CHAPTER 56
forty years ago. Portahle charcoal heaters were the first type
to be standardised by the American railroads. These heaters
have a cylindrical shape and hold about 30 lb of nall char
coal briquettes in a magasine at the top. The briquettes are
fed by gravity to the fire bed near the base of the heater. The
fire bed is supported by a fixed grate and a small compart
ment at the base of the heater provides space for ashes. A
shut-off slide located at the bottom of the fuel hopper is used
to extinguish the heater, and the fuel remaining in the fire
pot continues to burn until consumed. These heaters are
placed on the ice grate in the end bunkers and are chained
to the bunker sides and grates to prevent tipping. Employees
are instructed to open the ice bunker hatches a few minute
before entering a bunker to service these heaters since they
give off carbon monoxide gas. -
The portable thermostatically controlled alcohol heater
(Fig. 3) has now almost completely replaced the portable
charcoal heaters. This heater was designed about ten years
ago in response to the need for adequate temperature control
and complete combustion. The heater consists of a five gal
capacity cylindrical tank which serves as the heater base and
to which are attached the wick, fuel gage, thermostat, filler
cap, chimney assembly and spring hooks. The. alcohol fuel
is drawn by capillary action to the top of the compressed
glass fiber wick where combustion occurs. The thermostat
assembly includes a bimetal coil which controls the burning
rate by regulating the height of the snuffer plate above the
wick surface in response to the thermostat setting. The
thermostat control pointer can be set from 30 F to 60 F (and
up to 70 F on the latest model) in increments of
deg
and may be locked in a pilot position, where the snuffer plate
completely covers the wick. In this position, burning occurs
only at the slot in center of snuffer plate and this constitutes
the pilot flame. The rated heat output with methanol as the
fuel is 6000 Btu per hr at full burning and 600 Btu per hr at
pilot burning.
During the past few years, methanol has been largely re
placed by a new fuel, consisting of a 2 to 1 by volume mixture
of methanol and isopropanol, which has certain advantages
Rg. 3.... Portable Thermostatically Controlled Alcohol Heater
1962 Guide And Data Book
including increased rate of heat output and
content per tank of fuel. Both the fuel mixture and methanol
are unique liquid fuels in that they burn with no smoke and
with only negligible amounts of carbon monoxide gas beins
released. A number of high output alcohol heaters
Jq.
corporate a copper heat conductor around the wick jacket,
have recently been placed in service and have a rated heat
output of 13,000 Btu per hr using the fuel mixture. The
amount of alcohol purchased by the railroad industry for
use in refrigerator ear heaters is estimated at 2J mHU0D ^
per year.
LTndershing heaters have been installed in relatively few
American cars, but are standard for Canadian cars since they
are ideally suited for the top bunker type car without fans
used extensively by f^nadian railroads. They are attached to
the underside of the car directly below one of the door open
ings and hold about 50 lb of charcoal which is gravity fed
into a fire pot surrounded by a copper coil. The copper coil
contains ethylene glycol which is heated and circulated by
gravity through a long loop of pipe laid around the perimeter
of the ear floor under the floor racks. The gases of combustion
from the heater are discharged to the atmosphere- and it is
unnecessary to enter the car to service the heater. The
output is controlled manually by regulating the air supply
damper. Many Canadian cars are equipped with somewhat
similar heaters which use propane gas for fuel.
The heaters described above, and also special oil stoves are
commonly used to preheat cars before loading.
Most of the mechanical refrigerator cars are equipped with
electric heaters for temperature control and defrosting, hav
ing a total beating capacity of about 6000 watts. A few of tire
mechanical refrigeration systems furnish heat by auto
matically reversing the refrigerant cycle so as to send the hot
refrigerant gases from the compressor directly to the evap
orator coiL
temperature Indicating Devices
Two types of temperature indicating devices have been used in refrigerator cars. Both consist of a liquid filled inwtAHtc bulb located on the floor and/or the ceiling of the car and con nected by a flexible metal capillary tube to a <liaJ indicator mounted outside the car. One type uses mercury under a pressure of 300 to 600 psi, a Bourdon tube to actuate the dial pointer and a bimetallic strip to compensate for temperature changes in the case. The other type uses toluene under a pressure of 16 to 60 psi and three brass bellows' to actuate the dial pointer. One of the bellows responds to the liquid in the bulb and connecting capillary tube, liquid in a second capil lary tube, which is not connected to the bulb bat runs parallel to and is the same length as the first tube, actuates a second bellows which compensates for temperature changes in the tubing. The third bellows compensates for temperature changes in tire case.
Since the Canadian railroads use tariff rules for perishable protective services that are based on inside temperature con trol, nearly all of the Canadian cars are equipped with tem perature indicating devices. The bellows type with two dial pointers (one for top and one for bottom temperatures) is standard for flan^ian cars.
MECHANICAL REFRIGERATION EQUIPMENT
In addition to the usual mechanical refrigeration system components, tire mechanical refrigeration equipment installed in railway refrigerator cars includes an internal combustion engine for furnishing the power required to operate the sys tem. Over 95 percent of the present mechanical cars have an
Railway Refrigerator Cars
595
.n^Iectric drive system consisting of a main generator, -moled to the engine, which furnishes power to several elec-
jnotors. The remaining cars (90 percent of which are of he BFM type) have a direct drive system and obtain megheaical power directly from the engine.
^Tith the exception of a few experimental cars having unjgjslung units, all mechanical cars have, a louvered engine compartment at one end which houses most of the mechanical refrigeration equipment. The compartment is separated from {he loading space by an insulated bulkhead and is about 4 ft wide, the width of the car in length (9 to 10 ft) and the game height as the car (9 to 10 ft).
The system is usually divided into major sub-assemblies in cluding an engine-generatorassembly, a compressor-condens ing assembly, evaporator coil and blower assemblies, a rehigerant control assembly, and an electrical control paneL gpmft of the direct-drive systems have all the components cpfflhtTtwt into a single unit which is mounted in the machinery compartment on a sliding base for ease in installing, inspection
and replacement. Special care and consideration has been given in the selec
tion and mounting of all components because of the vibration and impact forces obtained in freight car service.11
The d<*^gn refrigeration capacity for a mechanical refrig erator car depends primarily on the type of refrigeration service for which the car is intended. The importance of also obtaining the proper balance between refrigeration capacity and the beat leakage rate for the car has been shown by laboratory testa.15
Power and Drive Equipment
Only diesel Anginas have been used in mechanical refrigera tor cars, except that with the direct-drive systems, sparkignition engines using propane or diesel fuel have also been tppH The diesel Anginas include the two- and four-cycle types with 2, 3, 4, or 6 cylinders having a rated output ranging from 16 to 50 hp for electric drive systems and down to 12 hp for direct-drive systems. While most of the diesel engines have a vertical in-line cylinder arrangement, about 25 per cent of the mechanical cars use a horizontally-opposed twocylinder HipwaJ engine. Most of the direct drive systems use a two-speed, horizontally opposed, two-cylinder, air-cooled, spark-ignition engina with propane fueL
The generators used with electric drive systems are con nected directly to the engine and provide 220 volt, 3-phase, 60 cycle current with a rated output from 12 to 25 kw. A majority of the mechanical refrigerator cars have a 20 kw generator connected directly to a 34 hp, 2-cycle diesel; but the trend is toward smaller engines tailored more closely to the actual capacity requirements.
Significant improvements10 in the power and drive equip ment have been made in many of the newer mechanical cars. A static type rectifier charger has replaced the common belt-driven battery charging generator, and nickel cadmium batteries are h^ing used. The brushless type alternator is hang used as the main generator.
One of the latest developments11 to reduce engine main tenance and fuel costs is two-speed operation of the engine. Full engine speed is used for pulldown, and after the car temperature is within a few degrees of the temperature con trol setting, low speed operation is used. This system was first empk>yed with direct-drive systems. With electric drive systems, 60-cycle operation is obtained at full speed, and 40cycle operation is obtained at low speed. Modifications were made so that the generator, battery charging system, electric controls, temperature controls, relays, starters, etc. would all function at both 40 and 60 cycles.
Another improvement11 provides automatic unloading of the engine (by dropping the refrigeration load) rather than Angin* shutdown when the engine water temperature rise is due to high altitude or unusual ambient air temperature con ditions rather than to engine trouble. If the water tempera ture continues to rise, indicating engine trouble does exist, the usual hjgh engine water temperature safety control shuts off the fueL Low oil pressure and engine overspeed protection devices are standard equipment.
Refrigeration Components
Refrigerant 12 is used as the refrigerant in all but about 25 mechanical cars, which have an azeotropic mixture of Re frigerant 12 and Refrigerant 152a as the primary refrigerant and Trichloroethylene as the secondary refrigerant. About 60 percent of the mechanical cars have a single refrigerant compressor driven by a 7)^ 10, or 15 hp electric motor. Nearly 35 percent of the cars have 2 compressors, each of which is driven by a 5 or 7J-6 hp electric motor. With the dual compressor system, there are also 2 condensers, 2 receivers, and 2 sets of valves. The condensing systems are in parallel And ran operate independently. About 100 mechanical cars have a tanHom compressor arrangement with 2 compressors driven by separate belts from a common electric motor. The remaining mechanical cars (about 5 percent of the total) have a tingle refrigerant compressor belted or connected di rectly to the engine through a splined joint, clutch or flexible connection.
The compressors are of several designs11 ranging from the two-cylinder belt-driven type through a six-cylinder semihermetic type and including multiple cylinder open types and hermetic types. Many of the compressors are equipped with unloaders on all or a portion of the cylinders to obtain fully unloaded starting conditions. The cylinder unloaders are also used for refrigerant capacity controL
Both the condenser coil and the evaporator coil are usually constructed of copper tubes and aluminum fins. Electric hoofing elements are usually placed in each of several copper tubes within the evaporator coil in the electric drive systems. An electric heater is also placed in contact with the drain pan and drain traps to keep them free from ice and insure dis charge of the melted frost to the outside of the car. This heater is turned on and offsimultaneously with the evaporator coil defrost heater during the defrost cycle and, during the car heating cycle, is automatically out of the electrical circuit.
With direct-drive systems, heat for defrosting with timer operation and heating of the ear under thermostat control are provided by compressor hot gas discharge. In . addition to passing hot gas from the compressor through the evapora tor, two methods have been used for increasing the compres sor discharge pressure so as to provide additional car heating. One method for raising the bead presure, which is used on unitary mechanical refrigeration systems, is to automatically reduce the air flow across the condenser by means of a damper in the exhaust hood. Another method consists of pasting the hot gas (as it goes to the evaporator) through a portion of a specially designed receiver so as to boil the liquid refrigerant in the receiver. The latter system also provides a re-evapora tor (see Fig. 4) where a coil with hot engine coolant supplies, heat to vaporize any liquid refrigerant returning to the compressor from the evaporator.
Controls and Accessory Equipment
A refrigerant control assembly is frequently mounted on the machinery compartment bulkhead and contains the items shown in Fig. 4.