Document LgGeRBBq7nRNKzV5KVjqXe7nb
CertainTeed Corporation P.O. Box 860 Valley Forge. PA 1W82 (215) 687-5000
Material Safety Data Sheet
js PLAINTIFF'S { ^ EXHIBIT
I JMMC-73
(For more information, contact Medical Department)
Section 1, Material Identification Chemical Name and Synonyms: Asbestos
Trade Name and Synonyms: Asbestos/Cement Pipe
Cnemtcai Family: Mineral
Formula: Hoc Applicable
This ?-!SDS applies to Asbestos contained in CertainTeed Corporation Asbestos/Cement Pipe products.
See also, MSDS for Silica contained in CertainTeed Corporation Asbestos/Cement Pipe products.
Section II. Ingredients and Hazards MIXTURE: Asbestos
*** fibers per cubic centimeter Silica (Crystalline)
* millions of particles per cubic foot of air
** milligrams per cubic meter
Section iii, Physical Data
Boiling Point ff.1 Vapor Pressure (mm Ng.) Vapor Oensity (Air * 1) Solubility in Water Appearance and Odor
Fiber, white or blue in color.
N/A N/A N/A N/A
No odor.
%
10-20% by weight
Hazard Data
8-hr TLV 2 fibers/cc*** Ceiling 10 fibers/cc, . ( >5 pm in length)
5% or less 8-hr TLV (Respir. Dust)
in finished 250 mppcf* or 10 mg/nv***
product
% Si02 + S
Si02 + 2
8-hr TLV (Total Dust) 30 mg/m^ % Si02 + 2
Specific Gravity (H'0 * 1)
Percent Volatile by Volume (%) Svaporauan nett
f -
"gm27s375cc N/A N/A
Section IV, Fire and Explosion Data______________________________ ______________________________________
Flash Point and MethodAutoignition Temp.Flammability Limits in Air
n/a * N/A
N/A
Extinguishing Media: Use that which is appropriate for surrounding fire. This material is non-combustible.
AUG. 1 9 1983
D 003331
Section V. Health Hazard Information TLV (See Section II)
Excessive inhalation of particulates can cause asbestosis, a disabling fibrosis of the lungs which gradually reduces lung capacity and efficiency.
Excessive inhalation can also cause Lung Cancer, and Mesothelioma, a cancer of linings around the lung or abdominal cavities.
Smoking greatly increases the risk of Lung Cancer and Mesothelioma.
Section VI. Reactivity Data This is a stable material<.*
Section VII, Spill. Leak and Disposal Procedures Steps to be taken in case material is released or spilled: Pipe fragments and installation debris must be handled,in a manner which avoids airborne dispersion of Asbestos dust. Use wet or vacuum method for cleanup. Avoid inhalation of dusts.
Waste disposal method: Dispose in accordance with Federal, State.and Local regulations
Section VIII, Special Protection Information
Respiratory Protection: Not required when recommended work practices are followed.
Ventilation: N/A
Special: N/A
Mechanical (General): N/A
Other: N/A
Protective Gloves: Not required
Eye Protection: Not required
Other Protective Clothing: Not required when recommended work practices are used.
Section IX. Special Precautions am* Comments Precautions to be taken in storage and handling: Always use industry-recommended work practices when handling or performing field operations. See manufacturer's install ation manual, American Water Works Association Manual M-16, or Asbestos/Cement Pipe Producers Association publications for detailed information on industry-recommended work practices.
Other precautions; Do not cut or bevel Asbestos/Cement Pipe on fittings with abrasive disc saws or abrasive disc sanders.