Document LKrY01G4ryGv8jdYnjgpk2p5q
<>
EFFECT OF PCB PHASE OUT
FINANCIAL
HEAT TRANSFER
N
Loss of $1.3M per annum sales
Q>Loss of $0.8M per annum gross profit
Disposal PCB fluid $1.0M (estimated)
CUSTOMER REACTION
- 685 customers using PCB heat transfer fluids - 62 of these customers major companies
and customers for other Monsanto products
EXAMPLES
GOODYEAR: Monsanto 1971 sales est. $21M Uses PCB1s in 150,000 gallon system in Applegrove, West Virginia--polyester plant. Reaction to immediate cut off will be violent and could have significant effect on tire cord and rubber chemical sales.
Recommend we allow Goodyearf 3 months to changeover
BURLINGTON INDUSTRIES: Monsanto 1971 sales est. $25M Has three systems: Altavista, Virginia; Cheraw, S.C.; Greensboro, N.C. All systems used to heat ovens for fabric finishing. Immediate cut off will interrupt production and result in violent reaction. Could result in reduced sales.
Recommend we alio1 2 mbnths changeover.
DSW 338581
k oux -(to
STLCOPCB4082336
GENERAL MOTORS: Monsanto 1971 sales est. $12M Has six systems--uses include heating of plastic extruders and heating asphalt lines for battery production. Immediate cut off would interrupt production and result in strong reaction. Recommend we allow 2 months changeover. FIRESTONE: Monsanto 1971 sales est. $27M Has three systems including press heating for tank treads and auto parts. Immediate cut off will result in violent reaction and will probably affect rubber chemical sales and textiles. Recommend we allow 2 months changeover. LEVER BROTHERS: Monsanto 1971 sales est. $30M Three systems used in soap manufacture. Proposal already made to convert to non-PCB fluid--favorable reaction but no action to date. Immediate cut off will result in very strong reaction. Sales could be affected. Recommend we allow 2 months changeover.
RECOMMENDATION IN ALL CASES WHERE PCB HEAT TRANSFER SYSTEM IS PART OF PRODUCTION OPERATIONS WE SHOULD ALLOW A CHANGEOVER PERIOD TO AVOID SHUTDOWNS AND INTERRUPTION OF PRODUCTION.
DSW 338582
STLCOPCB4082337
2) SALE OF PCB FLUIDS FOR TRANSFORMER OR CAPACITOR USE WILL BE DEPENDENT UPON THE RECEIPT FROM CUSTOMERS OF DOCUMENTS ACCEPTABLE TO MONSANTO, HOLDING MONSANTO HARMLESS FROM LEGAL LIABILITY ASSOCIATED WITH THE USE OF PCB'S IN TRANSFORMERS AND CAPACITORS. AS A SERVICE TO SUCH CUSTOMERS MONSANTO WILL AGREE TO ACCEPT THE RETURN OF USED OR SURPLUS PCB FOR REUSE OR DESTRUCTION ACCORDING TO ITS USUAL FEE SCHEDULE.
1) Law Department drafting proposed "hold harmless" document acceptable to Monsanto.
2) H. S. Bergen/J. Mason to visit Westinghouse and General Electric at Vice President level for discussions on Monsanto requirements, indicating contents of probable "hold harmless" document.
3) Follow up visits will be made with Monsanto Law Department to finalize agreement.
4) Visit smaller customers with "hold harmless" letter and attempt to obtain agreement without Law Department visits.
5) General Electric is a $9 Million customer of Monsanto; Westinghouse is a $4 Million customer of Monsanto. Negotiations will require verycareful handling.
DSW 338583
STLCOPCB4082338
EFFECTS OF THIS APPROACH ACCEPTANCE WILL RESULT IN:
1972 SALES
$ 8.7M
GROSS PROFIT $ 3.1M*
* Termination of polychlorinated terphenyl business will result in a $2.1M increase in manufacturing costs for Dielectric Aroclors; the gross profit figure quoted assumes we are successful in obtaining MSfcllpiiefo' pound price increase.
NON-ACCEPTANCE WILL RESULT IN:
1) Complete loss of all Dielectric sales
2) Complete loss of Biphenyl, HB-40, and associated product sales
$ 8.7M
_ $ 6.0M
TOTAL
3) Loss of gross profit from (1) & (2)
4) Total write-off of all Biphenyl-
Liquid & Solid Aroclor facilities
U.S .A. & U.K.
GROSS
NET. .
$ 14.7M
CUSTOMER REACTION
Major customers:
WESTINGHOUSE (Monsanto sales 1971 $4M est.), and GENERAL ELECTRIC (Monsanto sales 1971 $ 9M est.) will require careful handling and will resist strongly when asked to sign "hold harmless".
Smaller customers:
Will claim they are unable to sign and claim that G.E. and Westinghouse will have an unfair advantage.
DSW 338584
STLCOPCB4082339
3) IMMEDIATELY IMPLEMENT A PLAN TO TERMINATE ALL SALES OF POLYCHLORINATED TERPHENYLS; 75% OF SUCH SALES WILL BE TERMINATED BY MARCH 31, 1972. THE REMAINDER WILL BE TERMINATED NO LATER THAN JUNE 30, 1972.
A) PLASTICIZERS Advise all customers by letter December 1, 1971, that we are phasing out of polychlorinated terphenyls and that no sales will be made after March 31, 1972. Orders for material for the period December 1, 1971, through March 31, 1972, must not exceed l/3rd of the total quantity purchased during the preceeding 12month period. Many polychlorinated terphenyl customers are major customers for other plasticizers and will need careful handling by Marketing.
HYDRAULIC FLUIDS Advise customers individually that we are removing polychlorinated terphenyls from Pydraul formulations by June 30, 1972. 2) As rapidly as possible supply all refill and topup orders with Phosphate/Oil blends (timing dependent on NC Phosphate Esty. availability-- project anticipates need for jaffiPPPply) . 3) Assist customers in changeover and keep the lowest possible profile to avoid further undesirable publicity.
DSW 338585
STLCOPCB4082340
EFFECT OF POLYCHLORINATED TERPHENYL PHASE OUT
FINANCIAL
PLASTICIZERS
Loss of Loss of
sales gross profit
HYDRAULIC FLUIDS
Loss of $ Loss of $
sales gross profit
Subject to an orderly phase out we should regain 60% of this business with phosphate ester/oil replacement products, resulting in:
1973 sales 1973 gross profit
$3.0M $ 1.0M
CUSTOMER REACTION
PLASTICIZERS - Emotional, but with adequate turnover time should be able to hold other plasticizer business.
HYDRAULIC FLUIDS - Emotional, changeover time is vital--otherwise we will be unable to retain business.
EXAMPLES
Texas Eastern Gas Transmission Co. uses Turbinol 153 in 18 gas turbines, supplying major part of East Coast natural gas needs. Turbines were run in on Turbinol 153 and have used product for 14 years. Immediate withdrawal of product would be disastrous and could expose Monsanto to significant law suit.
Major steel companies such as Armco, Inland, Republic use Pydraul 150 in continuous casting plants (5,000-20,000 gallon systems). Change to alternate fluids will take 3-6 months. Immediate withdrawal could idle facilities with investments of $50-$100M.
DSW 338586
STLCOPCB4082341