Document LYawbyk2ZR2Vy4dDyVyy9bKX

FILE NAME Corning OC DATE 1947 Dec 31 DOC OC051 DOCUMENT DESCRIPTION Internal Memo RE Dust Count of the Cement Insulation Operation oa a sn a FORM O.C 6.0 CORNING FIBERGLAS CORPORATION COMPANY CORRESPONDENCE Attention of F. Van Voorhis - Newark Newark Ohio December 31 1947 Subject DUST COUNT OF THE INSULATION CEMENT OPERATION OC A. L. Sinison C. . muckor ... Norriso Dr. Campbell File Attached is a memo written by . C. Kashner of the works Laboratory who made dust counts in our insulation cement department His findings reveal that t ere is a serious houlth hazard in this area particularly around the paoking buck und scales The writer requests that plant gineering gineering Department either install more adequate dust collecting hood or initiate request to General Minecring to design such equipment CJ plk W. C. Jones General Engineering Department 02 203 1275