
16,200
PRODUCT
8,000
8,300
OFF-PLANT DISPOSAL
7,700
8,300
50,100
51,900
003546-10&11 - 06/03/87 - EJZskst
EID091387
EID137084
RJZ026564
C-8 LEVELS IN DRINKING WATER
DISTANCE FROM NO. 5
OUTFALL (miles)
C-8 LEVEL - PPB 1984 1987
PARKERSBURG 7.50 UPSTREAM
ND ND
WASH. WORKS 0.50 UPSTREAM
ND ND
LUBECK WATER DISTRICT
0.25 DOWNSTREAM 0.25 DOWNSTREAM
1.1 1.9 1.5 . 1.9
LITTLE HOCKING 3.00 DOWNSTREAM
RAVENSWOOD
29.0 DOWNSTREAM
0.6 ND
ND
;__
RJZ026565
ND = NOT DETECTABLE
003546-7 - 06/10/87 - RJZ:kst
EID091388
EID137085
FINE POWDER DRYER C-8 EMISSIONS REDUCTION
LABORATORY STUDIES
DEMONSTRATED ABILITY TO SCRUB TO 95% EFFICIENCY
CAN CONCENTRATE TO 5% USING ION EXCHANGE
CAN CONCENTRATE TO GREATER THAN 10% USING REVERSE OSMOSIS
DEMONSTRATED SUCCESSFUL POLYMERIZATION US ING RECOVERED VIRGIN C-8 FROM ION' EXCHANGE
RJZ026566
003546-24 - 05/19/87 - RJZ:kst
EID091389
EID137086
SURFACTANT RECOVERY ACTION ITEMS
START UP TEST C-8 SCRUBBER ON FINE POWDER DRYER EXHAUST - 3Q87
DEMONSTRATE FEASABILITY TO ECONOMICALLY CONCENTRATE AND REUSE C-8 AND OTHER SURFACTANT SOLUTIONS - 4Q87
COMMERCIAL RECOVERY AND RECYCLE OF C-8 IN FINE POWDER - AUTHORIZE $3MM IN 2Q88 - STARTUP- 2H89 -
APPLY ABOVE TECHNOLOGIES TO FEP IF ECONOMICAL
RJZ026567
003546-28 - 06/09/87 - RJZkst
HD09B90 EID137087
TBSA REPLACEMENT IN FEP
NO PANACEA
15% CONVERTED IN 1987 - 1.2 MM LBS. FEP
ADVANTAGES
- REDUCES SURFACTANT DISCHARGE TO OHIO
RIVER
LBS OF SURFACTANT TO RIVER
IN 1986
_______ (if 100% of type)________
C-8 17,500
TBSA
7,400
- CAN MAKE UNIQUE HIGH HFPI/LOW MV POLYMERS WITHOUT PENALTY
- DEMONSTRATED 20% HIGHER POLYMERIZING RATES
- $1 MM COMPANY COST SAVINGS POTENTIAL
003546-30 - 06/09/87 - EJZskst
E1D091391
RJZ026568
EID137088
TBSA REPLACEMENT IN FEP
DISADVANTAGES
- 30 - 40% RATE PENALTY IN HUMID HEAT TREATING - LOSS OF 1.5 - 2.0 MMAP CAPABILITY
- QUALITY PROBLEMS - COLOR AND GEL
- DISPERSION AND DRY FLAKE PRODUCTS REQUIRE FDA CLEARANCE
7 - EXPECT TBSA TO ACCUMULATE IN THE BLOOD
/
gj
~~i~~`7zy<3
.
1 S A ^ - y [Ovi/
I
o\ <o
^ i-S o t's' k >'k
^ o T r/I
4oj.,
` 003546-31 - 05/19/87 - RJZikst
I'
E1D091392
EID137089
RJZ026570
TBSA REPLACEMENT IN FEP
DISADVANTAGES
- 30 - 40% RATE PENALTY IN HUMID HEAT TREATING - LOSS OF 1.5 - 2.0 MMAP CAPABILITY
- QUALITY PROBLEMS - COLOR AND GEL
- DISPERSION AND DRY FLAKE PRODUCTS REQUIRE FDA CLEARANCE
- EXPECT TBSA TO ACCUMULATE IN THE BLOOD
<* i. . I* `
g
/'.r k `A
RJ2026570
003546-31 - 05/19/B7 - RJZikst
EID091392
EID137090
TBSA CONVERSION ACTION ITEMS
CONTINUE WITH TRANSITION AS BUSINESS OPPORTUNITIES EXIST - FORECAST OF 30% CONVERSION BY 1990
EXPAND HUMID HEAT TREATING CAPABILITY
SEEK FDA APPROVAL OF TBSA BASED RESINS
RJZ026571
003546-29 - 05/19/87 - RJZ:kst
EID091393
EID137091
SUPERNATE POND ELIMINATION
BENEFIT -
ELIMINATE C-8 CONTAMINATION OF LUBECK WATER SYSTEM AQUIFER FROM THESE PONDS
STATUS - PROJECT APPROVED ($320M) 11/86 - PERMIT APPROVAL 3Q87 - START-UP 11/87
RJZ026572
003546-33 - 06/10/87 - RJZ:kst
!
EID091394
EID137092
WORK ENVIRONMENT PROGRAMS (in place since 1981)
EQUIPMENT DESIGN EQUIPMENT SEALS AND GASKETS LEAK MAINTENANCE OVERALL BUILDING VENTILATION CONTROL VENTILATED HOODS OVER DRYER DOORS VENT STACK HEIGHT FOR PROPER DISPERSION INGREDIENT MAKEUP STATION
PROTECTIVE EQUIPMENT COMFO HALF MASK RESPIRATORS BREATHING AIR RESPIRATORS LATEX RUBBER GLOVES
MONITORING
'
AFFECTED PERSONNEL BLOOD LEVELS
PERSONAL AIR MONITORING
CRITICAL AREA AIR MONITORING
003546-14 - 05/19/87 - RJZskst
E1D091395
RJZ026573
EID137093
f
C-8 TRENDS IN AIR
C-8 IN AIR (MPB)
PERSONAL SAMPLES
AEL = 0.56 MPB
FEP POLYKETTLE OPERATOR
1980
--
1981 0.12
1982 0.09
1983 0.09
1984 0.19
1985 0.08
1986 1987 (YTD)
0.13 0.08
FEP WET FINISHING `
OPERATOR
0.95 o i o 0.09 0.11 0.09 0.17 0.12 0.08
RAW DISPERSION A/C OPERATOR ' 1.20 0.26 0.09 0.21 0.20 0.36 0.76 0.30
FINE POWDER DRYER OPERATOR
WS920ZTH
1.40 0.56
0.15
0.06 0.10
0.78
0.87
0.11
003546-3&4 - 06/09/87 - RJZskst
EID091396
C-8 TREND IN BLOOD
FEP PROCESS OPERATOR (17) FEP SERVICE OPERATOR (18) RAW DISPERSION
PROCESS OPERATOR (18) GRANULAR PROCESS
OPERATOR ( 7 ). FINE POWDER
SERVICE OPERATOR (19) MONOMER OPERATOR (31)
C-8 IN BLOOD (PPM) 1981 1982 1983 1984 1985 1986 1.53 1.48 1.14 1.09 1.09 1.22 0.60 0.59 0.57 0.53 0.53 0.56
7.66 6.67 6.36 6.38 5.96 6.57
3.44 3.12 2.64 2.70 2.38 2.93
2.25 1.01
2.07 1.02
1.74 0.83
1.59 0.82
1.37 0.81
1.37
am
ALL TEFLON* OPERATORS (490) 0.98 0.92 --
--
m
EID091397
* DuPont's registered trademark for its fluorocarbon resin
003546-5&6 - 06/09/87 - RJZkst
5S920Zni
FINE POWDER DRYING C-8 IN AIR HISTORY
1980 - 1981
- INITIAL CONTROL PROGRAM
1982 - 1985
- C-8 LEVELS BELOW 0.6 MPB
JUNE - DEC '85 - "FRESH AIR" TO DRYER SWITCHED FROM DRYER ROOM TO EXTERNAL
- INSTALLED NEW LARGE DRYER
- C-8 LEVELS ROSE TO 2.3 MPB
ACTION TO RESPOND
- INSTALLED VENTS ON FLOAT TANKS
- RELOCATED PACKOUT ROOM H&V INTAKE
- INSTALLED LARGER DRYER ROOM EXHAUST FAN
- PROVIDED FRESH AIR TO DRYER CONTROL ROOM
AUG '86
C-8 LEVELS FELL TO 0.9 MPB
ACTION ITEM
- REPLACED GASKETS ON NO. 3 DRYER
DEC '86 - TODAY - C-8 LEVELS FELL TO 0.2 MPB
003546-23 - 06/10/87 - RJZ:kat
EID091398
RJZQ26576
EID137096
ACTIVITY AT OTHER SITES
SITE DORDRECHT
ACTIVITY ~ Initial blood sampling - C-8 in air monitoring
MDF
-- No blood sampling -- C-8 in air monitoring
CHAMBERS WORKS - initial blood and air sampling - Not sampling today
2
N
s
3M
- Blood sampling for organic fluoride - Highest levels now below 10 ppm
SPRUANCE
~ Initial blood and air sampling - Not sampling today
OUTSIDE DuPONT
END USER (CHEMFAB)
- Notified of birth defect problem - Told to continue existing practices - No sampling
C&P
No blood sampling for- other telom er products including TBSA
003546-869 - 06/09/87 - RJZ:kst
EID091399
EID137097
ACTION ITEMS
ADMINISTRATIVE
ESTABLISH A MAXIMUM SAFE C-8 IN BLOOD CONCENTRATION
ESTABLISH A MAXIMUM SAFE C-8 IN DRINKING WATER LEVEL
USE AIR AND BLOOD MONITORING AT ALL DIRECT USER SITES FOR THOSE PERSONNEL AND AREAS WHERE EXPOSURE IS GREATEST - ESTABLISH A MINIMUM THRESHOLD LEVEL - PERIODIC SAMPLING TO MONITOR PERFORMANCE
REVIEW C-8 IN BLOOD DATA IN DETAIL TO DETERMINE IF ADDITIONAL CONTROL DEVICES ARE REQUIRED
MAINTENANCE
MAINTAIN PRIORITY ON SEALING OF NEW DRYER AT WASHINGTON WORKS
PROCESS
EXAMINE BENEFITS OF PURCHASE OF AQUEOUS SOLUTIONS OF C-8 VERSUS POWDER
CONTINUE TO EXAMINE NEW SURFACTANTS LIKE C-9, C-10 AND C-12 EID091400
003546-25 - 06/09/87 - RJZrkst
EID137098
RJZ026578
JS^oe^TOSBiSi^!
CONCLUSIONS
SIGNIFICANT ENVIRONMENTAL REDUCTIONS ARE EXPECTED BY 1989.
PRESENT CONTROL SYSTEMS HAVE REDUCED C-8 IN BLOOD CONCENTRATIONS FROM 1979 LEVELS. FURTHER REDUCTIONS ARE EXPECTED IN THE FUTURE.
ELIMINATION OF C-8 IN EMPLOYEES BLOOD APPEARS UNLIKELY.
RJZ026579
003546-34 - 06/04/87 - RJZ'.kat
EID091401
EID137099
KEY POINTS
Karrh agreed to work directly with his counterpart at 3M to get the 3M C-8 chronic study in rats released.
Karrh stated that we should consider reducing the pressure on the conversion of C-8 to TBSA in FEP. It was agreed that business needs should drive this program.
Karrh and Todd asked if there was a way to determine if there was an aquifier water flow from under the supernate ponds to the Lubeck Water System wells. R. J. Zipfel has lead on this.
Karrh asked if supernate shipment to Chambers Works was the long term solution for the disposal of supernate containing C-8. Zipfel answered yes, but there is a low probability chance on the development of a new strain of bacteria which could destroy the C-8 or recovery using the technology being developed for the fine powder dryer vent.
Karrh asked what is the significance of the high C-8 concentration in the blood of the raw dispersion operator.
It was stated that all people who have had their blood tested have had their C-8 levels reported to them.
Karrh requested that we get information on the accumulation of other fluorine containing surfactants in the blood of employees. Of specific note was TBSA in Chambers Works personnel.
Karrh asked why progress in our use of aqueous C-8 solution in lieu of powder has been so slow. Zipfel responded that liquid C-8 is presently on order by Chambers Works and Dordrecht.
Karrh stated that we need to continue to pursue those programs aimed at reducing the public exposure to C-8 as vigorously as we can. He further stated that he agreed that our people will continue to have measureable C-8 levels in blood.
The action items recommended by Zipfel were all agreed to.
PC#4-2 - 06/15/87 - RJZ:kst
EID091402
N
o K> ON Ch oo o
EID137100