Document LM4J0vn38qq3YwY6JXNYE9jq

J M. J. VAUDREUIL PITTSBURGH OFFICE PLAINTIFF'S EXHIBIT AL-205_____ TO MR. 6. D. HICKS HAS J Industrial Hygiene MASSENA OPERATIONS 1979 August 13 RE; INDUSTRIAL HYGIENE SURVEY OF MASSENA OPERATIONS < I. Summary and Discussion _______________ __ The following is a summation of the walkthrough survey conducted in conjunction with the OSHA industrial hygiene inspection of 1979 July 10-13 and 24-26. Recommendations are included for your information and for the consideration of production management. Observations made during the two week-long visit indicate that we have potentially serious health hazards at Massena. These conditions clearly deserve attention and remedial action. The problems which I will review should be given top priority. Management support of corrective efforts is essential. Many of the conditions observed can.be expected to result in OSHA citations. While the OSHA inspector's judgement and techniques may be open to criticism; nevertheless, the fact remains that we do have health hazards that should be controlled. A number of these problems have been recognized before, but corrective action is not apparent. Again, attention by Massena management is fundamental to resolving these situations. The problems noted can be grouped into several major categories, each with plant-wide implications. Specific recommendations are listed in Section II. The major areas for concern are: A. Maintenance ^yj '' There does not appear to be an aggressive,'; on-going maintenance program at Massena; particularly with respect to exhaust ventilation and housekeeping^ '. Lack of maintenance and effectiveness of exhaust systems was evident throughout the smelting plant. Areas^worthy of particular note were: /pitch unloading, butt:-stripping and bath crushing.^ -j " Housekeeping of the workplace an'd lunchrooms was poor, resulting in excessive dust levels on floors, eating surfaces, and in the plant atmosphere. Many sections of the potrooms and associated areas have as much as six inches of accumulated' dust on the floors. Vehicles passing through these areas were observed creating clouds of airborne dust.. Similarly, several floor sweeping machines put a greater amount of dust into the air than in their collection boxes.. - ___ ARCH 18577 A. I ssjuh&wjjj. -"juaijwwbsmt <JL , MR. G*. D. HICKS Page 2 1979 August 13 B. Work Practices Many practices were observed which unnecessarily Increase employee exposure to dust, noise, asbestos and coal tar pitch volatiles. The use of inappropriate tools, equipment and procedures is commonplace; 'and in several cases, standard operating procedure. For example, (transporting ore and bath in payloaderf causes much dust to become airborne. Routing siphon tubes without lqcal exhaust ventilation has much the same effect^ Training In general, employees have not been adequately informed about the health hazards of their respective jobs, nor about the precautions needed to be taken. This is at least partially responsible for improper work practices, as well as both inadequate and incorrect usage of personal protective equipment. .^For example, workers have not received formal instruction in /" the use and care of respirators. ^ Massena's industrial hygiene staff is both concerned and competent. However, the effectiveness of the industrial hygiene program is dependent upon the support and commitment of Massena management at all levels. Conditions at Massena suggest that we must reaffirm this commitment if we expect to make progress in controlling health hazards. The Pittsburgh Industrial Hygiene staff is ready to supply any needed assistance. II. Recommendations Recommendations are divided into two categories. The first concerns complex problems with plant-wide application. They generally call for organized efforts or programs, rather than for correction of specific conditions. The second category is devoted to the latter. Category I: Plant-Wide D - ei - $Oz_i-o<> ost pv A written, comprehensive respiratory protection program should be established and administered. iG^T^nUrumum, the program should include sections 1910.134 (b) (1) through 1910.134 (b) (14) of the OSHA standards as detailed in Alcoa's respiratory protection standard. . MjJ ^ EN b2 A written program for the routine evaluation of all exhaust ventilaMnn gy<!l'p"lg should he devised and implemented. The '6U assistance of tne tngineering Department may be necessary. The program should include measurements of face velocity and sot. static pressure, as well as comprehensive visual inspections. I ARCH 18578 .W-!J.W.IJJUULJUPJtJ!gf^ MR. G. D. HICKS Page 3 1979 August 13 "r dost fa ~\ 3.- Vacuua-fl Racing nethod^KouId replace sweeping where feasible. Sweeping is inefficient and causes unnecessary dispersion of \ ust (in some cases, toxic dusts) into the plant atmosphere. ' Lunchrooms and other designate?^ea^lng area? shoufsPbe cleaned 'I'fdquefttly to prevent accumulation of dust on eating surfaces The hazards of ingesting toxic materials would be substantial reduced. Eating areas should be air conditioned and maintained at a slight positive pressure so that doors and windows can be ke; closed. This-would greatly restrict the influx of dust. Heating of food containers in work areas should not be permitted Contamination by fluorides and other toxic materials is possible Microwave ovens could be provided in designated eating areas. Consideration should be given to providing cji_xafe_with "Catco" (or similar) ventilation systems for reduction of operator exposure to excessive levels of airborne contaminant and for thermal comfort. Excessive noise levels from high velocity air exhaust ports are common to all areas of the workFJ All such noise sources should be fitted with suitableTm- ufflers. Some examples are: a. conveyor transfer cylinders crane bucket cylinders c. pot siphon tubes --------d. jackhammer exhaust B-c: 'fr > (ij All non-essential uses of asbestos shhoo'uuld b6e eliminated and appropriate substitute maC,eriaT5-Qtilized. For those applications where asbestos cannot be replaced, its use must be rigidly controlled. A written program would be beneficial; encompassing all of the requirements listed in the OSHA asbestos standard, 1910.1001. Please refer to H. G. Sakoian's letter of July 30, regarding asbestos substitution. Category II: Specific Conditions err)/ The exhaust ventilation gygrpm Mprovided ^ln the pitch unloading - -b z-4.11352) is grossly inadequate Little of no vapor is collectedT.h_e__e__x_i_s_t_i_n_g_ c_u_r_t_a_i_n_s___s_hould be extended downward to xeach the top" of the car; effectively encrosing~tlie"source of emissions. Operation of the blowers must be checked. Personal and area sampling shouUTThen be performed to evaluate z. the effectiveness of the system. Additional details may be obtained from R. L. Guilloud's environmental audit of the carbon plant, dated 1978 June 26. 70 3 ARCH 18579 ..... . .......ti imtmr MR. C. D. HICKS Page 4 1979 August 13 O0>f $ CT& ' y / Sic'*'*" The missing length of flexible duct for the conveyor hood atoj 'rr%the H?*i fl"i^ r'M should be replaced. CTPV's are now emittef directly to the workroom air. OVS>T v All access doors, covers and panels on the pjytma2i>im]3gctyy^-V exlgug^^jg^ea--iBldg. 354B) must be kept closeotoensure / "T? JD eff icient operation and minimize employee exposure to dust DUST Every effort should be made to repair holes in the primary anc secondary--impactor--exhaust.ductwork as soon as they appear. Such deficiencies greatly reduce the effectiveness of the system. - " fJ Cr?c_ In Bldg. 354B, suitable mufflers should be installed on the hurt conveyor.transfer cvclinders to reduce employee exposure to noise levels-of-99"to"l`00~aBA generated by high velocity exhaust air. .fa ft 6. For maintenance work in the scrubberpppp houses iBldgs. 368A and 368B), where several ppm o^S02 piay be present, workers should wear full facepiece respirators with acid gas cartridges^ Scott Air Paks are too restricting for that type ot work. ~ 3 i *f- s- n/- * mj Lightweight, acid-resistant clothing should be furnished to employees required to perform maintenance work around the ^. \r'xr. scrubber systems in warm weather. Consideration should be given to constructing^Sn acoustical. enclosure about the anode blow-off station (Bldg. 351)!This ^'"would reduce employee exposure to the present^ intermittent noise levels of up to 100 dBA. ___ DUS T~ t-*C &w ( 6- 9. , The smelting plant locker room should be vagpumed r_a_t_h_e__r__t_h_a__n_ y >u (&L CIJ,?p1' - Sweeping serves to disperse fluoride-laden dust into 3 & f* i ,y ) }r ? > c/" h': TT ^107} $, < "rij n. .c . !P ,i \C( IVC5b Sinhon^tubes should not be cooled with compressed air prior to cleaning!__This practice exposes employees to noise levels of approximately 95 to 100 dBA, for periods up to one-half hour in duration. &UST Routing of sinhon--tubes, generates large quantities of airborne dust. The operation should be provided with local exhaust ventilation and/or isolated. ~ : " ~1 ^ ---------Hearing protection must be worn when routing out slpWn_tubS. The practice generated sound levels in excess of 95 dBA. In addition, consideration should be given to either changing and/or isolating the operation. 3- c a ARCH 18580 ........-- w/MBw-gw.'.wAv. - j --umoujuu... imm MR. G. D. HICKS Page 5 1979 August 13 U^n. yen $-c- All employees using jqgJskammers must wear hearing protection. Jackhammering (includfng crus t breaking) produces noise levels ranging from 105 to 115 dBA. fact 14. Lack of lubrication on the anode conveyor (north side of 318) u*Ay*'" V t reSafrea in noise leveTs^Ji yl tor"93 1<iba. Proper lubrication would reduce the noise to less than 85 dBA. ront-end loaders should not be used t1^8^^ofSff-oloaadd bath_frog^?he * 1" b^a^t=hs=A=ru=a=h=er=--=st=o=ra=g^e5t^a=nk:=s" ThiT"e5cKa'u'st ventilation .provided ;C/f *1" A .4/*^*^.s'ettect"ive only It or tne^fcoxes designed for this purpose . ..I . .... Consideration should be given to an enclosure 1$ acoustical <1 c 4 r"'- 17. C.'A(/' rv)f, 18. < ( / iy . (?' 19. (.f, ' treatment for the .bath,.crashing mill. The operator ot the mill is presently overexposed to noise levels of 94 to 102 dBA. jpost~ The capacity of the v-afh rrnciipr gt.orage-havs should be doubled. Thfs would acconmodafe"the_excess bath which presently is one source of a serious dust problem. *o Pu % t ? The exhaust ventilation system for the or^^ill^ng^statd^n in Bldg"374' must be repaired. The blower is inoperative; con sequently, large quantities of dust are generated during /5- C filling operations. JD U^T The practice of dumping ore and bath with a payloader into the hopper located in 378B should be discontinued. The-area is no.t-prnvide.d_vlth~local exhaust ventilation~ Dust from the "operation completely fills the area and drifts through the P-75 potrooms, creating an unnecessary exposure. ^q\A If f 4 V. 20. The present enclosure for the vibrator in k)nt t--he __qSndry is 'A /St I w ) inadequate. Noise levels outside the curtain are in the range . - < 6s tr AA *J' 95 to 102 dBA. A mo.re substantial structure is needed. $ A/7/[ ! 21. /Consideration should be given to separation of the various _ 6 It j | foundry j^glndin&--stations with acoustical curtains to reduced ^ vcgfry-over of noise. 3 22. 5 / c f c/J The coreTjoK>.ck-out station should be provided with .local / r< exchaus't ven^iatlon to minimize employee exposure to silica-beari<ig J du1ast. TTJ&tyt-AA )~ / IfAA . ARCH 18581 MR. G. D. HICKS Page 6 1979 August 13 {/0tf4ok& M. J. VAUDREUIL MJV:olf cc: T. B. Bonney, Pittsburgh Office - 7 B. D. DInman, Pittsburgh Office - 7 G. H. Schneider, Kassena Operations J. Reid Clark, Kassena Operations V. W. Rieke, Pittsburgh Office - 2 R. L. Guilloud, Pittsburgh Office - 2 V. T. Burt, Massena Operations R. K. Morrow, Massena Operations wJUUMUBAJU55 s Ml / i,ea-|G^^^-> FROM M. J. VAUDREUIL , MR. C. D. KICKS PITTSBURGH OFFICE MASSENA OPERATIOHS a*4A*&i -#u /UibJi . I ^butiwivtfl aOi> Vwt.i P<..vJ-^nyw 1979 Auj 7y- ** /6. 4w< /u^AudUj+iiJjLn Uitk^^Uw mi'./iiiinfMl - . . RE: INDUSTRIAL HYGIENE SURVEY OF MASSEKA OPERATIOHS .yy I. Summary and Discussloo The following is a summation of the walkthrough survey conducted in conjunction with the OSHA industrial hygiene inspection of 1979 July 10-13 and 24-26. Recommendations are included for your information and for the consideration of production management. Observations made during the two week-long visit indicate that we have potentially serious health hazards at Masscna. These conditions clearly deserve attention and remedial action. The problems which I will review should'be given top priority. Management support of corrective efforts is essential. Many of the conditions observed can be expected to result in OSHA citations. .While the OSHA inspector's judgement and techniques cay be open to criticism; nevertheless, the fact remains that we do have health hazards that should be controlled. A number of these problems have been recognized before, but corrective action is not apparent. Again, attention by Masscna management is fundamental to resolving these situations. The problems noted can be grouped into several major categories, each with plant-wide implications. Specific recommendations are listed in Section II. The major areas for concern are: A. Maintenance There does not appear to be an aggressive, on-going maintenance prroogitirlaantiaotnMaansdserh.oa;uspekaeretipcinugl.arly with respect to exhaust 1 Lack of maintenance and effectiveness of exhaust systems was evident throughout the smelting plant. Areas worthy of tr*ii i*** W'*' particular note were: bath crushing. pitch unloading, butt stripping and nr Housekeeping of the workplace and lunchrooms was poor, resulting in excessive dust levels on floors, eating surfaces, and in the plant atmosphere. Many sections of the potrooms and associated areas liave as much as six inches of accumulated dust on the floors. Vehicles passing through these areas were observed creacing clouds of airborne dust. Similarly, several floor sweeping machines put a greater amount of dust into the air than in their collection boxes. >*~r Jr** 0l<. ___ ^\LL_ Hi/--V J~ltiy Ju c e cf t sf9^' ** U f (a. 11 b c -fj ta-r-u </-/./ __ ________ ............................................ ' _________ ag=~ -----------------................................................................................................................................................................................... 'T-l : . : _#< A 1 .: < t rfy i*/ ~dv *j ARCH 18583 zua......j, jl.uu j tuwjt . w ' *De-r|cb/^r--^ FROM M. J. VAUDREUIL * PITTSBURGH OFFICE 64&M) -,&U /ucbJl f lit h^kVu>M<n.t 7r~$%-/L. '}-<\++n i HR. G. D. HICKS MASSENA OPERATIONS . *Lcr 4*j2W 1979 August 13 1*53Xr.t4.^t*4jm-) .. 7^t M t /MU A/t* ^A4L * *rU^nV~N ** RE; INDU-S--T--R--I-A-L H--Y--G--I-E-N--E----S-U--R--V-E--Y---O--F--M--A--S-S--E-N--A---O--P-E--R--A-TII0ONNSSv t^r / I. Summary and Discussion The following is a summation of the walkthrough survey conducted in conjunction with the OSHA industrial hygiene inspection of 1979 July 10-13 and 24-26. Recommendations are included for your information and for the consideration of production management. Observations made during the two week-long visit indicate that we have potentially serious health hazards at Massena. These conditions clearly deserve attention and remedial action. The problems which I will review should be given top priority. Management support of corrective efforts is essential. Many of the conditions observed can be expected to result in OSHA * citations. While the OSHA inspector's judgement and techniques may he open to criticism; nevertheless, the fact remains that we do have health hazards that should be controlled. A number of these problems have been recognized before, but corrective action is not apparent. Again, attention by Massena management is fundamental to resolving these situations. The problems noted can be grouped into several major categories, each with plant-wide implications. Specific recommendations are listed in Section II. The major areas for concern are: Maintenance ,vl^- ^TVTe There does not appear to be an aggressive, on-going maintenance program at Massena; particularly with respect to exhaust ventilation and housekeeping. Lack of maintenance and effectiveness of exhaust systems was evident throughout the smelting plant. Areas worthy of particular note were: pitch unloading, butt stripping and bath crushing. Yyy V Housekeeping of the workplace and lunchrooms was poor, resulting" in excessive dust levels on floors, eating surfaces, and in ' the plant atmosphere. Many sections of the potrooms and ARCH 18584 associated areas have as much as six inches of accumulated ________ dust on the floors. Vehicles passing through these areas were .observed creating clouds of...airborne dust. Similarly, .several * -floor sweeping machines put a greater amount of dust into the" - \X'r:~~ " air than in their collection boxes. !-*-&+*** .oK. '* * * -------------- ---- __________ H&S .^..ctrial Hygiene G. D. Hick't Thi* mmo tf<N( 4a aud to tSO matrtc tUAdtrd 66 12$ mn i 17$ mm. To: rr> </< <r "BOB tb8 ^ mu- *sCD CCD RMJ db ~~----------------------------27 -I f 41 ^ ty A f 6 4 IV I. ?! % <n i'trf f/lc/ t'n J.tf- CA<l//c's iAr /C /v*i /*- 0t*.lT Vi f */ S* *n/y> ai //<'Vi 'Hcs Y6Vt-fl'K# ef j/fioiY h H6 /#/W: * DW^/H- "D<v v* ,ff ptejuf/ tm-CleQcrjgrtfc flCpc pu^e/j . , , '7{IMS'- A tne fc A ne ide r Pritmvy PuJutrfs -j ^ J i tV\ Pu. * nf l " "n>7y Mfr. ^fc^*7 -- /?ir^\ Ynorfovv fatr. D;,f. ' 7 </ / Pr'.p.Jtl tf -> Dr, ty\Au.rtrc P/d<,rt medic*, f 'bcrec/tr/ J)m JncAsm, f**e(4<ny * Pv*/fv />^. topr a ALCOA *7 '/d< C/f Aluminum Company of America Maaaona Operation* P. O. Box 150 Maaaona, Naw York 13662 ..fuu V1 M-.1- JJ. --T?* fflCH 18586 jUfilWJPF HE. G*. D. HICKS Page 2 1979 August 13 Work Practices Many practices were observed which unnecessarily increase employee exposure to dust, noise, asbestos and coal tar pitch volatiles. y\iff ** * . The use of inappropriate tools, equipment and procedures Is commonpalsa*cae*; Aanndd 4inn cspevvperdral l rcflacspecs., ssttaannddaarrdd noopeerar.atitnin2g nprorocceecdure. For example, transporting ore and bath in pavloaders causes__ much dust to `become airborne^Routing siphon tubes without local exhaust ventilation has much the same effect. Training In general, employees have not been adequately informed about the health hazards of their respective jobs, nor about the precautions needed to be taken. This is at least partially responsible for improper work practices, as well as both inadequate and incorrect usage of personal protective equipment. For example, workers lave not received formal instruction in the use and care of respirators. th /r"> ux vaua4 Lu Massena's industrial hygiene'staff is both concerned and competent. However, the effectiveness of the industrial hygiene program is dependent - upon the support and commitment ot Massena management at all levels. ,, ^ **'**/ Conditions at Massena suggest that we n\ust reaffirm this commitment if we expect to make progress in controlling health hazards. The Pittsburgh L&f ** is & tb Industrial Hygiene staff Is ready to supply any needed assistance. /Jrxnci*** II. Recommendations Recommendations are divided into two categories. The first concerns complex problems with plant-wide application.' They generally call for organized efforts or programs, rather than for correction of specific conditions. The second category is devoted-to the latter. * V V-*'-.V.-i ..^,1'. - ' Category I; Plant-Wide ' vV>. A written, comprehensive respiratory protection program should be established and administered. As a minimum, the program should include sections 1910.134(b)(1) through 1910.134(b)(14) of the OSHA standards as detailed in Alcoa's respiratory protection standard. T> A written program for the routine evaluation of all exhaust ventilation systems should be devised and implemented. The assistance of the Engineering Department may be necessary. The program should include measurements of -face velocity and static pressure, as well os comprehensive visual inspections. .................. ' ' >*.' -` ^ (1 ARCH 18586 MR. G. D. HICKS Page 3 1979 August 13 Vacuum cleaning methods should replace sweeping where feasible. Sweeping is inefficient and causes unnecessary dispersion of dust (in some cases, toxic dusts) into the plant atmosphere. Lunchrooms and other designated eating areas should be cleaned frequently to prevent accumulation of dust on eating surfaces. The hazards of ingesting toxic materials would be substantially reduced. Eating ar.eas should be air conditioned and maintained at a slight positive pressure so that doors and windows csanu be knecppit. . . . closed.- This would greatly restrict the influx of dust. <..rZifi/f j PJJ- s&ssp6. Heating of food containers in work areas should not be permitted Contamination by fluorides and other toxic materials is possible. Microwave ovens could be provided in designated eating areas. Consideration should be given to providing crane cabs with "Catco" (or similar) ventilation systems for reduction of operator exposure to excessive levels of airborne contaminants and for thermal comfort. AJd",liu} h-t BCL tr*** 4jnJ***t**w . 7. Excessive noise levels from high velocity air exhaust ports are common to all areas of the works. All such noise sources should be fitted with suitable mufflers. Some examples are: a. conveyor transfer cylinders ) .. b. crane bucket cylinders (td**** c. pot siphon tubes d. jackhammer exhaust fy....il-ini Jp v j I t) tb - 8. All non-essential uses of asbestos should be eliminated and appropriate substitute materials utilized^For those applications .1 where asbestos cannot be replaced, its use must be rigidly J\controlled. A written program would be beneficial; encompassing all of the requirements listed in the OSHA asbestos standard, 1910.1001. Please refer to H. G. Sakoian's letter of July 30, regarding asbestos substitution^ /1^ ETSa #4^ Category II: Specific Conditions The exhaust'ventilation system provided in the pitch unloading "building ($352) is grossly inadequate.Little or no vapor is collected. The existing curtains should be extended downward to reach the top of the car: effectively enclosing the source of emissions^ Operation ot theblowers must be checked. Personal and area sampling should then be performed to evaluate the effectiveness of the system. Additional details may be obtained from R. L. Cuilloud's environmental audit of the carbon plant, dated 1978 June 26. - !^WraS55SeS3BS555S?35WSW555ef i ARCH 18587 HR. G. D. HICKS Page 4 1979 August 13 H~' 2 The missing length of flexible duct for the conveyor hood atop the P225. green mill should be replaced. CTPV's are now emitted directly to the workroom air. y'- All access doors, covers and panels on the primary impactor exhaust system (Bldg. 354B) must be kept closed to ensure efficient operation and minimize employee, exposure to dust. y Every effort should be made to repair holes in the primary and secondary impactor exhaust ductwork as soon as they appear. Such deficiencies greatly reduce the effectiveness of the system. ' 5. In Bldg. 354B, suitable mufflers should be installed on the butt conveyor transfer cyclinders to reduce employee exposure to noise levels of 99 to 100 dBA generated by high velocity exhaust air. t/.r. For maintenance work in the scrubber pump houses (Bldgs. 368A and 368B), where several ppm of SO2 may be present, workers should, wear full facepiece respirators with acid eas cartridees. Scott Air Paks are too restricting for that type of work. 7. Lightweight, acid-resistant clothing should be furnished to employees required to perform maintenance work around the scrubber systems in warm weather. ^ Consideration should be given to constructing an acoustical enclosure about the anode blow-off station (Bldg. 351). This would reduce employee exposure to the present, intermittent noise levels of up to 100 dBA. . 9. The smelting plant locker room should be vacuumed rather than swept.. Sweeping serves to disperse fluoride-laden dust into the air and onto employees' clothing. - 10. Siphon tubes should not be cooled with compressed air prior to cleaning. This practice exposes employees to noise levels of approximately 95 to 100 dBA, for periods up to one-half hour in duration. - 11. Routing of siphon tubes generates large quantities of airborne duSt. The operation should be provided with local exhaust ventilation and/or isolated.^^ruiuJ . (jVtJU/ 12. Hearing protection must be worn when routing out siphon tubes. The practice generated sound levels in excess of 95 dBA. In addition, consideration should be given to cither changing and/or isolating the operation. * . 1 D ^& 00 ABCHA8588 ri i rmtjjim V ' HR. G.. D. HICKS , Page 5 1979 August 13 All employees using jackhammers,must wear hearing protection. Jackhammering (including crustbreaking) produces noise levels ranging from 105 to 115 dBA. Lack of lubrication on the anode conveyor (north side of 318) resulted in noise levels of 91 to 93 dBA. Proper lubrication would reduce the noise to less than 85 dBA. Hi Front-end loaders should not be used to off-load bath from the bath crusher storage tanks. The exhaust ventilation provided is effective only for the boxes designed for this purpose. .16 Consideration should be given to an enclosure or acoustical treatment for the.bath crushing mill. The operator of the mill is presently overexposed to noise levels of 94 to 102 dBA. The capacity of the bath crusher storage bays should be doubled. This would accommodate the excess bath which presently is one source of a serious dust problem. 18. >6-3^ The exhaust ventilation system for the ore filling station in Bldg. 374 must be repaired. The blower is inoperative; consequently, large quantities of dust are generated during filling operations. The practice of dumping ore and bath with a payloader into the hopper located in 378B should be discontinued. The area is not provided with local exhaust ventilation. Dust from the operation completely fills the area and drifts through the P-75 potrooms, creating an unnecessary exposure. 20. The present enclosure for the vibrator in the foundry is inadequate. Noise levels outside the curtain are in the range of 95 to 102 dBA. A more substantial structure is needed. (UjJLb*.j . 21. Consideration should be given to separation of the various L foundry grinding stations with acoustical curtains to reduce carry-over of noise. y . 22i 0 The core knock-out station should be provided with local exhaust ventilation to minimize employee exposure to silica-bearing dust. { ARCH 16589 7T. MR. G. D. HICKS Page 6 1979 August 13 J M. J. VAUDREUIL MJVjmlf cc: E. E. Rumberger, Pittsburgh Office T. B. Bonney, Pittsburgh Office - 7 B. D. Dinman, Pittsburgh Office - 7 G. H. Schneider, Kassena Operations J.'Reld Clark, 'Massena Operations . ' V. W. Rieke, Pittsburgh Office - 2 R. L. Guilloud, Pittsburgh Office - 2 V. T. Burt, Massena Operations R. K. Morrow, Massena Operations