Document LJEE65re4YJna0edLo7zqp537

FILE NAME Owens Corning OC DATE 0000 DOC OC046 DOCUMENT DESCRIPTION Sales Literature ee Eww OAR PLAINTIFF'S CEM EXHIBIT OCF 4- es and General Products Division Toledo Ohio C Division PO Box 89. Santa Clara California "m "m Pro * 30 . 10 & ng ee HEAT HEAT INGULATION INGULINGA ULATT ION IINGULATO ION INN GULATION Kaylo Heat Insulation is easily cut with ordinary tools Boiling water does not break it down Light weight combined with high strength KAYLO HEAT INSa ULATION | Kaylo Heat Insulation is made of chemical compound of lime and silica developed by Illinois Glass Company Although not glass it is made of materials similar to those used in glass and with which Illinois has had long experience The technical name is hydrous calcium silicate Since it is a chemically reacted material it contains no added binder For mechanical effects a small amount of asbestos fiber is included at the time of manufacture Few materials have been so thoroughly tested OwensIllinois began work on hydrous calcium silicates in 1938 but no material was offered to the general market until 1943. . Thousands of installations since that time havo proved field superiority yet research and product development are still continuing Kaylo Heat Insulation is made both as block and as molded pipe insulation with the widest range of sizes forms and thicknesses of any high temperature insulation available Kaylo hydrous calcium silicate combines the most desirable physical characteristics of heat insulat- HYDROUS CALCIUM SILICATE be used for high temperatures which usually require combinations of two different insulating materials The low coefficient of conductivity or k of Kaylo Heat Insulation places it among the most efficient insulations for temperatures up to 1200 The name Kaylo is derived from the fact that k is low for the material Its high insulation value comes from the extremely small pore structure So small and numerous are its insulating air spaces that they present a material internal surface of approximately 100 acres per cubic foot of insulation Water does not break down Kaylo Heat Insulation Even when saturated it retains an appreciable percentage of its strength After being soaked for long periods of time and then dried it returns to its original thermal efficiency and strength without apparent shrinking or warping Kaylo Heat Insulation is effective after long service It remains strong and efficient over the years and shows little shrinkage after exposure to temperatures up to 1200 APPLICATION ing materials to a degree not equalled by other materials on the market This means outstanding outstanding performance and economical application for the user PERFORMANCE With a weight of only 11 pounds per cubic foot handling shipping and application are simplified Kaylo Heat Insulation has flexural strength compressive strength and resistance to abrasion far above normal Kaylo Heat Insulation is effective up to 1200 performing efficiently on temperatures through the hot water and low pressure steam range and also through temperatures in the heated steam range Therefore a single material can requirements for heat insulation Breakage during installa- ' tion therefore is usually negligible sawed with Block or pipe insulation can be cut scored or ordinary tools of the trade The material is irritating to the skin and toxic PHYSICAL CHARACTERISTICS DENSITY .Approximately 11 lb. per cu ft FLEXURAL STRENGTH 50 lb. per sq in COMPRESSIVE defoar t5m dea fot rmiatoionn Before heating secu 150 lb. per sq in After heating for 24 hours at 750 F..e. ee eee 144 lb. per sq in at 1000 123 eceeeee eae lb. per sq in at 1200 ... cece 117 lb. per sq in After boiling for 24 hours while wet be .74 .74 lb. per sq in LOSS IN WEIGHT After heating for 24 hours ' of 750 .... .5.5 .5.5 at 1000.. eee cess see e ease .7.9 .7.9 at 1200 .. .9.8 .9.8 After boiling for 24 hours after drying 0.2 RESISTANCE TO ABRASION Conventional tumbling loss in weight after 10 minutes Before heating . cc. c cece ee .2.2 .2.2 After heating for 24 hours at 750 Cee e eet .3.7 .3.7 at 1000 F eee ec eee ee eee eee 5.7 at 1200 eve t eee eeeeeees .6.9 DIMENSIONAL STABILITY Linear shrinkage after heating for 24 hours at ...... .. ..... . f. or .0.8 .0.8 at 100 F.. .0.9 1200 F eee eee ceeeeeaees 1.5 Elongation after saturation max .0.04 MOISTURE ADSORPTION volume After 6 hours exposure in atmosphere of 120 F. and 90 Relative Humidity . 0.9 CONDUCTIVITY K At 100 F. mean temperature .0.35 .0.35 At 500 F. mean temperature .0.54 Applicators like its light weight and good handleability TYPICAL APPLICATIONS Inside or outside for temperatures up to 1200 Kaylo Heat Insulation is used for such equipment as Autoclaves Kilns Boilers Breechings Lehrs Locomotives Chilling Pits Condensers DryerDsryers EvaporatorsEvaporatEvaoporratosrs Furnaces Heat Exchangers Hot Air Ducts Ovens Precipitators Process Equipment Lines Steam Lines Tanks Towers Turbines Vessels 6+ Thermal Conductivity K Stoy - sq ft Ffr v I \ * ~ . | CONDUCTIVITY K a a .50- | a an a a .39 150 200 250 300 350 400 450 500 550 600 650 700 750 Mean Temperature F Strength of material and large units mean more economical application less waste The smooth surfaces and straight edges of the material help make a neat finished job Pao na 'Se 9 ere ae PIPE INSULATION < Kayla ments Pipe Insulation reduces features because of two features inventory require- its wide effective its wide effective temperature range up to 1200 and its Simplified Dimensional Standards which allow nesting Kaylo Pipe Insulation is produced in Simplified Dimensional Standards of thicknesses dia- meters for pipe sizes from a to 23 Oa. nd D.'s of insulation correspond to 0. D.'s of standard pipes assuring proper fit for each pipe size and for nest- ing when necessary With this system of snug nesting Kaylo Pipe Insulation fits all operating conditions requires less items reduces mainten- ance stock a oo Where Where plant operating operating economics economics greater insulation thicknesses consult data in Kaylo Information Files demand detailed Unshaded Lo} = surface temp under to ^ Light Shaded - surface temp 140 to 115E 115E Heary Shaded = surface temp 115 to 10 F Note that shading indicates different surface temperatures DIFFERENCE DIFERENCE HOT AIR TO DEG 200 300 400400 | 700 900 1200 1 3 3 % | 1 4 LT 1 2 2 2 3 3 1 tyr 1 2 3 3 1... % 1 2 2 1... + rod ! % \ 2 IN | 2 22 3 3 1 pa 12 23 3 3 2 } SIZE . SIZE 2 PV 1 22 2 2 3 | 11 2 21 2 3 3 3 3 3 3 PIPE 3 1: 1 17 2 2 3 3 3 PIPE 3 1 1 1 |] 23 3 + NOMINAL 4 ts; | 1 2 2 2 3 3 4 4 6 NOMINAL NOMINAL NOMINAL 10 1 11 1 1 1 1 1 1 2 2 2| 2 2 2 3 2 2 3 3 4 3 3 33 4 2 3 A 4 4 4 4 4 1 1 1 2 14 1 ' 12 2 16 1, fl'2 1 1 . la] 2 2 72 1 1 11 1 2 2 3 4 2 3 0 3 2 2 3 2 2 3| 3 3 4 3 3 & 33 4 q 4 4 S 4 5 4 4 4 S Standard sizes thicknesses and forms | selection Kaylo Pipe Insulation is available as a standard item in sec conformance with Simplified Dimensional Standards tional and segmental forms and in thicknesses through NOMINAL ' PIPE SIZE | NOMINAL THICKNESS OF INSULATION ~~ : i. - 4 os 4 G . |Ya . 9 ; : ; PIPE 1 2 2 3 4 4 5 0.0 Actual O.D. | Actual O.D. 1/2 3/4 | tT | 1...| 1.00 | 2.88 1.56 | 4.00 1.05 .90 2.88 | 1.46 4.00 1.32 1.66 3.50 | 1.58 3.50 1.40 4.50 | 4.50 Actual O. Actual O.D Actual O.D. Actual Actual 2.06 | 5.00 1.96 5.00 2.17 5.56 2.35 2.24 2.64 5.56 2.88 6.63 5.56 2.77 | 6.63 6.63 7.63 1.94 5.56 | 6.63 2.97 | 7.63 0. | Actual 0. Actual O.D. | Actual Q.D. 1[ 2 | 2| 3 1 3| 4 4| 5 1.90 2.38 2.881.98 3.50 1.03 4.00 4.50 175 5.00 78 5.56 4.00 4.50 1.5 5.00 1.31 | 5.56 | 1.53 5.56 | | 6.63 6.63 7.63 | 1.28 1.53 1:28 | 1.82 | 5.56 2.00 1.84 | 6.63 2.03 | 1.78 7.63 2.03 7.63 8.63 1.78 | 2.00 2.35 6.63 2.59 2.85 | 7.63 7.63 3.09 3.59 2.34 | 7.63 7.63 2.53 8.63 2.84 | 8.633.34 3.03 9.63 3.59 7.63 8.63 | | .28 2.53 2.78 9.63 3.09 6.34 10.75 3.59 8.63 2.28 | 9.63 2.84 | 10.75 2.34 9.63 10.75 11.75 | 9.63 9.63 4.16 3.91 10.75 4.09 10.75 11.75 4.09 11.75 12.75 61890- 6.63 61890- | 7.63 61890- 8.63 61890- | 9.63 8.63 3:44 9.63 2.0 2.00 10.75 2:50 | 11.75 2:00 12.75 3:63 14.00 4.13 10.75 11.75 12.75 14.00 15.00 11.75 12.75 14.00 15.00 16.00 a 1.50 12.75 14.00 15.00 16.00 17.00 10.75 10.75 11.75 4.66 4.41 4.59 11.75 12.75 4.72 12.75 14.00 15.00 16.00 17.00 18.00 4.63 11.75 11.75 12.75 12.75 14.00 14.00 15.00 16.00 17.00 18.00 19.00 5.16 4.91 5.27 1.97 5.22 4.97 5.13 10 11 4 12 14 10,75 11.75 12.75 14.00 56 14,00 2:06 15.00 2:56 16.00 3:06 | 17.00 2.56 18.00 4:06 | 19.00 4:56 | 20.00 5:06 15.00 16.00 17.00 18.00 19.00 20.00 21.00 71) 16.00 17.00 17.00 18.00 18.00 19.00 19.00 20.00 3-65 | 20.00 21.00 21.00 22.00 22.00 23.00 15 15.00 16 16.00 17 17.00 18 18.00 1.42 18.00 1.92 19.00 2:42 20.00 2.92 21.00 3:42 22.00 3.92 | 23.00 4:42 24.00 4.92 19.00 20.00 21.00 22.00 23.00 24.00 25.00 1 20.00 21.00 22.00 23.00 24.00 25.00 126.00 aD 21.00 22.00 23.00 24.00 25.00 26.00 19 20 21 22 19.00 20.00 21.00 22.00 1.41 22.00 23.00 1 7 1.41 24.00 25.00 1.91 23.00 24.00 25.00 26.00 2.41 24.00 25.00 26.00 2.91 25.00 26.00 3:41 26.00 23 23.00 1.41 26.00 SESCTEICOTNAILONAL SEGMENT i } Vv SINGLE LAYER ONLY SINGLE MULTIPLE LAYER ONLY OR DOUBLE i LAYER TT, KAYLO KAYLO BEVELED LAGS A For pipe sizes greater than those indicated above Kaylo Beveled Lags may be used These lags are blocks of Kaylo insulation nominally wide beveled to fit snugly on standard sizes of \ 23ak Width- " Nominal heated piping Lags beveled to fit pipes from 21 to 36 in diameter are available in thicknesses of 2 2"and 3 Lags are 36 long KAYLO KAYLO PIPE INSULATION Insulation Insulation Insulation Insulation Efficiencies Eficiencies Eficenis Efficiencies Efficiencies : Eficiency x Bere Pipe Heat Heat Saved By Insulation Lin.Ft. | Efficiency x Bare Pipe Heat Heat Loss Saved Insulation BTU Lin.LinF.Ft.th.r Efficiency 70 123475678980 123475678980 123475678980 123475678980 jjiiii 856 jjiiii jii . 90 , 3 jjiiii 95 jjiiii jjiiii jjiiii jjiiii 00000000 jjiiii ji jii 10 jjiiii 000 100 000 00000000 0 0 0 DIF 0 0 0VOM Yaa Li2Y >=000 wr AIR yeneLL SN ou 230000 RAL ES A 10 0000 00000000LLL 00000000 0000 0 0 0 i ] is SSCN L. Ga N4 S MAIS : N A F < qLY N Fa h at ant S N aay REEAINISAERAD 4 N \ aa, N. NON SKA LK AY i 400 LY TO TEMP VV G26 cee SITTIN ANANAN BN 500 7A i NS SN A IN 1 NK Bae, LN A iT PIPE RE NSSNASERNS tf NT SONATAN LN CELA Sty 600 q NC N > N y j [ N A Net PVP AZ 700 iz Wel AS he 2 \ fi N7N)7) . MA va KAA ANA IN | 234568 18 Pipe KEY TO CURVES Size 1 1.123324568 2333244568 23324568 2333244568 23324568 2333244568 234568 234568 2324568 10121416102100122141261022024224 iN glare KA[7 RINA Lo Lo) ry LH . \ | \ 7 1 THICKNES 211 2 J 3 % i2? 2 4 6 7 4 89 657 10.10 10.10 6 11 12 1 S 3 8 198 10 10 12 11 12.13.14 14 12.13.14 15.16'17 14:14 15 15.16'17 15.16'17 [> INSULATION [i 15-16 17 17 16:17 18 47 . sr , 10 9 10:10 12'12 12 12 12 12 12 14 14 15 16 15 15 15 15 15 15 14 16 17 18 17 17.17'17 17.17'17 16.17.17 17 18:19 18 19.19 19:19 17 19.19 20 20 20 20 20 20 20 18 19 20 20 20 20.21'21'21-21 20.21'21'21-21 19.19.20 20 21 21,2211,21 21,22 a i FA | Z \ IT <> ra i Lt Z A Pa 1 brwo) SUNN pqol-4 TE YY NN KY \ i 4 Vk & 1\, \N Wi eat NR) ONUQ 77 bart \fi ji. 17.18 19 19.20 2020 22 22:22 Bare Bare Pipe Heat Loss BTU per lineal foot per hour Still ambient air 80 100 0 100 200 8 8 8 8 8 8 1100 1200 f Temperature diff deg F. pipe to air 100 | 200 | 300 | 400 | 500 | 600 | 700 | 800 | 900 | 1000 | 1100 | 1200 55 3/4 67 1 82 136 167 206 247 304 373 394 483 595 581 716 884 820 1013 1252 1120 1381 1709 1482 1835 2275 1929 2391 2967 2469 3064 3805 3115 3869 4809 3882 4825 6002 SIZE PIPE NOMINAL | ; 1... 102 255 464 741 1103 1565 2139 2851 3722 4778 6044 7547 114 114 2 2 115 141 168 289 355 423 526 647 773 841 1036 1240 1252 1546 1853 1780 2199 2639 2434 3013 3619 3247 4022 4945 4242 5260 6330 5448 6761 8141 6894 8562 10317 8613 10700 12904 3 202 3 228 4 255 . 4 281 502 575 642 708 930 1052 1176 1298 1493 1691 1892 2090 2234 2533 2836 3137 3186 3616 4051 4481 4373 4968 5570 6164 5850 6649 7458 8258 7663 8714 9780 10834 9863 11222 12599 13962 12507 14236 15988 17724 15651 17822 20022 22201 ur 6 8 10 12 14 16 18 20 22 310 364 464 572 671 731 828 926 1022 1117 782 920 1178 1447 1699 1851 2098 2348 2592 2835 1435 1691 2169 2668 3137 3419 3877 4344 4797 5250 2312 2728 3506 4318 5086 5544 6294 7059 7800 8539 3472 4965 6834 9161 12022 15500 19680 24659 4100 5870 8075 10848 14248 19763 23347 29267 5280 7570 10443 14024 18436 23801 30261 37955 6512 7675 9350 | 12912 | 17355 | 22833 | 29500 | 37525 | 47089 11031 15243 20505 26993 34891 44402 55742 8374 | 12042 | 16649 | 22403 | 29502 | 38143 | 48557 | 60967 9514 13692 | 18941 25499 | 33597 | 43451 55330 69493 10672 15374 | 21277 | 28660 | 37775 | 48873 | 62249 78204 11806 | 17009 | 23554 | 31742 | 41848 | 54161 12935 18642 25829 34817 45917 59439 69003 75746 86704 95196 24 1213 3078 5706 9286 14071 -20291 -20291 28122 37917 50023 64771 82564 103784 <q The complete range of standard widths up to 18 and thicknesses up to " allows Kaylo Heat Insulating Block to be used as single layer insu- lation for flat surfaces up to 700 and in double layers from 700 through 1200 even in temperature ranges which usually requires two thickness of dissimilar materials Pp Recommended Thicknesses Thicknesses : in inches TEMP DIFF HOT SURFACE TO AIR DEG F. Dem 200 | 300 | 400 | 500 | 600 700 800 900 | 1000 1100 | 1200 Thick- ness | 122 1122 1122 1111 122 2 12 11222 22 233 324 425 425 Unshaded [_]= Surface temp under 140 Heavy shaded = Surface temp 145 to 150 Standard Sizes and Thicknesses in inches Thicknesses , 12 23 Widths 6 12 18 Length 36 $ Curved block and thicknesses over " available only on special order Applying Kaylo Heat Insulating Block to locomotive boiler using tie wires Insulating ducts and boiler at power plant using laced tie wires and wire mesh for finishing cement ? a | Drying oven installation using studs and speed clips for fastening insula- tion HEAT INSULATING BLOCK Heat Loss Surface Temperatures and Efficiencies 100 99 97 96 CENT CENT 95 CENT PER 222 PER EFFICIENCY 222 EFFICIENCY EFICIENCY 222 EFFICIENCY EFICIENCY 91 EFFICIENCY 90 89 88 87 86 350 300 HOUR 250 200 SQUARE 150 LOSS 100 v . HEAT aS 50 eo 9 Efficiencies on Flat Surfaces : : AMBIENT AIR B0 THICK 100 200 300 400 500 600 700 800 900 1000 1100 1200 Temperature Difference Flat Surface to Air F Heat Loss from Flat Surfaces and Surface Temperatures of Insulation AMBIENT STILL AIR 80 " THICK 200 210 THICTKHICK ele BROKEN LINES SHOW SURFACE TEMPERATURE OF INSULATION 100 200 300 400 500 600 700 800 900 1000 1100 1200 Temperature Difference Bare Surface to Air F For Additional Information Write CORNING FIBERGLAS CORPORATION NICHOLAS BUILDING TOLEDO 1 OHIO eeeeseneeoeeeeo on vsn eae ans sne tee ees nse ed RICHMOND INSULATION SALES CORP 54-18 43rd Street Maspeth N. Telephone RAvenswood 9-6408 ~ ig c POE erat mae = et ee A ~ - ae On cena - ~ . Bo eben ee 8 Keyic pipe insuleti IN1.C5 June 1956 an high temperature insulation for indoor and outdoor piping up to 1200 operating temperature Kaylo pipe insulation Kaylo Pipe Insulation a white rigid hydrous calcium silicate heat insulation manufactured by Illinois Glass Company Company and distributed nationally by Corning Fiberglas Corporetion effectively insulates indoor and outdoor piping up to 1200 This thoroughly tested and proven material contains the physical properties most desired for efficient durable insulation work Kaylo Pipe Insulation's thermal effectiveness high strength and moisture resistance are unattained by most other insulating materials A chemically reacted material Kaylo Pipe Insulation contains no added binder For mechanical effects a small amount of asbestos fiber is included at the time of manufacture jackets canvas Sectional Pipe Insulation includes standard canvas jackets at no additional charge on thicknesses up to and including 2Standard canvas is available on segmental forms at a slight additional cost Bands are available for use with this product at slight additional charge and will be furn- ished on request 6 oz and 8 oz canvas jackets are available for all types sizes and thicknesses of Kaylo Pipe and Tube Insulation at an additional charge These jackets are factory applied on Sectional Pipe and Tube Insulation On segmental forms they are furnished but not adhered thickness Pipe Insulation is available in thicknesses from " to de pending upon pipe size Kaylo Tube Insula- tion is available in thicknesses of " and 1 pipe sizes Pipe Insulation is available to fit pipe from to 39 in diameter Kaylo Tube Insulation will fit copper tubing from to 3in diameter forms Pipe Insulation is available in sectional or multisegmental form depending upon pipe size All insulation is furnished in 3 sections T M. Illinois Glass Co. offers high efficiency Among the most efficient insulations for temperatures up to 1200 Low k results from extremely small and numerous insulating air spaces simplified dimensional standards are designed to permit nesting of one size over another to produce greater thicknesses than available in single layer or to produce bro- ken joint concept water resistance Pipe Insulation retains an appreciable percentage of its strength even after complete saturation in water After a cycle of soaking and drying it returns to its original thermal efficiency and strength with no shrinkage or warping high strength flexural strength compressive strength and resistance to abrasion far above normal requirements for heat insulation greatly reduce installation and service breakage easy fabrication tools of the trade sufficient for all cutting sawing or scoring irritating to the skin and toxic Offers pleasant handling characteristics long Remains strong and efficient over the years Dim- ensionally stable with little shrinkage Has superior life characteristics over other types of high temperature insulations versatility efficiently at temperatures through the hot water and low pressure steam range in addition to tem- peratures in the superheated steam range One high temperature material to do the job usually requiring combinations of two different insulating materials limitations 42 012 0759 Kaylo Pipe Insulation is designed for temperatures up to 1200 and is not recommended when operating temperatures of piping exceed this limit it's the low that counts 35 a IS onan ee een eo ee eee eee ee me ene eremny -- eer gua physical properties density .. approximately 11 lb. per cu ft flexural strength ..50 lb. per sq in compressive strength at % deformation before heating .150 .150 lb. per sq in after heating for 24 hours cc. eee at 750 eee 144 lb. per sq in in at 10ce0 ce eee0 123 lb. per sq in at 12 0...0 cc eseae0 e 117 lb. per sq in after boiling for 24 hours while we se cet eeen .74 lb. per sq in loss in weight after heating for 24 hours at 750 eee eee ec ee cece ence 5.5 at at 100 cs0 cece ere 1200 00... eee ee e ere eee ne e eens eee ees 7.9 9.8 after boiling for 24 hours after drying .0.2 resistance to abrasion conventional tumbling test in weight after 10 min before heating ces cee eeees vase. after heating for 24 hours 2.2 at 750 eee ee eee eee eee eee 3.7 at at 10 10 00 1200 be ee ene e sewer eaeceee 5.7 6.9 dimensional stability * linear shrinkage after heating for 24 hours at 750 cece ccc ee eee ea ees 0.8 at 1000 Leaseccceeesecceses 0.9 at 1200 cece cece cee ee ees 1.5 elongation ofter saturation max .0.04 moisture adsorption volume after 6 hours exposure in atmosphere of 120 and - 90 relative humidity .0.9 thermal conductivity x o o e fi Thermal Conductivity T taCondf uctivity F e f Lt] + CONDUCTIVITY x~ > yp be Lt La Ly 8 a - Gu a _ i 150 300 454 Mean Temper^F. 650 TH specification compliance 1-523a Insulation Block Pipe Covering and Cement ee vies 8 % -_ Thermal Calcium Silicate For Temperatures up to 1200 1-2781B Insulation Pipe Covering Thermal 2 aa we fe - Kaylo Pipe Insulation applies easily and quickly with standard applica- tion methods Kaylo Pipe Insulation presents a superior final appearance when opplied to a variety of irregularly high temperature vessels desidesign gn data a design nat tata) ccoweme" The following data is presented to aid in the design of Kaylo Pipe Insulation modified to meet specific needs Recommendations are generalized and should be modified to meet local conditions and job requirements recommended thicknesses Economical thicknesses of insulation vary to a substantial degree in different industries principally because of 1 : Cost of fuel and operation time 2 Fixed charges or anticipated life of installation Because these two factors vary greatly by industry a single table of recommended thickness would be only an approximation To approach more closely a true Economical Thickness the recommended thickness data on the following three pages is presented for three major industry groups 11 Commercial and Industrial 21 Power and Utility 31 Process and Industries exceptions Economical Thickness recommendations may not apply where insulation is applied for process temperature control personnel protection or fire protection for specific areas Refer to Kaylo Performance Data Book for insulation design for such conditions See pages 37-39 insulation thickness standards This table presents reference data for information on the actual thicknesses according to the simplified Dimensional Standard system See pages 40 41 insulation efficiencies This table and graph enable making the determination of thermal efficiencies for thicknesses from -5 for pipe to air temperatures from 100 to 1200 See page 41 42 012 0760 om r Ch Por Cee ee _ design data ommended thickness of Kaylo pipe insulation COMMERCIAL AND INDUSTRIAL DESIGN } Figures are based on ambient still air at 80 F pipe temp temperature difference . me nad wee I pipe size : wae Ve et RT 280R Ye OTB TE MANGA PA CINE 2 mur FO eres ne De, 200F ; ee mere we wi ws ee tece eee tee emmy wed aw enn ote ae HL E ST RT | HL 480F > meen rm WTS CUES II LUT prem 680F me ... ... SFE ...ETE tre aan renee 400F 1 : 1 Pe ee E er ee ee ST 600F . De hee te re eee ek ek St tee + { RT HL E ST 1 % 1 - 1 32.5 76.1 106 2 38.9 767 110 2 40.8 80.2 107 2 | i DO i 59 | 64 t 1 86.8 87.8 =} 89.2 L 105 108 107 2 2 3 73.3 81.8 86.0 91.1 91.9 93.1 107 109 107 1 1 1 1 1 38.0 42.6 48.3 85.1 85.3 86.4 99 101 101 2 2 2 67 73.9 79.5 i 91.0 91.2 92.3 105 107 | 106 3 3 3 93.0 94.1 97.8 94.5 + | 108.0 95.1 106 107 b 108 2 + n 1 11 1 1 1 1 50.0 63.7 76.8 88.2 87.5 88.0 99 103 105 91.4 107 116 i 88.3 88.4 88.9 | 106 107 107 00 1 129 89.0 107 9 12 142 89.1 108 10 1 151 89.6 107 12 1 174 89.8 108 14 1 202 89.1 110 16. 2 182 91.3 104 2 2 2 94 102 _ | 120 92.4 93.2 / 93.7 110 109 | 110 3 . 124 . 94.6 3 141 ' 94.8 i 3 : 152 - 95.1 | i : 3 ; 167 > 95.2 3 181 | 95.4 3 : 200 95.4 ! 3 3 343 206 227 253 95.9 95.9 960 106 108 107 108 109 110 107 108 108 3 4 A 115.0 125.0 145.0 4 4 4 164.0 172.0 188.0 4 4 S 206.0 222.0 226.0 5 S 515 256 280 295 95.6 96.1 96.4 107 107 ; 109 96.7 97.1 97.2 109 107 108 97.3 97.4 97.6 109 110 108 97.7 97.7 97.9 109 110 | 108 18 2 202 91.4 104 3 280 96.0 20 2 222 91.4 104 3 305 96.1 - 24 2 262 91.5 105 3 358 96.1 ra =. -Recommended Thickness Heat Loss Blu ft./hr Insulation Efficiency Surface Temperature it's the low 109 109 110 5 5 5 321 350 400 97.9 97.9 98.0 109 110 110 42 012 0761 counts 37 oo - _ -- ping to 1200 vio pipe insulation insulation design data at autho autho eee recommended thickness of Kaylo pipe recommended POWER AND UTILITY INDUSTRIES Figures are based on ambient still air at 80 F insulation 2 ) e temp temp perature Terence w~ were weteeTHLE THLE size THLE pe size " 3/4 " - i 280F r 7 ery 200F THLE THLE STTHLE STTHLE THLE THLE THLE STTHLE 32.5 | 76.1 | 100 76.7 110 40.8 80.2 | 107 480F ae gaat 400F - STTHLE eal lsseaee STT STTHLE STTHLE STTHLE im "| 584 85.2 ! . H 113 | 1 67.4 86.0 117 | 1 73487.7 73487.7 116 i 680F a Aaeniel 600F =e - tees = - HLE HLE HLE | HLE ova 2 836 89.8 : 1 ! 2 . 90.01 90.01 | 95.0 g | 103 91 1 1000F 1280F 880F 1080F age AT RA INT A ITT epee en nee cae TEN OE 1 ge SHORE TET 1200F 1000F 800F = . rae en ST + -e ae THE ST THE 1 ST THE THE S HL E . ST THE THE THE ov! 93 118 2|104 t H 122 2116 937 i | 121 2 132 04.2 | | ' 116 120 124 12694.6 3 12694.6 | : 116 4 ! { 3 143 95.3 ~ | 3155 | } , 95.8 122 ( ' | 3150 : i ! : 3170 961 i 96.5 115 123 3193 96.8 125 i { ! : et 1 " A o~ 1 2 M " . " 52.0 79.6 | 113 2.6 | 81,8 110 60.B | 82.9 111 69.9 83.5 112 82.6 83.7 114 98.2 | 84.7 114 ! 82.2 189 1889 - | 1 | 1| 923 890 | | 1%; 105 89.9 . i | 2 108 ! i fy 121 b 122 2119 | 2128 93.1 ' 93.3 | 94.2 117 121 119 1 | 2 108 116 139 1 91,3 F \ | t 92.2 t \ 92.7 ' i 117 115 118 : ' 1 2151 1 94.3 21 ': t ' 2164 , ! ... 172 ' 949 \ 95 123 118 3 140 | 851 : ' ' 3 f 155 95.3 ! , + 155 959 . 122 125 124 3172 i 3 178 96.6 : F) 96.8 1 ; 4 | 190 97.2 : 124 A 1 ' 203 \ j 122 14 | 206 ! ! 121 | 4228 97.4 i 97.6 i 97.9 . 125 121 125 3 164 96.1 . ' 3 ' | ' 190 ' i | 3222 i | 96.8 i ' 97.0 ' \ fp 122 4 i 204 , 121 4 222 : 124 4... 252 ; 197.5 . 121 97.7 : 98.0| 123 1 14 14 : 5 245 ! ! 08.1 i i 263 98.3 ' ' 15 295 : 984 125 124 125 5 6 7 8 9 10 12 14 16 18 22 22 1 120 84.7 | 116 ... 156 | 83.0 122 | 1H l] 116 | 88.9 | 107 1 129 | 89.0 | 107 1 142 | 89.1 | 108 11 151 89.6 |) 107 1y } 174 [89.8 [108 1202 13 1202 | 89.1 228 | 89.1 110 111 | | 1yyt{ 253 89.2 yur t | 147 279 1 331 189.2 111 89.2 111 | 2 164 119 92.9 262 97.6 |333 i 185 93 4 120 | 1 i | | 288 2 206 121 93.4 | 2681 4| | 2 228 122 93.5 | | | ! 5'405 98.6124 bias | 2 238 93.9 | 120 | | 98.0 6 | t , | 2 267 938 | 122 l | if 1 | | aoe 2 1 308 1 9RP + 123 ; i | | a | | | 2 294 [947 118 407 mye | 98.3 | 4 | 12 330 94.8 119 3 199 96.0 120 4 | 3 227 96.1 122 4 f] . : a 3 244 964 121 4 \ 1 233 97.5 : 120 122 97.7 97.7 i 123 Ay? 288 98.1 125 t ... $7 305 333 i 98.5 t 123 et 98 124 : 268 96.5 { { 3 291 96.6 { 3 322 96.6 | ' 122 4 | 315. i 97.8 ! : 123 | 4 340 | 97.7 5 | ! 12 4 344 ' | en rs 124 125 sea ' 5 362 \ % | 376 toes 98.5 125 | t 98.6124 122 98.7 5'405 5'405 5'405 125 | | 5'405 : | | 3%" 1-330 | 97.0 : H 34" 120 } 44" | 39h | | | { 19g [aver 5 429 98.0 123 | 6 425 6" root 444 198.8 i i 1 as2 ] pase 5124 126 407 | 97.0 3 123 5 441 122 | a i 525 198.8 127 5328 98.5 125 6 \1 355 96.7 125 . se! ga! 384 | 98.8 127 ' : | 420sao! 98.9 90 129 Jot 1 | , : 1 6 1 456 1 98.9 | 130 [er | 49898.9 49898.9 132 [| i [6 564 99.0 135 | | : [6 614 99.0 138 o 168 1688 99.0 | 139 i! | | | |97.0 || f21A" 366 94.8 | | 450 | | 99.1 141 2%" 401 [94.9 | | | | | 1 | | 2 472 [oag 119 120 v2 3 450 i UA 97.1 124 5 97.1 1 125 | 8 4 siz 97.5 120 3 484 | 98.3 123 | 6 90.3, 123 6 613 esa} 125] 6 584 ae 198.9 | 128 46 636 98.9 1129 16 j zao {90.9 | 13h }6 740 99.0 140 i t 810 | i 925, 99.1 , , 149 - - | if ty Recommended Thickness Heat Loss Btu ft./hr Insulation Efficiency Surface Temperature 42 012 0762 OS ea ee . om nr an e s ve - aay <- w - erre e esign data mmended thickness of Kaylo pipe insulation PROCESS INDUSTRY Figures are based on ambient still air at 80 F -- . 280F ene mawecee ture ture 200F ize THL THL E wSu " " " " 32.5 76.1 38.9 76.7 40.8 80.2 cece ST T 106 110 " 107 480F t 680F meee T emer ecestemenemm 400F 600F : 1 oO T HL E ST T HLE HLE ST . 880F | | 1080F 1280F ene --- nn 800F 1000F 1200F EST HL EST EST THL THL i ST ' T HL E | ST | 708 82.0 84.5 82.5 89.0 850 130 138 132 1 129 88 1 108 89 1 118 906 129 1 134 136 135 135 2 147 90 145 2 158 936 92.5 137' 835 2 | 179 2 188 942 956 144 2175 150 2 196 139 2 225 95.5 137 1 95.9 142 963 148 t ' \ 1 2 fo 3 3 4 S 6 7 8 9 10 12 14 16 18 20 ro 144 [| 144 96.9 hd 52,0 79.6 113 " 135 2 | 970 52.6 818 110 " 60.B 82.9 111 " | " 69.9 83.5 112 " 82.6 83.7 114 " | | 1 98.2 84.7 134 114 i 84 > i 144 . 1 132 91.6 115 133 86.3 87.2 138 140 1 148 1 91.7 1 169 92.3 152 877 143 1 174 93.4 180 215 87.9 1 146 4 1 88.6 { 147 1% t ; 222 2% + 222 i 930 94 136 2 141 2 143 2 . 93.9 169 204 94.8 : 1 949 136 216 \ 95.6 149 2 234 96.0 136 2 276 96.3 { 2203 : 95.7 { 1 144 ! 2 224 ! 1 241 95.9 1 1 904 149 ; i 3 236 258 i 146 3 ; 279 145 150 97.2 148 ! 140 i ' 2 256 5 969 143 3 | 298 1 97.7 138 3 3 279 972ry 3 97.9 t 142 { , ,, 323 : 974 144 3 98.1 ,, oe | " 120 84.7 : 33417 | " 156 , 982 486 i = 91.9 1 116 830 88.9 116 1 199 Dot 91.4 131 2 2 262 94.7 122 1 232 91.5 133 2 t ' ' 107 1% ? 252 91.9 132 2 297 94.9 332 95.1 be 139 2 318 : ' 96.5 140 2 364 96.6 , i . 142 2405 96.7 144 147 148 3 375 97.6 148 i 380 98.1 140 t 3417 3417 142 oe 393 1 98.4 \ 4 441 96.5 | 1 i ' 4 486 98.6 i | | 98.1 | 1 129 | | ; 2 | | | 98.6 142 | | 581 1 ' i 97.4 (1 iyo 151 89.0 89,1 1 , | 1 280 92.0 133 2 1 : 108 1 307 92.1 134 89.6 1 328 92.4 133 iv ' { | 366 95.2 . 143 t 2 431 96.9 es foo: 4 2| 470 97.0 + 430 j 954 143 * 3 458 147 3456 148 3 495 98.1 143 fo " 98.1 145 " 1 532 98.6 | i 1 576 150 3545 98.2 147 4%": 98.8 145 141 Py | | i e 133 iv 145 ti 97.4 | r 9t 8.4| 98.988.8 . 1 174 89.8 | 134 1149 | | | | | 1 89.1 138 on i 4 1 228 89.1 108 110 111 92.5 1 380 92.5 | i 1 439 92.1 \ 1 496 ; . 92.1 | ee 2 2 4 139 2 496 566 636 95.5 95.3 ) : | : 95.4 145 3 149 3 150 3 | 526 | } 585 97.4 142 | 145 | 655 97.4 H 147 ' 3623 98.2 149 a? 624 98.4 144 4 | 694 1 98.4 145 4/2 po [4s 660 tS 725 98.8 147 150 | 742 98.9 145 ee 636 | . nee I 2 | | | cot | 139 3 725 | 97.5 148 4 139 9.0147 89.2 111 1% 553 + 92.2 1 140 2 589 96.2 | i | | | | | | ry 1 3 794 97.5 149 4 141 | | 608 92.2 2 646 96.2 140 i | | | | 1 1 279 89.2 111 i \ " | + 141 3 819 97.8 141 | i | | \ 331 89.2 111 1 721 92.2 141 2759 96.3 ! \ | | | i 1 | | . 764 98.4 147 in 835 98.5 147 in 876 | 98.5 149 | 5 815 99.0 146 888 99.0147 9.0147 99.0147 1032 | 99.0 | 149 ! i i Recommended Thickness Heat Loss ft./hr Insulation Efficiency Surface Temperature 42 42 012 012 012012 0763 it's the lew reams 39 hat that counts ing to 1200 ym. pips insulatier design data insulation thickness standards ( >fi eos IRON SIZES PIPE fameteres eT IPS cn abe IPS etme mmm oe Ay ee ena multiple layer only cttiteln ie Sh nom pipe size \ 0.0 i O.D. actual | O.D. actual { | | of single layer only nom 1 nom 1 | single or double layer nom 2 nom 2 nom 3 0.0 actual 0.0 actual pipe actual O.D. actual O.D. jactual jactual O.D. jactual jactual 0.0.lectual 0.0.lectual nom 3 nom 4 nom 4 nom 5 O.D. " .84 3/4 " 1 1.05 1.32 1... 1.66 1 1.90 1.00 .90 1.08 .90 1.03 2 { 2.38 1.04 22.88 1.04 3 ! 3.50 1.00 34.00 1.30 4 i 4.50 4 5.00 5 | 5.56 6.63 1.30 1.02 .95 7 7.63 i a 8.63 9 | 9.63 10 | 10.75 11 11.75 12 12.75 14 14.00 15 16 17 18 19 15.00 7 16.00 | 17.00 18.00 | 19.00 j | 20.00 20 21 | | 21.00 22 22.00 23 24 2244..0000 25 26 27 28 29 : 25.00 | 26.00 | 27.00 | 28.00 | 29.00 30 31 32 33 34 | 30.00 31.00 | 32.00 | 33.00 | 34.00 35 36 37 38 39 35.00 36.00 37.00 38.00 39.00 | 2.896.66 | | 2.896 2.88 1.56 5.00 | 2.88 1.46 12.56 | 3.50 1.58 12.15.6 12.15.56 2.66 | 5.56 2.48 3.50 1.66 4.00 1.53 | | | 11.78 11.78 7.66 8.66 3.62 5.25 4.50 | 5.00 2.55 1 12.81 5.56 1.57 1.87 1.55 ( | 6.66 1.80 12.05 | 10.78 | | 8.66 9.66 6.66 1.55 | |14.06 | 12.05 7.66 | 10.78 15.| 105.606 16.09 2.58 5.13 7.66 | 11.78 | 17.00 | 8.66 1.80 1.52 1.45 12.02 ; | 16.| 106.909 5.13 14.03.666 1.52 _ | 1 1.52 4.00 : 2.06 | 4.00 1.96 4.50 12.115.56 5.00 1.94 5.00 2.36 5.56 2.12 6.66 2.37 6.66 12.05 7.66 7.66 8.66 2.30 8.66 2.02 9.66 2.02 10.78 12.02 11.78 12.03 5.00 2.896.66 2.79 1 6.66 6.66 3.39 3.29 3.16 7.66 7.66 7.66 6.66 2.86 6.66 2.98 | 7.66 7.66 3.36 | 8.86 | 6.66 2.62 | 7.66 | 7.66 2.87 : 8.66 2.80 2.55 8.66 8.66 9.66 9.66 2.8610.78 | 9.66 10.78 2.52 11.78 12.81 12.81 14.104.6 06 3.12 3.37 1 3.05 9.66 9.66 3.36 , 10.78 3.11 9.66 3.93 10.78 3.61 110.78 3.86 11.78 3.61 11.78 3.36 111.78 3.88 12.81 3.08 11.78 3.03 12.81 3.59 3.66 12.81 14.06 3.16 15.06 3.16 15.06 3.67 16.09 | 4.18 10.78 4.43 4.11 4.38 12.81 4.13 12.81 4.50 14.104.6 06 4.13 17.00 t 4.68 4.95 4.63 5.00 4.75 112.81 12.81 14.06 114.06 5.20 5.57 12.81 14.06 14.06 5.50 15.06 5.25 15.06 5.00 15.06 4.72 15.06 4.68 4.63 4.63 118.00 5.51 5.23 16.09 16.09 17.00 5.13 18.00 19.00 4.63 19.00 5.13 20.00 ' 16.09 | 18.| 108.000 20.00 | 2.66 117.00 18.00 12.16 14.06 15.06 3.17 3.63 4.06 19.00 4.56 5.06 21.00 | | ,| 17.00 : 1.53 12.81 2.09 115.06 2.61 16.09 3.06 3.56 3.55 19.00 20.200.000 4.54 121.00 4.55 , 22.00 1.59 | | 17.00 14.06 16.09 2.55 3.05 18.00 4.54 122.00 4.55 23.00 | 1.58 15.06 12.09 3.05 19.00 3.55 | 20.00 4.05 21.00 4.92 24.00 | | 18.108.000 | 1.59 117.00 3.42 .00 3.92 , 22.00 4.42 23.00 | 116.09 | 20.00 2.42 19.00 2.92 1.92 1.42 | | 4.92 24.00 y 17.00 1.92 18.00 2.92 21.00 3.42 22.00 1 3.92 23.00 4.41 25.00 4.91 26.00 19.00 23.00 | 2.410 2.4120.00 | | 25.00 1.42 18.00 1.92 2.4120.00 21.00 2.91 22.00 3.41 3.91 24.00 25.00 4.41 4.41 26.00 14.91 27.00 | | 1.41 19.00 1.91 20.00 2.41 2.91 23.00 3.41 124.00 3.91 28.20 8.0 00 , | 21.00 | |} | } || | 1.41 20.00 1.91 2.41 i 22.00 2.41 i 23.00 2.91 24.00 3.41 25.00 26.00 3.91 3.91 26.00 27.00 4.41 4.41 27.00 28.00 4.91 29.00 1.41 | | | 21.00 1.91 22.00 23.00 2.41 24.00 2.91 25.00 3.41 | | | , 1 1.41 - 22.00 1.91 28.00 4.41 29.00 4.91 30.00 | 1 26.00 |3.91 24.00 | 1.91 2.41 25.00 2.91 3.41 27.00 28.00 3.89 29.00 4.41 30.00 4.91 31.00 1.41 23.00 1 | : 26.20 6.0 00 2.91 27.00 3.41 4.41 31.00 14.91 32.00 25.00 | | | 14.91 | : | 24.00 29.00 1.91 3.39 3.89 30.00 33.00 | | | 1.41 1.91 2.41 27.00 2.91 28.00 30.00 3.89 31.00 4.41 32.00 4.91 | } | | 26.00 25.00 1.91 2.41 | 28.00 2.91 29.00 3.39 3.89 32.00 4.41 33.00 5.00 34.00 | 1.41 | | | | 27.00 1.41 126.00 2.91 30.00 3.39 31.00 ; | 29.00 1.91 28.00 2.41 | | | | | | 27.00 1.41 1 q 3.44 32.00 3.96 33.00 4.48 34.00 5.00 35.00 36.00 | 30.300.000 | | $ | | | : 1.46 28.00 1.98 29.00 3.02 3.02 31.00 132.00 3.44 33.00 3.96 34.00 4.48 4.48 35.00 36.00 5.00 5.00 37.00 30.00 | | | | } | | || ;; 32.302.000 1.46 29.00 1.98 31.301.0 00 3.02 33.00 3.44 34.00 3.96 35.00 36.00 4.48 37.00 5.00 38.00 | { | | 1.46 30.00 1.98 31.00 3.02 34.00 3.44 35.00 3.96 5.00 39.00 | | | ; 1.46 31.00 1.98 32.00 33.303.0 00 3.44 36.00 3.96 37.00 4.48 138.00 | | | | 2.50 34.00 3.02 35.00 33.00 | | | | | | 32.00 1.98 3.44 37.00 3.96 38.00 4.48 39.00 5.00 5.00 40.00 41.00 i | | | | 1.46 33.00 1.98 34.00 2.50 35.00 3.02 36.00 3.44 38.00 3.96 39.00 4.48 40.00 | | || || | | | 1.46 34.00 1.98 35.00 2.50 36.00 3.02 3.02 37.00 38.00 3.44 39.00 3.98 40.00 4.48 41.00 5.00 5.00 42.00 43.00 | | | | | | | | 42.00 1.46 135.00 1.98 36.00 2.50 37.00 | 3.02 39.00 3.48 40.00 3.98 41.00 4.48 5.00 44.00 | | | | | | | 38.00 1.46 136.00 1.98 37.00 2.50 3.02 140.00 3.48 41.00 3.98 42.00 4.48 43.00 } | 44.00 } | | | 1.46 37.00 1.98 88.00 2.50 39.00 142.00 3.98 43.00 4.48 5.00 45.00 46.00 } 1.46 38.00 1.98 39.00 2.50 140.00 3.02 41.00 3.48 3.48 43.00 3.98 44.00 4.48 45.00 5.00 | | || 4|.0 | | | | | 1.46 39.00 1.98 0.00 2.50 141.00 42.00 3.02 3.02 142.00 43.00 3.48 44.00 3.98 45.00 4.48 46.00 5.00 5.00 47.00 48.00 | | | | | | | 2.00 | | 47.00 | 1.46 140.00 1.98 1.00 2.50 43.00 3.02 44.00 3.48 45.00 3.98 46.00 47.00 4.48 4.48 48.00 5.00 49.00 1.46 41.00 1.98 2.50 45.00 3.48 3.98 \ 42.00 3.00 | j j 3.02 | | 46.00 1.46 1.98 2.50 44.00 42 012 0764 ao see Kcylo pipe insulation wey data data ee design ee ae data insulation insulation insulation standards thickness standards thickness Ly Oe of e " nom tube size COPPER TUBINGCT Le single t la ee te cease aan Bt ree eames WHT BH Oe layer nom * nom 1 actual 0.0 actual O.D. | " % 1.18 2.88 1.49 3.50 * 1.11 | 2.88 1.42 3.50 1.05 ' | 2.88 1.61 4.00 a .99 | 88 1.55 4.00 rn 4 | Pn % l % : % if 1... 1 2 3 1.17 - 1.05 1.17 .91 { .91 | .91 1 3.50 3.50 4.00 4.00 4.50 5.00 1.42 1.55 1.42 1.41 1.45 1.73 4.00 4.50 4.50 5.00 5.56 6.66 insulation efficiencies we a - nee eee sen a AOS 701234756709 701234756709 701234756709 701234756709 me init 701234756709 80 85 i 7 9 3 90 1 | 3 4 95 4 ? r ] 100 HAT 200 300 NH c Saxe x Sane N PREAKNESS,I N NOENCON aS NINA) KTTTRRSN RRS. SSIS 5 RANUSEARUNE RE i on BRNRaN SNNn ISIE ISSA ARAL 400 RTPNSRNESRS SSNS SRS RD NU NINN SSSR SS AANA AAS RSS RPT RSRNSRNSENIS 00 q N. SSANSEAN NY 600 EYONONO AK SS RASS ARAL AA ATLA N N Q 0000002002 0 0 0 20 2 0000002002 700 _0 hI KEY CURVES 114122334454114122334454CURVES 302224 VANANA 2 5516 7 ! 10'12 o 10 . 10'10 12/11/13/17 7 10 12:13 114 14 A h NNNIN AA 10 11 12 14 14 15 15 12/11/13/17 114 34 15.16 15.16 17.17 15.16 15 14 16 17.17 18 17.16 17:17 19 15 15 16 17 17 7:18 20 20 KONOVO __ oe 15 18.17 17 18 18 19:20 20120 20 16 17 18 18 19 19 20'20 23/21/223/121/21 12 15 15.15 17'17 17 18 19 19 20 20 20 20.21 21.21 12:12 15 35 17,17 19'19 19'19 20 20'20 21 21:21 21-21122 0 0 0 20 2 0 0 0 20 2 0000002002 000202 0000002002 RAR AA AARAATARARAA RAB KY INS vy \ SA NAIAUCAVATLD \ V\ TAWA VAAAY \ N \\ Wetik \ \ q WY 4 \ fiflfi fl 19 19.20 20 20 21 21 22 27'22 22 22'22 42 aye 100 " 100 200 300 400 500 1000 110 1200 012 0765 41 that counts . 5 a BE ol x 7 re | - as y ; 5alte) ping ping 1200 a Ae lo insulation O Latron mse pre Kaylo th wt piping insulation insulation for 3 specification for insulation insulation piping with Kaylo piping insulation 1: Insulating materials Ali All heated pipes shall insulated insulated in in following following table Kaylo insulated Fiberglas Corporation to thickness thickness thickness noted on drawings or as shown noted drawings shown - em TABLE TABLE RECOMMENDED INSULATION THICKNESS F according to use. Recommended Thicknesses vary Recommended Thickness Table 37-39 for Complete See pages 2: Application surfaces butting adjoining sec together shall be applied over clean dry butting butting adjoining_sec- tions firmly Insulation on pipes under 12 diameter furnished factory applied on canvas canvas neatly and be secured with factory not greater than in place Insulation 18 centers not Insulation all outdoor piping shall wired wired in place diameter and Where place place gauge gauge annealed annealed 12 than centers centers insulation insulation insulation applied annealed wire on nsohalglrebaeterwired place place without jacket layer layer layer shall applied with first layer with all joints staggered fabricated layer flanges flanges valves with mitered segments equal in thickness shall be insulated adjoining adjoining Fittings segments on cement pipe insulation insulated the insulation the smaller smaller may with insulating insulated pipe pipe size be equal thickness thickness 3 size of 3" and smaller may furnished place 3: Indoor under abrasion abrasion mechanical mechanical re- re- quires finish addition to factory furnished subject canvas bands Piping over 12 12 shall finished finished with 6 place diameter diameter located outdoors shall finished with pasted all all Piping located Jackets Jackets shall wired roofing felt jacket witohn not not 16 ga copper wire lapped not thoarnbanded on centers centers with Other Other galvanized suitable weatherproof weatherproof centers such metal metal asphalt plastic galvanized applied applied coating according weatherproof weatherproof jackets jackets specifications specifications plastic may applied jacket manufacturers manufacturers specifications according specifications Insulation Insulation on flanges valves ... coat coat finish- finish- finish- to maximum maximum dry weight weight added harder harder harder harder desired Insulation Insulation indoors shall further further finished with neatly neatly Insulation Insulation located located shall be further with canvas pasted place located indoors insulation insulation Insulation All the fitting asphalt insulation insulation fabric covered covered with with sufficient thickness reinforced with open mesh shall be troweled shall shall applied sufficient give " dry coat troweled troweled neatly neatly thickness adjacent pipe shall in lapped over jacket on the adjacent the adjacent pipe. on be applied recommended the written specification specification is recommended The responsibility design engineer meet specific job specific job job requirements requirements is responsibility as and responsibility of the design engrneer specific may be made at the discretion requirements. 012 0766 0766 _ PLAINTIFF'S EXHIBIT 210.09 210.09 CORNING |, FIBERGLAS A CH 7 31.0 NO FUE 6.1 6.1 CORNING FIBERGLAS FIBERGLAS FIBERGLAS Fiberglas k .25 Insulation A .32 Insulatio 8n .34 100 mean temp Insulation .41 Insulation D = km.52 If you specify buy or use industrial insulations we believe you will find this Fiberglas Manual a ready source of ideas for saving money and achieving efficiency We do not claim that Fiberglas insulations are your best choice for every industrial use But within their fields of application covers almost every industrial these carefully engineered products offer you extra values because of their unique combination of properties Here are some of the benefits you can expect ... T M. Corning Fiberglas Corp. greater efficiency with equal thicknesses Because the maze of fine Fiberglas fibers entraps countless tiny air cells Fiberglas insulations have exceptionally low k values Result . when equal thicknesses are specified Fiberglas producta give superior heat control as shown by the typical illustration above This feature can be of value when rigid control of heat in process equipment or maximum effective heat control is desired 3.25 1.00 438 2.12 1.63 lesser thicknesses for equal efficiency The low k value of Fiberglas insulations means that where a certain insulating efficiency is desired it can be achieved with lesser thicknesses of Fiberglas insulation as the illustration of a typical condition above showa Thus maximum economy consistent with insulating requirements is often possible using Fiberglas insulations | " fewer maintenance problems v an Durable inorganic Fiberglas insulations offer long life to all installations They won't rot shrink warp or buckle They are light in weight ... reducing danger of sagging problems will not corrode or accelerate corrosion of metal surfaces and because of their resilient nature stand up well in service - wide temperature range Fiberglas offers the most complete line of industrial insulations in the industry Properly specified and applied these materials offer superior performance at temperatures from zero to 1800 F. a solution for every industrial Insulation problem There is a Fiberglas insulation to specifically meet almost every industrial insulation need in their temperature range The wide selection of types sizes and densities permits the designer to obtain a desirable combination of cost performance appearance and any other specific properties desired lower application costs The light weight and workability of Fiberglas insulations permits easy handling and fast inexpensive application All products are exceptionally easy to cut and fit Factory applied finishes cut down the need for job site application of jackets finishes etc. Use index 4-5 Fiberglas pipe insulations standard pipe insulation 9-18 low pressure pipe insulation 19-22 dual temperature pipe insulation 23-30 low temperature pipe insulation 31-40 Kaylo pipe insulation 41-48 Kayla pipe insulation 49-52 blanket type pipe insulation 53-56 Aerowrap pipe insulation 57-60 Fiberglas duct insulations PF duct insulation 63-66 coated duct insulation 67-70 vapor seal duct insulation 71-74 Alexible duct insulation 75-76 fiexible duct insulation 77-78 flexible duct liner 79-80 Fiberglas equipment insulations PF insulation 83-86 block insulation 87-88 metal mesh blankets 89-92 Kay oblock insulation 93-94 Kaylo block insulation 95-96 Fiberglas cold storage insulations PF insulation for wall construction 99-104 AE board for hot dip application 105-108 AE board for floors 109-112 roof insulation 113-114 Accessory Materials for industrial application 115-118 Engineering data 120-127 Ordering information 128 Pricing information 129 Terms of sale 130 Branch office listing 132 . . ec vee . guide . . : . . se? ti +e ae tk = : i eal ducts dn guide - "eq . . tad index ee o. y index indexindex indeexe e. a7 yn we, 2 a . CORNING FIBERGLAS FIBERGLAS FIBERGLAS FIBERGLAS - storage cold storage ala application HOT PIPING Hot Water and LP Steam Steam High Pressure Steam High Pressure Steam Super Temperature Steam Traced and Nested Lines Traced and Nested Lines Hot Maintenance COLD PIPING Cold Water temperature Chilled and Ice Water Brine and Heavy Brine Refrigerants Special Process HEAT VENT & AIR COND DUCTS operating temp range ~~ up to 250 up to 400 up to 1000 up to 1200 s 1200 to 1800 F. up to 400 up to 1000 up to 400 down to 50 35 to 200 down to 35 34 to F 1 -1 to -60 -61 to 120 j < ! ; t ; : = Hot Air Systems Concealed Rectangular Concealed Round Exposed Rectangular Exposed Round Dual or Cold Air Systems Concealed Rectangular Concealed Round Exposed Rectangular Exposed Round Interior Application thermal and acoustical Hot and Cold Air Rectangular { up to 250 up to 250 up to 250 up to 250 up to 250 up to 250 down to 35 down to 35 down to 35 down to 35 down to 35 up to 250 down to 35 i H t < : { : : , Hot and Cold Air Round down to 35 up to 250 down to 35 NOTE For design data on ducts used outdoors see the Industrial product sheet concerned ore HOT EQUIPMENT Breachings Condensers Driers Ducts process Evaporators Heat Exchangers Hydrators Ovens Stills Tanks storage Turbines . | upup to 400. { 1000 up to up to 1200 F 1200 to 1800 Vessels processing COLD EQUIPMENT Brine Tanks Chillers Compressors Heat Exchangers t Refrigerant Tanks Tanks Storage Vessels storage COLD STORAGE ROOMS Cooler and Chiller Ceiling Cooler and Chiller Wall Cooler and Chiller Floor Freezer and Sharp Freezer Roof Freezer and Sharp Freezer Ceiling Freezer and Sharp Freezer Wall Freezer and Sharp Freezer Floor 50 to -120 as 70 to 35 70 to 35 35 70 to 34 60 60 34 to 34 to 60 60 34 to 60 { & * { : i i < f . recommended Insulation ) Low Pressure Pipe Insulation Standard Pipe Insulation Blanket Pipe Insulation Kaylo Pipe Insulation Keylo Pipe Insulation Aerowrap Pipe Insulation Blanket Pipe Insulation Aerowrap Pipe Insulation Low Pressure Pipe Insulation Temp Pipe Insulation White Temp Pipe Insulation White Temp Pipe Insulation Black Flexible Duct Insulation PF Duct Insulation Hexible Duct Insulation & PF Duct Insulation < Coated Duct Insulation Flexible Duct Insulation Faced Flexible Duct Insulation Vapor Seal Duct Insulation Faced Flexible Duct Insulation Vapor Seal Duct Insulation Faced Flexible Duct Insulation Coated Duct Insulation Flexible Duct Liner Flexible Duct Liner type Molded Molded Flexible Molded Molded Flexible Flexible Flexible Molded Molded Rigid Molded Molded Rigid Mult.Layer Mult.Layer Flexible Semi Flexible Rigid Semi Flexible Flexible Rigid Flexible Semi Flexible Semi Flexible Flexible data poges 19-21 9-17 53-55 41-47 49-51 57-59 53-55 57-59 19-21 23-29 23-29 31.39 guide index specifications page 22 18 56 48 52 60 56 60 228 228 30 40 - Ow 75.76 63-65 75-76 63-65 67-69 75-76 77-78 71-73 77-78 71-73 77-78 67-69 79-80 79-80 R3K3RK R3K3RK R3K3RK R3K3RK R3K3RK 76 RKRKR RKRKR RKRKR RKRKR 78 70 80 80 PF Insulation w4y, Block Insulation - Metal Blankets Kaylo Block Insulation Kaylo Block Insulation PF Insulation AE Board AE Board . AE Board AE Board and Roof Insulation AE Board and PF Insulation Board PF Insulation Board and AE Board 3 AE Board Board Rigid Block Rigid Flexible Block Rigid Block Board Rigid Rigid Rigid Rigid Rigid Rigid Rigid the 83-85 86 87-88 20 89-91 92 93-94 203 95-96 203 83-85 86 105-107 105-107 109-111 109-111 and 113 105-107 99-103 and 105-107 109-111 108 108 112 112 and 114 108 104 and 108 112 5 industrial insulations ... manufactured to exacting standards constantly improved by practical research backed by years of industrial experience industrial distributor are financially sound and competently managed backed by years of application experience schooled in Fiberglas product application capable of handling complete contracts located to serve the entire country j mx FRANCHISE FRANCHISE ro = ns Tas etal L APPO CoI riN ngT PagM ina CE arpaN tionT here by appoints for compley at an Apps Pintal Or^...m Contractor of Pergies Ladestral Lamistama Products for the aru 1. AREA SERVED The Aprenent applim to the arta haru~ on the map stacked barste as Exhibit A. and made a part haru~ = you can entrust your insulation a ied problems to franchised Fiberglas ai i] contractors with complete -3 4 =< confidence in the best job with the ed os wal > as 2 x best materials at the best price rey aes a 2 costa < eta wae ay bee es vray asod ~22 3 shee esl tet ee EaRk 88 twig tet ndaenes By 7g ans CORNING 57.0 FIBERGLAS 57.057.0 . NO NO FILE FILE FILE A.LA insulations insulatons pipe FIBERGLAS IN1.C5 July 1956 high temperature insulation for indoor and outdoor piping up to 1200 operating temperature ----- Ow _ Kaylo pipe insulation 2d Kaylo Pipe Insulation a white rigid hydrous calcium silicate heat insulation manufactured by Illinois Glass Company and distributed nationally by Corning Fiberglas Corporation effectively insulates indoor and outdoor piping up to 1200 F. This thoroughly tested and proven material contains the physical properties most desired for efficient durable insulation work Kaylo Pipe Insulation's thermal effectiveness high strength and moisture resistance are unattained by most other insulating materials A chemically reacted material Kaylo Pipe Insulation contains no added binder For mechanical effects a small amount of asbestos fiber is included at the time of manufacture jackets canvas Sectional Pipe Insulation includes standard canvas jackets at no additional charge on thicknesses up to and including 2Standard canvas is available on segmental forms at a slight additional cost Bands are available for use with this product at slight additional charge and will be furnished on request 6 oz and 8 oz canvas jackets are available for all types sizes and thicknesses of Kaylo Pipe and Tube Insulation at an additional charge These jackets are factory applied on Sectional Pipe and Tube Insulation On segmental forms they are furnished but not adhered offers high efficiency the most efficient insulations for temperatures up to 1200 Low k results from extremely small and numerous insulating air spaces simplified dimensional standards are designed to permit nesting of one size over another to produce greater thicknesses than available in single layer or to produce broken joint concept water resistance Pipe Insulation retains an appreciable percentage of its strength even after complete saturation in water After a cycle of soaking and drying it returns to its original thermal efficiency and strength with no shrinkage or warping high strength flexural strength compressive strength and resistance to abrasion far above normal requirements for beat insulation greatly reduce installation and service breakage easy fabrication tools of the trade sufficient for all cutting sawing or scoring irritating to the skin and toxic Offers pleasant handling characteristics long Remains strong and efficient over the years Dimensionally stable with little shrinkage Has superior life char- acteristics over other types of high temperature insulations thickness Pipe Insulation is available in thicknesses from to de pending upon pipe size Kaylo Tube Insula- tion is available in thicknesses of " and 1 versatility Performs efficiently at temperatures through the hot water and low pressure steam range in addition to tem- peratures in the superheated steam range One high temperature material to do the job usually requiring combinations of two different insulating materials pipe Kaylo Pipe Insulation is available to fit pipe from " to 39 in diameter Kaylo Tube Insulation will fit copper tubing from to 3in diameter forms Pipe Insulation is available in sectional or multisegmental form depending upon pipe size All insulation is furnished in 3 sections Kaylo Pipe Insulation is designed for temperatures up to 1200 and is not recommended when operating temperatures of piping exceed this limit T M. Illinois Glass Co it's it's it's it's the the the ti} low ration flietl C ls 41 physical properties density approximat ely 11 lb. per cu ft : flexural strength .. ..5 50 lb. p0 er sq in compressive strength of % deformation nk before .15.150 0 .150 lb. per sq in after heaft or i 24 n hougrs at 750 2... eee 144 lb. per sq in . at 1000 123 lb. per sq in j afterab t o 1d2 ifo0 nr g 20 4 hop urs a 117 lb. pr ar sq in after heating for loss in weight 24 hours al 750 5.5 4 at : eee ee so tsenece at at 1000 20... 1200 te 28. becceeeee Ee ceeee enna 7.9 9.8 after boiling for 24 hours after drying .... 9.8 resistance te abrasion - o in adn} conventional tumbling weigwh eigt ht after 10 before heating .. te eeeeeeas tee eeeeeces after for 24 hours heating 22 at at at 750 eeeeeee seacessces 1000 37 0.08. tt 1200 57 659 7 0... ee eeceeee cevesae dimensional stability Einear shrinkage after heaft or i 24 n houg rs e e at 08 at 1000 ec ceecceeences 0.9 at 1200 cease eee sooee 1.5 oe slongation after saturation max . eens . .0.01 Sem moisture adsorption volume after 6 hours exposure in otmosphere of 120 and 90 relative hum.iodfit..y 0.9 - thermal conductivity oe at rfCe Thevewsl Comductiviny K? Saf oy &ePf, te, come | | fF] sce aw HIDUCTIVITY N / seb eat LT |nor ee a e a a ek ae) irregularly ap- Kayla Pipe Insulation presents a superior final appearance when plied to a variety of high temperature vessels design data | The following data is presented to aid in the design of Kaylo Pipe Insulation modified to meet specific needs Recommendations are generalized and should be modified to meet local conditions and job requirements recommended thicknesses Economical thicknesses of insulation vary to a substantial degree in different industries principally because of 1 Cost of fuel and operation time 2 Fixed charges or anticipated life of installation Because these two factors vary greatly by industry a single table of recommended thickness would be only an approximation To approach more closely a true Economical Thickness the recommended thickness data on the following three pages is presented for three major industry groups 1 Commercial and Industrial 2 Power and Utility 3 Process and Industries ce oe ee Ae 1-523a Insulation Block Pipe Covering and Cement Thermal Calcium Silicate For Temperatures up to 1200 1-2781B Insviation Pipe Covering Thermal ae , Kayla Pipe Insulation ap | plies easily and quickly with - standard applica- j tion methods 4 exceptions Economical Thickness recommendations may not apply where insulation is applied for process temperature control personnel protection or fire protection for specific areas Refer to Kaylo Performance Data Book for insulation design for such con- ditions See pages 43-45 Insulation thickness standards This table presents reference data for information on the actual thicknesses according to the simplified Dimensional Standard system See pages 46 47 E Insulation efficiencies of This table and graph enable making the determination thermal efficiencies for thicknesses from -5 for pipe to air temperatures from 100 to 1200 See page 47 piping piping piping to 1200 a er design * design data thickness pipe insulation insulation recommended thickness of Kaylo pipe insulation COMMERCIAL AND INDUSTRIAL DESIGN Figures are based on ambient still air at 80 ) pipe temp temperature difference pipe size T 280F 480F 200F et 400F . . HL E ST T HL E ST T 680F 600F HL E 6a oa ST 32.5 76.1 106 2 e. 3/4 38.9 76.7 110 " a] . 1 40.8 80.2 107 " 38 86.8 105 2 73.3 91.1 107 59 87.8 108 2 81.8 91.9 109 64 89.2 107 3 86.0 93.1 107 ) 14 1 2 1 1 1 38.0 42.6 48.3 85.1 85.3 86.4 99 101 101 2 " 2 67 73.9 79.5 91.0 91.2 92.3 105 107 106 3 3 3 93.0 97.8 108.0 94.1 94.5 95.1 106 107 108 2 3 + 1 1 1 50.0 63.7 76.8 88.2 87.5 88.0 99 103 105 " 2 2 94 102 120 92.4 93.2 93.7 110 109 110 3 4 4 115.0 125.0 145.0 95.6 96.1 96.4 107 107 109 7 y i 8 9 . 10 1 1 1 91.4 107 116 88.3 88.4 88.9 106 107 107 1 1 1 129 142 151 89.0 89.1 89.6 107 108 107 124 141 152 167 181 200 94.6 94.8 95.1 106 108 107 " 4 4 164.0 172.0 188.0 967 97.1 97.2 109 107 -108 -108 95.2 95.4 95.4 108 109 110 4 4 5 206.0 222.0 226.0 97.3 97.4 97.6 109 110 108 12 1 174 89.8 108 3 206 95.9 14 1 202 89.1 110 3 227 95.9 16 " 182 91.3 104 3 253 96.0 . a 3 % 1 18 2 202 91.4 104 3 280 96.0 22 " 222 91.4 104 3 305 96.1 " 24 " 262 91.5 105 3 358 96.1 Recommended Thickness Heat Lou Lin ft./hr ft./hr Insulation Efficiency Surface Temperature it's the low 107 108 108 in ,,n 5 256 280 293 109 109 110 5 5 5 321 350 400 97.7 977 97.9 109 110 108 97.9 97.9 98.0 109 110 110 Pell.) REISE 43 piping to 1200 F Kaylo pipe insulation datdaata design I data . design design design recommended thickness of Kaylo pipe insulation POWER AND UTILITY INDUSTRIES Figures are based on ambient still air at 80 F pipe temp 280F 480F | 680F ce cee er ee PORT OI * T YTTINTON Mrtnys SE TUF Be AEE Ty OOF ne | eemeat 880F " tah tala Nae et hs ne Baa difference . 3 eden tne ee tee Ce ee i Babel teen, OOF ot, tee 800F arr pipepipe size THE THE E ST THE THE EST EST THU THU E ST THL THL E STT . 1080F = Tes Eanes 1280F sn | % - " 32.5 76.1 106 11 58.4 85.2 113 2 83.6 89.8 118 2 104 93.0 116 i . . 1 1 ' 96.5 389 767 110 1 67.4 86.0 117 2 95.0 90.6 122 21 116 93.7 120 3 . 143 95.3 122 3 170 96.5 123 . . i iyHi * 40,8 80.2 107 1 73.4 877 116 2 103 91.8 121 2 132 942 124 3 155 95.8 122 3 193 96.8 125 % 1 . ' 1 ' 52.0 79.6 113 IW" 82.2 88.9 117 2 108 93.1 117 3 140 95.1 122 3 172 96.6 124 4 203 97.4 125 ih 52.6 81.8 110 1 92.3 69.0 121 2 119 93.3 121 3 158 95.3 125 3 178 96.8 122 4 206 97.6 121 2 ~ 2 3 4 5 6 7 8 9 10 12 14 16 18 24 = 1 60.8 82.9 111 1 105 89.9 122 2 128 94.2 119 3 165 95.9 124 4 190 97.2 121 4 228 97.9 125 ' ' n " 69.9 83.5 112 11 108 91.3 117 28 151 94.3 124 164 96.1 122 4 204 97.5 121 ' 245 98.1 125 82.6 837 114 * 98.2 84.7 114 2 " 20 847 116 2 " 156 83.0 122 2 116 92.2 115 2 164 94.9 123 3 190 96.8 121 4 222 973 $* 263 98.3 124 139 927 118 3 1 172 95.8 118 3 222 97.0 124 4 252 98.0 123 5 295 98.4 125 164 92.9 185 93.2 119 120 ia ... 199 227 ' 96.0 120 4 96.1 122 ** 233 J 97.5 120 4288 981 125 5... 328 98.5 125 262 97.6 122 5 305 98.5 123 6 355 987 125 1 116 1 129 1 142 14% 151 1 174 , 1 202 1 228 11 253 19 279 1 331 889 9.0 89.1 89.6 89.8 89.1 89.1 69.2 89.2 89.2 107 107 108 107 108 110 1112 . 1212 111 141 2 206 . 2 228 .... 230 .... 2 267 ; 1 2 308 re 294 i 1112 330 1 : 23 I ' 366 : 2 401 : 2 472 3 93.4 = : 121 { i 93.5 122 3 93.9 120 3 ' 93.4 122 244 96.4 1 . 268 96.5 121 +=? 122 4 288 97.7 123 5 { 315 97.8 124 | 5 333 362 291 : 322 : 96.6 . 96,6 123 . 125 4 340 : . 4 344 : : 977125 ' 94.0 | 122 ; 5376 . 51 405 985 98.5 986 983 124 125 6 124 6 125 6 . 384 988 420 98.9 436 98.9 498 98.9 . 93.9 947 : 94.8 94.8 94.9 94.9 123 118 ' 119 ; ; ... 120 121 foo: 3330 3 366 3"407 { 450 3 3 494 ! ta 517 { t 97.0 120 2 : : 97.0 122,4 123 124 ' 97.1 125 97.5 120 4 i { .98.1 123 | 46 122,4 429 98.1 1 125 |6* i in i 441 983 122 6 fo: 1 15 484 983 123 :: 15 ' 5 28 98.3 t 123 | : ' 15 613 984 125 14" 444 482 . 525 : 584 636 740 98.8 on 124 564 98.8 . 4 126 127 - ... ) i 6 614 688 i . 989 989 128 6 i 129 6 ^' 740 810 . 98.9 131 o? { 925 99.0 99.0 99.0 99.0 99.1 99.1 127 129 130 132 135 138 139 140 141 143 Recommended Thickness Hear Loss Lin ft./hr kusulation Efficiency Surface Temperature 44 piping to IZUU IZUU Keyle pipe insulation 4b design data design cece design design data ones recommended thickness thickness of Kaylo pipe pipe insulation insulation insulation PROCESS INDUSTRY Figures are bosed on ambient still air at 80 F Ow pipe temp ro ees Sake temperature : temdifpfereencre ature temperature . pipa size THL X I" - * j 280F 480F ers 200F & tL basen Sooner . 400F 2: ae. _s Shas H 680F ee eae nid 600F a to seme oe ~ THL E STT STT HL EST EST T HLE HLE acee 880F weer ees wes 800F . ST THL THL E ST 1080F ~ mee 1000F 1280F ter em ee 1200F . - T HL EST EST THL THL E ST 32.5 76.1 38.9 787 40.8 80.2 106 110 107 * ... 1 70.6 82.0 84.5 82.5 89.0 85.0 t 130 1 129 H 138 108 88.5 . 89.3 132 1 118 90.6 129 1 134 1 136 " 135 90.5 92.5 135 . 147 93.5 145 2 158 137 2 179 136 2 188 93.6 94.2 95.6 144 150 139 21 175 95.5 2 196 95.9 2 225 96.3 137 142 141 114 1 2 * 52.0 79.6 113 " 114 84.6 144 13 132 '91 136 2 173 93.9 144 2 203 957 144 3 52.6 81.8 110 115 86.3 138 14 148 91.7 141 169 94.8 135 2 224 95.9 149 = 60.8 82.9 111 ... 133 872 140 % 169 92.3 2 204 94.9 144 2 241 96.4 46 .. 236 96.9 14 259 97.0 15 279 97,2 14 2 w 4 1 69.9 83.5 112 ... 152 873 143 11 174 93.4 136 216 95.6 140 2 256 96.9 143 ... 298 977 14 82.6 83.7 114 180 87.9 146 13 222 93.0 149 2 234 96.0 138 3 279 97.2 142 3 321 97.9 14 98.2 84.7 114 ' 215 88,6 147 2 222 94.5 136 2 276 96.3 142 97.4 144 3 375 98.1 14 ab . aa S " 120 847 1 91.4 131 2 262 947 139 12 318 96.5 144 3 375 97.6 148 4 393 98.4 14 6 " 156 83.0 122 1H 91.5 133 = 297 94.9 140 2 364 96.6 147 3 380 98.1 140 4 441 98.5 14 ? 11 116 8.9 107 | 1 252 91.9 132 2 332 95.1 142 2 405 967 148 % 417 982 142 4% 486 98.6 14 : e 1 129 89.0 107 11 280 92.0 133 2 366 95.2 143 12 431 96.9 147 3 456 98.1 143 4 532 98.6 14 9 19 142 89.1 108 14 307 92.1 134 384 95.5 141 2 470 97.0 148 % 495 98.1 145 4 576 926 15 10 13 151 89.6 107 1 328 92.4 133 430 95.4 143 3 458 97.4 141 31 545 98,2 147 % 581 98.8 14 12 14 16 10 20 24 | % : 174 89.6 108 18 t 380 92.5 134 i . 496 95.5 145 3 t 526 97.4 142 3 623 98.2 149 4 660 98.8 14 | 1 202 14 228 | { ' 1 253 89.1 110 14 439 92.1 89.1 1 496 Ly 92.1 89.2 { | = H 553 922 2 138 2 139 1 586 95.3 636 95.4 . 140 21 589 t 96.2 149 13 150 3 { 13 139 : 585 97.4 145 4 624 98.4 144 4 725 98.8 15 655 97.4 147 4% | 694 98.4 145 5 725 97.5 148 4 = 764 984 i 147 5 742 98.9 14 815 99.0 14 \ 1 279 | ry | : ! | 1 331 892 89.2 111 tt 1 608 92.2 * 721 92.2 141 141 I 236 646 962 2 759 96.3 140 141 3 794 ' 3 819 97.5 97.8 149 4 141 AF 835 985 976 98.5 147 in 149 5 3 888 99.0 14 1032 99.0 14 : i i \ : Recommended Thickness Heat Loss f1 hr Insulation Efficiency Surface Temperature it's the low tt hah t a thatt counts counts counts : counts counts 4 piping to 1200 Station Station | ol design data sBam e insulation thickness standards a - whe ee IRON PIPE SIZES IPS wee nom O.D. single layer only single or double layer multiple layer only pipe = of size = pipe nom " nom 1 nom 2 actual O.D. actual O.D. actual O.D. ---- 21/2 ---- 3 ---- 32 actual O.D. actual 0.0 actual O.D. nom 4 actual O.D. nom 4 nom 5 actual O.D. actual Q.D. .84 3 1.05 1.32 1... 1.66 1 1.90 1.00 .90 1.08 .90 1.03 2.88 2.88 3.50 3.50 4.00 1.56 1.46 1.58 1.66 1.53 4.00 4.00 4.50 5.00 5.00 2.06 1.96 2.11 1.94 2.36 5.00 5.00 5.56 5.56 6.66 2.89 2.79 2.66 2.48 2.86 6.66 6.66 6.66 6.66 7.66 3.39 3.29 3.16 2.98 3.36 7.66 7.66 7.66 7.66 8.86 2 2.38 2 2.88 3 3.50 3 4.00 4.50 4 5.00 5 5.56 6 6.63 al 7.63 8 8.63 1.04 1.04 1.00 1.30 1.05 4.50 1.57 5.00 1.87 5.56 1.55 6.66 1.80 1.55 1,30 1.02 .95 7.66 7.66 8.66 1.80 1.52 1.45 1.52 1.52 5.56 2.12 6.66 2.37 6.66 2.05 7.66 2.30 7.66 2.05 6.66 7.86 7.66 8.66 8.66 2.62 2.87 2.55 2.80 2.55 .2.30 9.66 2.86 8.66 2.02 9.66 2.58 9.66 10.78 2.02 2.02 10.78 2.52 11.78 2.53 11.78 2.03 12.81 2.66 7.66 8.66 8.66 9.66 9.66 3.12 3.37 3.05 3.36 3.11 10.78 3.36 10.78 3.08 11.78 12.81 3.03 3.16 14.06 3.16 8,66 9.66 9.66 10.78 10.78 11.78 11.78 12.81 14.06 15.06 3.62 3.93 3.61 3.86 3.61 3.88 3.59 3.66 3.66 3.67 9.66 10.78 10.78 11.78 11.78 4.18 4.43 4.11 4.38 4.13 12.81 12.81 14,06 15.06 16.09 4.50 4.22 4.16 4.17 4.13 10.78 11.78 11.78 12.81 12.81 4.68 4.95 4.63 5.00 4.75 14.06 14.06 15.06 16.09 17.00 5.00 4.72 4.68 4.63 4.63 11.78 12,81 12.81 14.06 14,06 5.20 5.57 5.25 5.50 5.25 15.06 15.06 16.09 17.00 18.00 5.51 5.23 5.13 5.13 5.13 12.81 14.06 14.06 15.06 15.06 16.09 16.09 17.00 18.00 19.00 9 10 11 12 14 9.63 10.75 11.75 12.75 14.00 1.53 1.59 1.58 1.59 1.42 12.81 14.06 15.06 16.09 17.00 2.16 2.09 2.09 2.05 1.92 4.06 2.66 15.06 2.61 16.09 2.55 17.00 2.55 18.00 2.42 15.06 3.17 16.091 17.00 18.00 3.06 3.05 3.05 19.00 2.92 16.09 17.00 18.00 19.00 20.00 3.63 3.56 3.55 3.55 3.42 17.00 18.00 19.00 20.00 21.00 4.13 4.06 4.05 4.05 3.92 18.00 19.00 20.00 21.00 22.00 4.63 4.56 4.54 4.54 4.42 19.00 20.00 21.00 22,00 23.00 5.13 5.06 4.55 4.55 4.92 20.00 21.00 22.00 23.00 24.00 15 16 17 18 19 15.00 16.00 17.00 18.00 19.00 1.42 1.41 1.41 1.41 1.41 18.00 19.00 20.00 21.00 22.00 1.92 1.91 1.91 1.91 1.91 19.00 2.41 20.00 2.41 21.00 2.41 22.00 2.41 23.00 2.41 20.00 2.92 21,00 2.91 22.00 2.91 23.00 2.91 24.00 2.91 21.00 3.42 22.00 23.00 3.41 24.00 3.41 25.00 3.41 22.00 23.00 24.00 25.00 26.00 3.92 3.91 3.91 3.91 3.91 23.00 24.00 25.00 26.00 27.00 4.41 4.41 4.41 4.41 4.41 24.00 25.00 26.00 27.00 28.00 4.92 4.91 4.91 4.91 4.91 25.00 26.00 27.00 28.00 29.00 20 21 22 23 24 20.00 21.00 22.00 23.00 24.00 1.41 1.41 1.41 1.41 1.41 23.00 24,00 25.00 26.00 27.00 1.91 1,91 1.91 1.91 1.91 24.00 25.00 26.00 27,00 28.00 2.41 2.41 2.41 2.41 2.41 25.00 2.91 26.00 2.91 27.00 2.91 28.00 2.91 29.00 2.91 26.00 27.00 28.00 29.00 30.00 3.41 3.41 3.39 3.39 3.39 27.00 28.00 29.00 30.00 31.00 3.91 3.89 3.89 3.89 3.89 28.00 29.00 30.00 31.00 32.00 4.41 4.41 4.41 4.41 4.41 29.00 30.00 31.00 32.00 33.00 4.91 4.91 4.91 4.91 5.00 30.00 31.00 32.00 33.00 34.00 25 26 27 28 29 25.00 26.00 27,00 28.00 29.00 1.46 1.46 1.46 1.46 1.46 28.00 29.00 30.00 31.00 32.00 1.98 1.98 1.98 1.98 1.98 29.00 2.50 30.00 2.50 31.00 2.50 32.00 2.50 33.00 2.50 30.00 3.02 31.001 3.02 32.00 33.00 34.001 3.02 3.02 3.02 31.00 3.44 32.00 3.44 33.00 3.44 34.00 3.44 35.00 3.44 32.00 33.00 34.00 35.00 36.00 3.96 3.96 3.96 3.96 3.96 33.00 34.00 35.00 36.00 37.00 4.48 4.48 4.48 4.48 4.48 34.00 35.00 36.00 37.00 38.00 5.00 5.00 5.00 5.00 5.00 35.00 36.00 37.00 38.00 39.00 30 31 32 33 34 35 36 37 38 39 30.00 31.00 32.00 33.00 34.00 35.00 36.00 37.00 38.00 39.00 1.46 1.46 1.46 1.46 1.46 1.46 1.46 1.46 1.46 1.46 33.00 34.00 35.00 36.00 37.00 1,98 1.98 1.98 1.98 1.98 38.00 1.98 39.00 1.98 40.00 1.98 41.00 1.98 42.00 1.98 34.00 2.50 35.00 2.50 36.00 2.50 37.00 2.50 38.00 2.50 39.00 2.50 40.00 41.00 42.00 43.00 2.50 2.50 2.50 2.50 35.001 3.02 36.00 37.00 | 38.001 3.02 3.02 3.02 39.00 3.02 40.00 3.02 41.00 i 42.00 3.02 3.02 43.00 3.02 44.00 3.02 36.001 3.44 37.00 3.44 38.00 39.00 t 40.00 3.44 3.48 3.48 41.00 42.00 3.48 43.00 3.48 44.00 3.48 45.00 3.48 37.00 38.00 39.00 40.00 41.00 42.00 43.00 44.00 45.00 46.00 3.96 3.96 3.98 3.98 3.98 3.98 3.98 3.98 3.98 3.98 38.00 39.00 40.00 41.00 42.00 43.00 44.00 45.00 46.00 47.00 4.48 4.48 4.48 4.48 4.48 4.48 4.48 4.48 4.48 4.48 39.00 40.00 41.00 41.00 42.00 43.00 5.00 5.00 5.00 5.00 5.00 44.00 5.00 45.00 5.00 46.00 5.00 47.00 5.00 48.00 5.00 40.00 41.00 42.00 43.00 44.00 45.00 46.00 47.00 48.00 49.00 . o@ e 46 piping to 1200 ; tdesign data t - insulation thickness standards oo C C O. of tube nom " - er ay ~ oer - COPPER TUBING CT ---- -- tube size * single layer nom ' nom 1 actual O.D. actual O.D. 1.18 1.11 2.88 2.88 1.49 1.42 3.50 3.50 ** ** 1.05 .99 2.88 2.88 1.61 1.55 4.00 4.00 1 \ ' 1 1.17 1.05 3.50 3.50 1.42 1.55 4.00 4.50 ** 21 185 2" 1.17 .91 4.00 4.00 1.42 1.41 4.50 5.00 21 2 .91 % 3 .91 4.50 5.00 1.45 1.73 5.56 6.66 insulation insulation insulinsulation ation efficiencies efficiencies efficiencies efeficiencifes iciencies " eftudency, porovt . D791 20475470 . | 980; : . 1 He 7 eg AGNES By rh oa 4 = ie a oa -! ve 7 100- he NTS NA TNS a ww 8S 3 200 TTS ata le SUUBEEASSSNS neh aS aN a ws NATCRUSKEAN @aw NR 300 temp diff pipe ai r 400 500 a a IN NO N bk SLAC D RAN BaANN N ORKAAIN NSAOKURK NIN . \ QISANATEVENLERVARSN YL nf N SAISON ASA SN AAT Dy a RA www SANNRANK wh NAA \ . ; WN N 600 : TROLEROKNE 700 * 1 Spiwlxfs KEYKEY CURVES a TO4 CURCURVVES CEURVESSCURVES [08] ta] 4] 04] seyaelar 1112345563747 1112345563747 123456374 11234563747 { 09 WICHOS 23 1234567 11234563747 10 98 11 9 7 TRICKNESS 2 12 14:14 14 3 TRICKNES134 134 14 12 6 10 14 14 16 15 17 16 17 18 19 19 16 19 19 19 19 19 15 16 17 17 17 19 20 10 20 20 20 21 21 212 15 15 16 17 17 17 19 20 10 20 20 212 21 212 1216 17 18 18 19 19 20 20 21 21 21 21 22 14 1216 19 19 20 20 20,20 20,20 21 | 21 22 22 22 22 22 ANCL NSAAARAARA VQULGRALMAINLSRLETAR A VARAAYAY 1A NN F WRAANAARS VAL AY NA Y N A \ SN aN AK Ad A -_; : 888 888 900 1000 1100 12 it's it's it's the carrive carrive carrive carrive carrive piping to 1200 F Kaylo pipe insulation insulation pipe Kayae with with with HPO Pay we pipingat of Net of pM} ary de tudiainsulation tda_el dtn os insulation Pear for Rent thass cork 4 3 , me binedeanh 48 Ede specification for insulation of piping with Kaylo pipe insulation 1 Insulating materials All heated pipes shall be insulated to the thickness noted on drawings or as shown in the following table with Kaylo Pipe Insulation as distributed by Corning Fiberglas Corporation eee wee AK ee oe TABLE OF RECOMMENDED INSULATION THICKNESS Recommended Thicknesses vary according to use wee ee See pages 43-45 for Complete Recommended Thickness Table 2 Application All Pipe Insulation shall be applied over clean dry surfaces butting adjoining sections firmly together Insulation on pipes under 12 diameter shall have applied canvas pasted neatly in place and be secured with factory furnished bands spaced on not greater than 18 centers Insulation on pipes over 12 diameter and all outdoor piping shall be wired in place with 16 gauge soft annealed wire on no greater than " centers Where double layer insulation is applied the first layer shall be wired in place without jacket the second layer shall be applied with all joints staggered All flanges valves and fittings shall be insulated with fabricated mitered segments of pipe insulation equal in thickness to the insulation on the adjoining pipe Fittings on pipe size of and smaller may be insulated with insulating cement of equal thickness 3 Surface finish Indoor piping under 12 diameter not subject to abrasion or mechanical abuse requires no finish in addition to the furnished canvas and bands Piping over 12 diameter shall be finished with ounce canvas pasted in place Piping located outdoors shall be finished with 45 roofing felt jacket with all joints lapped not less than Ja ckets shall be wired with 16 ga copper wire on not greater than " centers or banded on 12 centers with galvanized bands Other suitable weatherproof jackets such as metal asphalt or plastic coating may be applied according to the jacket manufacturers specifications Insulation on flanges valves and fittings shall be covered with a ... coat of finishing cement Portland cement to a maximum of 25 dry weight may be added if a harder finish is desired Insulation located indoors shall be further finished with canvas neatly pasted in place All insulation on flanges valves and fittings located outdoors shall be covered with asphalt weatherproof mastic reinforced with an open mesh glass fabric Mastic shall be applied in sufficient thickness to give a ... dry coat and shall be troweled neatly over the fitting and lapped over the jacket on the adjacent pipe e The specification is recommended as written Minor variances of application procedure may be made at the discretion and responsibility of the design engineer to meet specific job requirements CORNING FIBERGLAS piping tto o 1800 F Xayi20 pipepipe insulatic INT.C July 195 high temperature insulation and fireproofing for indoor or outdoor piping up to 1800 operating temperature ee ee ee bee eee + 6 ee eer Kaylo pipe insulation Kaylo Insulation a new temperature calcium silicate heat insulation developed and manufactured by Illinois extends the range of Kaylo Heat Insulation offered by OwensCorning Fiberglas to include temperatures up to 1800 with all the properties of moisture resistance and high strength of standard Kaylo material This new product which is a light pink color and can in this way be distinguished from standard Kaylo material combines the most desirable physical characteristics of heat insulation materials to a degree not equalled by most other materials in its temperature range It is designed for all high temperature applications including fireproofing jackets Standard canvas jackets are provided at no additional charge with Kaylo Sectional Pipe and Tube Insulation on thicknesses up to and including 2Bands are available for use with this product at a small additional charge and will be shipped only on request 6 oz and 8 oz canvas jackets are available on all types sizes and thicknesses of Kaylo Pipe Insulation at additional charge These jackets are factory applied on sectional pipe and tube insulation On segmental insulation they are furnished but not adhered thickness Pipe Insulation is available in thick- nesses from " to " depending upon pipe size Kaylo Tube Insulation is available in thicknesses of and 1 pipe sizes Pipe Insulation is available to fit pipe from 2 to 39 in diameter Kaylo Tube Insulation in copper tubing sizes will fit tubing from to 3 forms Pipe Insulation is available in sectional or segmental form depending upon pipe size All insulation is furnished in 3 sections T.M. Illinois Glass Co. T.M Corning Fiberglas Corp offers simplified dimensional standards of insula- correspond tion to those of standard pipe assuring proper fit for each pipe size and permit nesting of insulation to build up greater thicknesses than those available in standard thick- nesses Kaylo Insulation also may be used with outer layers of standard Kaylo or Fiberglas Pipe Insulation to provide the ultimate balance of cost and efficiency high efficiency Insulation ranks among the most efficient insulations in its temperature range water resistance Pipe Insulation retains an appreciable percentage of its strength even when saturated with water After being soaked and then dried it returns to its original thermal efficiency and strength without shrinkage or warping high strength Insulation has flexural strength compression strength and resistance to abrasion far above normal requirements for heat insulation reducing breakage during installation and in service easy fabrication Insulation can be cut scored or sawed with ordinary tools of the trade It is irritating to the skin and toxic highly low shrinkage Insulation is dimension- ally stable at the temperatures for which it is designed Even at 1800 it will not crumble but retains its original form fireproofing resistance of this insulation to high tem- peratures makes it extremely useful for fireproofing piping limitations Kaylo material is designed for temperatures up to 1800 It should not be used when operating temperatures of piping exceed this limit o x. oe de helene oe Ges Sie Sw we we ~ eTPaden, wT cP piping to 1800 . design data 6a Ow insulation thickness standards IRON PIPE SIZES IPS COPPER TUBING CT hom pipe size ** ** 1... 11 O.D. of single layer only ---- " nom 14 single or double layer ---- 2 nom 2 nom " pipe actual O.D. actual O.D. actual O.D. actual 0.0 actual O.D. .84 1.05 1.32 1.66 1.90 1.00 .90 1.08 .90 1.03 2.88 2.88 3.50 3.50 4.00 1.56 1.46 1.58 1.66 1.53 4.00 400. 4.50 5.00 5.00 2.06 1.86 2.11 1.94 2.36 5.00 5.00 5.56 5.56 6.66 2.89 2.79 2.66 2.48 2.86 6.66 6.66 6.66 6.66 7.66 3.39 3.29 3.16 2.98 3.36 7.66 7.66 7.66 7.66 8.66 2 2 3 3 2.38 2.88 3.50 4.00 4.50 1.04 1.04 1.00 1.30 1.05 4.50 5.00 5.56 6.66 6.66 1.57 1.87 1.55 1.80 1.55 5.56 6.66 6.66 7.66 7.66 2.12 2.37 2.05 2.30 2.05 6.66 7.66 7.66 8.66 8.66 2.62 2.87 2.55 2.80 2.55 7.66 8.66 8.66 9.66 9.66 3.12 3.37 3.05 3.36 3.11 8.66 9.66 9.66 10.78 10.78 O.D. of tube nom K K nom luba size single layer nom " nom 1 actual = O.D. actual Q.D. % 1.18 2.88 1.49 3.50 % % 1.11 1.11 2.88 2.88 1.3 42 .50 %% = 1.05 2.88 % % .99 2.88 1.61 4.00 1.55 4.00 4 5 6 7 8 5.00 5.56 6.63 7.63 8.63 1.30 1.02 .95 7.66 7.66 8.66 1.80 1.52 1.45 1.52 1.52 8.66 8.66 9.66 10.78 11.78 2.30 2.02 2.02 2.02 2.03 9.66 9.66 10.78 11.78 12.81 2.86 2.58 2.52 2.53 2.66 10.78 10.78 11.78 12.81 14.06 3.36 3.08 3.03 3.16 3.16 1178 11.78 12.81 14.06 15.06 9 9.63 10 10.75 11 11.75 12 12.75 14 14.00 1.53 1.59 1.58 1.59 1.42 12.81 14.06 15.06 16.09 17.00 2.16 2.09 2.09 2.05 1.92 14.06 15.06 16.09 17.00 18.00 2.66 2.61 2.55 2.55 2.42 15.06 16,09 17.00 18.00 19.00 3.17 16.09 3.06 17.00 3.05 18.00 3.05 19.00 2.92 20.00 15 15.00 16 16.00 17 17.00 18 18.00 19 19.00 1.42 1.41 1.41 1.41 1.41 18.00 19.00 20.00 21.00 22.00 1.92 1.91 1.91 1.91 1.91 19.00 20.00 21.00 22.00 23.00 2.41 2.41 2.41 2.41 2.41 20.00 21.00 22.00 23.00 24.00 2.92 2.91 2.91 2.91 2.91 21.00 22.00 23.00 24.00 25.00 20 20.00 21 21.00 22 22.00 23 23.00 24 24.00 1.41 1.41 1.41 1.41 1.41 23.00 24.00 25.00 26.00 27.00 1.91 1.91 1.91 1.91 1.91 24.00 25.00 26.00 27.00 28.00 2.41 2.41 2.41 2.41 2.41 25.00 26.00 27.00 28.00 29.00 2.91 2.91 2.91 2.91 2.91 26.00 27.00 28.00 29.00 30.00 1 % % 1 1.17 3.50 1 1.05 3.50 11 1.17 4.00 1.42 4.00 1.55 4.50 1.42 4.50 2 2 .91 4.00 1.41 5.00 % ; % 2 .91 4.50 3 .91 5.00 1.45 5.56 1.73 6.66 , Sizes above 3 available in multiple layers 25 26 27 28 29 30 wwwww wwwww wwwww wwwww 25.00 26.00 27.00 28.00 29.00 30.00 31.00 32.00 33.00 34.00 1.46 1.46 1.46 1.46 1.46 28.00 29.00 30.00 31.00 32.00 1.98 1.98 1.98 1.98 1.98 29.00 30.00 31.00 32.00 33.00 2.50 2.50 2.50 2.50 2.50 30.00 3.02 31.00 3.02 32.00 3.02 33.00 3.02 34.00 3.02 31.00 32.00 33.00 34.00 35.00 1.46 1.46 1.46 1.46 1.46 33.00 34.00 35.00 36.00 37.00 1.98 1.98 1.98 1.98 1.98 34.00 35.00 36.00 37.00 38.00 2.50 2.50 2.50 2.50 2.50 35.00 | 3.02 36.00 3.02 37.'03.002 38.00 3.02 39.00 3.02 36.00 37.00 38.00 39.00 40.00 } Note Insulation for the nominal pipe size range of 25 39 is furnished to fit a range of 5 pipe sizes The lost segment applied be musct ut to At accurately 35 35.00 36 36.00 37 37.00 38 : 38.00 39 39.00 1.46 1.46 1.46 1.46 1.46 38.00 39.00 40.00 41.00 42.00 1.98 1.98 1.98 1.98 1.98 39.00 40.00 41.00 42.00 43.00 2.50 2.50 2.50 2.50 2.50 40.00 3.02 41.00 3.02 42.00 3.02 43.00 3.02 44.00 3.02 41.00 42.00 43.00 : 44.00 : 45.00 it's it's it's the the the lloo w lw ow 1.7 1.7 fe 1 S24 4 lle 1 51 piping to 1800 F Kaylo pipe insulation , a % uoriv nsuiuorivinsui uorivnsui did nz ^ih^,y unm Burdid o uojinsur tof specification for insulation of piping with Kaylo pipe insulation vacaw swe ramrrmee et CE TEN racemes TS 8 Re Er Set nee e oo 1 Insulating materials All heated pipes shall be insulated to the thickness noted on drawings or as shown in the following table with Kaylo 20 Pipe Insulation as distributed by Corning Fiberglas Corporation were OF mn om TABLE OF RECOMMENDED INSULATION THICKNESS | binstue RAMUTS ABLE 6 NET Teed ... Recommended Thicknesses vary according to use hee ee oe e ee ee ome See pages 50-51 for Complete Recommended Thickness Table 2 Application All Pipe Insulation shall be applied over clean dry surfaces butting adjoining sections firmly together Insulation on pipes under 12 diameter shall have factory canvas pasted neatly in place and be secured with factory furnished bands spaced on not greater than 18 centers Insulation on pipes over 12 diameter and all outdoor piping shall be wired in place with 16 gauge soft annealed wire on no greater than " centers Where double layer insulation is applied the first layer shall be wired in place without jacket the second layer shall be applied with all joints staggered All flanges valves and fittings shall be insulated with fabricated mitered segments of pipe insulation equal in thickness to the insulation on the adjoining pipe Fittings on pipe size of and smaller may be insulated with a suitable insulating or refractory cement of equal thickness 3 Surface finish Indoor piping under 12 diameter not subject to abrasion or mechanical abuse requires no finish in addition to the furnished canvas and bands Piping over 12 diameter shall be finished with ounce canvas pasted in place Piping located outdoors shall be finished with 45 roofing felt jacket with all joints lapped not less than Jackets shall be wired with 16 ga copper wire on not greater than ce nters or banded on 12 centers with galvanized bands Other suitable weatherproof jackets such as metal asphalt or plastic coating may be applied according to the jacket manufacturers specifications Insulation on flanges valves and fittings shall be covered with a ... coat of finishing cement Portland cement to a maximum of % dry weight may be added if a harder finish is desired When located indoors finish with canvas neatly pasted in place When located outdoors cover with asphalt weatherproof mastic reinforced with an open mesh glass fabric Mastic shall be applied in sufficient thickness to give a ... dry coat and shall be troweled neatly over the fitting and lapped over the jacket on the adjacent pipe The specification is recommended as written Minor variances of application procedure may be made at the discretion and responsibility of the design engineer to meet specific job requirements FIBERGLAS equipm & insulatons Q a Vi > | insulations SuocreBynsul sucUdINbs CORNING OWENS FIBERGLAS equipment to 1200 insulat Neyic block blockblock insulat insulat oe INI.C18 July 1956 ? 6a i - H Ow high temperature insulation ( 1 for heated equipment up to 1200 An mee ae oe ee a ee ee Kaylo block insulation Kaylo Block Insulation a while rigid hydrous calcium silicate heat insulation developed and manufactured by Illinois Glass Company and distributed nationally by Corning Fiberglas Corporation effectively insulates indoor and outdoor heated equipment up to 1200 Kaylo Block Insulation offers excellent heat insulation high strength and moisture resistance to a variety of high temperature installations A chemically material il contains asbestos fibers for reinforcement Kaylo Block Insulation combines the most desirable physical characteristics of heat insulating materials to a degree not equalled by most other materials on the market This means outstanding performance and economical application for the user beveled lags For pipe sizes greater than those for which Kaylo Insulation sizes are available Kaylo Beveled Lags may be used to insulate piping These lags are blocks of Fiberglas Insulation beveled to fit snugly on large standard sizes of heated piping Lags beveled to fit pipes from 18 to 36 in diameter are available in thicknesses of 1" 2and " 36 long offers high efficiency k places it among the most effi- cient insulations in its temperature range Eliminates the need of two dissimilar materials in the temperature range of 600 to 1200 Insulating effectiveness results from countless tiny entrapped air pockets water resistance an appreciable percentage of its strength even when saturated with water Returns to its original strength and efficiency if briefly wetted with no shrink- age or warpage high strength light weight superior flexural strength and resistance to abrasion to a degree far above normal requirements for a heat insulation Reduced breakage during installation and in service Temperatures up to 1200 have no effect on its strength easy fabrication tools of the trade sufficient for all cutting scoring or sawing Light weight pleasant hand- . ling and irritating toxic nature make it a liked worker's material low shrinkage effective after long service at high temperatures Dimensionally stable it shows little shrink- age even after exposure to high temperatures Won't crumble but retains its original form versatility efficiently on temperatures through the hot water and low pressure steam range in addition to temperatures in the superheated steam range ey width 6 12 and 18 length to 36 thicknesses 1 2 and form T M. Owens Glass Company it's the Kaylo Block Insulation is designed for application on high ternperature equipment operating up to 1200 It should not be used on vessels operating above that limit For underground use it requires a good moisture and vapor barrier On outdoor use it should be protected with a weatherproof finish All values given are subject to normal manufacturing and test- ing tolerances Se. RCI . ay rad ~ counts counts counts 93 Seyte ae ae, teh bt * eo ~ ES data design design ay AE design design data data ddesign esign data ns design SOS design data neo recommended thicknesses 7 insulation ae insulation etne Sep insulation ba insulation Nelamnel block OTe tou Soe te atl ete Kaylooi + ad with dtedt with e af dbo equipment cade ted equipment bs equipment be wana a heated yesee of an wpe compressive compres ive compressive -~- compressive : og? strength - . defani strength at % deformation' of 144 xq ^finat 1000 123 lb./ ba 1200 K~ . 190 sq in at 750 117 thfeg te 2 efter bollfori24nhgr 74 16./s oh fbi wall! -a { 1200 at 7504. = 1000 % os - "e . 2 7 ty, Pa resistance to abrasion fweight fam after min 4 after beating for 24 hr^ CTE % at 750 % , at 1000 -57 at 1200 ad for dime stabn ilitys linei ar shrio nkagen aftera heatinl g 24 hours s se eB at 7507. at 7-0.9 12007. Jo 4 at 12007. 1.5 | sionafteg r sa att u miaxo0.n 04 % thermal conductivity | 7 x Gafte. oe Ofte : -- 4 : i eo} - a a8 oe = Loo ae . +, tf eee tt eee : a a , a ee a er er ee ee et : , - 4 3 oo : ctels, ambient temperature 80 F. COMMERCIAL POWER 201- 201- 2 43 92.8 106 1 . 78 87.2 124 1 78 87.2 124 300- 3 45 95.9 106 83 92.3 125 2 119 89.1 142 88 46 97.0 107 2 72 95.8 120 1 115 93.4 140 temperature temperature temperature 009 temperature temperature temperature temperature 700 equipment equipment equipment equipment equipment 5 48 98.2 108 3 79 96.9 123 1 148 94.2 153 36 03 977977 925 2 140 96.1 151 not applicable 4 79 98.4 124 2 137 97.2 150 900 S 84 98.9 126 3 135 979 149 1000 & 79 99.0 124 3 136 98.4 148 pot 4% ] 99.2 125 4 136 98 148 1200 7 89 993 127 4 138 99.0 149 Rec Thick Hact Loss Efficiency Surface Temp insulation specification specification specification specification insulation the for of equipment Kaylo the insulation 1 Insulating material All high temperature equipment thick Kaylo Block Insulation as heated shall be insulated with distributed by Corning with with block insulation level surface before applying blocks Then ed specifications above for flat surfaces 3 Finishing methods follow recommend- Fiberglas Corporation 2 Application methods FOR CURVED SURFACES OVER 39 Hold in place with 14 Pret peey' tty galvanized steel bands on work up to 48 diameter and bands on work over 48 diameter Bands to be spaced on 1218 inch centers Point and then apply hexagonal wire mesh or metal lath wiring to bands and laced edges Note The maximum temperature for the bands should be establish- ed by the metal band manufacturer due to the expansion of the equipment when heated F^ RFLAT SURFaces in place with 6 gauge annealed wire i < a rt Weyif. or wire cables attached to welded rods or studs Point and then apply hexagonal wire mesh or metal lath over entire surface Securely fasten down and lace the edges FOR IRREGULAR SURFACES a filler coat of insulating cement to cover the high points of all irregularities Trowel to MINIMUM INDOOR FINISH for further finishes Apply coat of mineral wool insulating cement Let dry Apply ... coat of finishing cement GOOD INDOOR FINISH not require painting To mini- mum finish apply 6 or 8 oz canvas between coats of white lagging adhesive WEATHER RESISTANT FINISH FOR OUTDOORWORKOUTDOORWORKminimum finish trowel two coats of a suitable asphalt or vinyl base weather resistant mastic reinforced with Fiberglas fabric be tween coats Each coat to be at least 8 thick Reinforce coating with open weave glass fabric ot The specification is recommended as written Minor variances of application may be made at the discretion and re- procedure sponsibility of the design engineer to meet specificspecific job requirements 94 CORNING OWENS FIBERGLAS vite equipment equipment equipment equipment equipment equipment equipment equipment equipment to to 1800 Keyle block insul IN1.C19 July 1956 | high temperature insulation | and fireproofing for heated equipment up to 1800 i ----- iow Kaylo block insulation This new high temperature culcium silicate block insulation developed and manufactured by Illinois Glass Co. extends the offers use of Kaylo Equipment Insulation to include temperatures up high efficiency low coefficient of conductivity or to 1800 This new product adds increased temperature tolerance k of Kaylo Block places it among the most efficient insu- to the properties of moisture resistance high strength and superior lation in its temperature range heat insulation performance of standard Kaylo Block Insulation This new product which is colored a slight pink and in this way can be distinguished from standard Kaylo Insulation brings the most desirable physical characteristics of heat insulation material to this high temperature range It may be used as single layer insulation for flat surfaces up to 700 and in double layers from water resistance Block retains an appreciable percentage of its strength even when saturated with water After soaking and then being dried both in tests and in service it returns to original efficiency and strength with no shrink- age or warpage this temperature to 1800 or may be used as a first layer with high strength Block combines light weight with standard Kaylo or Fiberglas Block superior flexural strength compressive strength and resistance The high temperature limit suits this product to all high tem- to abrasion These properties far above normal requirements for heat insulation serve to reduce breakage during installa- perature applications including refractory wall backing for furnaces tion and in service Even at 1800 this material retains its 4.9 and boilers and fireproofing of equipment and vessel skirts strength sizes thicknesses 1 12 2and 3 inches widths 3 6 12 and 18 inches length 18 and 36 inches special forms Curved block and thicknesses over three inches are available on special order easy fabrication Block can be cut scored or sawed with ordinary tools of the trade Light weight pleasant handling and irritating and toxic nature contribute to worker being on the job low shrinkage Block will remain effective after long service at high temperatures Dimensionally stable it shows little shrinkage even after exposure to temperatures up to 1800 It will not crumble but retains its original form fireproofing resistance of Kaylo block to high tem- peratures makes it extremely useful material for fireproofing metal work Kaylo beveled lags For pipe sizes greater than those for which Kaylo Pipe Insulation sizes are available Kaylo Beveled Lags may be used to insulate piping These lags are blocks of Kaylo Insulation beveled to fit snugly on large standard sizes of heated piping Lags beveled to fit pipes from 18 to 36 in diameter are available in thicknesses of 1 2and " Lags are 36 long T M. Illinois Glass Company limitations Kaylo Block is designed for temperatures up to 1800 It should not be used when operating temperatures exceed this limit it's the low Properties and characteristics have been determined from laboratory tests Data is subject to change without notice and is subject to normal manufacturing and testing tolerances fin! Fa i fa = e is physical properties density approximately 12 lbs per cu ft flexural strength 50 lbs per sq in compressive strength 100 lbs per sq in at % deformation dimensional stability linear shrinkage after heating for 6 hours at 1800 less than % moisture adsorption by volume after 6 hours exposure in atmosphere of 120 and 90 relative humidity 0.9 working temperature up to 1800 Kayla Block may be attached to equipment with the wires laced the methods wires or studs and speed clips or other accepted attaching Finish may be cement over wire mesh or other standard finish for insu- lated equipment design data The table below presents recommended thicknesses of Kaylo Block for different temperatures of equipment These are aver- age figures and may be adjusted to meet special conditions encountered on specific jobs Kaylo heat loss data is available for use where plant operating economics or other condi- tions may require special insulation engineering recommended thicknesses temp diff het surface to air deg F. -80 ambient temperature temp diff 1100 1200 thickness 5 6 1300 1400 6 7 1500 1600 7 8 wy a> eams . 1700 1800 81 . 9 For temperatures to 1200 use standard Kaylo block at recommended thicknesses c mat oemen me om ... . ... terete? Kaylo Block can be easily cut with ordinary tools of the trade to eaaeeb At around any obstruction Here Kaylo Pipe and Block Insulation are used to effectively insulate Intricate high temperature equipment dar aaglpvhin- os ALBANY N. Room 810 11 North Pearl Street ALBUQUERQUE N. M. P.O. Box 7067 Old Town Station ANCHORAGE ALASKA Post Rd & Ship Creek P.O. Box ATLANTA 3 GA 1726 Fulton National Bank Building BALTIMORE , MD 409 Baltimore Life Building BIRMINGHAM ALA 2229 First Ave. North BOISE IDAHO MAS 2525 Ark Street BOSTON 16 MASS 820 Statler Office Building BUFFALO 2 N. 401 Hodge Building 833 CHARLESTON W. VA 312 Berman Building Virginia St. CHARLOTTE N. 1106 Johnston Building CHICAGO , ILL 3236 Pure Oil Building CINCINNATI 6 OHIO Room 1031 2330 Victory Parkway CLEVELAND 15 OHIO = 1024 Hanna Building COLUMBUS 15 OHIO 2110 Leveque Tower DALLAS 4 TEXAS 101 United Bankers Life Building DAYTON 2 OHIO 129 N. Ludlow Street DENVER , COLO P.O. Box 906 DETROIT 2 MICH 516-517 New Center Building FORT WAYNE IND 255 Central Building FRESNO CALIF 427 P Street GRAND RAPIDS 2 MICH 424 McKay Tower GREENSBORO N. 221 Watson Building GREENVILLE S. C. Room 216 Capers Building HARTFORD CONN 36A Woodland Street HOUSTON 19 TEXAS 1939 West Gray Street Room 204 INDIANAPOLIS 4 IND 625 Architects & Builders Building JACKSONVILLE FLA Room 420 Atlantic National Bank Building KANSAS CITY 10 MO 2610 Power & Light Building KNOXVILLE TENN 404 Burwell Building LOS ANGELES 5. CAUF 3445 W. Eighth Street 4 LOUISVILLE KY 2106 Hahn Street eee: Ee MEMPHIS TENN 814 Dermon Building 46 North Third Sheet - FLA Box 987 Coral Gables Fla CORNING FIBERGLAS MINNEAPOLIS FIBERGLAS FIBERGLAS NNEOWRFORLOERALNSKoom203 West Street SiScuietcuet : eo Coen oa a mere : os a coy . 7140 Plankinton Building MINNEAPOLIS MINN MINN1925 995 a P.Q. 1700 Rond Tower Broad Street Street ; | J.12 307 Pon American Life laa,ilding Room 22 East 203 810 West 21st OMAHA NE Keeline Building . 700 First National Bank Building PHILADELPHIA 3 PENNA 1616 Walnut Stret Building tue : Industrial Contractorswho 1860 West Gateway Center Fiberglas located isenll and apply Fiberglas Industrial Insulations are "4 " ; PHOENIX ARIZ ; PITTSBURGH PENNA Building No. 2 PORTLAND 4 ORE 1044 Pacific ding ... RICHMOND 19 VA 1010 Central Bank Building National ROCK ISLAND KL Ave. ae - | 1907 2nd .. SACRAMENTO 14 CALIF 1615 Thornton branchfor principal cities Call your Fiberglas pages the telephone directorytdirehctoeryir ad res es addresses or see the yellowyellowyellow pages ofof telephone directory ST LOUIS 1. MO 1006 Olive StreetThornton SALT LAKE CITY 1 UTAN 336 South Third West . SAN ANTONIO TEXAS 335 New Moore Building - | SAN DIEGO 3 CAUF AvFe iftn h Au vene ue . . SAN 4 CAUF 1200 17th .. Ste le 7 FRANCISCO Street 2, cel Jose Builders , -7... "7" SAN JOSE 10 CALIF San Exchange TOS por SEATTLE WASH 1077 Horton Building 4 WASI 3044 Avenue SYRACUSE - 218 E. Trand : Y. 218 Harrison OHIO TOLEDO TULSA OKLA 642 National Building 902 American Airlines WASHINGTON 6 C. 806 WICHITA KAS 2520 East Kellogg INTERNATIONAL DIVISION 16 East St. New York N. Y. Corning Fiberglas Corporation GENERAL OFFICES AND GENERAL PRODUCTS Toledo Ohio PACIFIC COAST Santa Clara Calif TEXTILE PRODUCTS New York N.Y. it's the low& counts that PRINTED IN 8b Ow VMechani C a systems insu ca r on October Qwens-Coring 1969 Fiberglas ff F ozrYofh 4 5 MECHANIL SYTEMS INSULATIONS -~ INSULATION selection guide PLUMBING PIPING & EQUIPMENT SYSTEMS temp range products 2 PIPING 3 Chilled Drinking Water z Rainwater Leaders 3 35-50F PIPE INSULATIONS Heavy Density Piece Fiberglas 25 P = Drain Lines Bs Bent Soft Copper i Connections 35-50F C Flexible Tubing page 4-9 10-14 15-17 18-19 ae oie Pe) ET hE Domestic Cold Water Boiler Makeup Water 50-60F Heavy Density Piece Fiberglas 25 C.P 4-9 10-14 15-17 Domestic Hot Water Tempered Water Booster Heater Water to 180F Heavy Density Piece Fiberglas 25 H.P 4-9 10-14 20-22 EQUIPMENT Hot Water Storage Tanks Heat Exchangers Hot Water Generators Booster Heaters 150-180F EQUIPMENT INSULATIONS 700 Series Kaylo Block Fiberglas 25 E 23-25 26-27 28-29 Products shown in BOLD FACE type are recommended for use for the services shown based on performance and widespread acceptance Other products are listed be- cause of local conditions or product preference RA A 2 TT EATS HE OLD Bey rn Pe a fed Chan, " z yt ay,lage rsaaad a f, : so * eae MECHANICAL PIPING SYSTEMS system temp range products PERENG Ft 5Ral eh 3 SE EO ea page ke SRR APTA ICS PIPING PIPE INSULATIONS Refrigerent Suction Chilled Water Primary and Secondary Cooling Tower Water IPS -20 to 35F Heavy Density Piece Fiberglas 25 C 4-9 10-14 15-17 Refrigerent Suction Chilled Water Bent Soft Copper Connections O to 70F C Flexible Tubing 18-19 Temperature Make Water Heating Hot Water FuelFuel Fuel Heating PipPiingpiPipinng g High Temperature Hot Water SteaSm team and and ConCdeonsnatedensate 35 to 60F . to 1200F Heavy Density Piece Fiberglas 25 P Heavy Density to 450F Piece to 400F Kaylo to 1200 ) Fiberglas 25 H.P to 450F 4-9 10.14 15.17 4.9 10.14 30-31 20-22 MECHANICAL EQUIPMENT temperature products H Cold Equipment - 20F to 70F Type 705 Fiberglas 25 E Hot Equipment 70F to 1200F Type 704 to 450F S Board to 850F Metal Mesh Blanket to 1000F a Tv LAUR EOS ay 23-25 3 34-35 a 36-37 : a Wx Kaylo Block to 1200F Fiberglas 25 E to 450F Si ae Pree " =~ Z Fe = RATER ee ee 26-27 28-29 Ne TT TE 2 3 ? ee 2 nee ee Heavy Density tegehge Sectional Pipe Insulation SW re a r ^'. 2. a purpose rigid pipe insulation for all types ofpiping systems operating at temperatures from -120F to 450F eg eae a Sa I Fiberglas Heavy Density Sectional Pipe Insulation has a broad range of uses for hot and cold piping It is available with a variety of applied jackets to provide for appearance vapor barrier fire safety or weatherproofing to permit selection of the correct in- sulation for the service requirements from -120F to 450F See page 2 for a complete selection guide Fiberglas Heavy Density Sectional Pipe Insulation is a precision molded pipe covering composed of Fiberglas wool bonded and formed in two half cylinders up to 12 IPS It is available in 3 ft long sections to fit all sizes of pipe and tubing from IPS to 33 f a iy i 4 7 3 : 5 m3 &: a) t 3 ea $423 fot : 3 Bd _o t ron " superior thermal efficiency Fiberglas Sec- tional Pipe Insulation because of its low k factor provides high efficiency with resultant cost savings The closely knit glass fibers form millions of air pockets to retard the flow of heat for great er fuel savings and more precise temperature control resists compression Density Fiberglas Pipe Insulation resists compression and mechanical damage because it is denser than other glass fiber pipe insulations This means less chance of unsightly damage and puncture of the vapor barrier on cold lines dimensionally Fiberglas will not shrink or rot and will withstand thermal shock easy to fabricate Fiberglas Heavy Density Pipe Insulation is easy to cut and fit in the field with an ordinary knife No special tools are required and the firm clean sections knit tightly to gether forming an efficient thermal barrier at fittings and joints The rigid sectional form lends itself to accurate shop fabrication of valve and fitting covers inorganic The special compounded glass fibers are completely inert They will not corrode steel copper or aluminum pipe and will not cause stress corrosion in stainless steel factory applied jackets wide variety of fac applied jackets are available to provide vapor barrier protection weather resistance fire safety or damage resistance These jackets speed application in the field The new SelfSealing Lap jacket further simplifies installation and assures a moisture vapor barrier seal at the joints Trademark Registered Corning Fiberglas Corp ee , Le EM TIPE 4 THREby TERME " , boars Bg ee IE TREN : et DORs Dp TaCMT AD REI SEY er F EIT SRW 1 performance characteristics moisture absorption 0.2 by volume hrs at 120F and 95 capillarity negligible after 24 hours alkalinity ph specific heat 0.20 lb.F stress Corrosion will not cause stress corrosion cracking of stainless steel thermal conductivity 000 050 040 Film ) on aq Btu | | Thermal Condudivity of Various Mean Temperature | rit | | : 4 | OG OG SUNGLAS Cwcastin 1 e o 7S 100 110 100 250 300 350 Mean Temperature F 1960 ere 8b er re ee naa . ra | Ow ee e Fire Retardant Jacket left FRJ with Self Sealing > Lap and end joint sealing strip 5 e, Standard Canvas Jacket left PreSized Glass Cloth i with end joint closure strip mean temperature 75F 40F k 0.240 0.227 specification Compliance 1-558a Insulation Blocks Boards Blankets Felts Sleeving Pipe and Tube Covering and Pipe Filting Covering Thermal Mineral Fiber Industrial Type Form O Typa 111 Class 12 ASTM Specification 231.51T Glass Klad Metal Jacket left to right .016 Embossed Aluminum with snap locking joint .010 Stainless Steel with snap locking joint .010 Embossed Aluminum with overlapping jacket laps on end and longitudinal joints End joint sealing butt strips for end joint closure es _ NEATER JOBS are possible with Fiberglas Heavy Pipe Insulation because of its inherent rigidity cleaner with square neat edges Density It cuts ABUSE RESISTANT density means less chance of damage from ladders or other mechanical abuse during installation or in service PIPE INSULATION SELECTION PLUMBING & MECHANICAL SYSTEMS TO SERVICE REQUIREMENT HOT PIPING Plumbing Domestic Hot Water Tempered Water ._ -=s TEMPERATURE | F JACKETS AVAILABLE RECOMMENDED IN BOLD FACE TYPE CONCEALED EXPOSED 110-180 110-130 Fiberglas 25 completely fire safe glass cloth jacket sized for paint base End joint butt strips furnished Standard Canvas Jacket cost provides base for painting Heavier 6 or 8 oz weights available Fiberglas 25 Jacket surface eliminates field priming May be left as is or painted any color Canvas 6 oz or 8 normally sized and painted Mechanical Heating Hot Water Steam and Condensate Fuel Oil Piping High Temperature Hot Water COLD PIPING Plumbing oo Domestic Cold Water Chilled Drinking Water Rain Water Leaders Mechanical Secondary Chiled Chiled WatePrrimary and Temp Refrigerant Suction 150-210 210-450 210-450 250-450 FRJ with Self Sealing Lap Fire Re- tardant Jacket is a laminate of white kraft and foil reinforced with strong glass yams laminated with flame snuffing adhesive Meets requirements 301-1 Type of GSA A. be Jacket can used on heated and tem- perature lines up to 450F Butt joint strips to close end joints are furnished Also avail able without the Self Sealing Lap feature Self FRJ with Sealing Lap furtner finish required Neat white attractive finish Or may be painted with water based paint finished paint May be May finished with sizing & field apapppllieid ed applied 50-65 35-65 33-65 35-55 40-210 -50 to +35 FRJ with Self Sealing provides a posi tive vapor seal for all cold and chilled water lines FAJ Fire Retardant Jacket is a lami- nate of white kraft and foil reinforced with strong glass yarns Meets requirements of GSA 301-1 Type A jackets Laminated with flame snuffing barrier with low adhesive perm rating Excellent vapor 0.02 Jacket can be used on heated temperature and refrigerant lines from --120F to 450F Butt joint strips to close end joints are furnished Also available without the Self Sealing Lap | feature FRJ with Self Sealing Lap further finish required White appearance presents neat finished job May be finished with field applied 6 oz canvas sizing & paint . an oomat a ootax Chala, sens! OT, pen yraey wese OR ine fl te ka et Me a athe at aix SF tere tyr FRJ WITH SEALING installed by this unique method eliminates the need for stapling bands and lap adhesives The contact type adhesive offers a positive vapor seal at all joints and speeds application It's as easy as 1 2 3 1 start to peel the release paper off the vapor barrier 2 apply to pipe and peel off the balance 3 press the lap in OUTDOORS Glas factory applied .016 embossed aluminum or .010 stainless steel Complete with Integral longitudinal Pittsburgh seam and butt joint strips that lock out the weather Butt joint strips are furnished with weatherproof mastic protected with release paper Also available with .010 embossed aluminum without Pittsburgh seam having a twoinch overlap at the longitudinal seam and a 2 overlap on end joint Glas factory applied .016 embossed aluminum or .010 stainless steel Complete with integral longitudinal Pittsburgh seam and butt joint strips lock out the weather Butt joint strips are furrished with weatherproof mastic protected with release paper Also available with .010 embossed aluminum without Pittsburgh seam having a inch overlap at the longitudinal seam and a " overlap on end joint DESIGN CONSIDERATIONS The wide temperature range of Fiberglas Heavy Density Pipe Insulation permits the specifier to select material from one manufacturer to answer all the mechanical and plumbing system insulation requirements concealed exposed outdoors hot or cold A selection of jackets matched to end use and factory applied to the insulation assures maximum performance at the most economical cost Self Sealing Lap on FRJ Fire Retardant Jacket assures a positive vapor seal and serves to hold the insulation on the pipe This technological advance employs a unique chemical bonding agent that instantly seals and holds the joint lap tightly in place The bond also becomes stronger with age Butt joint strips of the same material are used on the end joints The use of staples bands and messy adhesives are eliminated and the attendant problems of fishmouths and other application defects in addition FRJ with Self Sealing Lap is fire retardant presents a neat white appearance and is glass fiber reinforced to resist damage Fiberglas 25 Jacket applied to Fiberglas Heavy Density Pipe Insulation is a completely safe insulation for hot or cold lines . No lagging is required before paintinThge jacket is tough resists damage and will not mildew or rot Fittings for cold lines are insulated with mitered segments or molded Fiberglas fittings which is subsequently wrapped with glass fabric and coated with vapor barrier mastic For hot lines the fitting is made smooth with insulating cement canvased and sized Fiberglas will not burn rot or shrink With the addition of FRJ or Fiberglas 25 Jacket the insulation is completely safe The exceptional low k factor means maximum economy and performance for all piping systems concealed exposed or outdoors Note All cold lines running outdoors require a weatherproofing jacket in addition to the factory applied vapor barrier place at the center and pressing hard work out toward either end Rub with the blunt edge of a knife End joints are sealed with a 3 wide butt strip of the same Sealing vapor barrier material recommended thickness Selection of insulation thicknesses for any spe- cific application should take into consideration the following important criteria 1. Cost of insulation applied 2. Cost of heat energy 3. Cost of capital 4. Cost of depreciation and in sulation 5. Capital investment in heat produc tion equipment 6. Temperature differential 7. Size of the pipe or surface 8. Conductivity of insulation cold Proper thickness see overleaf for tables is required for efficient operation and to prevent condensation on the insulation sur- face Specifically 1. Designed thickness should be specified to result in a surface temperature above the Point temperature of the surrounding air Generally this is equal to or greater than the economical thickness despite the relatively higher cost of cold Btu's 2. Insulation thickness should be based on ambient air conditions and corresponding permissible temperature differences Ambient Condition 90 F at 90 R.H. 90 F at 80 R.H. drop between ambient Permisible and insulation surface 3 7 F . 3. Piping operating down to freezing tem peratures or at fluctuating hot and cold temperatures should be insulated for max imum performance during the coolest part of the cold cycle ~ recommened thickness heated piping to 450F 80F ambient air ~~ Pipe Temp Temp Diff 200 120 IPS RT HL 1/2 3/4 CHAN 3M 11 1 CHAN 3M 2 CHANN3M 3 441 4 5 6 7 8 9 10 12 14 1 13 1 15 1 16 1 20 1 21 1 24 1 24 1 25 1 31 1 30 1 34 112 38 1 29 1 44 1 50 1 58 11222 48 11222 56 11222 63 300 220 ST | RT HL 91 J 1 24 94 | 1 29 92 1 30 95 | 1= 27 93 | 1 31 94 1 36 91 36 90 | N22222 39 92 | N22222 47 90 | N22222 47 92 | N22222 58 91 | N22222 58 88 } N22222 56 91 | N22222 74 93 | N22222 76 91 | N22222 80 88 | 2 76 89 | 2 88 89 2 99 400 320 ST { RT HL 101 1 32 106 42 102 1 42 95 1 45 96 1 50 97 | 1 58 95 95 | 2 60 2 56 96 2 58 2 64 97 2 58 95 2 80 2 95 95 | 2 95 | 2 96 2 100 104 118 93 223mm 111 93 127 94 223mm 142 heat loss lineal foot surface temperature F recommended thickness heat gain 450 370 ST | RT HL ST 100 1 39 105 104 104 1 45 += 120 49 108 104 | 2 51 104 107 | 2 57 107 107 | 2 104 | 2 60 103 72 108 97 2 69 98 2 71 + 99 97 2 80 100 96 2 100 | 3 101 | 3 98 84 70 95 100 102 0= 98 99 99 100 | 3 99 3 97 | 3 98 | 3 98 | 3 112 114 135 138 153 99 100 101 98 99 wet ' ' : a - i te a9) rer a Hedge r b { flfl flfl flfl "- "- i > : i t Fe ' ; r : : recommended thickness piping piping minus cold piping & temperature minus 60 to 200F 90F ambient air 90 relative humidity pipe surface temperature 40 F condition condition pipe alzat % % chilled water RT | HG IY i 3.8] 4.31) 1 1... % 1 4.7 5.3 1 1th 0 1 1 0 2| 22 1 22 7.2 7.5 35 F ice water RT | HG 1% 5 1% s 1 ^' 2 ^' 1 7 1 7 2 1316 2 1316 OF brine RT KG 2% $ 2% 6 2 4 2 ? 3 : 3 : 1316 1316 1316 1316 -30 F special brine RT HG 3 7 3 7 3 8 3 9 A 3 MM" 10 3 i k VW -60 F refrig- erants RT HG 3% 7 Ww a 3 -- % 11 3 VO a 11 12 ay 13 45 45 911993 911993 t 9 10 11 12 14 16 18 132 132 30 33 copper tubing 223 9.1 223 10.6 911993 911993 911993 911993 2 15 2 1s 2 7 24% j te 1 2 17 21 19 3| 21 3|} 24 133 2 133 2%}; 133 2| 37 21 40 3.5 32] 2 10 % |] 11 911993 911993 911993 911993 91 9 3 911993 2 15 2| 16 2% | 17 2% | 19 t 21 21 2| 23 13 13 13 13 13 13 134 135 134 135 1 333 1 333 3 12 3 13 911993 911993 911993 911993 3 17 3 1 4 16 4 2 4 21 4 23 4 25 a 29 136 136 136 136 4 19 4 19 %%% %%% %%% %%% %%% 1 111 14 |] 11/2 1% 1 2% Vy 3.5 1 3.8 3.9 194 4.2 4,5 1 5.0 4.9 1 5.4 54] 6.0! 1% 2 6.1 5.8 % | 22 % 4 22 3% 17 || 4% 17 SY 2 4 2 6.3 25 6.6 25 6.8 7.6 17 17 2 2 1 1 9.2 2 127 |] 2 9.6 ] 4 4 911993 911993 / / 4%, au S 5 3 3 135 135 35 51 13 4 15 15 ay 17 911993 911993 18 911993 911993 ye 18 S 21 20 5 22 22 3A 24 23 5% 25 24 5 39 28 4 27 31 132 132 31 132 132 33 ^' $ 37 $ 41 43 6 48 fl 6 54 Minimum thickness available above 12 IPS is " above 24 IPS is 1... 40 F 80 relative humidity 35 F OF -30 F chilled waler Ica water RT HG RT HG % 5.4 % $ % 6.2 % 7 % 7.1 % a % 8.4 1 9 % 94] 18162 18162 Hi i0R 18162 18162 % +] I t 12 12 ' 1 12.6 12 12 -- 14 14 1 16 18 1 20 12 14 14 12 14 14 291 291 22 291 1 22 i 32 Wy] 28 1 32 1% | 29 1 1133 1133 1133 1 41 11133 1133 | 1 44 1 39 1 52 12 43 1919 19 19 19 19 19 19 19 19 -- 82 1 70 || -- 91 1 77 4.0 % 4.3 44 % 4? % 48 % 5.3 % 5.2 % 5.8 4 6.3 % 6.9 % 7.2 % 7.8 % 8,0 % 9818.0 9818.0 11.5 %} 13.3 1 8.8 9818.0 11.1 10.6 1 609 11609 1609 11609 1609 11609 1 609 11609 1 13.9 1 15.2 1 16.1 |} 17.6 brine brine RT HG t 8 ivy 8 111 B 114 18162 18162 18162 18162 1 15 1 16 14 18 1 23 1 1 1 1 2 26 2 27 2 3 2 31 1 31 1 41 2 45 2 50 19 19 19 19 2 79 2 88 brine special special RT HG WwW 9 Wy 16 1 11 in 12 18162 13 18162 13 2 16 2 V7 22 20 22 24 1 3 1 3 3 333 3 333 2 39 2 al 31 32 31 44 2 49 2 54 19 19 19 19 2 83 2 92 -60 F refrig- refrig- RT HG iY YW 2 1a 2 11 2 14 218 218 218 218 2 17 242 18 2 21 2 25 2 28 24 31 3/1/20 34 3/1/20 37 2% 41 3 38 3 41 3 46 mm 50 mm 56 19 82 19 73 3 88 33 98 FIBERGLAS FIBERGLAS fray FIBERGLAS a Pipe Insulations F A versatile efficient quick applying pipe insulation for hot and cold piping from 30F to 450F description , Fiberglas Pipe Insulation is adaptable to all types of piping systems operating at temperatures from -30F to 450F It is available with a variety of applied jackets for appearance vapor barrier fireproofing or waterproofing to permit selection of the right combination of insulation and jacket for the service condition requirement Fiberglas Piece Pipe Insulation is a resilient lightweight pipe insulation molded from fine glass fibers in cylindrical form A single longitudinal seam which is opened to apply to the pipe springs closed when in place is available with a variety of applied jackets for appearance and function ere Lae td te dh D Sete A iee tee a oh er AY t Pn seer 4 a Pen, aeRR ee ee Re t F ik iorsatrert ante Pn eee : eee benefits economical application unit is ap plied quickly easily even in the larger sizes easy fabrication a knife is needed for fabrication of the most intricate fittings efficient of its very low k factor it is possible to reduce the thickness of insulation to provide thermal efficiency equivalent to other fibrous materials with savings in material costs Conversely the same thickness of One piece provides better thermal efficiency which results in savings in operating expense due to reduction in heat loss permanent Completely U.L. rated Inorganic glass fiber construction will not shrink rot or cause metal corrosion purpose variety of applications means less inventory A selection of factory applied jackets are available for surface finish vapor barrier weather protection fire proofing or damage resistance The new Sealing lap jacket speeds application in the field and assures a positive vapor barrier damage resistant resilient glass fibers spring back when bumped and Piece will not break if accidentally dropped during installation T.M Reg C F. Corp. ie oath Bie at Nay 4 cu * = aloe ' * . . gt sremegen a noenye natn, SNetr, emnacwr Tn rong 7" performance characteristics =~ i moisture absorption 0.2 by volume 96 hrs egie at 120F and 95 RH specific heat 0.20 Btu F. Een shrinkage None alkalinity ph9 thermal conductivity Unusually low thermal conductivity shown on chart * 050 PP Pee Thermal Conductivity al Various Maan Temperatures ia 40 { #f bq 0.30 h4 Btw 030 ae = = 4 all 10 ies At ating Gains COE Oe teat cme $medGt CosrQe ey ees { top tot yt 10 75 150 003 250 Mean Temperature 1960 . te a BeOe DUETa cieuntadcon i Dac 4 eee ek v ST a Te te,ne AMINced caeLealts ea. Pr 8 ome mean temperature k st 75F 40F 0.23 0.21 0.21 pyres ears os specification compliance ect iy omer 1-558a Form D Type III Class 12 1-562 Type II 1-223448 Ships woe 2. Weatherproof Jacket Lt og ted - Vaasa Neat Finished Appearance on this well insulatedinsulated chilled water rs 7 gm pg water water Self Sealing Lap vapor barrier jacket combines a positive vanoz with an attractive fire safe finished appearance for SYSTEMS PIPE INSULATION SELECTION PLUMBING & MECHANICAL SERVICE REQUIREMENT HOT PIPING Plumbing Domestic Hot Water Tempered Water Mechanical Mechanical Heating Hot Water Steam and Condensate Fuel Oil Piping High Temperature Hot Water COLD PIPING Plumbing wo Domestic Cold Water Chilled Drinking Water Rain Water Leaders Mechanical Chilled Primary and Secondary Temp Refrigerant Suction TEMPERATURE F JACKETS AVAILABLE RECOMMENDED IN BOLD FACE TYPE CONCEALED EXPOSED 110-180 110-130 150-210 210-450 210-450 250-450 Standard Canvas Jacket cost provides base for painting Heavier 6 or 8 oz weights available Fiberglas 25 - completely U.L. rated hot pipe insulation system U.L. rating includes jacket insulation fittings and ac- cessories FRJ with Self Sealing Lap Fire Retardant Jacket is a laminate of white kraft and foil reinforced with strong glass yarns laminated with flame snuffing adhesive Meets requirements of GSA 301 Type A. Jacket can be used on heated and tem perature lines up to 450F Butt joint strips close end joints are furnished Also avail- able without the Self Sealing Lap feature Available on Fiberglas Heavy Density Pipe Insulation only See data sheet 3853 50-65 50-65 33-65 35.55 40-210 -30 to -35 provides FRJ with Self Sealing tive vapor seal for all cold and a posi chilled water lines FRJ Fire Retardant Jacket is a lami- nate of white kraft and foil reinforced with strong glass yarns Meets requirements of snuffing GSA 301-1 Type A jackets Laminated with flame adhesive Excellent vapor barrier with low perm rating 0.02 Jacket can be used on heated temperature and refrigerant fines from -30F to 450F Butt joint strips to close end joints are furnished Also available without the Self Sealing Lap feature Fiberglas 25 - completely U.L. rated | cold pipe insulation system U.L. rating in- | cludes jacket insulation fittings and ac| cessories Available in Fiberglas Heavy Density Pipe Insulation only See data sheet 4376 - is E a . ? e nt se an ob ey ot Ye x & r. + fot 16476 16476 r eee a, hs src a, oe Bey oe a FRJ WITH SEALING installed by this unique method eliminates the need for stapling bands and lap adhesives The contact type adhesive offers a positive vapor seal at all joints joints and speeds application It's It's as easy as 1 2 3 1 start to peel the release ay ae : Ate + 1 CAyes? 5, t5z 30 OUTDOORS flake ce vase ee Cer : eee ee ee ee bee tee c A . a ree ee 2 A suitable weatherproof jacket applied over no wrap or factory jacket DESIGN CONSIDERATIONS The wide temperature range of Fiberglas Piece Pipe Insulation permits the specifier to select material from one manufacturer to answer all the mechanical and plumbing system insulation requirements concealed exposed outdoors hot or cold A selection of jackets matched to end use and factory applied to the insulation assures maximum performance at the most economical cost The Self Sealing Lap on FRJ Fire Retardant Jacket assures a positive vapor seal and serves to hold the insulation on the pipe This technological advance employs a unique chemical bonding agent that instantly seals and holds the joint lap tightly in place The bond also becomes stronger with age Butt joint strips of the same material are used on the end joints The use of staples bands and messy adhesives are eliminated and the attendent problems of fishmouths and other application defects In addition FRJ with Self Sealing Lap is fire retardant presents a neat white appearance and is glass fiber reinforced to resist damage Sized Glass Cloth Jacket factory applied to Fiberglas Heavy Density Pipe Insulation is a completely UL UL rated insulation for heated lines No lagging is required before painting The jacket is tough resists damage and will not mildew or rot UL tests show a low Flame Spread of 10 Fuel Contributed 0. Smoke Developed 0 Fittings for cold lines are insulated with mitered segments or molded Fiberglas fittings which is subsequently wrapped with glass fabric and coated with vapor barrier mastic For hot lines the fitting is made smooth with insulating cement canvased and sized Fiberglas will not burn rot or shrink With the addition of FRJ or Sized Glass Cloth Jacket the insulation is completely L. rated The exceptional low k factor means maximum economy and performance for all piping systems concealed exposed or outdoors Caution Corning Fiberglas Insulations are to be applied only with approved adhesives mastics and mechanical fastening devices as published in Accessory Materials List Pub No 3430 Corning Fiberglas accepts no responsibility or liability for the performance of materials other than those listed in this list unless approved in writing by O.CF Testing Laboratories : mas Sea Tee ee o eed place at the center and pressing hard work out toward either end Rub with the blunt edge of a knife End joints are sealed with a 3 wide butt strip of the same Sealing vapor barrier material . y7~ recommened thickness heated piping to 450F 80F ambient still air pipe temp IPS 120 RT HL ST 220 RT HL ST 400 RT HL ST 3/4 1 1 1 2 2 3 3 4 4 5 6 7 8 g 10 12 14 I 13 91 1 15 94 1 16 92 1 20 95 1 21 93 1 24 94 1 24 91 1 25 90 1 31 92 1 30 90 1 34 92 1 38 91 1 29 88 1 44 91 1 50 93 1 58 91 2 48 88 2 56 89 2 63 89 recommended thickness inches 1 23 101 1 32 100 I 23 106 1 42 104 1 3 102 1 42 104 1 2 95 1 45 104 1 788 1 788 2 788 96 1 50 107 97 1 58 107 95 2 60 104 2 39 94 Specify Fiberglas Heavy Density Pipe Insulation 2 47 96 for thickness above 2 2 47 94 N 58 522228 2 58 522228 2 56 522228 2 74 522228 2 76 522228 2 80 96 heat loss BTU lineal foot = surface temperature F co cold and temperature lines 90 F at % R.H. pipe surface temperature pipe size ) / 1 1 1 2 2 3 3 4 4 5 6 7 8 9 10 11 1Z 50 F or above RT HG 4 5 6 7 8 10 12 11 12 3/4 13 3 14 15 / 17 1 18 1 20 1 22 1 25 l 25 1 26 49 F to 35 F RT HG / chun 3/4 chun / 7 3/4 8 3/4 9 A 11 34 13 / 15 1 12 1 14 1 15 I 19 1 22 1 25 I 27 1 29 1 32 1 34 t 35 recommended thickness inches 34 F to F RT HG 1 8 l 9 1 8 1 9 1 10 1 12 1 15 1 16 1 18 1 13 1 22 1 23 1 25 1 28 1 www 1 www 1 www 1 w 1 A heat gain OF to -30 F RT HG 1 8 1 10 12 11 1 12 1 13 1 15 2 15 2 17 2 222222238 2 222222238 2 222222238 2 222222238 2 222222238 2 222222238 2 222222238 2 222222238 N 222222238 2 41 2 44 ; : x a + = * : Poe Lo: f be ee tons ty to : Lot _ : . es : io br i. 8b Ow Pipe Insulation Fiberglas 25 P Pipe Insulation A U.L. rated noncombustible pipe insulation system for cold service piping operating at temperatures down -120 F Recommend for use on all cold or service piping operating from 35 to 450 where rated non- combustible fire safety is desired as commercial and institutional buildings schools hospitals and places of public assembly Also recommended for processing lines where fire safety is a paramount criterion Fiberglas 25 Pipe Insulation System is composed of Fiberglas Heavy Density Sectional Pipe Insulation jacketed with a vapor barrier laminate of aluminum foil and sized glass cloth The jacket has a pres sure sealing lap adhesive on sizes up to 12 IPS 2 to eliminate the use of staples adhesives or bands The fittings are also combustible benefits fire safety complete insulation system with a UL rating including pipe fittings vapor barrier mastic when installed in accordance with recom- mended procedures lower operating cost the exceptional thermal effi- ciency of Fiberglas Heavy Density pipe insulation contributes to lower operating cost of cooling equipment and piping Peaych s cay factory ready for painting sized glass cloth jacket and matching tape and mastic system do not require field sizing If desired painting may be omitted If painting is required see Applica- tion recommendations damage resistant extra heavy density pipe insulation and extra tough woven glass cloth jacket resists damage on exposed lines no condensation drippage foil vapor barrier and pressure sensitive lap when applied as per instruction assure a positive vapor seal Fittings also provide a vapor seal installation savings Fiberglas 25 C pipe insulation system meets all existing standards for fire safety and its uses may result in lower insurance costs Fiberglas Reg U.S. Pat Off and 25 are trademarks of Corning Fiberglas Corporation et ee performance characteristics EB Insulation moisture absorption 0.2 by volume 96 hrs at 120F and 95 RH specific heat 0.20 Btu lb F shrinkage none alkalinity ph 9 capillarity negligible after 24 hrs dimensional stability - will not warp shrink rot or decompose vermin and rodent resistant no sustenance temperature recommended for chilled or temperature piping from 35 to 450 Jacket vapor transmission rate .05 perms burst strength 300 psi thermal conductivity .50 in .40 ft sq .30 .20 BTU .10 0 eee a | 75 100 200 MEAN TEMP F ! ot, saese Pee an { meray a) Poe me ... fire hazard classification Maximum Fire Hazard Classifications for building materials insulations as noncombustible have been established as follows Flame Spread Fuel Contributed Smoke Developed Acceptable 25 50 50 Fiberglas 25 P Pipe Insulation Systems including fittings is considerably below the maximum allowable This is your assurance that you can specify and use Fiberglas 25 C Pipe Insulation System without the danger of contributing to the spread of fire or that combustion will liberate excessive smoke The system has been designed to meet the stringent fire safety requirements of the GSA and Corps of Engineers Underwriters Laboratories Pipe & Equipment Coverings R5583 40 U 8.15 Flame Spread Fuel Contributed Smoke Developed Fiberglas 25 C Pipe Insulation System 20 5 40 Note This rating is for the pipe insulation plus an unlimited number of fittings in a piping system if materials and application conform to those recommended application recommendations The self sealing lap feature on Fiberglas 25 P Pipe Insulation sections makes installation on straight runs of pipe a simple procedure The only precaution needed is to keep all contact adhesive surfaces clean and to rub hard all longitudinal and circumferential seams The end joints are sealed with a factory furnished joint sealing strip with pressure sealing adhesive Fittings are fabricated from mitered segments of Fiberglas Heavy Density pipe insulation or commercially available molded insulation fitting covers Fitting insulation is coated with a skim coat of 30 insulating cement to smooth out the insulation and permitted to dry CF Fitting Mastic Type C is then applied over Fiberglas forcing Cloth coated with another coating of C Fitting Mastic Type C. If painting is required no sizing is necessary but to main- tain the noncombustible rating of the system only Glidden acrylic latex paint No. 5370 is approved for use specification compliance 1-558a Form D Type III Class 12 Recommended Thickness Selection of insulation thicknesses for any specific application should take into consideration the fol lowing important criteria 1. Cost of insulation applied 2. Cost of heat energy 3. Cost of capital 4. Cost of depreciation and insulation 5 Capital investment in heat production equipment 6. Temperature differential 7. Size of the pipe or surface 8. Conductivity of insulation for cold piping proper thickness is required for efficient operation and to prevent condensation on the insulation surface Specifically 1. Designed thickness should be specified to result in a surface temperature above the Point temperature of the surrounding air Generally this is equal or greater than the economical thickness despite the relatively higher cost of cold Btu's 2. Insulation thickness should be based on ambient air conditions and corresponding permissible temperature differences Ambient Air Condition 90 F at 90 R.H. 90 F at 80 R.H. Permissible temp drap between ambient air and insulation surface 3F 7F 3. Piping operating down to freezing temperature or cycling hot and cold temperatures should be insulated for maximum performance during the coolest part of the cold cycle Pipe Suface Temperature 35 F Condition Ice Water 90 RELATIVE HUMIDITY Thickness Recommended Recommended Thickness Gain Heat Gain Btu 80 RELATIVE HUMIDITY Recommended Thickness -Ambient Still Air At 90F PIPE SIZES # 111 111 111 111 112 112 112 112 523 523 523 111 112 111122 523 523 552233 # 111 111 111 112 112 112 112 523 523 523 copper tubing nominal size w%] 114 114 114 s 114 114 114 |6 112 113 3 3 3 22 22 22 22 22 2 3 12 12 12 2 2 113 || |1 | 12 2 112 113 3 3 3 22 22 22 22 22 2 3 12 2 2 2 38 38 7314121325 7314121325 731441221325 731441221325 731441221325 731441221325 731441221325 731441221325 731441221325 731441221325 731441221325 731441221325 731441221325 54 58 85 19.5 38 | 73174314121213123525 73142135 731421325 731421325 7314121325 |58 | 19.5 38 38 7314121325 7314121325 731441221325 731441221325 731441221325 731441221325 731441221325 731441221325 731441221325 731441221325 731441221325 731441221325 731441221325 54 58 85 19.5 i , Thickness Recom endedRecommended Thickness Gain Heat Gain Btu 44111111111 44111111111 4111 4111 44111111111 4111 44111111111 44111111111 44111111111 44111111111 44111111111 44111111111 44111111111 44111111111 44111111111 4111 4111 41 1 1 41 1 1 41 1 1 41 1 1 41 1 1 44111111111 44111111111 4111 411111 411111 44111111111 44111111111 44111111111 44111111111 44111111111 44111111111 44111111111 44111111111 44111111111 4111 4111 411111 9:46 9:46 9:46 99::4466 9:46 9:46 9:46 9:46 9:46 9:46 24 24 22 22 26 26 33 33 9:46 9:46 9:46 24 24 22 22 22 26 33 33 33 437 437 437 437 33 437 437 43 33 62 88 111 140 152 || 43 33 62 88 111 140 152 Minimum thickness available above 12 IPS is " above 24 IPS is 14 Fiberglas 25 C Pipe Insulations installed by this unique method elimi nates the need for stapling bands and lap adhesives The contact type adhesive offers a positive vapor seal at all joints and speeds applica tion It's as easy as 1,2,3 1 start to peel the release paper off the . vapor barrier 2 apply to pipe and peel off the balance 3 place the lap in place at the center and pressing hard work out toward either end Rub with the blunt edge of a knife End joints are sealed with a " wide butt strip of the same Sealing vapor barried material *! taor) q ae ater, Piping Insulations . ale O Flexible Tubing and fre Sheet Insulation Available white or black sheet or tube a flexible foamed plastic insulation for hot or cold copper tubing and iron pipe LN operating at temperatures from -50 to 220 aes rte ~~ call wa Wt r Stes 4 O Flexible Tubing is recommended for use on cooling and heating water lines chilled drinking water and refrigerent suction lines The flexible feature of this resilient insulation allows it to conform to gradual bends Available unslit to slide over tubing or pipes before they are installed or slit to apply over piping already in place O Flexible Tubing Insulation is made from an expanded elastomeric plastic blend Millions of tiny cells each filled with an inert gas make this product an extremely efficient insulator is resilient and soft returning to full thickness after being compressed The inside surface is powdered to make it easy to slip over the pipe or tubing benefits Efficient low thermal conductivity of 0.26 at 70 mean temperature assures minimum heat loss or maximum performance of equip ment | Fast Application in two forms slit and unslit Means faster application No band- ing required The unslit material slips over gradual bends with ease , Built VaVpaopror Barrier the clclosed osed cell cell stsrturucc-ture eliminates the need for a separate vapor barrier and protects against moisture conden sation on cold lines Uniform Thickness quality control as- sures constant diameters and thicknesses pro viding a snug fit on the pipe and smooth butt joints Broad 220 temperature range from -50 to possible insulation lines makes possible insulation of most lines commonly used in commercial heating and air conditioning Flexible and designed for exceptional ease of handling It is so flexible it can be tied in knots resilient it springs back to original shape when untied Resists mechanical abuse Softer for winter flexibility and ease of application ' 1 og, Spamgla gla Se FOSMURAL UHL S EDP + PAL ARR staysgS sab kid BACH mage Mg i nt Ko ^' a on oer performance characteristics 2013 EXEEEZ IE 2013 be i 3 ES seers eee ..6.65 ..6.65 density lbs./cu.ft ..6.65 water vapor transmission ere eee .less than 0.05 &E perm in ^' = thermal conductivity sq.ft. s limit maximum 4 maximum temperature limit 70 mean temperature continuous use ...... se -50 to 220 eEdS i Self extinguishing 90 mean temperature Pq fire rating per ASTM 3 absorption BA ozone resistance ..Good ..Good = FY g : ee water absorption % by volume low level SB] ASTM D1056 .0.5 fA odor Extremely f = 5 5 Ps ES Recommended Thicknesses O Flexible Tubing Thickness for Line Temperature MILD NORMAL NORMAL SEVERE DESIGN CONDITIONS PIPE SIZE Prevention of maximum severity of 80 F and indoor R.H. Typical of | these conditions condensation indoor piping under most air conditioned spaces and arid " 34" thru 2 IP Over " IPS thru 4 LPS climates Prevention of condensation indoor piping under motimum severity of 85 and 70 R.H. Research and Over field experience suggest indoor conditions anywhere in the U.S. seldom exceed this degree of severity J... J... 10 thru 2 IPS Over " PS thru " IPS Prevention of condensation on Indoor piping under a maximum severity of 90 F and % R.H. Typical of these conditions indoor areas where excessive moisture is introduced or poorly ventilated confined areas where the temperature may be depressed below ambient a } % 10 thru " IPS 50 F Nom Nom " % " Nam Nom Hoa Hoa " 32 F OF Nom N Nam [Sein Nam Ngo Nom Nom Nom Nam Ngo Nom Nom Nom " % Nom ... Nom. 34 Available --/-- Request Consideration for condensation only Heat gain of coolant not considered because O Flexible Tubing Insulation is used primarily on short outs flexible tubing sizes " iron pipe sizes IPS 1/4 to 6 copper tubing CT O 3 O.D. Wall thickness nominal ** Inside Diameters " to 3 Up to 2 IPS and CT only Length of Sections Standard Carton 6 Feet Made to order Any length Coil lengths up to 150 ft flexible sheet sizes . ) Standard size x 72 and 30 x 72 depending on thickness Sheet thickness continuous rolls x 30 150 x 30 x 74 x 30 x 150 x 30 ^ 54 ...4x 30 x 120 specification compliance 1-573b 15280 GSA application Insulation can be slipped over pipe or tubing before installation or snapped over piping already connected All joints are sealed with O 500 adhesive Paint both edges of slit as porous surfaces of tubing require it for firm bond This tenacious adhesive forms a F strong resilient bond which grows stronger with age It is water and oil resistant Flexible tubing insulation can be slipped right over copper tube fittings Cast bronze fittings or fittings on iron pipe can be sleeved 5 with a larger diamofeintsuleatiron nested over the covering on the pipe and adhered with C 500 adhesive C Flexible Tubing insulation should be protected from the weather on lines running out doors with Benjamin Foster's BF 57-68 coustic VIAC 550 or Chlorinated Rubber Paint or Presstite 762 protective coating Pipe Insulation Fiberglas 25 H Pipe Insulation A noncombustible pipe insulation system for hot service piping operating at temperatures up to 450 Recommended for use on all heated piping operating at temperatures up to 450 where a complete noncombus tible insulation system is desired for commercial and institutional buildings schools hospitals and places of public assembly Also recommended for processing lines where fire safety is a paramount criterion Fiberglas 25 P Pipe Insulation System is composed of Fiberglas Heavy Density Sectional Pipe Insulation jacketed with a white sized glass cloth jacket Longitudinal jacket flaps are secured with door staples End joints are closed with a glass cloth tape stapled firmly in place t 3 7 = i rie E . i fire safety a complete insulation system with a UL rating including pipe fittings and mastic when installed in accordance with recommended procedures ready for painting factory sized glass cloth jacket and matching tape and mastic system do not require field sizing If desired painting may be omitted See Application Recommendations sD ares Fiberglas Reg U.S. Pat and 25 are per trademarks of Corning Fiberglas Corporation damage resistant the extra heavy density pipe insulation and extra tough woven glass cloth jacket resists damage on exposed lines thermal effi lower operating cost the exceptional ciency of Fiberglas Heavy Density pipe insulation contributes to lower operating cost of heating equipment and piping xy ts Vpiet, a, ee Re at Ra Wavy ry SOIREcoale wed, oes = performance characteristics ore l l 3 Insulation dimensional stability will not warp shrink rot or decompose specific heat 0.20 Btu F. vermin and rodent resistance provides no sustenance temperature limitation heated lines to 450F alkalinity ph stress corrossion will not cause stress corrossion cracking of stainless steel Jacket permanence mildew resistant Will not rot or shrink Vermin and rodent proof burst strength exceptional glass strength exceeds that of canvas sized Cloth 300 psi 8 oz Canvas 211 psi thermal conductivity ne den athn in 40 4 F at ft ; sq 30 ; en | 20 BTU ; id 10 } 1 l a af ite m4 0 75 100 200 MEAN TEMP F roney tare 300 350 : e Pe aoe h ane Page ip fire hazard classification Maximum Fire Hazard Classification for building materials and insulations as noncombustible has been established as follows Flame Spread Fuel Contributed Smoke Developed . Acceptable 25 50 50 Fiberglas 25 H Insulation System including fittings is below the maximum allowable This is your assurance that you can specify and use Fiberglas 25 P Pipe Insulation System without the danger of contributing to the spread of fire or that combustion will liberate excessive smoke The system has been designed to meet the stringent fire safety requirements of the GSA and Corps of Engineers Underwriters Laboratories Pipe & Equipment Coverings R5583 40 U 8.15 Flame Spread Fuel Contributed Smoke Developed Fiberglas 25 P Pipe Insulation System 20 25 15 10 20 35 Note This rating is for the pipe insulation plus an unlimited number of fittings in a piping system when CF Fitting Mastic Type H is used Note This rating is for the pipe insulation plus fittings when the system is limited to % of fittings and BF 30-36 is used finish The factory sized white finish eliminates the necessity of sizing the jacket before painting and the neat white surface may be left unpainted if desired Fitting finish is also compatible with the insulation jacket If painting is required Glidden acrylic latex paint No. 5370 is approved for use application recommendations Fiberglas 25 H.P Insulation System is installed on the pipe by stapling the longitudinal jacket flap securely with flaredoor staples on 2 centers End joints are closed by wrapping with furnished sized glass cloth tape stapled in place Fittings are insulated with Fiberglas molded or seg mental Insulation and wrapped with Fiberglas Reinforcing Cloth Type H. The wrapping is subsequently coated with O.CF Fitting Mastic Type H or Benjamin Foster 30-36 federal specification compliance Fiberglas 25 P Pipe Insulation System meets the requirements of Federal Specifications 1-553a Form D Type III Class 12 ASTM C547-67 ~~ recommend thickness selection of an insulation thickness for any specific applica- tion should take into consideration the following important criteria Cost of insulation applied 2. Cost of heat energy 3. Cost of capital 4. Cost of depreciation and insulation 5. Capital investment in heat production equipment 6. Temperature differential 7. Size of the pipe surface 8. Conductivity of insulation The thicknesses shown in the table below are based on the optimum balance of these consideration for selecting an insulation thickness for performance and economy recommended thickness piping to 450F 80F Ambient still air Pipe Temp Temp Diff IPS 31 1 - 1... 1 2233445 2 2233445 3 2233445 4 2233445 6 789 789 789 10 11 12 14 16 18 20 24 30 200 120 RT HL 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 19 22 25 20 21 24 28 32 30 39 38 50 57 62 68 80 59 64 80 92 93 101 110 131 132 ST 105 107 107 95 93 94 94 94 95 95 95 95 97 96 96 97 91 91 96 92 92 92 92 93 92 RT 1 1 1 l 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 22222 22222 22222 22222 22222 300 220 HL 34 29 30 37 39 45 50 50 56 57 72 70 85 90 100 110 110 120 149 171 133 148 162 194 257 ST 125 106 102 108 106 106 101 101 103 101 104 100 101 100 101 101 101 101 107 110 97 97 97 98 98 RT 1 1 1 1 1 1 1 1 1 1 1 1 1 12 2222 2222 2222 2222 2 2 2 2 2 2 2 400 320 HL 39 46 48 62 63 73 74 76 94 94 118 114 128 142 125 138 146 168 171 190 181 204 222 266 323 ST 115 122 117 125 121 122 113 110 111 112 115 115 115 110 107 106 106 106 106 108 103 103 103 104 103 RT 1 1 1 1 1 1 1 1 1 1 1 1 2 2 222n 222n 222n 222n 2 2 2 2 2 2 2 450 370 HL 47 56 60 75 62 70 88 93 114 114 148 140 125 136 154 174 180 194 209 199 223 248 271 320 361 recommended thickness heat loss lineal foot surface temperature F heat gain ST 123 131 129 135 112 113 121 116 118 118 121 121 110 108 111 111 111 111 112 107 108 108 108 109 105 ae ee hae Gemma. yet th Raa POs ln A LIR ROY Ry Maat Rh ERR emi ay w h tarya ee ? Ab eee t. wdur Sa Samidee, a eee aiINR SdTele fay J Be prose Fate ns ie ge eo AB EY Ere Industrial Insulation 700 Series a highly versatile group of Fiberglas insulating boards designed to insulate ductwork and equipment operating at temperatures up to 450F description The 700 Series boards have been designed primarily to insulate heating and air conditioning ducts ovens tanks boilers hot water generators and other hot equipment Fiberglas * 700 Series Industrial Insulations are made of inorganic glass fibers formed into semi to rigid rectangular boards of varying densities The series consists of Type 700 701 702 703 704 and 705. Each type 700 low cost flexible material suitable for insulating fabricated metal panels and for packing into irregular spaces type has specific thermal and physical characteristics factory which makes it suitable for the uses described 703 704 and 705 are available with a variety of Type applied barrier facings to prevent condensation type 701 lightweight resilient insulation in board form used on vessels having irregular surfaces where on cold surfaces and to provide a neat finished appearance Fire Retardant Facings are available the exterior finish is supported by welded studs pins or other mechanical attachments type 704 rigid board recommended for use on heating and air conditioning ductwork in exposed areas Radse acteristics A type 702 More rigid than 701 and is recommended for use on equipment and ductwork subject to minmum where sharp true corners and smooth surfaces are desired maintenance and construction abuse Ar type 705 rigid board with very high strength char- type 703 A semi board recommended for use on acteristics for use on chillers hot and cold equipment heating and air conditioning ductwork where greater PES equipment vessels and air conditioning ductwork abuse resistance and good appearance is required lower operating costs the exceptional thermal efficiency of Fiberglas 700 Series Insulations lowers operating costs - end tailored - a variety of densities and facings offers a selection of products to meet specific per- formance and economic requirements continuous place performance - 700 Series resists damage maintains structural integrity and efficiency Thickness stays uniform neat finished appearance the boardlike character istics of the heavier density 703 704 and 705 products provide neat square corners The applied facings present an attractive finished appearance fire safe - Fiberglas is inherently fire safe The un- faced boards and the Aluminum Foil Faced 703. 704 and 705 have UL Flame Spread ratings of less than 25 T.M Reg O F. Corp. Be aaoe i { ee Es Ef ped = al BA = a > 2 a, 3 Eire NCE performance characteristics sound absorption coefficients 2 thick 6 mounting TYPE 701 702 703 704 705 125 .34 .28 .32 .27 .48 250 .70 .77 .74 .79 .82 500 .96 .96 .97 .98 .97 1000 .97 .98 .98 .99 .99 2000 .86 .87 .87 .88 .90 4000 .83 .87 .85 .86 .86 size and density Type Density pcf Thickness in increments Compressive Strength psf at % deformation Standard Size Therm Cond (@ 75F Mean Temp 700 701 702 703 704 705 1.08 1.58 2.25 3.00 4.20 6.00 -4 " -4 -3 -2 -2 -2 3t 4.5+ 9.5f 100 200 350 For special applications boards up to 48 x 96 are available 24 x 48 0.260 0.242 0.235 0.230 0.230 0.220 tAfter compression packaged thermal conductivity .50 in ft .30 sq hr hr BTU .20 BTU 10 700 ~ 701 701 702 703 4 > Be a 705 705 i I 0 75 100 200 MEAN TEMP F 300 350 moisture absorption ... bacteria and fungus resistance odor Lo. Lee humidity and temperature effect corrosion to . bo ee Lee ee ee, . less than 0.2 by volume ..does ..does not breed nor promote woes .. odorless cycling conditions will not cause spalling or crumbling does not accelerate corrosion of copper steel or aluminum facings Type 703 704 and 705 are also available factory applied vapor barrier facings FF - .0025 aluminum foil UL Rated FRX - reinforced kraft SF - Duplex Laminated kraft with the following fire hazard classification unfaced faced | 700 701 702 | 703 704 705 703 704 705 flame spread fuel contributed smoke developed compared to 10-20 10-15 0-20 untreated Red Oak 15 15 0 as 100 15-20 20-35 0 application recommendations Type 700 701 702 Lightweight unfaced flexible insulations in board form for use on vessels having irregular surfaces where the exterior is supported by welded studs or stiffeners and not by the insulation itself The products are sup- porting but are generally secured with mechanical fasteners and protected by sheet metal 705 Type 703 704 These board insulations are normally impaled on welded pins on flat surfaces They are cut in segments and banded in place on irregular surfaces Unfaced boards are normally finished with reinforced insulating cement or weatherproof mastic Faced boards with joints taped to provide a continuous vapor barrier may be left unfinished or may be canvas jacketed recommended thickness- heated equipment 80F ambient air Surface Type 701 Type 703 Type 704 Temp RT HL ST | RT HL ST RT HL ST 150 C H K I I E I R 250 C H I K I E I R K I | 350 C H I K I I E I R KK | 450 3 H 105 K I I E R RT - recommended economic thickness inches HL - heat loss Btu ft ST - surface temperature F thickness to prevent condensation cold ducts and equipment The following chart indicates the recommended thickness of Type 703 704. 705 Faced Duct Insulation for installation on cold air ducts at various temperature differences duct to air Also shown are values for heat gain and approximate maximum relative humidity allowable 8b Ow Temperature Differences 20 YASKWM YASKWM YASKWM YASKWM YASKWM YASKWM Recommanded Thickness inches K % 1 \ 1 1 2 Heat Gain Etu 51 6.4 6.1 7.1 5.7 6.3 5.4 Permissible Relative Humidity 90 87 89 % 90 89 % specification compliance 1-558a Form A Class 1 1-558a Form A Class 2 702 703 704 705 703 704 705 1-558a Form B Type 1 Class 7 Navy Bureau of Yards and Docks 16Yf Corps of Engineers 301.08 .11 thru .17 700 701 702 703 704 705 703 704 705 Type 703 G is specially produced for contracts where certification of comphance to the above Federal Specification is required Available plain or faced for use on hol or cold equipment and for air conditioning ductwork Waiver required on upper temperature limit limitations Industrial insulation 700 series plain should not be used on surfaces operating at temperatures above 450F Types 703 704 705 faced products should not be used on surfaces operating at temperatures greater than 250F except that FF may be used at a maximum thickness of 2inches up to 450F caution Corning Fiberglas Insulations are to be applied only with approved adhesives mastics and mechanical fastening devices as published in Accessory Materials List Pub No. 3430 Corning Fiberglas accepts no respon sibility or liability for the performance of materials other than those listed unless approved in writing by CF Testing Laboratories pee FIBERGLAS FFIBERGLASIBEFIRBEGRGLLASAS A FIBERGLAS Bans <4 8 he heWe rt oy ify o * Equipment Insulation are i Kaylo 10 & Kaylo 20 TAR AHA Block Insulation Ge AA beta MERE EALPRCA rigid calcium silicate insulations for all types of heated equipment operating at temperatures up to 1800F =f Kaylo 10 Block is for use on indoor or outdoor equip ment operating at temperatures up to 1200F Kaylo block is ideally suited for use on stainless steel vessels and equipment it helps inhibit stress corrosion cracking Typical applications are for boilers breeching tanks vessels Kaylo 10 Block is white in color Kaylo 20 with its high temperature limit of 1800F extends its use to include refractory wall backing for furnaces and boilers and fireproofing of equipment and vessel skirts description 59 hazare at roto Te Kaylo 10 and Kaylo 20 Block Insulations are rigid hydrous calcium silicate heat insulations reinforced with asbestos fibers They are strong efficient and are highly resistant to abrasion and moisture damage Kaylo 20 has a slightly pink color to distinguish it from Kaylo 10 benefits high thermal efficiency Kaylo 10 and Kaylo atmosphere or other sources from causing crack- ay 20 offer excellent thermal efficiency coupled with ing and possible failure of piping and equipment % ex MAPLE < mM high strength A low k of .40 for Kaylo 10 and .52 for Kaylo 20 at 200F mean temperature proves that Kaylo will provide significant savings in operating costs over the life of the equipment resistant to resists mechanical damage resistant to moisture damage unlike many other insulations Kaylo is not affected appreciably from moisture damage It regains thermal efficiency and strength after drying out Outdoor installations must be weatherproofed however for long T I tes Na oR TOR AENMRM ceOY ed te mS tame to because of hard tough reinforced structure strong breakage in shipment and handling High temperatures have little effect on strength characteristics will not cause stress corrosion cracking Kaylo will not cause stress corrosion cracking of stainless steel because Kaylo contains less than 200 ppm soluble chlorides as well as an inhibitor which prevents trace quantities of chlorides from the continuous service dimensionally stable does not shrink appreciably in service even at elevated temperatures This means less heat leakage at the joints And Kaylo will not warp or crack in service fabricates easily ordinary insulators tools are all that is required to fabricate Kaylo It cuts with a clean true edge for tighter fit at the joints Fit tings are neater faster EE rere ' eet Kaylo is a registered trademark Reg U. Pat Off of Corning Fiberglas Corp. iF 4a ae re 33 7B re con ley performance characteristics ret hee mm ae density # flexural strength = ASTM 203 ary aeBel compressive strength ASTM 165 at % ae deformation Fg 8 ='=resistance to abrasion ee ASTM 421 ae u a = dimensional stability dimensional fd ASTM 356 KAYLO 10 11 pcf approx 60 psi average 125 psi KAYLO 20 12 pcf approx 90 lb sq in 130 psi after 10 minutes 20 max after 20 minutes 45 max linear shrinkage after heating for 24 hours in muffle at 1200F eh ware iat ed EE aks thermal conductivity 09 07 07 MT KAYLO 20 Ly LY IN 05 a Z 4 / \/ KAYLO 10 01 100 300 400 500 600 Mean Temperature F 23 ee i 74 ba 4 ie economic thickness Selection of insulation thicknesses for any specific applica tion should take into consideration the following important criteria 1. Cost of insulation applied 2. Cost of heat energy 3. Cost of capital 4. Cost of depreciation plant and insu- lation 5. Capital investment in heat production equipment 6. Temperature differential 7. Size of the pipe or surface 8. Conductivity of insulation From How to Determine Economic Thickness of Insulation National Insulation Manufacturers Association economic economic thickness thickness 10 block to ambient still air 1200 ambient still air 80 F economic thickness surface temperature heat loss heat foot THICK | 1.000 1.500 2.000 2.500 } } 3.000 3.500 4.000 4.500 5.000 5.500 6.000 calculated 200 F 300 F 400 F HEAT SURF HEAT SURF HEAT SURF LOSS TEMP TEMP LOSS TEMP 500 F 600 F 700 F HEAT SURF HEAT SURF HEAT SURF LOSS TEMP LOSS TEMP TEMP 800 F HEAT SURF LOSS TEMP 900 F HEAT SURF LOSS TEMP 1000 F 1100 F HEAT SURF HEAT SURF LOSS TEMP TEMP 1200 F HEAT SURF LOSS TEMP 38 103 | 72 27 96 51 21 93 40 17 90 33 14 89 13 88 11 87 10 7342324827 734423224827 7342324827 734423224827 7342324827 734423224827 | 28 | 24 | 21 7342324827 19 7342324827 734423224827 73424827 734423224827 734423224827 124 109 147 111 | 78 127 107 145 104 | 60 117 | 83 130 107 145 100 | 49 110 68 121 87 133 109 146 97 42 105 57 115 74 125 92 136 112 148 ||; || +|t | | 95 36 102 49 110 64 119 80 129 97 139 116 150 / 93 32 91 28 7342324827 734423224827 734423224827 734423224827 734423224827 77334422332244882277 734423224827 734423224827 99 | 44 107 | 56 114 97 7342324827 39 104 50 111 734423224827 734423224827 734423224827 734423224827 734423224827 734423224827 734423224827 734423224827 734423224827 734423224827 773344223344882277 734234827 734423224827 734423224827 734423224827 734423224827 734423224827 70 123 85 132 102 142 120 153 63 118 76 127 91 136 107 145 156 734423224827 734423224827 7342324827 734423224827 734423224827 734423224827 734423224827 734423224827 734423224827 82 130 | | 75 126] 97 139]113 149] 130 189 88 134/103 143 318 152 734423224827 734423224827 734423224827 734423224827 7342324827 69 122] 81 130 94 138 | 109 146 Kaylo 20 Block to 1800 ambient still air 80 F t Operating Temp F 1300 1400 | 1500 1600 {| 1700 1800 ET 7 8 8 81 9 9 Power HL = Ill 117 123 129 135 141 ST | ET 136 | 6 139 | 6 142 | 7 145 7 | 148 151 7 % Process HL ST 135 148 143 8 152 155 158 159 165 163 166 compliance specisfpeicifcicaattioin on compliance 1-523c Insulation Block Pipe Covering Thermal Cal cium Silicate for temperatures up to 1200 Type 1 1-2819E Insulation Block TherThermal mal Class 1 a 2 n and d . ASTM C533-67 1-24244 ships Insulating Materials Thermal with Special Corrosion and Chloride Requirements Kaylo only . Type 3A 3B , sizes thickness thickness 2 4 width " " " 1 , 12 2 and 18 3 length to 36 3 " " " 3 and form - Block beveled lags For pipe sizes greater than those for which Kaylo 10 and Kaylo 20 Pipe Insulation sizes are available Kaylo 10 and Kaylo 20 beveled lags may be used to insulate piping Lags beveled to fit pipes from 18 to 72 in diameter are available in thickness of 1 23 Lags are 36 long and 3 wide application recommendations Kaylo 10 and Kaylo 20 Block Insulations are her in place by mechanically fastening with bands welded rods or studs The insulation may be finished with a trowel coat of insulating cement canvassed and painted Outdoor installations require weatherproofing with mastics or metal jacketing i ee Equipment Insulation Fiberglas 25 ME Ro Dr = te H Equipment os = BS Insulation System a= aee fei oe 4 a a ner ee CGE a EEA RF a Eg Re AMEE RS NIE ATONE IRE ENOAT abaN se tySe Mw a A noncombustible rigid board insulation system 0, EER eS for hot service ducts and equipment operating 9, at temperatures up to 450 teePOT Recommended for use on all hot mechanical equipment and ductwork operating up to 450 where the ultimate in noncombustibility is desired A Fiberglas 25 H.E Equipment Insulation System for heated surface service consists of a rigid insulation board of glass fibers faced with a noncombustible sized Fiber glas cloth Other components of the system include a noncombustible pressure sealing joint tape and finished metal fastener caps attached to welded pin anchors _ benefits et mena re - the fire safety complete insulation system with UL damage resistant tough finely woven glass oy rating on board facing joint tape fastening de cloth facing resists damage and the rigid insula OREO vice tion board absorbs most impact blows without damage LIE ready for painting sized white glass cloth facing matching tape and fastener caps do not require field sizing prior to painting If painting is required use recommended paint - lower operating costt he uniform factory con troiled board thickness assures constant thermal efficiency performance Fiberglas Reg U.S. Pat Off and 25 are trademarks of Corning Fiberglas Corporation ee _ _ en 1 _ _ _ ee ond performance characteristics * * . ~ we - eee ce ee ee Oo < ewt oo Ler Ty JA or dimensional stability will not warp shrink rot or decompose vermin and rodent resistant provides no sustenance flame hazard classification Flame Spread 25 Flame Contributed 10 Smoke Developed 50 temperature limitations recommended for heated surfaces when temperatures do not exceed 450 jacket burst strength 300 psi thermal conductivity 50 18 40 F ft sq BTU 20 10 5 ! i $ 75 100 200 MEAN TEMP F [ 300 35C - 3 q H q1 cal 3 3 . . . "> . *. A . sizes Width 24 Length 48 Thickness " 12 fire hazard classification Maximum Fire Hazard classification for building materials and insulation as noncombustible has been established as follows Flame Spread Fuel Contributed Smoke Developed Acceptable 25 50 50 Fiberglas 25 H Insulation System including fittings per forms below the maximum allowable This is your assur ance that you can specify and use this system without the danger of contributing to the spread of fire or that com bustion will liberate excessive smoke The system has been designed to meet the stringent fire safety requirements of GSA and Corps of Engineers Underwriters Laboratories Pipe & Equipment Coverings R5583 40 U 8.15 Flame Spread Fuel Contributed Smoke Developed Fiberglas 25 E Insulation System 25 10 50 Note This rating is for the composite product and includes the use of CF Type H Joint Sealing Tape of materials and application conform to those recommended specification compliance meets the stringent fire safety requirements of GSA and Corps of Engineers 1-558a Form A Class 1 & 2 ASTM C392-63 Meets NFPA 90A fire hazard requirements application recommendations Fiberglas 25 E Equipment Insulation System is installed by impaling the insulation boards on welded pins spaced 3 in from each corner of the board with intermediate pins on no greater than 21 centers After boards are impaled the welded pins are cut to extend " beyond the face of the board and a locking cap is pushed onto the pin All insulation raw edges and butt joints are to be sealed with O.CF Joint Sealing Tape Type H. Tape is a pressure seating type requiring no separate adhesive Pressurize tape by rubbing hard with a plastic sealing tool Ductwork els and other sharp radius bends require prescoring of the insulation board to conform to the curved surface ; If painting is required no sizing is necessary but to main tain the noncombustibility of the system only Glidden acrylic latex paint No. 5370 is approved for use recommended thickness equipment 80F ambient still air Operating temp RT HL ST 150F 1 250F 1% 350F 2 450F 2 15 89 29 $8 39 104 61 li? RT - recommended economic thickness inches HL heat loss Btu ST - surface temperature F Kaylo 10 & Kaylo 20 Pipe Insulations rigid hydrous calcium silicate pipe insulations for heated piping up to 1800F 10 is recommended for use on heated piping oapyelroating up to 1200F and Kaylo 20 extends the temperature range to 1800F These thoroughly tested insulations have the physical properties most desirable for efficient durable work for indoor and outdoor power and process piping A variety of jackets are available for surface finish and weatherproofing Kaylo 10` & Kaylo 20 pipe insulations are rigid hydrous calcium silicate heat insulations for use on all heated to indoors and out These products piping up from a are precision molded in sections or segments chemically reacted material A small amount of asbes tos fiber is added to improve mechanical strength Kaylo 10 is white Kaylo 20 has a slight pinkish color to distinguish it from Kaylo 10 peo Pos b oy TA benefits lower operating Kayl Kayo lo Insulations have exceptional thermal efficiency The low k factor of .40 at 200 mean temperature means lower operating cost better temperature control for process operations unaffected by moisture Kaylo can be completely saturated in water without appreciable loss of strength and regains its strength and thermal value after dry- ing out rugged - Kaylo Pipe Insulations are strong and rigid to resist mechanical abuse in shipping handling and in service clean neat installation Kaylo cuts cleanly leaving a sharp square edge for neater appearance on fittings Rigid manufacturing tolerances assure uniform smooth unbroken joints versatile - Kaylo's extended temperature range cov All ers a broad number of uses with one material heated piping requirements to 1800F and in sizes from ... to 30 IPS can be met with Kaylo and Kaylo 20 will not cause stress corrosion cracking will not cause stress corrosion cracking of steel because Kaylo contains an inhibitor less than 200 ppm soluble chlorides - Kaylo stainless and has variety of jackets A variety of applied jackets allows a selection of product for indoor finished or for weatherproofing insulation on out- appearance doar lines nesting sizes Kaylo Pipe Insulations are tured to Simplified Dimensional Standards nesting sizes for double layer applications manufac to permit Kaylo is a registered trademark Reg U.S. Pat Off of Owens Corning Fiberglas Corp. on se ae So performance E characteristics 27S Rates. paras ET acta ce gnmatarts oe Pe wehy a4 Kaylo 10 Kaylo 20 thermal conductivity density approx flexural strength ASTM 446 11 lb. pcf 12 lb. pcf 75 lbs./sq lbs./sq 75 lbs./sq lbs./sq compression strength ASTM 165 at % deformation 125 psi 110 psi resistance to abrasion Conventional tumbling loss in weight before heating ASTM 421 corrosion resistance dimensional stability linear shrinkage after heating for 24 hours in muffle ASTM 356 after 10 minutes 20 max after 20 minutes 45 max does not cause or acceler ate corrosion of steel aluminum or stainless steel Ezin Ft Sq Blufth Ms Kaylo 15 % length loss 1.4 at 1200F 2.0 at 1800F 130 * fo 3k 500 OM 130 JUC Mean Temperature 8b -- -- sizes thicknlayee r Ks ays lo Pipe Insulation is available in single or double layer thicknesses from " to " depending upon pipe size Kaylo Tube Insulation is available in single layer thick- nesses of " and 1 pipe sizes Kaylo Pipe Insulation is available to fit nominal pipe sizes from to 39 in diameter Kaylo Tube Insulation will fit nominal copper tubing sizes from to " in diameter forms - Kaylo Pipe Insulation is available in sectional or multisegmental form depending upon pipe size All insulation is furnished in 3 ft sections jackets canvas Standard canvas & 8 oz canvas jacket are available for all types sizes and thicknesses of Kaylo Pipe and Tube Insulation at an additional charge These jackets are factory applied on Sectional Pipe and Tube Insulation On Multisegmental forms they are furnished but not adhered Bands are available for use with this product at slight additional charge and will be furnished on request application recommendations outdoor lines Kaylo Pipe Insulations are mechanically fastened by wiring in place using 16 gauge wire on centers and subsequently covered with a weatherproof jacket of metal or 45 lb. roofing felt See Application Specifications for com- plete details indoor lines - Kaylo for indoor piping work is furnished with a applied canvas jacket and held in place with bands or wire The jacket has overlapping joint flaps that are smoothly pasted in place Canvas should be sized to provide a base for painting fittings Fitting are insulated with mitered segments of Kaylo wired in place and finished with a " layer of insulating cement Flanges and valves are insulated with oversized pipe insulation They are finished off with canvas pasted in place for indoor lines or reinforced waterproof mastic for outdoor lines Kaylo Klad Kaylo is also available with an embossed alu minum jacket .016 thick or .010 thick stainless steel jacket These jackets provide greater resistance to mechanical dam age and present a neat finished appearance to pipe lines The longitudinal seam has a locking joint Butt sealing strips with integral mastic and protective asbestos cover are furnished for sealing end joints specification compliance 1-523c Insulation Block and Pipe Covering Thermal Calcium Silicate for Temperatures up to 1200F Type II Class A through F. 1-2781D Int Amend 1 - Insulation Pipe Covering Thermal Grade , Class b Grade II Class d Grade III Class ~ Type I and II 1-24244 -Insulation Materials Thermal with Spe cial Corrosion and Chloride Requirements Type 1A 1C 1D 1E ASTM C533-67 For tables on economic thickness refer to Corning Fiberglas Corporation Pub No. 4350-8 page 5.3 in Mechanical Insulation Systems manual Pub No. 2600 Equipment Insulation } Fiberglas Fiberglas 25 E Equipment Insulation System Fens PoaN he Be WR TE AE oR Sat a AW KEN A noncombustible rigid board insulation and vapor barrier system for cold and dual- if iN temperature service ducts and equipment operating at temperatures down 120 F ere as a dhl | qt c~ description Recommended for use on all cold or temperature A Fiberglas 25 C Equipment Insulation System for : service rectangular ducts and cooling equipment cold temperature service consists of a rigid board of i where the ultimate in noncombustibility is desired glass fibers faced with noncombustible vapor barrier Boards are impaled over welded pins and held in place facing The facing is a laminate of vapor tight alumi- with white fastener caps vapor sealed with mastic num foil and sized glass cloth Joints are sealed with a noncombustible vapor barrier pressure sensi tive adhesive tape to form a complete vapor tight system i r Seen _ errr ates |soagsbeftct o4y E> 3 ; 7 :. a y ^', 3 ; bt fire safety only complete insulation system sulation board is resilient thereby absorbing im 7 3 f.: im with UL rating on board vapor barrier joint tape pact and resisting damage _ it mastic and fastening device lower operating cost uniform factory con- z Roy i ready for painting- sized glass cloth fac- trolled board thickness assures constant thermal : e ing matching tape and fastener caps do not re- efficiency performance Ps quire p3 field sizing They may be left unpainted if : desired no condensation drippage applied : +, glass cloth and foil vapor barrier and the taping a make vapor ir Gb - z damage resistant tough finely woven glass system the system tight to resist vapor 7 i f cloth facing resists damage and the semi in- penetration Wess fiWaclmets Reg Corning fl fl ~ Fiberglas U.S. Pat and 25 are trademarks of Corning Fiberglas Corporation I I eet es me some ve cre _ aeeene wg we _ saree performance characteristics = 0-07" Rone mee ae dimensional stability will not warp shrink rot or decompose vermin and rodent resistant provides no sustenance flame hazard classification thermal conductivity 50 Flame Spread 20 Flame Contributed 10 Smoke Developed 35 temperature limitations recommended for heated surfaces when temperatures do not exceed 450 or fall below 35 vapor transmission rate .05 perms F 40 sq 30 Ihr1 Ihr1 .20 BTU 2 _ } | + i 75 300 a 3 - 350 an . ne fe cae ae! e 4 7 oy sizes Width 24 Length 48 Thickness " 12 " fire hazard classification Maximum Fire Hazard Classification for buidling materials and insulation as noncombustible has been established as follows Flame Spread Fuel Contributed Acceptable 25 50 application recommendations The Fiberglas 25 C Insulation System is installed by impaling the insulation boards on welded pins spaced 3 in from each corner of the board with intermediate pins of no greater than 21 centers After boards are impaled the welded pins are cut to ...beyond the face of the board A locking pushed onto the pin after coating with OC Fitting Type C to provide a vapor seal extend cap is Mastic Ca Smoke Developed 50 All insulation edges and butt joints are to be sealed with ee.) a Fiberglas 25 C Insulation System including joint sealing O.CF Type C Joint Sealing Tape.Tape is a pressure sealing treatment is considerably below the maximum allowable type requiring no separate adhesive Pressurize tape by This is your assurance that you can specify and use this rubbing hard with a nylon sealing tool system without the danger of contributing to the spread of fire or that combustion will liberate excessive quantities of Ductwork els and other sharp radius bends require pre- smoke The system has been designed to meet the strin- scoring of the insulation board to conform to the curved gent fire safety requirements of GSA and Corps of surface Engineers Underwriters Laboratories Pipe & Equipment Coverings R5583 40 U 8.15 If painting is required no sizing is necessary but to maintain the noncombustibility of the system only Glidden acrylic latex paint No. 5370 is to be used C Flame Spread Fuel Contributed Smoke Developed Fiberglas 25 Insulation Systems 20 10 35 NOTE This rating is for the composite product and includes the use of CF Type C Joint Sealing Tape for sealing joints specification compliance Meets the stringent fire safety requirements of GSA and Corps of Engineers 1-558a Form A Class 1 & 2 Meets NFPA 90 A Fire Hazard Classification thickness to prevent condensation cold ducts and equipment The following chart indicates the recommended thickness for installation on cold air ducts at various temperature differences duct to air Also shown are values for heat gain and approximate maximum relative humidity allowable Temparature Differences 20 25 30 35 40 45 50 Recommended Thickness inches % 1 ' 1 1 2 Heat Gain Btu 5.1 6.4 6.1 7.1 5.7 6.3 5.4 Permissible Relative Humidity 90 87 89 88 90 89 90 2 g a Equipment Insulation 1) 8 a ME IR ACE a lightweight highly efficient rigid insulation for service temperatures up to 850F FiberglaSs Board Insulation is designed for use on boilers breechings ducts chimney liners and other heated equipment operating at temperatures up to 850 F. It is designed for use in applications where an outside facing of steel sheet or metal mesh with or without finishing cement is provided Intermediate Service Insulation S is a lightweight insulation composed of Fiberglas fibers bonded together in semi boardlike form with a special high temperature binder benefits lowers operating costs -Fiberglas Intermediate Serv- ice Board is an extremely efficient thermal insulation S Board Insulation means easier handling and the larger size pieces up to 4 x 4 speed installation A low k factor of .30 at 200 F mean temperature means lower fuel costs due to less heat more and reduce the number of joints to leak heat Larger sizes are possible because of unusual structural in- comfortable working conditions in equipment rooms tegrity The insulation will not crumble or break cuts This superior thermal efficienciys attained because of finer fiber construction and the complete absence of cleanly for good tight joints conforms readily to irregu- larities and curved surfaces and returns to full thick- pees shot or unfiberized material Heat flow tests on a 600 F power plant duct insulated partially with S insulation ness if compressed ote and with a 8 pcf mineral wool insulation showed that I.S board had superior heat flow characteristics over continuous place performance- Fiberglas Inter mediate Service Board will not stump or deteriorate an month period of continuous service in severe service conditions The insulation easily E ah passed the rugged Navy Test 1-15475C Ships fower cost installation -the lightweight feature of Paragraph 4.5.3 which requires vibration at 12 cps through an arc of .015 for 100 hours at 750F with out setting TT Trade C Fiberglas Corp. PE , &4 moons performance characteristics == eee 2 sizes 2 x 2 2 x 4 4 x 4 conductivity 50 = thicknesses 1 to 4 in increments moisture absorption less than 0.2 by weight i x Ea specific heat 0.20 Btu F = . 9 50 = 5 2 10 Lf ie a ie a : Bs ef a 100 200 150 400 500 a = Mean Temperature F. ES a heat transfer data thickness in inches 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 450 F 500 F operating temperature ambient still air 80 F 550 F 600 F 650 F 700 F 750 F 800 F 850 F heat loss surf temp heat loss 61 |] 117 73 49 | 110 59 41 105 50 35 102 | 43 31 99 33 28 97 34 25 95 | 222222 23 94 | 222222 21 222222 19 | 222222 18 222222 17 90 20 surf temp heat loss surf temp heat loss surf | heat tenip loss surf | heat temp loss surf heatheat temp | loss surf heat temp surf temp heat loss surf temp 125 88 133 | 103 | 143 | 121 | 154 } 140 f 116 71 123 84 | 131 93 | 140 | 113 | 149 | 131 | 160 | 149 110 59 116 70 | 123 82 | 130 95 138 | 110 | 147 | 125 | 155 |} 143 106 51 111 60 | 117 71 | 123 82 | 130 94 | 133 | 108 | 146 | 123 | 155 103 45 | 107 53 112 62 | 118 72 | 124 83 | 130 95 | 138 | 108 | 146 101 40 104 47 | 109 55 |] 114 64 |. 119 74 | 125 84 | 131 96 | 138 99 36 | 102 43 1 106 50 | 110 58 | 115 66 | 121 76 | 126 85 1 133 97 33 100 39 1 104 45 | 108 53 | 112 61 | 117 69 | 122 79 | 123 96 30 98 35 | 102 42 | 105 48 | 109 55 | 114 63 | 119 72 | 124 94 28 97 33 ; 100 39 | 103 45 | 107 51 | 111 59 | 116 67 | 121 93 } 25 96 31 99 36 | 102 41 | 105 48 | 109 54 | 113 62 | 118 92 24 95 29 97 33 | 100 33 | 104 45 | 107 51 [ 111 58 | 115 limitations $ Board must be applied flush against the hot surface with an exterior finish of sheet metal mesh with or without a cement coating whenever it is exposed to temperatures in excess of 350 F. There will be no rapid decomposition of the product after inserting a 1300F probe into the insulation for 20 minutes with the hot surface at 850F when the product is applied as noted above application recommendations Fiberglas Intermediate Service Insulation is installed on flat and curved surfaces by attaching with welded pins or studs and finishing with sheet metal or metal mesh and insulating cement canvassed and painted Pins with speed washers or studs and nuts are installed on a maximum spacing of 18 and not farther than 6 from the edge of the insulation The insula tion is normally impaled over the pins or studs and the enclos- ing sheet or metal metal fasteners Joints of the sheet metal finish are offset from the joints of the insulation Double application is recommended for tem perature over 600 F. DEUTS DEUTS DEUTS federal specification compliance - 1-15475C Ships except for fusing temperature 1-558a Insulation Blocks Boards Blankets Felts Sleeving Pipe and Tube Covering and Pipe Fitting Covering Thermal Mineral Fiber Industrial Type Form A. Class 3 waiver needed on compression strength i3 J RS ny rRTAMANatustild Wrst retiF re ; 53 UESsa nesta itt 10 ~ obss ESSpaenpaSteENON WSS ee Bs \\ AK UNS ft ii agentea Can ye UAT w Equipment Insulation Spe ee an efficient high temperature insulating blanket for service up to 1000F FA 8S sractheLga aa 7 C7Bei ~~ Fiberglas Metal Mesh Blankets are especially suitable for heated industrial equipment with surface irregularities and projections such as seams laps flanges and rivet heads They do an excellent insulating job when used on boilers vessels industrial ovens breechings tanks and many other types of industrial equipment operating at temperatures up to 1000F Fiberglas Metal Mesh Blankets are made from fibrous glass wool faced on one or both sides with wire mesh or metal lath to provide a suitable base for cement or mastic finishes The blankets are flexible and resilient to conform to irregular or curved surfaces A selection of mesh facings is available to best match the service requirements lowers operating costs the exceptionally low k factor of Fiberglas Metal Mesh blankets reduces fuel costs substantially thereby improving the return on in- vestment for the insulation It also controls excessive heat for more comfortable working conditions and personnel protection . lowers installation cost large blankets cover greater areas reducing installation cost No tedious block.by Sager RS crag block hand layup No drilling for studs Blankets are easily impaled over welded studs or pins with speed washers or may be held in place with wire ties applied neat appearance -the applied metal mesh surface provides a base for a smooth trowell coat of insulating cement which may be further finished with canvas and painted Outdoor installations are finished with weatherproof mastic or sheet metal j 4 ) 3 Fost eyes E 3 ce ae On large flat or irregular surfaces blankets are impaled over welded pins or studs and secured with suitable mechanical fasteners Edges of blankets are laced together T.M REG OCF CORP For a good indoor finish apply layer of C 110 Insulat- ing Cement Canvas is then applied with lagging adhesive over the insulating cement ' Litres wen oly GHA, $F performance characteristics 22777: moisture absorption .less than 0.2 by volume thermal .70 conductivity 60 temperature resistance no sag slump or loss of thickness at 1000 F bacteria and fungus resistance .does not breed nor promote temperature limit specific heat . essentially odorless ..- 1000 F see .0.20 .0.20 Btu F. 50 in .40 ft .30 sq 20 hr Btu LZ \ IGO 200 300 400 500 mean temperature F 500 sizes width 12 min 24 max length - 24 min 96 max thickness 6 increments form - blanket facings -Fiberglas blanket tufted by tie wires to a metal facing on opposite sides Recommended where a resilient surface is needed to conform to irregularities on the equipment surface H meti al lath with a rib Used where maximum rigidity is required in a blanket Metal rib turned to the outside ATR or toward insulation RAT Turned rib provides air space between insulation and hot surfaces often advantageous when insulating steel breeching sheels to increase the overall insulating efficiency of the blanket -Conventional " hexagonal poultry netting galvanized prior to weaving The most flexible metal facing Recommended where a blanket must be shaped to irregular surfaces and where movement of the blanket in a panel is to be prevented Not a suitable base for insulating cement -Expanded metal lath with mesh Ideal base for insulating or finishing cement Recommended where a smooth finish is desired on large flat or curved surfaces recommended thicknesses Recommended thickness heat loss efficiency and surface temperature data are provided for the various Commercial Power and Process Industries so that the design engineer can better select the thickness required for his specific job conditions On outdoor work increase recommended thickness at least inch to compensate for wind conditions Ambient Air 80F Surface Temp Amb Air 80 200 300 400 500 600 700 800 900 1000 COMMERCIAL POWER PROCESS RT HL .75 35 1.5 38 2.5 38 ST | RT HL ST | RT HL ST 102 1.5 91 1.0 26 93 103 2.0 30 95 1.5 37 99 103 2.5 39 100 2.0 47 104 3.0 47 104 2.5 58 109 3.5 56 108 3.0 68 114 4.0 64 112 3.5 79 120 5.0 74 117 4.0 90 125 5.5 83 122 4.5 101 131 6.0 94 127 5.0 114 137 recommended thickness heat loss surface temperature application recommendations for round equipment over 35 O.D. Hold the Metal Mesh Blankets in place with 34 metal bands on 12 to 18 centers Lace metal edges that butt together with No. 16 galvanized annealed wire for large flat or irregular surfaces Impale Metal Mesh Blankets over suitable welded fastener on 12 to 18 centers Lace metal edges that butt together place Blankets shall be butted firmly and laced with No. 16 galvanized annealed wire On large vessels or ducts oper ating at temperatures over 600 F expansion joints are required on not greater than 16 foot centers Blankets are available with " metal rib ATR which provides an air space between the insulation and the hot surface for improved thermal performance finishing methods minimum indoor finish or base for further finishes coat of C Insulating Cement Let dry Apply good indoor finish does not require painting To minimum indoor finish apply resin base lagging adhesive 6 or 8 oz canvas and a final brush coat of the lagging adhesive weather resistant finish for outdoor work Trowel two coats of suitable asphalt or vinyl base weather resistant mastic with glass fabric reinforcement between coats Each coat is to be at least a wet thickness specification compliance 563 Insulation Mineral Wool Blanket Felt and Indus Batt For Heated Surfaces Type 1 Class A and B. 558a Insulation Blocks Boards Blankets Felts Sleeving Pipe and Tube Covering and Pipe Fitting Covering Thermal Mineral Fiber Industrial Type Form C Class 10 CONTRACTORS OF CORNING FIBERGLAS INDUSTRIAL INSULATION PRODUCTS ALABAMA BIRMINGHAM North Brothers Company 205 = 595-3791 & 595,477 MOBILE Insulation Engineers Inc. 205457.9271 205457.9271 205457.9271 205457.9271 Shook & Fletcher Insulation Co. 205- 205- = 479-6592 ARIZONA PHOENIX Owens Corning Fiberglas Corp. Supply & Contracting Division 602 258.4541 TUCSON Preston's Insulation Service 602 795-2441 ARKANSAS LITTLE ROCK Ozark Insulation Co. Inc. 501 - 663-8379 CALIFORNIA FRESNO Corning Fiberglos Corp. Supply & Contracting Division 209 233-5871 GOLETA Corning Fiberglas Corp. Supply & Contracting Division 805 - 967-5664 LOS ANGELES Corning Fiberglas Corp. Supply & Contracting Division 213 723-9781 Western Fibrous Glass , 213 588-3211 SACRAMENTO Corning Fiberglas Corp. Supply & Contracting Division 916 - 927.7341 SAN BERNARDINO Corming Fiberglas Corp. Supply & Contracting Division 714 we 885-3496 SAN DIEGO Corning Fiberglas Corp. Supply & Contracting Division 714 = 276-5820 SAN JOSE Corning Fiberglas Corp. Supply & Contracting Division 408 = 297.9520 SO SAN FRANCISCO Corning Fiberglas Corp. Supply & Contracting Division 415 873-7400 CONNECTICUT BRIDGEPORT ADC Supply & Contracting 203 - 367-7773 EAST HARTFORD Cens Corning Fiberglas Corp Supply & Contracting Division 203 289-6431 COLORADO DENVER Construction Specialties Co. 303 = 534-3271 DELAWARE WILMINGTON Delaware Insulation 302654-8826 302654-8826 302654-8826 DISTRICT OF COLUMBIA WASHINGTON fm. f Walter E Compbell Company 301 = 329.0100 ORIDA FT LAUDERDALE North Brothers Co. 305 933-9376 JACKSONVILLE North Brothers Company 904 355-8563 FLORIDA Cont ORLANDO North Brothers Company 305- 305- = 293-9221 TAMPA North Brothers Company 813 - = 223-5568 GEORGIA ATLANTA North Brothers Company 104- > 622.1513 SAVANNAH North Brothers Company 932 = 233.5774 HAWAR HONOLULU Associated Insulation Co 808563-402 808563-402 808563-402 Craig & Company 808 - = 507.402 IDAHO BOISE Corning Fiberglas Corp Supply & Contracting Division 208 342-931 ILLINOIS CHICAGO Illinois Insulation & Construction Co. 312 779-8600 Poul J Kret Company 312 - = 467-0062 MOLINE Taylor Insulation Company 309 - 764-2339 PEORIA Sprinkmann Sons Corp. of IllinoU 309- 309- 674-5112 INDIANA EVANSVILLE General Insulation Company 812-476-1315 812-476-1315 Corning Fiberglas Corp. Supply & Contracting Division 812 - 425-5124 INDIANAPOLIS Central Rubber & Supply Co. Inc. 317 - 634-5585 Corning Fiberglas Corp. Supply & Contracting Division 317 898.1140 IOWA DES MOINES & Lk Insulations Compony 515 -- 288-0164 DAVENPORT Economy Roofing & Insulation Co 319 - 326-6241 KANSAS WICHITA Buckley Construction Industries 316 262-0426 KENTUCKY LEXINGTON Ulter Company 606 > = 252-8834 LOUISVILLE Corning Fiberglas Corp. Supply & Contracting Division 502637-2588 502637-2588 502637-2588 502637-2588 PADUCAH Triangle insulation Company Inc. 502 = 443-2424 LOUISIANA BATON ROUGE Anca Insulation Inc. 504- 504- 355-7731 Reilly Benton Company Inc. 504 344.6572 LOUISIANA Cont FRANKLIN P & R Insulation 318-828-1570 318-828-1570 318-828-1570 318-828-1570 NEW ORLEANS Anco Insulation Inc. 504 - = 721-1132 Seidenbach 504529.3427 504529.3427 504529.3427 504529.3427 Benton Company Inc. 504 = 524-3374 SHREVEPORT R. F. Zimmerman 318 = 423-3549 MARYLAND BALTIMORE McCormick Asbestos 301 -A 664-6040 Corning Fiberglas Corp. Supply & Contracting Division 301-488-8200 301-488-8200 301-488-8200 301-488-8200 SUBURBAN DIST of COL Walter E. Campbell Company 301 - # 399.0100 a MASSACHUSETTS BOSTON NEW England Insulation Company 617-445-7800 617-445-7800 617-445-7800 CAMBRIDGE The Eckel Corporation 617-491-3221 617-491-3221 617-491-3221 MICHIGAN | DETROIT Coon DeVisser Company 313-825-6000 313-825-6000 313-825-6000 Corning Fiberglas Corp. Supply & Contracting DiviSION 313 = 47.8000 FLINT Corning Fiberglas Cero Supply & Contracting Division 313 = 787.2595 GRAND RAPIDS Corning Fiberglas Corp. Supply & Contracting Division 616-241-018 616-241-018 616-241-018 LANSING Omens Corning Fiberglas Corp. Supply & Contracting Division 517 372-4930 MINNESOTA DULUTH A W. Kvettel & Sons Inc. 218 722-3901 MINNEAPOLIS A. Bennett Company 612 # 374-3444 MISSISSIPPI JACKSON North Brothers Company 601 354-5217 MISSOURI JOPLIN Midwest Materials Inc. - 417 623-1272 MARYLAND HEIGHTS Corning Fiberglas Corp. Supply & Contracting Division 314412.3790 314412.3790 314412.3790 NORTH KANSAS CITY Corning Fiberglas Corp. Supply & Contracting Division 826 = 842.8444 ST LOUIS Souther Steel & Aluminum Company 314 385-5900 SPRINGFIELD Midwell Materials Inc. 417 865-3021 + a 5 EY WO PG rr ? ay % repl we MTA < rile ~y % oa a MONTANA BILLINGS Corning Fiberglas Corp. Supply & Contracting Division 106- 106- 252.8490 NEBRASKA EAST OMAHA Vaughn Insulation Compnay 402 - # 281-5822 OMAHA Conspeco 402 - 453-7257 NEW JERSEY HILLSIDE York Infulation Company 201 373-2212 JERSEY CITY Empire Ace 201 - # 433-1700 LITTLE FERRY Notional Dist Company 201 - 768-2500 NEWARK Corning Fiberglas Corp Supply & Contracting Division 201 = 484-2800 WASHINGTON Mueller Inc. 201 689-2287 NEW MEXICO ALBUQUERQUE Corning Fiberglas Corp. Supply & Contracting DivisIDA 505 = 243-4583 NEW YORK ALBANY Robert A. Keasbey Company 518 = 436-4787 BROOKLYN Empira Ace 212-649.4900 212-649.4900 212-649.4900 BUFFALO Buffalo Insulation Distributors Distributors Inc. 716 876-7344 NEW YORK Eastern Steam Specially Company 212-964-8550 212-964-8550 212-964-8550 A. Kecsbey 212243-8300 212243-8300 212243-8300 PORT CHESTER Asbestos Distributors 914 - 939-0777 ROCHESTER Rochester Industrial Insulatan Inc. 716-458-5816 716-458-5816 SYRACUSE Robert A Keasbey Company 315 474.6494 NORTH CAROLINA CHARLOTTE Covil Insulation Company 704-366-7478 704-366-7478 704-366-7478 GREENSBORO Covil Insulation Company 919 - # 275-2894 RALEIGH Standard Insulation Company 919 - # 833-2150 WILSON Covil Sales Company 919-237-5486 919-237-5486 919-237-5486 919-237-5486 NORTH DAKOTA FARGO Building Sprinter Co Inc. 701 = 232.8933 OHIO CANTON Edward R. Hort Company 216-452-4055 216-452-4055 216-452-405 216-452-4055 CINCINNATI Corning Fiberglas Corp. Supply & Contracting Division 513 # 563-2323 CLEVELAND Clark Asbestos Company 216881-2141 216881-2141 216881-2141 COLUMBUS Service Products Inc. 614- 614- 237-4247 DAYTON Complete Insulation Service Inc 513-423-0162 513-423-0162 513-423-0162 513-423-0162 MARIETTA Asbestos & Insulating Company 614 373-6417 TOLEDO Service Products Inc. 419 - 536-3752 YOUNGSTOWN Asbestos Service Compony 216 - 744-2145 OREGON PORTLAND Corning Fiberglas Corp. Supply & Contracting Division 503- 503- 226-6781 PENNSYLVANIA BERWYN Corning Fiberglos Corp. Supply & Contracting Division 215- 215- 647-2700 HARRISBURG Flack Brothers 717 - 238-9401 KINGSTON Culp Industrial Insulation 717- 717- 288-5487 MCKEES ROCKS Geo V. Hamilton Inc. 412 - 771-0900 RHODE ISLAND RUMFORD Owens Corning Fiberglas Corp Supply & Contracting Division 401 434-7435 SOUTH CAROLINA CHARLESTON North Brothers Incorporated 803- 803- 723-7011 COLUMBIA North Brothers Incorporated 803 = 252-3702 GREENVILLE Covil Insulation Company 803 = 246-1521 TENNESSEE CHATTANOOGA Breeding Insulation Company 615- 615- 698-8019 KNOXVILLE Breeding Insulation Company 615 - 524-5503 North Brothers Company 615 - -546-2231 -546-2231 MEMPHIS Industrial Insulation Co. 106 - = 527-7531 NASHVILLE Breeding Insulation Company 615 - = 255.0913 TEXAS BEAUMONT The Industrial Insulators Inc. 713 - 832-8117 BORGER Industrial Insulators Inc. 806 274.1347 Standard Asbestos Mfg & Insulating Co. * 806 - = 273.2805 DALLAS B & B Engineering & Supply Co. 214637.1661 214637.1661 214637.161 214637.1661 P.F Supply Co. Inc. 214-428-2876 214-428-2876 214-428-2876 214-428-2876 EL PASO Willard 915-533.1438 915-533.1438 A. Selle Inc. 915-53.1438 915-533.1438 FT WORTH E. O. Gene Wood Co. 817-332-6151 817-332-6151 817-332-6151 817-332-6151 HOUSTON The industrial Insulators Inc. 713-926-4435 713-926-4435 713-926-4435 Corning Fiberglas Corp. Supply & Contracting Division 713-869-6311 713-869-6311 713-869-6311 713-869-6311 ODESSA Stor Insulation Company 915-332-0901 915-332-0901 915-332-0901 Ow UTAH SALT LAKE CITY Bullough Asbestos & Supply Co. 801= 328-9887 Corning Fiberglas Corp. Supply & Contracting Division 801= 487-6204 VIRGINIA NORFOLK C. E. Thurston & Sons Incorporated 703-627-7751 703-627-7751 703-627-7751 RICHMOND E. Thurston & Sons Incorporated 703 233.6957 Waco Insulation Compory Inc. 703 - # 233-3051 ROANOKE C. E. Thurston & Sons Incorporated 703 7342-1841 WASHINGTON SEATTLE Associated Asbestos Company 206 294-0111 Corning Fiberglas Corp. Supply & Contracting Divisi^n 206 763-2800 Western Fibrous Glass Products 206624-7250 206624-7250 206624-7250 SPOKANE Associated Asbestos Co. 509 - 326-0200 Corning Fiberglas Corp. Supply & Contracting Division 509 - -924-6011 WEST VIRGINIA S. CHARLESTON Asbestos & Insulating Company 304-768-0017 304-768-0017 304-768-0017 WISCONSIN LA CROSSE La Crosse Plumbing Supply Co. 603 784-3827 Inc. MILMWILWAUKEAMUILKWAEUKEEE Building Service Industrial Sales Company 414- 414- 453-6785 rena Offices of Corning Fiberglas Corporation Akron Ohio Albany New York Albuquerque N. M. Anchorage Alaska Atlanta Georgia 216--836-9546 518-869-0221 505-243-4583 907--272-6425 404-355-6821 Baltimore Md Bethlehem Pa Billings Montana Birmingham Alabama Boise Idaho Boston Massachusetts Buffalo New York 301-727-0234 215-865-0427 406-252-8496 205-252-4184 208-342-9311 208-342-9311 617-235-7540 716-832-1410 Charleston W. Va Charlotte N. C. Chicago Illinois Cincinnati Ohio Cleveland Ohio Columbia C. Columbus Ohio 304-343-7094 704-372-7065 312-583-0100 513-281-1173 216-884-9440 803-252-1384 614-486-9418 Dallas Texas Denver Colorado Des Moines Iowa Detroit Michigan 214-521-7751 303-777-6694 515-288-4273 313-547-8000 East Hartford Conn El Paso Texas Eugene Oregon Evansville Indiana 203-289-6411 915-533-8208 503-345-4114 812-425-5124 Flint Michigan Tort Wayne Indiana esno California Grand Rapids Michigan Green Bay Wisconsin Greensboro N. C. Greenville S. C. 313-787-6573 219-743-5341 209-233-5871209-23-5871 616-452-8788 414-494-4343 919-273-0528 803-239-4279 Harrisburg Pa 717-761-0430 Honolulu Hawaii Houston Texas 808-537-3832 713-869-3351 Indianapolis Indiana Jackson Mississippi Jacksonville Florida 317-898-1140 601-982-4337 904--786-2838 Kansas City Missouri Knoxville Tennessee 816-753-7725 615-584-3421 Lansing Michigan Little Rock Arkansas Los Angeles California Louisville Kentucky 517-372-4930 517-372-4930 501-664-2133 213-685-4381 502-897-3276 Memphis Tennessee Miami Florida Milwaukee Wisconsin Minneapolis Minnesota Mobile Alabama 901-327-6116 305-624-2669 414-344-3811 612-545-3791 205-471-5465 205-471-5465 Nashville Tennessee Newark New Jersey New Orleans Louisiana New York New York Norfolk Virginia 615-298-3646 201-484-2800 504-837-2902 212-759-3810 212-759-3810 703-853-9162 Oklahoma City Okla Omaha Nebraska Orlando Florida 405-528-4468 402-339-2626 305-425-3481 Peoria Illinois Philadelphia Pa Phoenix Arizona Pittsburgh Pa Portland Oregon Providence R. I. 309-682-9622 215-688-8650 602-258-1588 412-563-774126-563-67766 503-292-0781 401-434-7435 Raleigh C. Richmond Virginia Roanoke Virginia Rochester New York Rock Island Illinois 919-833-7716 703-355-5703 703-362-1177 716-288-2200 309-788-1190 Sacramento Calif St. Louis Missouri Salt Lake City Utah San Antonio Texas San Bernardino Calif San Diego California San Francisco Calif San Jose California Savannah Georgia Scarsdale New York Seattle Washington Shreveport La Sioux Falls S. D. Spokane Washington Syracuse New York 916-927-1341 314-991-2640 801-487-1361 512-342-9531 714-888-0141 714-276-7711 415-873-7950 408-297-9520 912-233-5980 914-472-3400 206-762-4250 318-865-7511 605-334-3821 509-924-6532 315-463-4541 Tampa Florida Toledo Ohio Tulsa Oklahoma 813-877-7516 419-259-3030 918-627-1220 Washington D.C. Gov't Washington D.C. Sales Wichita Kansas Windsor Conn 202 296-3296 301-434-6100 316-265-2522 203-524-5987 INTERNATIONAL GENERAL OFFICE New York New York 212-759-3810 EXPORT SALES OFFICES Miami Florida San Francisco Calif 305-624-4172 415-873-7950 EUROPEAN SALES OFFICES Brussels Belgium Milan Italy Paris France 72.23.26 468090 265-3301 Wiesbaden Germany 01-127-84004 CORNING FIBERGLAS CORP Industrial and Commercial Construction Materials Division Fiberglas Tower Toledo Ohio 43601 . Cate tones. se _ eaaa for nd foforr for en a enrc ? meme one ( AND SUPPLY SUPPLY SUPPLY SUPPLY SUPPLY SUPPLY AND AND AND CONTRACTING CONTRACTING CONTRACTING CONTRACTING CONTRACTING CONTRACTING CONTRACTING CONTRACTING CONTRACTING CONTRACTING DIVISION DIVISION DIVISION DIVISION DIVISION SERVICES SERVICES SERVICES SERVICES SERVICES SERVICES SERVICES THE PLANT ENGINEER ENGINEER - SUBRESIDENTRESIDEBNRTANCH we OFFICE SUB BRANCHBRANCHOF ICE OFFICEOFFICE RESIDENT RESIDENT OFFICE OFFICEOFFICE we ue e sem one ( ae me ae we o : ir a wa vf ~~ ase be OR hey A ee SUPPLY AND CONTRACTING DIVISION EE ON INDUSTRIAL INSULATIONS OCF offers a full line of industrial insulation products including insula- oPtas tion materials for power and processing piping systems plumbing heating and conditioning piping systems hot and cold vessels tanks boilers turbines and related duct work Fiberglas pipe insulation is designed not only for cold piping systems but hot piping systems up to 400 For higher temperature piping systems Kaylo insulation is recommended for applications to Kaylo 20 to 1800 A wide range of Fiberglas Rigid and Semi Rigid Boards Metal Mesh Blankets Kaylo Block and Kaylo 20 Block insulation materials are available for hot or cold equipment Fiberglas and Kaylo Block are also well suited for insulating vessels tanks boilers and chimneys AIR HANDLING Fiberglas Duct Systems are a combination of thermal and acoustical insulations with an integral vapor barrier jacket The highly efficient insulation is rigid uniform heavy density Fiberglas The attractive flame retardant puncture resistant vapor barrier jacket is either a laminate of vinyl and foil reinforced with Fiberglas yarn or embossed kraft and foil reinforced with Fiberglas yarn A complete line of Duct Liner and Duct Wrap insulation products are also available for use with existing duct systems OCF Supply and Contracting Units also supplies a variety of Fiberglas filters to meet industrial requirements Many allied products are also available through the local S & C Unit including such items as flexible tubing ACOUSTICAL MATERIALS Fiberglas ceiling panels tiles and ceiling boards are dimensionally stable They are the only acoustical materials guaranteed in writing not to warp buckle or sag They provide low cost low maintenance acoustically efficient high light reflection combustible ceiling treatments Fiberglas acoustical materials also provide the most effi cient insulation of any sound control product Fiberglas acoustical products not only efficiently reduce noise and heat loss but present a neat finished appearance BUILDING INSULATIONS To insure having the correct product for any building insulation application each OCF S & C Unit carries a full line of building insulation products Included are Fiberglas Kraft Faced Foil Faced and Friction Fit building insulations as well as Sill Sealer for foundation sealing Pouring Wool for ceilings and Perimeter insulation for crawl space walls A special Fiberglas blanket insulating material is available for insulating metal buildings Every type of insulation material required for the complete insulation of cold storage systems is available from OCF Translucent flat or corregated Fiberglas reinforced plastic panels are offered for a variety of applications ROOFING PRODUCTS OCF also supplies a complete line of roof insulating materials Built Roofing Membrane Fiberglas Vapor Barrier Fiberglas Roof Insulation are only a few of the products available through the local S & C Unit Fiberglas reinforced Roof Tape Cant Strip and other Fiberglas roofing accessories are available through the Units Fiberglas Roof Insulation is composed of durable glassfibers faced with a tough glass fiber reinforced asphalt and kraft mopping surface Handling and installation are facilitated by its light weight place performance is assured because Fiberglas cannot rot warp buckle or shrink Fiberglas boards are made in large 3 x 4 and 4 x 4 sizes and are available in thickness ranging from ... through 2 DISTRIBUTION SERVICES a es Vere CS Tete Sr A ee meme a WAREHOUSE SERVICE Modern OCF Supply and Contracting Division office and warehouse facilities are strategically located across the country providing convenient outlets to industry and the Plant Engineer for a line of OCF construction materials and related products 7 ective of each OCF Supply and Contracting Unit is to I sufficient local inventory of these products to provide fast erficient and economical service to meet critical shutdown and maintenance schedules TRUCKING SERVICE Corning Fiberglas recognizes that it is not enough to simply make their construction materials readily available and that these products can be conveniently used only if they are delivered to the right place at the right time This is why the OCF Supply and Contracting Division operates a large fleet of delivery trucks to insure the timely and economical delivery of OCF products from the warehouse to the industrial plant COMPLETE PACKAGE e a caer mireaee Ste r We tc FABRICATION SERVICE . To meet the individual needs of its customers OCF Supply and Contracting Division also makes available fabrication services to custom fabricate OCF construc tion materials This service can reduce both the cost and the time required to install these products at the industrial plant location Each local OCF Supply and Contracting Division ware house carries In addition to its complete line of OCF materials a full line of allied prod ucts and accessories for the FECHNICAL FECHNICAL SERVICE complete installation of these construction materials This assist the Plant Engineer and the Maintenance one stop shop concept Foreman OCF Supply and Contracting Division has wan trained salesmen and construction personnel equipped eliminates the need for multi- ple purchases and deliveries to recommend products and application methods for to complete a maintenance installation of OCF construction products project ott INDUSTRIAL INSULATION CONTRACTING SERVICES To further assist its customers Corning Fiberglas Supply and Contracting Division provides complete in- stallation services through most of its units Trained experienced estimating and field construction personnel are equipped to handle every type and size of insulation contract including insulation of hot and cold piping equipment vessels duct work and boilers The OCF field unit can choose from a complete line of immediately available insulation materials and accessories which cover a temperature range of from zero to 1800 A large crew of experienced journeymen construction workers are regularly employed on a round basis in order to promptly meet customer construction schedules Competent field foremen are available to coordinate the insulation work with other construction crews To further assist its field Supply and Contracting Units Corning Fiberglas is specially staffed to provide complete insulation designs to meet every kind of industrial insulation requirement Corning is a manufacturer supplier and contractor experienced in insulation contracts ranging from hundreds of dollars to millions of dollars in size and scope From start to finish accurate estimates and prompt bids through quality application and time competition of work Corning Fiberglas contracting service assure the customer of a job well done Qeteene ee ee wees . CONTRACTING SERVICES 7 a COLD STORAGE CONTRACTING SERVICE A highly specialized area of the insulation field is the design engineering and application of insulation mateials for temperature rooms OCF Supply and Con tracting Units have crews of skilled workmen with years of experience in this particular field of insulation work Food storage warehouses processing plants and walk refrigerators are among the many successful cold stor- age applications executed by the Supply and Contracting Division The illustrations at the right show the construc ion of a Conducting Stud Dry Wall System just one of many types of Cold Storage Systems available through the Corning Fiberglas Supply and Contracting Division a o ee Own PST PST abe ver OwnOwn Own | re a 6 Try Co meme eer ge. gen wine Suey Prmewticane Semneee ee Socom PCr Ls BS ita RE 7 s etreualnT catle4 Late et Ata eee 1 aes 13 ON 27S eS aPban ee we ere = srafides) = Se een SATS COST SEI AEE rs =" =a OE AIT ali 4 IE IA 27 27 27 ear 7 canter Tey 2 RR eek 77 Poi #S, er . TF eo ie, ere n vee . : . ses: SAE ie Sas, ACOUSTICAL CONTRACTING SERVICE Corning Fiberglas Supply and Contracting Divi- sion acoustical contracting departments are set up to provide customers with complete acoustical contracting service This service includes estimating engineering and design and the capability to install acoustical ceilings of all types including acoustical specialty applications S & C acoustical contracting Units across the country have acquired valuable experience in the acoustical installation field in determining the best let design and economies in this rapidly changing installa- ion field This experience combined with the technical qe biertnao assistance and wide range of acoustical materials avail- on able from OCF adds great value to the service the Supply ih rsie ~t~racting Division is able to offer the customer ne, oe 4 we * erntiavedSER __ FIBERGLAS SUPPLY AND CONTRACTING DIVISIONS S LOCATION Box P.O. , Town 1011 Saw Mill Road N.W. 505-243-4583 Station ANCHORAGE ALASKA 99501 O. Box 833 1907 Post Road 907-275-8344 : ATLANTA GEORGIA O. Station Box Station N 30325 1605 Marietta Blvd. N. W. 30318 404-355-6821 BALTIMORE MARYLAND 21237 6601 Moravia Road 301-488-8200 BILLINGS O. BIBoLxLINGS 59103 920 3rd Avenue N. 59101 406-252-8496 BIRMINGHAM ALABAMA P. O. Box 1933 112 S. 14th Street 205-252-4184 35201 BOISE O. BoIxDAHO 83701 325 Grove Street 208-342-9311 CHARLOTTE N. CAROLINA 28201 P. O. Box 10857 4100 Drive 704-3C9h2e-a8s3a6p6eake CINCINNATI OHIO 45241 2987 Exon Drive 513-563-2323 CHICAGO ILLINOIS 2300 Estes Avenue Elk Grove Village 312-439-5330 60007 DETROIT MICHIGAN 48237 15300 West Eight Mile Road 313-547-8000 EAST HARTFORD P. O. Box CONNECTICUT 06108 181 Burnham Street 203-289-6411 EL PASO TEXAS O. Box 1650 79949 120 N. Cotton 79901 915-533-8208 FLINT MICHIGAN 48504 4099 Dolan Drive 313-787-2595 FORT WAYNE INDIANA 46802 E. Berry Street Room 920 Anthony Wayne Bldg 219-743-5341 FRESNO D. Box CALIFORNIA 93709 77 M Street 209-233-5871 GRAND RAPIDS MICHIGAN 49508 1055 36th Street S.E. 616-241-0181 HOUSTON HOUSTON O. Box 328 77008 3375 West 11th 77001 713-869-6311 INDIANAPOLIS INDIANA 46219 O. Box 19093 Tobey 317-898-1140 Avenue Avenue JACKSONVILLE FLORIDA 32205 5350 Overmyer Drive P. O. Box 6797 904-388-4681 MISSOURI N.O. KANBSoxAS CITY 1207 Macon Street 64116 816-842-6444 LANSING MICHIGAN 48911 719 E. St. Joseph St. 517-372-4930 Indust Insula ne DISTRIBUTIOn services Air Handling Acoust Matis Wall & Panel Systs rs) w t we Aw) : . a) Cw) w Sai E . E wi S . . es) ws . 7 ' tod 4 a : a . oe) 2 4 o 7 CONTRACTING SERVICES Rfg Prod ro e - Indust Insula . e . w Acoust & , Lo] Cold Storage e. e ~ 0 & 23 ra & @ @ : re) i D ' D 2 E , - wv Ww " 3 yy - ) o, o @ a G 7 @ <& oO ~ ' @ te) @ 3 0 0 u ' 2 < ., C Ww D D o , 3 :) - :) cH) 13 cs) ra G E re) j |e} i C uw C ' C ied on E 0 e & iG o| v G c 0 0 @ -. . wo & 24 Cy) S Cc eS . re) =] | : e eo] e3 o ta. 0 a & Ps] . rs) 3) o G ' 6 % a o o & a ' 3 S @ < 6 & & & e 8 9 roe a ne tr eee were SA eee ei ee eee ree e en: PST Own & LOCATION LOS ANGELES CALIFORNIA O. Box 22045 5933 Telegraph Road 213-723-9781 90022 LOUISVILLE KENTUCKY 40217 2106 Hahn Street 502-637-2588 MEMPHIS TENNESSEE O. Box 9416 323 Saturn Drive 901-397-4415 38109 MIAMI FLORIDA 33162 56 N.E. 181st Street N. Miami Beach Florida 305-624-8463 NEWARK NEW JERSEY 07029 43-57 Harrison Avenue Harrison N.J. 201-484-2800 OKLAHOMA CITY OKLAHOMA 73118 4610 N. Cooper Street 405-528-2727 ORLANDO FLORIDA 32805 541-543 W. Grant Street 305-425-3481 PHILADELPHIA PENNSYLVANIA 592 W. Swedesford Road Berwyn Pennsylvania -647-2700 19312 ENIX ARIZONA W. Fillmore 85007 P. Box 6050 85009 602-258-4541 PORTLAND OREGON 97209 320 N.W. Street 503-226-5603-72268-67181 PROVIDENCE RHODE 49 Newman Ave. ISLAND 02916 Rumford Rhode Island 401 434-7435 SACRAMENTO CALIFORNIA O. Box F 95813 1041 Fee Drive 95815 916-927-1341 SALT LAKE CITY UTAH 84119 840 W. 2600 South 801-487-6204 SAN ANTONIO TEXAS 78209 1104 N. Cherry Street 512-222-9544 SAN BERNARDINO CALIFORNIA 92410 456 Industrial Road 714-885-3496 SAN DIEGO CALIFORNIA 92110 1033 Cudahy Place 714-276-5820 SOUTH SAN FRANCISCO 477 Forbes Boulevard 415-873-7400 CALIFORNIA 94080 SAN JOSE CALIFORNIA 95112 1723 Junction Avenue 408-297-9520 SEATTLE WASHINGTON 98108 6020 Maynard Avenue S. 206-763-2800 SPOKANE WASHINGTON Terminal Box 2945 99220 | Spokane Industrial Park Bldg 5 509-924-6011 LOUIS MISSOURI 63042 ST Schuetz Road and Heights Missouri . 432-3790 TAMPA FLORIDA 33601 O. Box 3327 811 North 50th Street 813-248-5081 TULSA OKLAHOMA O. Box 4789 74114 6558 E. 42nd Street 74145 918-627-1220 Indust Insula DISTRIBUTION SERVICES Air Handling Acoust Matis Wall & Panel Systs sreanne, at CONTRACTING SERVICES Rfg Prod ate oe ope Indust Insula Acoust Ser entre a mr pm be ey, L Cold Storage 2 0 @ ) C > E " C 3 3/5] vr) 0 9/ 3 3 4 eg . rere ORNS Sky oes Pes aH tN oo, ae _~ eae - e ={$= wet SUPPLY AND CONTRACTING DIVISION FILESPONSIBILITY FILESPONSIBILITY FILESPONSIBILITY FILESPONSIBILIFILESTPONSYIBILITYFILESPONSIBILITY FILESPONSIBILITY FILESPONIBLTY FILESPONSIBILITY FILESPONSIBLITY The Corning Fiberglas Supply and Contracting Division is backed by the capital resources of the corporation Thus customers need have no worry regarding the sound financial responsibility of any OCF Supply and Con- fs ee 744 ae gyset <_ ia whelis ; Rhy oe Sok Besta a ete, LOCAL OR MATION MATION ae ry as Each OCF Supply Supply and Contracting Unit is organized to provide the customer ____4 _ moe wel with local services and local advantages The needs of the locale itself dictate P gfG e the type of materials to be stocked and the kinds of contracting services to be hate working knowledge _ : Supply Contracting rendered Each OCF and Contracting Unit working Unit has a t of legal requirements tax regulations and other administrative practices important to each local situation a a ae eet ee ee ew kt ee ae oh es Contracting and sales personnel engineers managers estimators and field superintendents are well qualified to handle their special jobs because they have been carefully selected and thoroughly trained They have the additional advantage of being able to call upon the experience gained by a nationwide contracting distributing organization FIELD ORGANIZATION OCF Supply and Contracting Units throughout the country regularly employ skilled mechanics from the various trades The regular employment of com petent local construction workers is a distinct advantage to the customer It is further assurance of good workmanship timely performance and a job well done