Document LKX4ebyEkdbKQ4Onvo9DGa0Y3

jt n * { S i c. OBJECTIVES 1. Progress report on laboratory biodegradation of PCBs. 2. Residue accumulation studies In fish, birds anfd mammals. v 3. To show reduction in less biodegradable PCBs SB a result of Monsanto actions on sales and products. PLAINTIFFS . . .EXHIBIT NfcV 0 2 7 ^ u MONSANTO PCB ACTIONS 1. Phase-out of PCB sales worldwide in all applications except Dielectrics, 2, Conversion of Dielectric Fluids to more bio degradable PCBs. NEV 027261 740516 DEGREE OP BIODEGRADATION OF PCBs Based on data presented: - Transition in biodegradation occurs around penta-/hexa-ch!oroblphenyl. - Disappearance of all homologs below hexachlorobiphenyl observed, - Penta- and higher TCB determined by Bpecific GLC/MS Test Method. NEV 0 2 7 2 6 2 74PIR17 MONSANTO PCB SALES IN U.S.A (Million Pounds) 1969 1970 1972 (Est.) Dielectrics 37.0 40.5 32.0 All Others 30.0 33.5 - Total 67.0 74.0 32.0 Ntv 027263 740518 EFFECT OF FHASE-OUT POLICY PCB sales reduced In U. S. A. by 30 to 33 million pounds, or ^5^* 740519 NfcV 0 2 7 2 6 4 PCB PRODUCT CHANGES IN DIELECTRICS CAPACITORS 97$i conversion to Aroclor 1016 TRANSFORMERS Elimination of Aroclor 1260 NEV 0272fc>5 740520 PCBs USED IN CAPACITORS PCB Aroclor 1254 Aroclor 1242 Aroclor 1016 Major Use Period 1930-1952 % PCB (Penta- % PCB (Hexa- chloro- and chloro- and Higher Higher 77.0 23.0 1952-Sept. 1971 Oct. 1971- 9.01.0 1.0 O NEV 027266 740521 Capacitor Fluids Vfhy Convert to Aroclor 1015? 1. 9-fold reduction in PCBs of pentachloro- and higher. 2. 100-fold reduction in PCBs of hexachloro- and higher. 3. Minimum industry testing required. N&V 0 2 7 2 6 ? 740522 Capacitor Fluids What Is The Effect of Aroclor 10l6? u.s. Capacitor Fluid Sales (1972)w 20 lbs. If Aroclor Was 1254 TXOu J1iuO 1015 $ Pentachloroand higher PCBs Would Be* 15*^00,000 pounds 1 ,800,000 200,000* Hexa chloroand Higher PCBs Would Be* 4,600,000 pounds 200,000 * 2,000 *This does not mean amounts of PCB entering the environment. n ev 0272&8 740523 WHAT IS CAPACITOR FAILURE RATE? Industry Sources Cite : 0.02-0.2# Fer Year NEV 027269 740524 IP CAPACITOR FAILURE RATE IS 0 . 2 % PER YEAR TTOFfgrgAgST PCB ESCAPE TO ENVIRONMENT* IS -- All PCB Homologs Penta Chloro- and higher Hexa Chloro- and higher Aroclor 1242 40,000 pounds 3,600 400 Aroclor 1016 40,000 pounds 400 4 ^Assumes U.S. Fluid Sales of 20 M Lb./Year NEV 027270 740525 PCBs PRESENT IN ASKAREL TRANSFORMER FLUIDS % PCBS Pentachloro- and Higher Aroclor 1260 100 Aroclor 125A 77 Aroclor 1242 . 9 % PCBs Hexachloroand Higher 70 23 1 Major Use Period 1930-1972 19591968- NEV 027271 740526 PCB CHANGES IN TRANSFORMER FLUID-APPLICATIONS 1. Aroclor 1260 being phased out now. 2. Aroclor 1016 cannot be used. 3. Incineration of scrap PCBs - 1971 Note; Askarel (PCB) transformers are tightly sealed units. NE v 0 Z7 27 2 ^40527 WHAT IS FAILURE RATE IN LIQUID TRANSFORMERS? Industry sources cite: Under 0.2$ per year* * All liquid types - mineral oil and PCB. PCB failure could be less since they are inherently safer. NEV 02 72 73 740528 IP ftSKAKEL (PCB) TRANSFORMERS FAIL ftT 02&/YEAR HOW MUCH PCB IS AFFECTED*? All PCD Homologs . Penta Chloro-and Higher Hexa Chloro-and Higher Aroclor 1254 24,000 lbs. 18,480 5,520 Aroclor 1242 24,000 lbs. 2,160 240 ; (Estimated PCB transformer fluid sales In U.S. ! 12 H lb./year) \ * With Incineration facilities available, not all i these amounts will enter environment. : 1 i i i l f ( NEV 02727* ^ a r\ p n r t ! Monsanto13 Present Program To Prevent Environmental Pollution By PCBs 1. No more sales world-wide except approved dielectric users. 1 2. Restrict over 9756 capacitor l'luid Bales to Aroclor 1016 only. 3 . Restrict PCBs in transformer fluids to Aroclor 1254 and 1242* 4. Continue incineration facilities for scrap PCBs. 5 Encourage dielectric industry through ANSI C-107 to enforce strict environmental control over PCBs. NV 0 2 7 2 7 5 7/ncnn