Document LKYkmnm69VkBKRMjnO9kpmOp5

3m RECEIVED JUN 22 1978 GENERAL OFFICES 3M CENTER* SAINT PAUL, MINNESOTA 55101 TEL. (612) 733-1110 January 12, 1978 Dr. Jerry Lautner Dept. Industrial Engineering TAMU College Station, Texas 77843 Dear Dr. Lautner: The attached data compilation is presented for your use. / The data is considered proprietary and confidential and as such must not be copied or redistributed without the knowledge and agreement of the Occupational Health and Safety Products Division of 3M Company. / !/l } r $ Any request for ether than the above use shonlri ho dirrrtTd ,ij T t--~ T^ih writing to the 3M Company"! This letter is necessary so u that the proprietary information developed is not released V / to comPetitive manufacturers. ^ Sincerely, f W i,A) / ' \0 /I) fi). ' ii Einar D. Horne Technical Director 3M Company, 3M Center Occupational Health and Safety Products Division Building 230-B St. Paul, Minnesota 55101 EDH/hv Attachment h TA9V 6/ miNNESOTA IT] I N IN G AND m A N U F A C T U R I N G C 0 m P A N Y s;w 3m 3NK BR4ND SPR/IY MINT RESPIR4TOR #8711 3M Brand Spray Paint Respirator *8711 provides proper protection against paint spray particulate and vapors. Protec- that is mandatory, especially with today's fast cure coatings. *8711 is unique with a combination of features that add up to dependable protection, comfort and economy. It's a combination that both employer and spray painter can appreciate. MAINTENANCE-FREE ECONOMY Designed for limited use periods, the *8711 is disposable and priced to make replacement economical. A spray painter simply discards it when used to capacity. Reduces cost and time of con ventional respiratory maintenance programs. Eliminates costly in ventory of extra cartridges, filters and spare parts. WIDE FIELD OF VISION Low profile half-mask design offers a wider field of vision than dual cartridge respirators. Painters can safely see where they are going and what they are painting. Glasses, safety goggles ond faceshields can be worn easily. DEPENDABLE PROTECTION Independent studies have shown that when used in accordance with the "Use and Fitting Instructions", the *8711 performed as well as if not better than conventional NIOSH/MESA ap proved dual cartridge spray paint respirators. UNIQUE THREE PART CONSTRUCTION Not a "mask", this respirator has a built-in filter of activated carbon between the molded interliner and exterior shell. This three part combination provides both efficiency and protection. SECURE FIT Wide headbands can be readily adjusted for individual com fort and protection. Sawtoothed buckles prevent headband slip page from extensive head movement. *8711 fits a wide range of facia! shapes and sizes. EFFECTIVE COMFORTABLE SEALING Soft plastic sealing ring provides secure but comfortable facial fit. Flexible nosepiece with extra foam cushion also as sures an excellent seal against vapor and particulate penetration around the respirator. LIGHTUVEIGHT *8711 is a lightweight 2 ounce respirator designed for worker com fort and productivity. It's the lightest spray paint respirator available. Dual cartridge respirators weigh approximately 12 ounces. BACKED BY 3M EXPERIENCE *8711 is one of the latest in an established series of disposable respirator "firsts". For more than a decade. 3M has been develop ing and manufacturing innovative industrial respirators, SAL 000Oo69:1.8 #8711 RESPIRATOR FITTING INSTRUCTIONS Place respirator under -- * chin wtti nosepiece up. Cup respirator in hand with nosepiece ol finger tips allowing straps to hang freely below hand. Pull top band over head and position at top back of head Pull bottom band over head and position around neck below ears Using both hands, mold metal nosepiece to shape of nose. Position the facepiece on the face and tighten each head harness; a. grasp buckle with left hand and pull out from hair. b. pull forward on the loose elastic with the right hand The tension in the head hcmess may be de creased without removing Ihe respirator from the head. To loosen a head harness: a. grasp the elaslic in front of the buckle with the left hand. P. grasp Ihe buckle in right hand and push out on flat surface. The seal of Ihe facepiece on the face must be tested prior to wearing the resoirator for protection in a contaminated ctmcsphere. a. Cover the fronl of respirator with both hands, being careful not to disturb the position of the facepiece, b. Exhale sharply, a positive pressure should be felt inside the facepiece. If air leakage is detected, adjust the position of the facepiece on fhe face and/or adjust the tension in the elostic strapping of the head harness loops. Retest the seat of the facepiece to the face. Repeat this procedure until the facepiece is seated properly to the face. TOXIC SUBSTANCE WARNING The need for proper respiratory protection during painting is extremely important because the iso cyanate vapors used with acrylic enamels and polyurethanes can cause lung irritation and al lergic respiratory reactions. In some cases, con tinued exposure will lead to severe reactions, Studies and laboratory tests have shown the #8711 respirator is effective in removing isocyanate vapors generated during painting. The 3M Brand #8711 respirator protects against vapor and paint particulates from: Enamels, Lacquers, Epoxies, Acrylic Enamels. Polyurethanes. CAUTION When the #8711 respirator is used as protection against isocyanate hardeners, it must be dis posed of after five days of use.e.g., Monday thru Friday, regardless of length of total spray time. -NIOSH/MESA APPROVAL STATUS The 3M Brand Spray Paint Respirator #8711 is not approved by NIOSH/MESA at this time because the respirator does not meet the design criteria specified in 30 CFR Part 11. Changes in 30 CFR Part 11 are pending that will allow this spray paint respirator to be approved. We have on file data to prove the #8711 respirator operates as well as if not better than a NIOSH/MESA approved sprciy paint respirator. OSHA ACCEPTANCE* Information outlining the technical adequacy of the No. 87VI Respirator for use against isocyanate containing paints can be provided to our cus tomers upon written request, as necessary in accordance with the U.S. Department of Labor, Occupational Safety and Health Administration Field Directive #300-9 dated June 9.1977, para graph G.I.g on page 18. ATTENTION INDUSTRIAL HYGIENISTS An industrial Hygienist should determine the suitability of this product for any intended use. Selection and recommendation for usage of the respirator must be made after the proper assessment of the working environment. This will require a thorough knowledge of all processes, related equipment, raw materials, products and applications which can create an exposure hazard, THE FOLLOWING WARRANTY IS MADE IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED. INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PURPOSE: 3M OH&SP products sold will meet the physical standards and properties set forth in the applicable product specification data sheets issued by 3M. 3M`s only obligation under this warranty shall be to replace such quantity of 3M Safety Products proved to be defectively monufaclured by tailing to meet the aforementioned specification data sheets, and lo be responsible for any third party personal injuries directly caused by said defects. Except as provided above. 3M shall nol be liable or responsible for any loss, damage, or liability, direct, indirect, incidental, special or consequential, arising out of the sale, use or misuse of, or the inability to use products by the user. ANOTHER STEP TOWARDS BETTER OCCUPATIONAL HEALTH AND SAFETY a Occupational Health L Safety Products Division 31 COtfiPMTf 3 M CENTER SAINT PAUL. MINNESOTA 55101 . Q D tWb Dk.la |