Document Lg82D1EkddJyBZG5x9Ea25e9b

Boiler (Water Treatment) Aquatic Chemical & Metallurgical Engineers 114 East 32nd Street Water Treatments for Correcting LAND WATER SERVICE New York, N. Y. Rust, Scale, Foaming and Related Water Troubles An Organization of Water Treatment Experts Announces Two New A. C. M. E. Developments to Eliminate Metal Deterioration in 1. STREET STEAM SYSTEMS Having successfully treated corrosion in marine and stationary high pressure boiler plants, A. C. M. E. undertook the cor rection of a serious problem of corrosion pcisting in the street steam heating system in one of.the largest buildings in the world. Nearly three years of intensified chemical and engineering research resulted in the perfection of a unique and wholly new A. C. M. E. Service. This consists of an exact proportioning 2. AIR CONDITIONING SYSTEMS The presence of a very large amount of air, with its many impurities, dissolved in the water used in air conditioning plants accelerates the corrosion many fold. This results in a very real and serious problem. A. C. M. E. Air Conditioning Treatment protects all parts which come in contact with water by using regulated amounts of proper chemicals. The percentages of each and the relation of one to another are maintained by our automatic feeding mechanism and chemicals (patent applied device. These Treatments are not poison for) which protect the entire heating system by reaching every point in accurate proportions. These A. C. M. E. Treat ments contain, no heat retarding in gredients. ous regardless of the amounts used and therefore can be handled and used safely. Red brown particles in water indicate corrosion. Our analysis will de termine accurate conditions. Bottles sent on request. (No charge). Results: 1. Eliminate corrosion and erosion in the entire heating system. Tests show 2'r,] c treat?rd meta>s last at least 8 to 10 times longer than untreated metals. See our Street Steam Reports. 2. Saves at least 7 per cent on steam by keeping traps clean. 3. saves electricity. Clean traps do not permit "blowing through" thus shortening vacuum pump operation. 4. Pays for itself in longer equipment life and smoother operation of system bv stopping costly renewal of pipe and reconstruction work. A. C. M. E. Treatments for Boiler Heating Systems 8 Instead of depending on a single preparation for all boilers and all troubles three specially prepared A. C. M E. products are now available. See picture below. formhof^min hnhWC' ^ B` er H,e.atmg Treatments is to mix with the steam in the form of small bubbles This has a washing effect on the entire system (air valves traps imo'hotTe he^rtTS 3nd aux.llianes); bringing all. loosened oil, rust and dirt particles back inHIhli 'hese Partlcles are kept in. a chemical and physical colloidal suspension ' until blown out, according to directions in our No. 1 L. P. Bulletin. A. C. M. E. ingredients do not settle out in the boiler, and cause clogging. RECOMMENDED AND USED BY LEADING HEATING AND VENTILATING ENGINEERS A Clean Heat ing System No Priming Fuel Savings Up to 25%' More Steam at Lower Boiler Pressures Quicker Steam Stops Rust and Prevents Cracking. WA. C. M. E. Users are Impressed by Positive Results 896 Boilers, Gas American Gas Products Corporation Division of American Radiator & Standard Sanitary Corporation 40 West 40th Street, New York, N. Y. Gas Boilers for Hot Water . . . Steam and Vapor Heating . . . Automatic Hot Water Storage Heaters . . . Air Conditioners . . . Gas Fired Steam Radiators Approved by A, G. A. Laboratory for Steam, Vapor or Hot Water Heating Systems. Ratings Below. Standard Ideal Empire Ideal Specifications for Standard Ideal and Empire Ideal Gas Boilers STEAM BOILERS WATER BOILERS Steam Boiler Number ACJL Steam Rating Sq. Ft. Supplies ' Sq. Ft. Direct C. I. Radiation No. and Size of Tappings Supply Return In. In. Water Boiler Number AG.A Water Rating Sq. Ft. Supplies Sq. Ft. Direct C; I. Radiation No. and Size of Tappings Supply Return In. In. OGS-4 0-GS-5 O-GS-6 0GS-7 0-GS-4-E OGS-5-E 0-GS-6-E 0-GS-7-E OCS-9-E 0-GS-11-E l-GS-4 l-GS-5 l-GS-6 l-GS-7 l-GS-8 l-GS-9 l-GS-10 l-CS-ll 4-GS-6 * 4-GS-7 4-GS-8 4-GS-9 4-OS-IO 4-GS-II 4-GS-I3 4-GS-J5 4-GS-17 4-GS-I9 4-CS-2I 4-GS-22 4-CS-25 4-GS-28 4-GS-3I 4-GS-33 4-GS-37 4-GS-41 - 270 360 450 540 255 340 425 510 680 850 610 775 940 1105 1270 1435 1600 1765 2000 2400 2800 3200 3600 4000 4800 5600 6400 7200 6000 8400 9600 10800 12000 12800 14400 16000 173 230 289 346 163 218 272 327 436 545 391 497 606 715 826 938 1050 1165 1332 1624 1922 2214 2505 2793 3387 4000' 4570 5143 5714 6000 6857 7714 8570 9145 10285 11430 2-21/. 2-V/i 2-2(5 2-2/2 1-3 1-3 1-3 2-3 2-3 2-3 2-4 2-4 2-4 2-4 2-4 2-4 2-4 2-4 2-6 2-6 2-6 2-6 2-6 . 2-6 4-6 4-6 4-6 4-6 4-6 6-6 6-6 6-6 6-6 8-6 8-6 8-6 I-IV, 1-1 (5 l-iy. 1-1`/2 l-l*/2 \-\< 1-1Vi 2-11/2 . 2-iy, 2-H/5 2-1 2-4 2-4 2-4 2-4 2-4 2-4 2-4 2-5 2-5 2-5 2-5 2-5 ' 2-5 3-5 3-5 3-5 3-5 3-5 4-5 4-5 . 4-5 4-5 5-5 5-5 5-5 l-GA-4 210 l-GA-5 280 l-GA-6 350 l-GA-7 420 2-GA-4 420 2-GA-5 560 2-GA-6 700 2-GA-7 ' 840 4-GA-9 1120 4-GA-l 1 1400 GA-13 1680 1-GW-4 980 l-GW-5 1240 l-GW-6 1500 l-GW-7 1770 l-CW-8 2030 1-CW.9 2300 1-GW-10 .2560. i-cw-n 2820 4-GW-6 3200 4-CW-7 3840 4-GW-8 4460 4-CW-9 5120 4-GW-I0 5760 4-GW-1I 6400 4-GW-13 7680 4-CW-15 8960 4-GW-I7 10240 4-GW-19 (1520 4-GW-21 12800 4<lW-22 13440 4-GW-25 15360 4-GW-28 17280 4-GW-3I - '"19200 4-GW-33 20480 4-GW-37 23040 4-GW-41 25600 135 180 225 270 270 359 449 539 725 ` 915 1109 631 807 980 1168 1353 1598 1739 1935 2214 2676 3151 3634 4114 4571 5486 6400 7314 8230 9143 9600 10970 12343 13714 14625 16457 18286 2-1/, 2-1/2 2-VA 2-l(( 2-lK 2-11/5 2-P/2 1-2(4 1-2'A I-2/2 21--221/24 2-11/2 1-2V2 1-214 1-2(5 1-21(5 2-214 2-24 2-21/7 2-2'A 2-4 2-2'A 2-4 2-4 2-4 2-4 2-4 2-4 2-4 2-4 ' 2-4 2-4 2-4 2-4 2-4 2-4 2-4 2-6 2-5 2-6 2-5 2-6 2-5 2-6 2-5 2-6 2-5 2-6 2-5 4-6 3-5 4-6 3-5 4-6 3-5 4-6 3^5 4-8 3-5 6-6 4-5 6-6 4-5 6-6 4-5 6-6 4-5 8-6 5-5 8-6 5-5 8-6 5-5 AU Boilers except type 4-G are available in either Standard Ideal or Empire Ideal models. 897