Document LgZBZyX43rMJbdbeo95K0j05g

Monsanto CALL REPORT-ORGANIC DIVISION DICTATE IN SEQUENCE: 1. HEADING INFORMATION 2. NAMES OF ADDRESSEES 3. NAMES OF CARBONEES 4. IMMEDIATE ACTION NEEDED 5. REPORT ON CALL CUSTOMER' date of call COHMOHWEALTH EDISOH CO&PAHY CITY AND STATE Kavwood, Illinois ~ DATE RECEIVED 10/1/70 <5/25/70 DATE TYPED 10/1/70 CUSTOMER MAILING LIST CHANGES - SERVICE CENTER USE ONLY name and title PUT TAKE ON OFF MP mag: CATEGORY CODES REPORT CAPTIONS: 1. OBJECTIVE 2. PERSONS CONTACTED 3. RESULTS 4. ACTION REQUIRED REGION St. Louis SERVICE CENTER Chicago SALESMAN James J. Roder/saa TO J.R. FALLON - JFALL cc J.S. Pullman - Hew York Soger Irwin - Houston D.E. Roush - St. Louis Personnel Contacted: J.L. Williams - Transmission Engr. E.H. Grosser, Jr. A. Zanona Bob Hesse " n n n n n b RESULTS: I learned about this potential through a supplier of level gauges (Vico Assoclates). Commonwealth has been buying fluids to cool underground electrical cables enclosed in steel pipgT The use or nuids to cool tne cables allows them to use smaller cables to transmit electrical power. Apparently this has been done for many years but it appears that there is renewed interest ln_ expanding the idea. Years ago Sun #6 oil was used; now the standard fluid ' is polybutene normally supplied by Cosden or Standard Oil. Polybutene is made by polymerizing butene gas. The best estimate of the selling price for polybutene in bulk shipments is $0.30/gal. The typical cable system would be three cables laid in an 8" schedule 20 pipe. The cable Is wrapped in paper insulation and then wrapped with a cop per tape. After the pipe is laid it is filled with fluid. Each foot of pipe requires about 2 gallons of fluid. The fluid is cooled in a heat ex changer to about 68F and pumped at 200 gpm and 250 psi into the pipe. At the end of the pipeline the fluid is returned to the pumping station at about l4oF and 100 psi. Freon 22 is used for cooling. This cooling appli cation is also being studied to determine if an intermediate fluid would work better because the condensing Freon 22 causes angeling action of poly butene around the tribes in the heat exchanger which greatly reduces heat transfer rate. They will probably consider an Intermediate system of FR-LoTemp between the Freon 22 and polybutene. Properties of the present fluid they use are: Vi8C 100F 212F ., % 115-lkO SSU (24-30 cs) 3o-44 SSU (3*5-5.5 cs) Power Factor 0.1* at 212F Dielectric Strength 35 KF or higher (ASTM Des. 0877) -------- ----------------------------------------------------------------------------------------------------- ----------------DSW 201836 s-33i <kev. 12/68) 5 - DEVELOPMENT COPY -- STLCOPCB4059903