Document LKqxQOrLN7vX1B92D5BB3o6x3
T. V. Kidd August 29, 1967
Chambers Works Process K-13-A78 531 etc. "Freon" Area
AEBOSOL SOLUTIONS "FBEQN" 12/VINYL CHLORIDE
Principle
These blends 'are prepared by direct mixing of "Freon" 12 dichlorodifluoromethane and vinyl chloride. The vapor pres sure of the solution can be obtained from Figure 1. (Vapor pres sure calculations were based on Raoult's Law.) They are used as aerosol propellants.
Reaction
None. This product is a physical mixture.
Critical Hazards
Blends containing more than 25% vinyl chloride are flammable when completely vaporized. Vinyl chloride is a dan gerous fire and explosion hazard. Take precautions to avoid sparks, open flames, or heated surfaces. Ground both storage container and receiver to protect- agaInst static electricity. Do not permit vinyl chloride or blends of "Freon" and vinyl chloride to contact copper or copper-bearing alloys, as a trace impurity of acetylene may form the explosive acetylide. These liquids can cause frostbite on contact with skin. Liquid-full systems must be avoided.
Bas is
Previous experience in making these blends. For ex ample, see TMR-C-64-79 (65% "Freon" 12/35% vinyl chloride), TMB-C-66-95 (76/24), TMR-C-66-103 (20/80) and the corresponding Test Conclusions.
Test Authorization TA-C-67-218, "All Existing 'Freon' Blends - Blending of 'Freon' Mixtures using the Foxboro Fluoro carbon Blending System", dated Marsh 7> 1967-
Eaufoment
Regular trailer and/or cylinder' loading facilities in the Service Building and Tank Farm, "Freon" Area.
TLS ' MOT
;V;
EID10553
T. V. Kidd
August 24, 1967
Chambers Works Process K-13-A78 531 etc.
Bill of Materials
Net basis (given per 100 pounds of product). May be scaled to fit any size .of approved cylinder. The loading density as per cent of water capacity is shown in Figure 2. (Calculated as described in CWPD Beport No. 156. Practice has been to recom mend ^ "per cent of water capacity 2.0$ under the calculated value shown in Figure 2.)
TIaterial and Orchem wt. Product Code Number Ratio
Lb./lQQ lb. Produced
Mol. Wt.
Orchem Spec. No
"Freon" 12 384 100
See Order
Wt. Batio x 101 120.9
27-F
Vinyl Chloride 985 960
See Order
Wt. Ratio x 101
62.5
Note 1
Product
Aerosol Solution "Freon" 12/Vinyl Chloride
99.0
100.00
Note 2
Note 1: Purchase from Dow Chemical Company
Note 2: Specifications for this product are as follows:
1. The product shall be a clear, colorless liquefied gas, substantially free from particulate matter.
2. The composition shall be as stated +1.0% by wt. "Freon" 12 and as stated +1.0% by wt. vinyl chloride.
3. The moisture content shall not exceed 25 ppm by weight for blends containing up to 40% by wt. vinyl chloride, and 40 ppm by weight for blends.con taining between 40 and 80% by wt. vinyl chloride.
4. The soluble residue shall not exceed 0.01% by volume.
EID10554
5. Halides shall be nil by the silver nitrate test.
Mote'- "Freon" 12/yinyl chloride blends containing over 80% by wt. vinyl chloride are not expected.
T. V. Kidd
August 24, 1967
Batch Size and Yield
-3
Chambers Works Process
K-I3-A.78 531 etc.
Batch size may be any value which may be contained in
any approved container. Standard and goal yield is 99%, repre
senting handling losses only. Yield will vary from 92 to 99^
depending upon the container.
Procedure
Scale as required to container capacity. Select be tween Alternative A and B.
Alternative A
1. Clean and inspect the container thoroughly, then evacuate it (unless loading on heels).
The container must be clean (unless loading-on heels); all oil, residue, moisture, etc. should be removed as completely as possible.
2. Calculate the weight to be charged, using the loading density data attached (Figure 2) and assuming 99% yield.
3. Charge accurately: (recommended order of addition)
(1) Caluclated amount of vinyl chloride. (2) Calculated amount of "Freon" 12.
Check the weight of each component by actual scale weight or
by Neptune Meter, whichever is available. Container must be less than 95% full.
Note:
When loading vinyl chloride, ground both the stor age container and receiver to protect against static electricity. It is desirable to load the vinyl chloride out-of-doors to minimize the fire hazard,,
EID10555
4. Mix-'the contents of the container- thoroughly.
This may be accomplished by rolling the cylinder.
5. Bequest the "Freon" Control Laboratory to sample the container , and conduct the following analyses:
T. V. Kidd
August 24, 1967
-4 -
Chambers Works Process
K-13-A78 531 etc.
Analysis______
______ Orchem Method No.
Appearance Composition
Moisture
Soluble Residue Halides
6-50-3
6-30-1 (gas chromatography)
2-14-5 (Karl Fischer)
6-50-3
6-6-6
ATTternative B
X. Evacuate the tank (unles-s loading on heels). Connect auto matic blender to the tank truck and/or tank car and attach ground wire.
2. Calculate total pounds to be blended, using the available data on tank car or tank truck volume and the attached load ing density data, and set batch size selector.
3. Dial in the per cent of each component on the respective selector dials.
4. Start blender and permit system to operate until automatic shut-of f.
5. Check liquid level in tank truck by rotogauge and tank car weight by scale weight.
This check is to avoid overfilling. Tank dust be less than 95/ full.
6. Bequest the "Freon" Control Laboratory to sample the container and analyze as indicated above (Alternative A, Step 5).
EID10556
Labeling
All blends of "Freon" 12/vinyl chloride will have a vapor pressure exceeding 25 psig at 70F and therefore will be considered a compressed gas in accordance, with ICC regulations.
"Freon" 12/vinyl chloride blends containing more than 25%
by weight vinyl chloride will be considered flammable and will be labeled such as per ICC regulations.
Small containers of this mixture are color coded with one 1 l/2" red tape on a white cylinder.
T. V.- Kidd
August 24, 1967
"5 -
Chambers Works Process
K-I3-A78 531 etc.
Chemical Hazards
Starting Material
Product
Flammability
"Freon" 12 Nonflammable
V inyl Chloride
"Freon" 12/ Vinyl Chloride
Flammable
Flammable If > 25%
vinyl chloride
Toxicity
TLV 1000 ppm
TLV 500 ppm MAC 500 ppm
Irritant
None
Avoid skin contact and inhalation.
Avoid skin contact and inhalation.
Beactivity
Avoid flame heat
Avoid copper,; Avoid copper, cop
copper-bear per-bearing alloys,
ing alloys, sparks, flames and
sparks,
heated surfaces.
flames and
heated sur
faces.
Waste Disposal
"Freon" 12
Vinyl Chloride
Physical state Odor Volume
Vapor Faintly ethereal
About 1%
Patent Status
Vapor Natural gas
About 1%
In the opinion of Orchem-Patent Service, we are free
to operate this process. Opinion is based on OPA-63Q7, K, C. Ackerman, May 14, 1963.
E1D10557
.sav
August 24. 197
K-13-A78 531 etc