FLUID HANDLING EQUIPMENT
Zurn engineers are engaged in the continual development of Fluid Handling Equipment to meet the ever-changing re quirements of Industrial, Power Plant and Process Industries for adequate protection of all units and lines in either inter mittent or continuous operation. A Zurn engineer's approach is always a thorough analysis of the need to be met. Write the Zurn Research and Development Department when you need a new device for a specific purpose or standard equip ment for special installations. Because of the broad background of design and production
experience, and the flexibility of Zurn resources, you will find this organization qualified to manufacture the fluid handling equipment contained in this catalog in metals and alloys (cast bronzes, cut or formed stainless steels, carbon steels, cast semi-steel, monel metal, cast iron; coated, plated or lined adaptations of these metals) to meet specific requirements. To provide for corrosion resistance and special flow characteristics, strainer basket material and perforations are usually furnished to specifications as required for each installation. All products included in the Zurn line of Fluid Handling Equipment con form to A.S.M.E. requirements for metal used in pressure vessel parts, and are thoroughly tested.
PIPE LINE STRAINERS
Zurn Pipe Line Strainers are the most effective means of pre venting equipment damage caused by precipitates, crystalline aggregates, dirt (sediment), scale, filings, or other particle impurities often found in pipe lines conveying fluids. Many shut-downs resulting in costly repair bills can be eliminated by their use.
Zurn Pipe Line Strainers protect pipe lines leading to all types of pumps, traps, regulators, aspirators, injectors, control equipment and valves. Zurn Strainers include pipe line strain-
ers; angle type pipe line strainers for high or low pressure; vertical chamber type duplex pipe line strainers; and for low pressure, the duplex pipe line strainer, horizontal tube type; pressure and suction pipe line strainers with removable basket. All pipe line strainer baskets available magnetic type for the removal of ferrous alloy particles from line. They are adaptable for use on gasoline, oil, water, steam, acid or other fluid conveying pipe lines including systems handling slurries or sludges.
DUPLEX DISC TYPE STRAINER
VERTICAL CHAMBER CONSTRUCTION; FOR HIGH OR LOW PRESSURE PIPE LINE SERVICE-F-158BS
0 This strainer serves a
most important function
where continuous operation
of a line is required.
It is an integral two valve
unit, both valves operated
simultaneously by a large
marine type hand wheel.
This insures ease of opera
tion and effects uninter
rupted and unrestricted flow
at all positions of the wheel.
All flow passages through
out the strainer, from inlet
to outlet, are exceptionally
large and contoured to per
Fig. F-158B5
mit free flow of fluid with minimum pressure drop.
The strainer basket is set
eccentrically, with respect
to the basket chamber, so that the flow section is proportional to the flow
needs at all points, thus minimizing pressure drop. (The usual practice of
setting the strainer basket concentrically, with respect to the basket chamber,
creates a condition of unproportional flow sections with respect to flow needs, thereby increasing fluid friction loss). Regular 6:1 ratio or as specified by
increased "D" dimension.
Valve seats are removable and valve stems are supported at both ends for
accurate, permanent alignment. Covers are removable for lifting out the perforated strainer baskets. Large handhole above each valve assembly for
servicing valves without removing strainer from line. There are no loose
parts on cover. The Zurn Duplex Pipe Line Strainer is a sturdy, efficiently designed
mechanism that will safeguard pumps and equipment from fouling caused
by sediment accumulations in the pipe lines. These units are thoroughly
tested hydrostatically before leaving the factory.
Available in cast bronze, steel, semi-steel and cast iron. Strainer
baskets can be perforated brass, monel or other specified metal.
Mesh or magnetic types furnished to specifications.
A
2' 2 Vi" 3' 4' 5" 6'
B
18%' 18V4' 20 y8" 26r 28 % 36Vs*
c
Min.
24%" 24%' 27%/ 31 '/a * 36%" 40 %
DIMENSIONS
c
Max.
D
E
27'/4*
271/4" 32/,s' 351/4'
42',(6' 47'
10" 12%'
17'/4' 231/0' 241/4"
281/4"
5" 5 5 /a" 5%6i/0-
7%*
F I.P.S.
5' 5" 6" 8" 10" 12"
M
7"
--
8" 91/4* 10" 151/0*
N
--
--
7%' 9%*
-- --
2
DUPLEX PLUG TYPE NON-FREEZING STRAINER
FOR HIGH OR LOW PRESSURE PIPE LINE SERVICE F-158B3 AND F-158B4
This strainer operates by means of a single plug whose orifii direct flow from the inlet to either basket, or both baskets simultaneously. The flow can be diverted from one basket to the other for cleaning without inter rupting passage through the strainer. The seating of the plug into the body is regulated by the relieving yoke which acts to seat the plug tightly
for sealing, or to loosen it for turning, as re quired. This strainer is suitable for working pressures up to 150 lbs. Flanged or screwed connections furnished as required. Bolted covers on strainers over the 3" size; a quick releasing basket chamber yoke assembly is standard on sizes 3" and under. Furnished in brass, bronze, cast iron, semi-steel, steel or special alloys as required for specific services. Sizes: 1", 1 y2\ 2", 21/2"> 3\ 3l/2\ 4", 5\ 6".
Fig. F-158B4
l.1^" Size with Yoke Assembly Strainer Cover
A
I' i'/' i%3 %' 4' 6'
B
6V* 6 Vi' 6 %' 131/4 ' 13 Vi* 18'
DIMENSIONS
C DE
6 Vi'
6 Vi' 6 Vi' 143/4' 143/4'
21 Vi'
14' 14' 14' 27%' 27 /i'
36 Vi'
33/433/4' 33/4' 6 3/4-
6J/4' ir
F
43/4' 43/443/410/4' 10%' 15'
K
8 Vi 8 Vi' 8 Vi' 17' 17' 26'
Fig. F-158B3 6" Size with Bolted Strainer Cover
DUPLEX HORIZONTAL TUBE TYPE PIPE LINE STRAINER
FOR SUCTION SERVICE
Fig. F-157A1-3
FIG. F-157A1-3 --Tested for Maximum Working Pressures
Up to 25 Lbs. Per Sq. Inch
A highly efficient unit where constant flow features are essen tial. The chambers are controlled by an unrestricted diverting or transfer valve. Either chamber can be cleaned while the pipe line maintains its normal flow.
Large open area capacities afford free movement of fluids throughout this unit; 16 to 1 ratio with 12" tubes and 8 to 1 ratio with 8" tubes.
Flat horizontal design makes this strainer par ticularly adaptable to low close-quarter installa tions. Transparent Lucite tubes give the engineer or operator a visual check as to the condition of the strainers at all times.
Strainers are furnished with bronze bodies, handle, caps, tie rod and nuts; strainer baskets are brass, monel or other metal as specified; tubes are transparent Lucite or steel casings as specified.
A Size
1' l'/i' 2"
E
3" 3' 3"
DIMENSIONS
B
1 0 1/4 ' io>/4" 10/4-
F
33/4' 3V4* 334"
C
23 t/e" or 35 W 23'/B" or 3 5 Vi" 23 Vb" or 35%'
G
10%' 10%' 10%-
D
3'%3'%' 3%'
H
6' 6' 6'
3
Angle Type PIPE LINE STRAINER HIGH PRESSURE
Fig. F-170A1
AB Diameter
3' 6' 4' V
C
9' toy,'
FIG. F-170A1 --WITH FLANGE CONNEC TIONS.
For any high pressure line, and par ticularly for vapor, steam, or gas services. Angle construction provides added ad vantage of allowing strainer to be in stalled directly upon the unit that it is to protect--a highly efficient piping system practice today. This unit may be used in sets of two with diverting valves to per mit continuous flow during cleaning peri ods. Available with cast steel body and cover assembly. Open area ratio of basket 4^:1.
DIMENSIONS
D Length
E
F
GH
14%' 6' % 8' % 17' 7' % 8' %
REMOVABLE BASKET
90 OR 180 STRAIGHT THROUGH PRESSURE AND SUCTION PIPE LINE STRAINER
WITH DROP-BOLTED OR YOKE COVER FOR HIGH OR LOW PRESSURES
FI*"1-. ^-50001--Cover is removable for lifting out the perforated strainer basket; cleanout plug furnished to permu blow-down cleaning where applicable. Made in cast bronze, steel, semi-steel or iron, or alloyed metals for corrosion resistance. Right or left hand regularly available. Also mesh or magnetic baskets.
ORDINARILY RECOMMENDED PERFORATION SPECIFICATIONS
Service
Diameter of Holes
Raw Water........................ Filtered Water.................. Heavy Oil.... Light Oil............. Steam, Gasoline, Air . .
. . . .375 ................ 125
.125 ................ 0625 . . . .045
Number Holes Per Sq. In.
8% 33 33 98 169
Proper perforations cannot be recommended without complete installation details.
DIMENSIONS
AB CDEFK
Fig. F-500D1
i%' 2'
2%' 3'
3%' 4' 5' 6' 8'
!% 2'
2%' 3' 3%' 4' 5' 6' 8'
7 %" 7%'
9%' 9%' 11 %'
12'
15%' 153%'
16%'
12' 12%' 14' 1S3%-
16%'
17%' 21S/S' 223%'
25'
4%' 4%' 53%'
5%' 6'
7%' 7%7%' 11'
5>/4' 53%' 73%'
7%' 8%' 10%' 12' 12'
17'
10' 10'
13%' 13%' 14%' 18'
19%' 19%' 28'
90 OR 180 OFFSET PRESSURE AND SUCTION PIPE LINE STRAINER
WITH DROP-BOLTED OR YOKE COVER FOR HIGH OR LOW PRESSURES
FIG. F-500B2--Right angle body connections; cover is removable for lifting out the removable perforated strainer basket; cleanout plug furnished to permit steam blow-down cleaning where applicable. Made in cast bronze,
steel, semi-steel or iron, or alloyed metals for corrosion
resistance. Right or left hand regularly available. Mesh or magnetic baskets.
For Recommended Perforation Specifications, refer to
table above.
DIMENSIONS
A B--Standard Size A.S.A. Flange C
DE F G H
1 'A' l'/z' 2'
2%' 3'
3%' 4'
5' 6'
i%' 1%' 2"
2%' 3" 3%" 4' 5' 6'
4%'
5'Ms' 5'Vis' 5'Ms' 73/is' 10'
12%' 15' 15%'
5l5/is' 7%' 7 5/a' 7'/,'
9%'
15%;' 19%' 215/,' 225%'
3%' 3>%'
3>%' 3=%' 4%" 5'
8'
73/4' 73%'
33/1s' 3%' 3'%'
3'%' 4%' 5'
8'
7%' 7%'
2 "/is' 2'3/is'
2'Ms"
2'3/ls" 4'
5 %' 6'
9'
9%'
1%' 2%' 2%' 2%'
3 lAf," 4 %' 6%' 6'
6"
Fig. F-500B2
4
REMOTE VALVE CONTROL BOXES AND ASSEMBLIES
Zurn Remote Valve Control Boxes provide a modern method of operating inaccessible or hard-to-get-at valves.
Valves located below floor level, close to the ceiling or walls and partitions, inside tanks or processing vessels, or in the midst of complicated piping and equipment, can easily be operated and controlled by the use of a Zurn Re mote Valve Control Assembly, such as is illustrated on this page. This assembly includes a Remote Valve Control Box, and all essential parts for hooking up the control mechanism with the valve that is to be operated, including cast iron rod coupling to fit on hand wheel of valve when specified. These Remote Valve Control Assemblies can be installed to operate with rod or pipe connected by universal joints or with flexible cable as illustrated, for transmitting torque to the handle of the valve unit that is to be opened and closed. The hazards of chain operated valves can be avoided by using these assemblies.
Zurn Remote Valve Control Boxes are particularly adaptable for Industrial, Power Plant, and Processing Industries installations where large numbers and many different types of valves are in constant use.
FIG. F-101A2--SINGLE TYPE HEAVY DUTY REMOTE VALVE CONTROL BOX WITH FLANGE
For attaching to masonry construc
tion, metal or wood partition. Cast body, ground joint seat cover, operating spindle with "open-shut" indicator. Made
in cast bronze, steel, semi-steel or iron. Stem extension and bottom hub can be processed as required for various couplings.
A-Size
5/s' VS
V
DIMENSIONS
Bc
4%' 4%'
6%' 6VS
6 Vs'
D
"/s' "/s' ' fl6*
Fig. F-101A2-7
FIG. F-101A2-7--EMERGENCY TYPE GLASS COVERED REMOTE VALVE CONTROL BOX WITH FLANGE For attaching to masonry construction, metal or wood partition. Cast body, operating spindle with "open-shut" indi cator. Made in cast bronze, steel, semi steel or iron.
A-Size
vs
1'
DIMENSIONS
B cD
5S7V/s,S'
SVk'
7TV/S,'
7 Vi'
%
vVsS
E
ilW''//S2S-
TRIPLE TYPE REMOTE VALVE CONTROL BOX
FIG. F-105A2, TRIPLE TYPE, REMOTE VALVE CONTROL BOX WITH FLANGE
For attaching to masonry construction, metal or wood par tition. Triple type cast integral body and cover with precision machined gasket seat, removable label plate, lock latch, packing gland, and operating spindle and "open-shut" indicator. Made in cast bronze, steel, semi-steel or iron.
Fig. F-105A2
A-Size B
vs Vk'
DIMENSIONS
c DE
\SVS
7" 4'/s'
F 6 VS
G
1214 "
Diagram shows detail of masonry wall installation of Zurn Remote Valve Control Assembly for operating re mote valves. This assembly is made with flexible shaft, although rod or pipe connected with universal joints may be used. Various Zurn assembly units for such an installation are illustrated and identified by figure number on this diagram.
Diagram A: Illustrates battery of Zurn Remote Valve Control Boxes of single and double type bodies pro viding operating mechanism for all types of valves at convenient point.
Diagram B: Zurn Remote Valve Con trol Box with glass cover for special purpose installations.
5
1
/
FIGURE F-101A2-19 ROD COUPLING FOR
VALVE WHEEL
"Y" TYPE PIPE LINE STRAINER
Fig. F-160A2 Fig. F-1S0A1-1
FIG. F-160A2--"Y" STRAINER WITH FLANGED CONNECTION
Cast body; removable perforated strainer sleeve fitted into machined recesses in body and blow-off bushing; threaded blow-off connection furnished, if specified, at additional cost; available in cast bronze, steel, semi-steel or cast iron.
FIG. F-160A1-1--"Y" STRAINER WITH BUTT-WELD CONNECTION
Cast steel body; removable perforated strainer sleeve; threaded blow-off connection furnished, if specified, at additional cost. Made in cast steel only.
Threaded and solder joint types available. Recommended perforations for basket strainers upon request. Mini mum open area ratio 2 V2:1.
A Dia.
B Lgth. F-160A2
DIMENSIONS
B Lgth. F-160A1-I
c F-160A2
c F-160AI-1
I.P.S.
A.S.A. Flange
Zi' J/4' 1'
I>/4' l Vi' 2'
2 Zl 3'
5'/z' 5 y,'
6V*'
7'/z' 9'
10%' 9 Ms*
u zr
4%' 4%'
4%' IVi
7%' 814' 8%' 8>4'
3Ms' 3' 33/4'
3%' 4
5 55/a' 6J/4 '
3'/a' 3Vk"
3/4* 3'3/U'
4 Ms' S5/a' 55/6' 63/'
3/e' 3/e'
3/a' Zi' '/z' 1*
iy*` 114 '
Vz' 3/4' 1'
114'
l'/z' 2'
2 '/z' 3r
DISCHARGE CHECK VALVE
Zurn Discharge Check Valves serve an important function in discharge lines, carrying steam, sludge, waste water and many other waste liquids in gravity flow installations.
Zurn Discharge Check Valves serve as a protection against contamination of liquids, fouling of pumps and equipment, reduce maintenance costs, and prevent production difficulties in industrial plants, wherever back surge is a problem.
Zurn Discharge Check Valves can be furnished in cast bronze, steel, semi-steel, cast iron and alloyed metals for corrosion re sistance.
Many other types available. 105 with or less manual control.
Fig. F-49BI
FIG. F-49B1--180 DISCHARGE CHECK VALVE: Straight type less manual control; also available with manual control; removable swing check flap and cover. Avail able also with I.P.S. outlet. Out let same size as inlet.
Fig. F-44C3
FIG. F-44C3--90 DISCHARGE CHECK VALVE: Angle type with vertical auxiliary manual control; removable swing check flap and cover; removable valve seat; cleanout plug. (Also furnished less control.) Available also with I.P.S. or soil pipe and spigot outlet. Outlet larger than inlet.
LINT INTERCEPTOR
9 FIG. Z-901--This interceptor is especially adaptable to the requirements of the textile in dustry and laundries and industrial plants where lint and wiping waste is likely to get into drain age lines and clog them. It should be used in connection with pumps and in water works and swim ming pool installations, and in water and oil service mains. The interception function is accom plished by a perforated metal strainer equipped with an open or closed bottom, brass or copper basket of suitable mesh. Strainers are furnished plain or galvanized. The intercepting basket is removable, singularly easy to inspect and to clean; however with the open bottom basket, all dirt and sediment can be brought out through the bottom blow-off connection. It cannot be come air bound, as the openings through the high points in the basket are on a line with the top of the pipe. This interceptor is built for operation with working pressures up to ISO pounds. Cast iron body and bolted cover dura-coated. Available with flanged and I.P.S. connections; sizes: 2, 3, 4, 5, and 6 inches.
Fig. Z-901
VOLATILE LIQUIDS INTERCEPTING DRAIN
The Zurn Volatile Liquids Intercepting Drain was specially designed for installations where volatile fluids, having a lower specific gravity than water, i.e, gasoline, oil, naptha, etc. are dis charged into the drain. It is a safeguard against the costly hazards of explosion and fire.
The Zurn Volatile Liquids Intercepting Drain is recommended for installation in automotive plants, railroad roundhouses, dry cleaning establishments, heat treating plants, garages, service stations and other locations wherever inflammable and explosive liquids are used or dispensed.
The large central retaining chamber provides low downward velocity of fluids passing through drain. Fluids are evenly distributed over entire area by dispersing action of safety seal arrangement. Thus a high efficiency of interception and a large retaining capacity are attained.
The extreme length of the Annular Level Maintaining Weirs provides a constant basic liquid level in the drain. This level rises in the central section of the drain as lighter than water liquids accumulate. When these liquids have reached the retaining capacity of the drain, the level has reached the circular skirt of the Automatic Signal Control. This causes a secondary liquid seal and an air lock at the Safety Seal which very noticeably retards the inflow of liquids giving positive indication that drain should be cleaned.
The drain is very easily cleaned by removing the grate, safety seal and signal control assembly, and baffle casting. The container casting is then lifted out and the volatile liquids poured off; then the water and sludge is removed.
Fig. Z-697
Capacities ratings and perform ance data available. Write us for
information on your specific problem.
6
CAST IRON INTERCEPTORS
FOR WAX, GREASE, FATS, AND OTHER LOW DENSITY INSOLUBLES
A positive means of avoiding clogged drains and contamination of sewage outlets.--Figs. Z-l 170, Z-l 171.
The primary purpose of a Grease Interceptor is to assure free flowing drainage through pipe lines at all times--by intercepting, separating, accumulating and recovering grease from waste water lines.
The ZURN GREASEPTOR METHOD, employing the principle of flotation, is the simplest and most positive means of accom plishing this purpose.
The first essential in the operation of this principle is the elimination of turbulence of incoming waste water, allowing the grease to separate from, and rise to the surface of, the water.
Proper construction and specially designed flow control features of the Zurn Grease Interceptor effect maximum separation.
Efficient grease interception is necessary: 1. Reduces plumbing-drainage maintenance costs by keeping lines free of damaging grease. 2. Salvaged waste grease and fats can be sold to rendering plants. 3. Waste grease is vitally needed now as a basic ingredient of war explosives, glycerine, soap and medicines.
4. Guarantees maximum capacity operation of sewage disposal plants, thus protecting life and health of community.
THERE ARE TWO FACTORS THAT SHOULD DETERMINE THE SIZE AND TYPE
OF GREASE INTERCEPTOR SELECTED:
1. The quantity of waste water normally contained in the fixture served by the interceptor, and
the period of elapsed time necessary to empty the fixture--RATED FLOW CAPACITY.
2. The expected volume of grease in waste water discharged by the fixture over a period of time,
and the practical time interval of cleaning the interceptor--RATED GREASE CAPACITY.
Caution should be exercised in the choice of an interceptor since its efficiency is retarded in
proportion to excessive flow through the chamber. Guard against undersizing!
GREASEPTOR
THE ZURN GREASDICATOR
The GREASDICATOR is an easily operated slide-rule em ploying the above factors in sizing and selecting the proper Greaseptor for a specific installation. Proven mathematical formulae have been used to compile the data and information it contains. As a result, selections and sizes are guaranteed to inter cept the required volume of grease.
IntureupUrf (ktiit >ttiim at Surface entirely Turbulence
Cross-section showing operation of flotation principle
Dimensional Diagram of Zurn Interceptor Z-1170 and Z-1171
DIMENSIONS, AND CAPACITIES FOR ZURN GREASEPTORS Z-1170 (STANDARD) AND Z-1171 *(DELUXE) MODELS
G.P.M. Lbs. Rated Fat Size Cap. Cap.
100
4
200
6
300
9
*400
14
500
20
600 25
700 40
**600L.T.25
8 12 18 28
40 50 80 50
Overall
Lgth.
17 Vi' 18VY 21%' 23 VY 27'/i' 301/2' 32/2' 31i/a'
Overall Ht.
Over- Ctr. of Ctr. of Inlet Out. all Inlet to Outlet I.P. I.P.
Wth. Base to Base Size Size
10'
11'/a' Hi/.'
1314' 141/4'
165/a' 181/212 3/4'
91/4' 1214' 141/4-
17' 171/2' 20/4' 23' 22'
31/4'
354' 31/4'
31/4' 41/2'
41/a' 4!4' 4/4'
7 Vi' 8'/a' 8'/a'
83/4' 10/4' 12 '/a ' 14/8'
7"
IVY IVY IVY 1V2'
IVY IVY 2"
11/2-
2' 2' 2' 2' 2' 2' 3' 2'
SOLIDS INTERCEPTOR
INTERCEPTS PARTICLES OF PLASTERjlPlASTICS, METAL CHIPS, GLASS, AND OTHER SOLIDS WHICH CAUSE DRAIN CLOGGING--FIGURE Z-l 180
The Zurn Solids Interceptor is a compact, efficient device that performs an intercepting service beyond anything obtainable with old style traps or improvised devices. It is sanitary, easy to inspect and to keep clean. With a single motion the cover may be removed, providing access to the sediment container which is readily lifted out for cleaning.
The Zurn Solids Interceptor is engineered and built to perform a specific protective func tion where solids frequently clog drain lines. The intercepting function is accomplished by two perforated metal strainers which intercept the solids in the waste water as it passes through the interceptor body.
In addition, they serve as baffles to quiet the turbulence of the water, permitting the solids to drop more readily to the bottom of the sediment container where they are accumulated for removal. The inlet being located approximately 4 inches from the bottom of the in terceptor directs the water upwards near the top on the opposite side, thereby leaving the collected solids undisturbed. Because of water seal in this interceptor, it also serves as a trap as required by plumbing codes.
Zurn Solids Interceptors are available in two sizes.
7
Fig. Z-l 180--Solids Interceptor Size No. 2
ZURN-BENNETT WALL CLOSET CARRIERS
These carriers provide adjustments usually required in the installation of wall closets in industrial, commercial, public, school, and institutional buildings. The sanitary advantages and other conveniences of wall closets may be fully realized when supported by Zurn-Bennett Wall Closet Carriers. They facilitate installation, requiring less time to make adjustments and assure proper align ment of all closets. Write direct for illustrated catalog. Zurn is the only manufacturer specializing in Carriers for supporting all types and makes of wall fixtures, including sinks of all types lavatories, and wash basins. This line includes many basic types of Zurn Engineered Carriers, described and illustrated in Catalog No. 39.
ZURN BUILDING, PLUMBING, DRAINAGE PRODUCTS
Roof Drains, Floor Drains, Backwater Sewer Valves, Shower Drains, Clean outs, Continuous Waste Extension Fittings, Traps of all types are included in the complete line of Zurn Building-Plumbing-Drainage Products which covers every requirement of a modern plumbing drainage system, except the pipe. Zurn Engineers have been constantly improving existing types of drains and developing new ones over a period of years to provide "Engineered Protection for Human Health in Modern Structures." Write for Zurn Catalogs, specifying the particular type of products in which you are interested.
ZURN FROST-PROOF HYDRANTS AND STREET WASHERS
This line includes compression valve, dry pipe hydrants, in three different styles and compression valve, dry pipe street washers. These products are thoroughly pro tected both at the top and the bottom so that they are not affected by frost in the coldest weather. They provide full water flow and are easily repaired. Write for catalog on Zurn Frost-Proof Hydrants and Street Washers.
The facilities of these modern factories are engaged in the mass production of: Building - Plumbing - Drainage Products; Marine Products; Fluid Handling Equipment
SALES REPRESENTATIVES
ARE LOCATED IN THESE CITIES:
ALBANY 5, N. Y. ATLANTA 1, GA. BALTIMORE 18, MD. BIRMINGHAM 9, ALA. BOSTON 16, MASS. BUFFALO 2, N. Y. CHICAGO 54, ILL. CINCINNATI 2, OHIO
CLEVELAND 15, OHIO DALLAS 4, TEXAS DENVER, COL. DETROIT 1, MICH. INDIANAPOLIS 4, IND. KANSAS CITY 6, MO. LOS ANGELES 13, CAL. MIAMI 35, FLA.
MILWAUKEE, WIS. MINNEAPOLIS, MINN. MONTREAL, CANADA NEWARK, N. J. NEW ORLEANS 2, LA. NEW YORK 17, N. Y. OMAHA, NEB. PHILADELPHIA, PA.
PITTSBURGH, PA. PORTLAND 2, ORE. RALEIGH, N. C. SAN FRANCISCO II, CAL. SAN JUAN, PUERTO RICO ST. LOUIS, MO. SEATTLE 4, WASH. WASHINGTON, D. C.