ANALYTICAL LLT.TBH3, <(12), 633-635 U97 J)
TIU- F-XTRACT10N AMD fCCDVr.RY OF rOLYCULORINATt!) BiriU-iNYLSCPCB) USING t'OKOUS POl.YUitliTUAjJt FOAM
KfY WJMVj PCB, extraction, water, polyurethane foam, pollution
H. D. Cesser, A. Chow, and F. C. Davis Chetistry Department, University ofManitoba, WinnipegCanada
and
J. F. Vthe and J. Relnkc Fresh Water Institute, SOI UniversityCrescent, Winnipeg, Canada
W*T3ACr A (dm and efficient method ha.-* been developed for the extraction and
concent;itl loti cf FOB from water. The method uses porous polyurethane foan co
the absorption column for the PCB which Is eluted with acetone and hexane rr
0.C. nna1yal.
*
iktiwuhctiwi The analysis of chlorinated pesticide residues^ and PCB^ in water
continue to present problems. The extraction of chlorinated pesticides from water with organic solvents^ is tine consuming and can only be done with
93-100X cfilcicncy in a laboratory. The. adsorption of PCB on activated carbon** Jk complete but itsrecovery isvariable, inefficient (25-302) and tin* recovered material is significantly different from the initial PCB. T)u reversed liquid-liquid partition filter de"eloped by Ahling and Jensen-* Hjvc excellent recovery for PCB (93-iOOX) but was limited by relatively low flow rates (<65 ml/rin) and required elaborate preparation as well as vacuum or auction to achieve those filtration speeds. A recent review of the
Rt'hjcct has beenpresented by Thornburg.**
The recent paper by Bowen? on the absorption properties of polyurethane t cants presented a new and simple method of concentrating metallic ions from
383
f Vfin.h* 19 / brA*nrcflU*kl<rr, l.ic. NO PAJJf of jhi work may be reproduced or utilised in esny torn* or by ony menfn, c!'!C''U"i-. o- mcO-oii-. >1. ire* H- q .-fAo'oe-,,n^-d rr. trtrj.ny, o> i>y ony nloimalion itO'-age ond retrieval system, w.thou* r*>* wnlitii |i(rmiu>on ct Ifie oiblishe*.
i J ^ I , < ( 1 i , ( | j j Ii : | ;
(
J
'
MONS C640C8
H. D. GECSER, A. CHOW, F. C. DAV1S, J. F. UTHE, AMD J. REIWKK
?
dilute aqueous solution.8 The results suggested to us that the foams haw ,,
possible absorption capability for trace organic contaalnanrs In water and we undertook to test this for the analysis of PCD in water.
(
j
J
EXPERIMENTAL AND RESULTS
Preliminary experiments showed that polyurethane foam docs extract
PCS quantitatively from water. PCB was removed from the foam by Soxhlct
extraction with hexane. PCB-hexsne solutions were concentrated by slow
evaporation to 2 ml and samples analyzed by electron capture gas chromato
graphy. Water spiked with known quantities of PCB gave about 502 recovery
for the overall method. The loss was suspected to occur through the open condenser of the Soxhlet extractor. Tftis wss verified when e second dean
foam was placed in the open end of the condenser end was shown to contain a
major fraction of the PCB lost.
A simpler and more efficient method therefore was developed using
polyurethane foam plugs designed as culture tube stoppers (diSTo stoppers
from Canlab, Winnipeg). These have a higher density (0.027 gm/em^) but arc
mots porous than the coaatercial sheet polyurethane foam (0.022 gn/em^) used
In preliminary work. The foam plugs (22 tn diameter and 38 am long) were
cleaned by shaking In a. 1:1 hexsne-scetone solution In a stael tube with a
ataal ball. The plugs ware then pushed down 20
I.D. glass chromato
graphic column and washed with 25 ml of ethyl alcohol to roraeve residual
solvent and air. This was followsd by csrsful washing with 200 al of dis
tilled water. The aqueous PCB solution was then passed through the column
with a flow rate of about 250 ml/min without the need of pressure or vacuum.
It was found that 95Z of the PCB was retained by the first plug and a few
percant of PCB vaa retained by a second plug, thus selling tvo pluge a necessary end sufficient column. Water wee squeezed from the foam column prior to the extraction of PCB. The PCB wae eluted from the polyurethane
1 UilP. t av* si t with req., sull 10 c Pci at < Pu!
6* > ChrtC*!H
ur, cul ave Sim alt ant met at
seif
MCNS 064009
POLYCHLORINATED BIPHENYLS (PCD) EXTRACTION A-ND RECOVERY
loot* column with 20 ml of acetone followed by a 100 ml of hexane, care being
taken to waoh down the walls of the glass column. It should be noted that at this stage it ^ significant quantity of HjO (> 1 ml) has been co-extracted with the hexane then a separatory funnel separation of the two phases Is
required before the elutant Is dried with about 20 g of anhydrous sodium
sulfate. The dried elutant was concentrated on a rotary evaporator to
10 ml and a 5 ul sample whs analyzed by C.C. The C.C. used was a Hewlet Packard Model 5750. equipped with a 63N1 electron capture detector operated
at 260OC using a helium carrier gas and a 90Z argon-102 methane purge gas.
Pulse time wos 50 mlcmsec., range and attenuation was 1 x 128. The
6' x 1/4" glaes column was packed with 2Z SE-30, 3X QF-1 on 80 - 100 mesh
Chtoaosorb W HMDS treated at a temperature of 200C. Injection port
temperature was 230C.
^
The results of extraction and recovery of PCS from water by the
urethane foam column are summarized in Table 1 where quantitative cal-
eolations sre baaed on the peak height of 13 resolved peaks, with the
average and mean deviation for each analyais given.
Similar results were obtained with 2.0 pg/llter of PCB In water. It was Iso shown that PCB is not washed out of the foam by water. A complete analyels can be done within one hour. The reaults clearly Indicate the method to be both feat and efficient. The extraction can be performed
!<
j .
! . 1 ! I ' i
t .rv . \ir
re ~vn
'' iriwowmxrwnp-ww*Jme
:
iU i $!
H. D. GBSSER, A. CHOJ, F. C. DAVIS* J. F. UTHE, 'AND J REimc: is avoided) or the acetone-hexane solution can be returned to the laboratory for concent rat ion and analysis.
DISCUSSION The Units of detection and analysis of PCfl in water Is presumably
governed by the amount of water chromatographed through the foam column. The polyurethane foam is not specific to PCB and It will absorb organochlorinated pestlcidec as well and a complex mixture would require some separation?prior to G.C. analysis.
The application of this method to inorganic ions will be reported shortly.
ACKNOWLEDGMENTS Grateful acknowledgment is made for partial support from the
National Research Council of Canada and Manitoba Scientists to Combat Pollution through an Opportunities lor Touch Program grant.
REFERENCES
1. A. Revenue, T. W. Kelley and J. W. Hylin, J. Chromatog. 54 71 (1971). 2. C. D. Veith and G. P. Lee, Water Res. 4, 265 (1970). 3. L. Kahn and C. H. Wayman* Anal. Chea. 36, 1340 (1964). 4. J. J. Lichtenberg, PBC Newsletter, Aug. 20 (1970). 5. B. Ahling and S. Jensen, Anal. Chcm. 4_2 1483 (1970). 6. V. Thornburg, Anal. Chea. 43. 145R (1971). 7. H. J. M. Bowen, J. Chea. Soc., 1062 (1970). 6. P. Schiller and G. B. Cook, Anal. Chia. Acta 54, 364 (1971). 9. J. A. Armour and J. A. Burke, J. Ass. Offic. Anal. Chem. 53, 761 (1970). 10. N. V. Penrlnger and J. E. Westfall, J. Chronatog. 57_, 397 (1971).
as of
D(
Received September 22, 1971 Accepted October IS, 1971
886
MCNS 064011