2 PLAINTIFFS | EXHIBIT | UR-630_____ April 1, 1976 CCMPANY PRIVATE Mr. w .r. Crawford Hogansville Plant SUBJECT* Asbestos Fiber Count Data - April 1, 1976 Asbestos fiber count data for February and March is shown on the attached chart and graphs. The three points for each month represent the high, low, and average counts reported for each month. The small figures within the average circle are the total counts included in the average. The solid horizontal line at the 10 fiber level repre sents the maximum allowable ceiling concentration and the broken line at the 5 fiber and 2 fiber levels indicate the permissible airborne concentration for an 8 hour time-weighted average. The February and March readings have followed the typical pattern. We are still maintaining counts below five but the average is still over two~and"the~high~range still close to a four count. The'end of March saw more readings closer to the three count than in February. We are-now actually running more production with less utility people to do the cleaning. We will have.,to do more special cleaning in order not to expose our-- employees to a creeping higher count. More monitoring will be done in the following weeks to assure as low a dust concentration level as possible~.until.we completely shut down. CountSrin the Finishing department were free* O to .14, which is very, good.' Unless s cmthing unusual develops we will concentrate in the other areas and not monitor theFFiaishigg area. R.Pr Sprayberry--rl. ccs D.R. McNeish L.M. Boulware B.S. Garden L.F. Dieringer a.D. Baxvedl C.R. Owings B.L. Fhilpot Dr. J.G. Wells 501S0C01