Document LKKYpGrXwqOwxM6nxQYDGvNE5

II June 9. 1972 q,W. R, Grace Co. industrial Chemicals croup $4 WUjTTCHORC AV.,CAMQni06CjMA9S.0?l*a ^/7_ gjL-jt/ozs 1 Mi*. Richard Gruenbaum Project Leader Environmental Engineering O.M. Scott & Sons Marysville, Ohio 43040 I Dick: . Attached are the results of the fiber sampling done on 30 and 31 May. As you will note, all fiber counts, with one exception, vrere veil below the present TLV of 5 fibers per ml and below or very close to the 1976 TLV of 1 fibers. The exception was the 6th level of the furnace area'where the sample indicated 3.3 fibers per tnl. Apparently, the ' I heat rise and exhaust fans at this level .tend to concentrate fibers as weli as; visible dust. I suggest evaluation of the problem by further sampling at the 5th level and lower'levels. .In the interla, if anyone is required to spend more than a very brief period of time at the 6th level, a respirator is suggested as a precautionary measure. I The 2.1 fibers at the discharge end of the iil drier indicate that the drier room is an rea where more extensive testing is advisable. I doubt if there is a problem but further data should be obtained, I am sending separately, the clips and more sampling heads. Also, Frank'Serafin, our Laboratory Director, is preparing instructions I for constructing a simple apparatus to calibrate your air sampling pumps. Our thanks again for your hospitality. If we can be of further assistance, please call. "........ .H.A. Eschonbach HAEimh Enclosures cc; F.A. Eaton [PLAINTIFF EXHIBIT | t SCO 5202 DOJWRG 00519 EXHIBIT z Kennedy v\ --\ * : t Cpa?o^(t of TEir . TO OATfc- - ilB/iU; ' O.M. SCOTT & SONS MARYSVILLE OHIO Sample 9 Operation or Location SC 1 Turf Builder Bagging sq 2 Rode Bagging SC 3 ; . *, Furnace Area 1st Floor Stoners SC 4 . : Furnace Area 6th Level sc s '-v'* Furnace Area 4th Level . SC 6 , Furnace Area . 2nd Level ' SC 7 Control Room SC 8 . . Discharge End of Drier #1 - Fibers Per Ml (Greater than 5 microns in length) .4 *'4 . ' . 2.1 . ' loili Remarks Difficulties with bagging equipment contributed to dust levels. . #1,2,3,41 8 Operating . ' 8.3 . (1 It . 11 . 1.4 . 1* * II * 1.9 ' 0.0 2.1 11 II f| ' <1 . O 1111 ` :, ! 'V ` ' "r m . , : . : . . " ' " ' . . ' SC DENH003042