Document LKYRVejornDdemxKze6ZzgY2q
Certairileed 4s
Date December 18, 1980
Subject INDUSTRIAL HYGIENE SURVEY "B" PLANT NOVEMBER 12-14, 1980
To Location and mail code
Jack Anderson
Hillsboro 257
Q/P*55
Location and mail code
Janis Woodson'--"/?
VF Corp #4
cc: F. Timpe - 2125/2B J. McGinley - 2125/2B D. Hall - 2125/2B
B Blakeslee - 1126/00 N Pocock - Hillsboro 257 0 Kittilstad - 1125/4
Attached find a completed log of the personal/area air samples and audiodosimetry results. These samples were obtained November 12-14 during the new B-Plant start up, with some follow-up air sampling and noise work done in A-Plant.
A total of 52 air samples were obtained with 44 being in B-Plant and 8 in A-Plant. One 20 minute sample (#171) taken on a Maintenance person was heavily loaded with particulate and an exact count was not possible, however, in order to determine an exposure level an attempt was made to count the sample. The results were found to be in excess of 61 f/cc. Insufficient data was obtained, therefore a TWA was not calculated for this employee. This sample was found to be above the current OSHA ceiling concentration of 10 f/cc.
Sample number 150 taken on the Mixer Operator for 60 minutes was found to be 4.6 f/cc. This employees time weighted average (TWA) was 1.1 f/cc. The current OSHA 8 hour time weighted average (TWA) is 2.0 f/cc.
Both of these samples (#150/171) were taken on employees involved in clean-up and repairing a block up at the Bag Opener flat conveyor. The Maintenance person (sample #171) was in the pit uhclogging raw fiber and putting it in plastic bags while the Mixer Operator (sample #150) was on the upper level emptying the bags back into the bag opener. All employees in the area wore 3M-8710 air purifying respirators.
While the current OSHA Asbestos Standard 1910.1001 d2(i) of the Federal Register (attached) requires only air purifying respirators for levels from 10-100 f/cc short term exposures, it is our recommendation that when a block up of this type occurs or when an exposure of this level is expected or unknown the employees involved should be outfitted with powered air purifying respirators or supplied air respirators (continuous flow or pressure demand).
All other samples taken during this survey were within the OSHA standard with only 2 other samples being above 1.0 f/cc (samples #153/#169). They were taken on the Mixer Operator (#153) and the Crusher Operator (#169). Both wore 3M^8710 respirators. It is recommended that any area/job position that exceeds 1.0 f/cc should be reviewed for possible engineering changes and monitored regularly for all sizes and classes of pipe to insure that the employees exposure remains below the 2.0 f/cc level. If a level of 2.0 f/cc or greater is found, respirators are required until an acceptable level is again achieved.
a-ia-oooa
CTD020687
Hillsboro A/C Plant Industrial Hygiene Survey November 12-14, 1980
Also, more testing is needed at the Mandrel Handler job position. Of the 5 samples taken at this position during this survey, 4 were voided due to heavy particulate concentration. It is recommended that plant personnel sample this job position for personal and area exposures for an 8 hour shift, limiting each sample to no more than 60 minutes each.
The results of the audiodosimetry noise survey indicated 3 job positions with a daily dose percentage above 100% (90 dBA dosimetry). The current OSHA standard limits the daily noise dose to 100% with a 90 dBA dosimeter.
Those positions exceeding the 100% are:
Mandrel Handler (Sample 197) Relief Person (Sample 198) Crusher Operator (Sample 199)
185% 111% 193%
It is recommended that hearing protection be required for these job positions until proper and permanent noise controls can be instituted.
One thing to keep in mind when reviewing all of the sampling results from this survey, is that these samples were taken during a shakedown period and that these levels are not necessarily the same levels that would be found during normal operations. Continued surveillance and follow-up work of the new B-Plant by plant personnel, along with help from Corporate Health and Safety should be made. All equipment and operation changes and improvements should be noted when documenting the new exposure levels.
A complete and comprehensive survey report combining the May 27-30, 1980 survey and the November 12-14, 1980 survey is forthcoming detailing sample analysis and observations.
If you have any questions or comments don't hesitate to contact me.
JLW/tmf
CTD020688
'lsboro A/C Plant iustrial Hygiene Survey November 12 - 14 1980
No. 80 142
143
POSITION/ LOCATION (Date)
11 Boring Kill Operator (11/14/80)
NAME/AREA J. Slovk
144
#1 F M Lathe
A. Coaster
Operator
(11/14/80)
145
146 #1 F M Lathe T. Brown Helper (11/14/80)
'
148 Large Coupling J. Foster Saw and
Rework Saw Operator (11/14/80)
149
Table JJT
Personal Dust Exposures "A" Plant
ANALYSIS FOR
TIME
MIN.
Fiber
7:50a 11:45a
235
Fiber Fiber Fiber
11:45a 3:00p
195
7.55a 10:00a
125
10:00a 3:05p
305
8:20a 10:00a
100
10:00a 3:10p
310
8:00a l:35p
335
l:3Sp 3:05p
90
RESULTS F/CC
TVA REMARKS FOR SAMPLI
PERIOD
0.29
Boring 6" cplgs
0.27
0.24
0.10 0.078
0.084
6" 1/4 length FM'e
0.11 0.16
0.15
6" 1/4 length FM'e
VOID 0.55
1/4 hour Coupling Saw 3 1/4 hrs. putting rings In couplings 11/2 hrs Rework Saw Void sample heavy
particulate
6" Rework
CTD020689
Hillsboro A/C Pipe Plant Industrial Hygiene Survey November 12 - 14 1980
TABLE Personal Dust Exposures MBN Plant
No. POSITION/
NAME/AREA
80 LOCATION
(Date)
Manufacturing Department
150 Mixer Operator 11/13/80
R. Lacy
151
152
153
154
t 55 Machine Tender J. Owens 11/13/80
156
157
158 Control Operator 11/13/80
159
H. Cox
160
161 Mandrel Handler 11/13/80
162
C. Salinas
163
ANALYSIS FOR
TIME
MIN.
Fiber
8:05a 9:05a
60
9:05a 9:35a
30
Fiber Fiber Fiber
9:35a 11:20a
105
ll:20a 1:40p
140
l:40p 3:50p
130
8:15a 11:01a
166
11:01a 1:4 5p
164
1:45p 3:55p
130
8:07a 11:00a
173
11:00a l:42p
162
1:42p 3:50p
128
8:10a 11:01a
11:01a 1:46p
171 165
1:46p 3:55p
129
RESULT F/CC
TWA REMARKS FOR SAMPLE
PERIOD
4.6 0.26 0.36
S"150 pipe Helping unblock bucket elevator_at Bag pener_ __
Bag opener not working with 1002 efficiency having to slit Bags by hand One window to Bag opener open all the tine i.i
1.0 0.46
Employee wore a 3M 6710
Respirator throughout the entire shift.
0.21
6"150 pipe
0.17
0.20
0.23
0.025 0.027
0.026
6"150 pipe vlsable mist at press section
0.026
0.11
6"150 pipe
VOID VOID
-- Void sample - heavy particulate
Steamy area feel mist In air
Void sample - heavy particulate
CTD020690
Hillsboro A/C Pipe Plant "''duetrial Hygiene Survey
ember 12 - 14 1960
TABLE Personal Dust Exposures "B" Plant
No. 80 164
165
POSITION/ LOCATION (Date)
Take off Person 11/13/80
NAME/AREA J. Payne
ANALYSIS FOR
TIME
MIN.
Fiber
10:35a 1:35a
180
l:35p 5:00p
205
RESULT
REMARKS
F/CC
TWA
0.022 0.022
0.022
6"150 pipe Trayloader
166 Belief Person 11/13/80
167
Si. Pavelka
Miscellaneous Departments
168 Crusher Operator 11/13/80
C. Harris
'
170
Fiber
10:26a 1:52p
206
l:52p 5:00p
188
Fiber
8:45a 10:36a
111
10:36a 12:00N
l:30p 2:50p
84 80
0.13 0.15
0.14
6*150 pipe
0.36 1.7 0.37
0.78
Secondary Crusher Block-up 8:45a - 9:30a
Employee wore a 3M 8710 Respirator throughout entire shift
171 Maintenance Person 11/13/80
M. Ruda
Fiber
8:42a 9:02a
20
>61*
Working on a mixing system Block-up at flat conveyor for the Bag opener. All employees In the area wore 3M 8710 Respirators
172
9:02a
53
0.32
9:55a
* Note - filter heavily loaded with particulate actual count would be greater than 60f/cc
at water treatment slurry tank.
CTD020691