Document LNryD6eM5GaqRboYm1dRX1oq
J-M Manufacturing Company, Inc.
To: W. G. Burnett, Stockton
From: W. R. Arant, Denison \
IPu)
Copies: T. E. Lohman
Subject: EMPLOYEES PHYSICAL EXAMINATIONS
Internal Correspondence
Date: March 8, 1984
Received Af/*ft 12 1984
I have reviewed the proposed physical examination guidelines for PVC personnel, asbestos exposed personnel, and office personnel.
_Section*1001 of the Federal Occupational Safety S Health Standards requires that all employees exposed to airborne concentrations of asbestos fibers be provided an annual comprehensive physical examination. This is in conflict with Mr. Ed Wang's recommended medical program for employees exposed to airborne asbestos fibers. . Mr. Wang's proposed guidelines only provide for a physical exam of the respiratory and gastrointestinal system every three years
for those workers under kO, with less than 10 years of exposure.
Another problem we are farced with-in Denison is that 95% of our
employees are exposed to airborne asbestos fibers at some time. It is very difficult, if not impossible, to determine who should get what type of physical. It is my recommendation that all employees at Denison receive the physical exam outlined in Table II, with the following changes:
Item #2 ~ Periodic exam - General physical exam to include an
exam of the respiratory and gastrointestinal system by a licensed physician - Annual
ADD
I tern #12 - Obtaining serum specimen to determine total bilirubin, alkaline,-phosphatase, SGOT, SGBT, and gamma gluatamyl - All pre employment, periodic as'- outlined in item #9 of Table 1, termination exam as outlined in item #9 of Table'!.
WRA/la
MAR. 1 3 1984
0 002405
J-M Manufacturing Company, Inc.
To: From:
W. G. Burnett, Stockton
\4 T. E. Lohman, Denison
CM
< i ICO':
--
Jwv J
Interna! Correspondence
Date: January 6, 198A
Copies: W. R. Arant, Plant Nurse
Subject: MEDICAL SURVELLIANCE PROGRAM
?
We recently received the results of the industrial hygiene survey that was conducted in late September and early October of 1983. According to the survey results, we have no areas in our plant that are equal to or above the current action level for VCM (0.5PPM). Based on these results, we will eliminate the SMAC 20 blood test from our physical exam program effective immediately. We are also
eliminating the EKG from our physical exam program. This was a requirement under the previous ownership, but not a requirement of the Occupational Safety and Health Act.
fie
We will continue to perform the following items as part of our medical surveillance program:
Chest X-ray Eye Examination Urinalysis Pulmonary Function Test Blood Pressure S Vital Signs
0dt:
rt*TEL/,a . variate" /s
//'<*?e'*>,*yi/CyM, /
'/iji
Hearing Test Medical History Exam by Licensed Physician Consultation of Findings
PL resJ
s*e rfe sa" _
r^U. Js
'f
P r&rT sfi*-
H7-
JAIL 1 71864
JAN. 1 B 1984
D 002406