Document LKYRVejornDdemxKze6ZzgY2q

Certairileed 4s Date December 18, 1980 Subject INDUSTRIAL HYGIENE SURVEY "B" PLANT NOVEMBER 12-14, 1980 To Location and mail code Jack Anderson Hillsboro 257 Q/P*55 Location and mail code Janis Woodson'--"/? VF Corp #4 cc: F. Timpe - 2125/2B J. McGinley - 2125/2B D. Hall - 2125/2B B Blakeslee - 1126/00 N Pocock - Hillsboro 257 0 Kittilstad - 1125/4 Attached find a completed log of the personal/area air samples and audiodosimetry results. These samples were obtained November 12-14 during the new B-Plant start up, with some follow-up air sampling and noise work done in A-Plant. A total of 52 air samples were obtained with 44 being in B-Plant and 8 in A-Plant. One 20 minute sample (#171) taken on a Maintenance person was heavily loaded with particulate and an exact count was not possible, however, in order to determine an exposure level an attempt was made to count the sample. The results were found to be in excess of 61 f/cc. Insufficient data was obtained, therefore a TWA was not calculated for this employee. This sample was found to be above the current OSHA ceiling concentration of 10 f/cc. Sample number 150 taken on the Mixer Operator for 60 minutes was found to be 4.6 f/cc. This employees time weighted average (TWA) was 1.1 f/cc. The current OSHA 8 hour time weighted average (TWA) is 2.0 f/cc. Both of these samples (#150/171) were taken on employees involved in clean-up and repairing a block up at the Bag Opener flat conveyor. The Maintenance person (sample #171) was in the pit uhclogging raw fiber and putting it in plastic bags while the Mixer Operator (sample #150) was on the upper level emptying the bags back into the bag opener. All employees in the area wore 3M-8710 air purifying respirators. While the current OSHA Asbestos Standard 1910.1001 d2(i) of the Federal Register (attached) requires only air purifying respirators for levels from 10-100 f/cc short term exposures, it is our recommendation that when a block up of this type occurs or when an exposure of this level is expected or unknown the employees involved should be outfitted with powered air purifying respirators or supplied air respirators (continuous flow or pressure demand). All other samples taken during this survey were within the OSHA standard with only 2 other samples being above 1.0 f/cc (samples #153/#169). They were taken on the Mixer Operator (#153) and the Crusher Operator (#169). Both wore 3M^8710 respirators. It is recommended that any area/job position that exceeds 1.0 f/cc should be reviewed for possible engineering changes and monitored regularly for all sizes and classes of pipe to insure that the employees exposure remains below the 2.0 f/cc level. If a level of 2.0 f/cc or greater is found, respirators are required until an acceptable level is again achieved. a-ia-oooa CTD020687 Hillsboro A/C Plant Industrial Hygiene Survey November 12-14, 1980 Also, more testing is needed at the Mandrel Handler job position. Of the 5 samples taken at this position during this survey, 4 were voided due to heavy particulate concentration. It is recommended that plant personnel sample this job position for personal and area exposures for an 8 hour shift, limiting each sample to no more than 60 minutes each. The results of the audiodosimetry noise survey indicated 3 job positions with a daily dose percentage above 100% (90 dBA dosimetry). The current OSHA standard limits the daily noise dose to 100% with a 90 dBA dosimeter. Those positions exceeding the 100% are: Mandrel Handler (Sample 197) Relief Person (Sample 198) Crusher Operator (Sample 199) 185% 111% 193% It is recommended that hearing protection be required for these job positions until proper and permanent noise controls can be instituted. One thing to keep in mind when reviewing all of the sampling results from this survey, is that these samples were taken during a shakedown period and that these levels are not necessarily the same levels that would be found during normal operations. Continued surveillance and follow-up work of the new B-Plant by plant personnel, along with help from Corporate Health and Safety should be made. All equipment and operation changes and improvements should be noted when documenting the new exposure levels. A complete and comprehensive survey report combining the May 27-30, 1980 survey and the November 12-14, 1980 survey is forthcoming detailing sample analysis and observations. If you have any questions or comments don't hesitate to contact me. JLW/tmf CTD020688 'lsboro A/C Plant iustrial Hygiene Survey November 12 - 14 1980 No. 80 142 143 POSITION/ LOCATION (Date) 11 Boring Kill Operator (11/14/80) NAME/AREA J. Slovk 144 #1 F M Lathe A. Coaster Operator (11/14/80) 145 146 #1 F M Lathe T. Brown Helper (11/14/80) ' 148 Large Coupling J. Foster Saw and Rework Saw Operator (11/14/80) 149 Table JJT Personal Dust Exposures "A" Plant ANALYSIS FOR TIME MIN. Fiber 7:50a 11:45a 235 Fiber Fiber Fiber 11:45a 3:00p 195 7.55a 10:00a 125 10:00a 3:05p 305 8:20a 10:00a 100 10:00a 3:10p 310 8:00a l:35p 335 l:3Sp 3:05p 90 RESULTS F/CC TVA REMARKS FOR SAMPLI PERIOD 0.29 Boring 6" cplgs 0.27 0.24 0.10 0.078 0.084 6" 1/4 length FM'e 0.11 0.16 0.15 6" 1/4 length FM'e VOID 0.55 1/4 hour Coupling Saw 3 1/4 hrs. putting rings In couplings 11/2 hrs Rework Saw Void sample heavy particulate 6" Rework CTD020689 Hillsboro A/C Pipe Plant Industrial Hygiene Survey November 12 - 14 1980 TABLE Personal Dust Exposures MBN Plant No. POSITION/ NAME/AREA 80 LOCATION (Date) Manufacturing Department 150 Mixer Operator 11/13/80 R. Lacy 151 152 153 154 t 55 Machine Tender J. Owens 11/13/80 156 157 158 Control Operator 11/13/80 159 H. Cox 160 161 Mandrel Handler 11/13/80 162 C. Salinas 163 ANALYSIS FOR TIME MIN. Fiber 8:05a 9:05a 60 9:05a 9:35a 30 Fiber Fiber Fiber 9:35a 11:20a 105 ll:20a 1:40p 140 l:40p 3:50p 130 8:15a 11:01a 166 11:01a 1:4 5p 164 1:45p 3:55p 130 8:07a 11:00a 173 11:00a l:42p 162 1:42p 3:50p 128 8:10a 11:01a 11:01a 1:46p 171 165 1:46p 3:55p 129 RESULT F/CC TWA REMARKS FOR SAMPLE PERIOD 4.6 0.26 0.36 S"150 pipe Helping unblock bucket elevator_at Bag pener_ __ Bag opener not working with 1002 efficiency having to slit Bags by hand One window to Bag opener open all the tine i.i 1.0 0.46 Employee wore a 3M 6710 Respirator throughout the entire shift. 0.21 6"150 pipe 0.17 0.20 0.23 0.025 0.027 0.026 6"150 pipe vlsable mist at press section 0.026 0.11 6"150 pipe VOID VOID -- Void sample - heavy particulate Steamy area feel mist In air Void sample - heavy particulate CTD020690 Hillsboro A/C Pipe Plant "''duetrial Hygiene Survey ember 12 - 14 1960 TABLE Personal Dust Exposures "B" Plant No. 80 164 165 POSITION/ LOCATION (Date) Take off Person 11/13/80 NAME/AREA J. Payne ANALYSIS FOR TIME MIN. Fiber 10:35a 1:35a 180 l:35p 5:00p 205 RESULT REMARKS F/CC TWA 0.022 0.022 0.022 6"150 pipe Trayloader 166 Belief Person 11/13/80 167 Si. Pavelka Miscellaneous Departments 168 Crusher Operator 11/13/80 C. Harris ' 170 Fiber 10:26a 1:52p 206 l:52p 5:00p 188 Fiber 8:45a 10:36a 111 10:36a 12:00N l:30p 2:50p 84 80 0.13 0.15 0.14 6*150 pipe 0.36 1.7 0.37 0.78 Secondary Crusher Block-up 8:45a - 9:30a Employee wore a 3M 8710 Respirator throughout entire shift 171 Maintenance Person 11/13/80 M. Ruda Fiber 8:42a 9:02a 20 >61* Working on a mixing system Block-up at flat conveyor for the Bag opener. All employees In the area wore 3M 8710 Respirators 172 9:02a 53 0.32 9:55a * Note - filter heavily loaded with particulate actual count would be greater than 60f/cc at water treatment slurry tank. CTD020691