Document LKvLxMyyM7Jkz3Q0edb38d8d3
Air Conditioning
Unit Heaters and Coolers
The Unit Heater and Cooler Division
D. J. Murray Mfg. Go.
Wausau, Wisconsin
Offices in Principal Cities MANUFACTURERS OF THE GRID UNIT
(patented)
All-cast aluminum "fins" bonded to cost high-test iron
core.
No soldered. brazed, or expand ed joints -- no unions--no seams --fewest connec
tions Possible.
Typical Installation of Grid Unit Heater
GRID UNIT HEATER DATA
Model No.
Dimensions Inches
A B c D*
Face Area
Sq Ft
Motor . Hp Rpm
Vol. at Fan
Capacities 5 Lb Steam 60 Air
Btu Final Temp,
Approx. Shipping Weight
Pipe Sizes Supply Return
1000 16'/. h>/ 9% 16 0.84 1/20 1700
578 29,400 107
100
i%"
i%"
1200 l8'/2 13'/ 11% 17% 1.04
1/20
1700
711 46,000 119
120
i%"
i%"
5*5 23% 17'/ 11% 20 1500 23% 17% 11% 20
1.65 1.67
l/W
i/to
1750 1750
1290 1450
59,600 77,500
102 109
160 . 210
1 %" i%"
1 /." i%"
1520 27% 17% 11% 20
2.2
I/I0
1750
1700 104,000
113
250
i%" i%"
520 28% 22% 11% 21% 2.9
1/6
1150
2500 102,300
97
250
2"
i%"
2000 28% 22% "% 21% 2.9
1/6
1150
2500 148,000
114
320
2"
1%"
2025 33% 22% 11% 21% 3.6
1/6
1150
2875 177,000
115
370
2"
i%"
525 35% IP/l 13 28
4.5
1/2
1150
4200 166,400
94
390
2
i%"
2504 351/, 27% 13 28
4.5
1/9
1150
3200 210,000
118
420
2"
i%"
2500 35% 27% 13 28
4.5
1/2
1150
4200 225,000
108
440
2"
i%"
2530 371% 271/2 13 28
5.3
1/2
1150
4650 282,000
115
530
2"
!%"
530 39% 32% 13 29
6.5
1/2
1150
5300 260.500
105
600
2%"
I%"
3000 39% 32% 13 29
6.5
1/2
850 6350 341,000 109
690
2%"
1%"
3000 39% 32% 13 29
6.5
1%
1150
8100 394,000
104
725
2%"
l%"
Varies with type of motor:
GRID UNIT HEATERS ARE NOT AFFECTED BY ELECTROLYTIC ACTION
No leaks--no breakdowns. Low maintenance expense. More air changes per hour. Positive "directed" heat.
Lower outlet temperatures. Larger air volume. Reduced fuel cost. Applicable to either low or high steam pressure lines.
Send for Bulletin on Units not listed above.
852
Air Conditioning
Unit Heaters and Coolers
The Herman Nelson Corporation
General Offices and Factories at Moline, Illinois.
Sales and Service Offices in the Following Cities:
Portland. Maine Boston. Mass.
Westfield. Mass. New York. N. Y. Watervliet. N. Y. Syracuse. N. Y. Buffalo. N. Y. Philadelphia. Pa.
Harrisburg. Pa. Pittsburgh. Pa.
Johnstown. Pa.
Detroit. Mich.
Saginaw, Mick. Grand Rapids. Mich. Cleveland, Ohio Cincinnati, Ohio
Toledo, Ohio Washington. D. C.
Baltimore. Md. Richmond, Va.
Roanoke. Va. Charlotte, N. C.
Miami. Fla. Birmingham, Ala.
Nashville. Tenn.
Omaha. Nebr.
Memphis. Tenn.
Oklahoma City. Okla.
Indianapolis. Ind. Tulsa. Okla.
Chicago. III.
Dallas, Texas
Milwaukee. VVis.
Mtssoula, Mont.
Moline. III.
Denver. Colo.
Peoria. III.
Salt Lake City. Utah
Des Moines. Iowa Spokane, Wash.
St. Louis. Mo.
Seattle, Wash.
Kansas City. Mo.
Portland, Ore.
Emporia. Kans.
Los Angeles. Calif.
Minneapolis. Minn. San Francisco. Calif.
The complete line of quality heating, ventilating and air conditioning products manufactured by The Herman Nelson Corporation, makes possible the specifica tion of HERMAN NELSON for industrial, commercial and public buildings of all types.
Industrial areas may be efficiently heated with Herman Nelson hijet Heaters. The complete line of Horizontal Shaft or Vertical Shaft Propeller-Fan hijets or the Blower-Fan Type hijets provides a wide range of application and heating capacities.
Vertical Shaft Propel ler-Fan Type hijet Heater discharges air vertically downward, or available to discharge at an angle to vertical in various directions.
Commercial buildings, too, are well adapted to the application of hijet Heaters. The DeLuxe hijet, as well as the PropellerFan Types, provide a handsome exterior, heating efficiency and quiet operation. For winter and/or summer air conditioning, the Year Around Air Conditioning Unit
may be specified.
Public Buildings may be most satis factorily provided with proper heating and ventilating with the Herman Nelson Air Conditioner For Schools. This equipment maintains desired room air conditions at all times, prevents overheating, eliminates drafts, and is particularly applicable to areas where large groups of people gather. Ventilation of toilets and laboratories may be accomplished with the Herman Nelson Exhauster.
Engineering Data applying to Herman Nelson Products may be obtained from our sales representatives or The Herman Nel son Corporation, Moline, Illinois.
Blower-Fan Type hiJcl Healer provides efficient heating of large areas. With by-pass damper if desired. For floor,
wall, ceiling or in verted wall mounting.
DeLuxe hijet Heater (at left) pro vides unusually large heating cover age. For floor, wall or ceiling mount
ing.
Air Conditioner for Schools (right) available for damp er or radiator control in classroom or auditorium types.
853
Horizontal Shaft Propeller-Fan Type hiJet Healer (with adjustable louvers) projects air down ward in desired direc tion. Also available with attractive grille.