Document LJNMLgEq9BK9gpD5XZBypxRM5
PLAINTIFF'S EXHIBIT
UC-3705
Federal Register Volume 38, Humber 66, Paragraph 61.22(e/, (f), ana Paragraph 61.23.
"(e) Spraying: There shell be no visible emissions to the outside air from the spray-on application of materials containing more than one percent asbestos, on a dry weight basis, used to insulate or fireproof equipment and machinery, except as provided in paragraph (::) of this section. Spray-on materials used to insulate or fireproof buildings, structures, pipes, ami conduits shall con tain less than one percent asbestos on a dry weight basis."
"(f) Rather than meet the no-visible-emission requirements of paragraphs (a), (c) , and (e) of this section, an owner or operator may elect to use the methods specified by 61.23 to clean emissions containing particulate asbestos material before such emissions escape to, or are vented to, the outside air."
"6],23 Air-Cleaning.
If air-cleaning is elected, as permitted by 6l.22(f), the requirement of this section must be met.
(a) Fabric filter collection devices must be used, except as noted in paragraphs (b) and (c) of this section. Such devices must be operated at a pressure drop of no more than 4 inches water gage, as measured across the fil ter fabric. The airflow permeability, as determined by ASTM method D737-69, must not exceed 30 ft^/nin/ft^ for woven fabrics or 35 ft^min/ft^ for felted fabrics except that 40 ft^/min/ft for woven and 45 ft^/min/ft^ for felted fabrics is allowed for filtering air from asbestos ore dryers. Each square >arJ of felted fabric must Wc^^ut at xcaet a*. OwuCci, and je at xtaSt one--six teenth inch thick throughout. Synthetic fabrics must not contain fill yarn other than that which is spun.
(b) If the use of fabric filters creates a fire or explosion hazard, the administrator nay authorize the use of wet collectors designed to operate with a unit contacting energy of at least 40 inches water gage pressure.
(c) The administrator may authorize the use of filtering equipment other than that described in paragraphs (a) and (b) of this section if the owner or operator demonstrates to the satisfaction of the administrator that the filter ing of particulate asbestos material is equivalent to that of the described equipment.
(d) All air-cleaning equipment authorized by this section must be properly installed, used, operated, and maintained. Bypass devices may be used only during upset or emergency conditions and then only for so long as it takes to shut down the opsration generating the particulate asbestos material."
UCC 006268