Document LgMk4kqB45v0KR0a7zNRvVM5
bcc M. A. Pierle p. S. Park
A. E. Leisy - 1740
'c. F. Buckley - 1740
June 14, 1976
Mr. Blake Biles Enforcement Division (EN-342) Environmental Protection Agency 401 M Street, S.H. Washington, D.C. 20460
Dear Mr. Biles:
This is in response to Mr. Stanley Legro's letter of May 29, 1976 concerning the EPA inspection report of our W. G. Krummrich plant.
We have examined the data enclosed with Mr. Legro's letter and find an error in the calculations used to determine the air losses from storage tank emissions. The vapor pressure of Aroclor 1242 is 0.35mm at 100C, not 3mm at 100C as used in the report. This means that the correct storage tank emissions should be 70.6 Kg/year, not 597.4 Kg/year. These corrections apply to pages number 509 and 548.
The other information present appears to be correct.
Sincerely,
cs cc S. W. Legro
J. Coleman Weber Manager Product Acceptability
unit of Monsanto Company
MONS 093355