Document LJ7kL9BM8590YGD67mVvYoYOq
Insulation, Underground
Insulation, Underground
The Ric-wiL Company
Agents In Principal Cities
Established in 1910
CONDUIT SYSTEMS FOR UNDERGROUND STEAM PIPES
Union Trust Bldg., Cleveland, Ohio--New York, Chicago, San Francisco
Underground Steam Construction Co.
75 Pitts Street, Boston, Mass.
Conduit--Standard conduit is vitrified
salt glazed tile or cast-iron with Loc-liP
PRODUCTS--Engineering and Contracting of Steam Line
Side Joints, bell and spigot type, lined or unlined. Tile in 24 in. sections, sizes 4 to
Installations. Underground Steam Conduits.
27 in. inside diameter. A Super-Tile con
duit to support any average traffic load is
also available. For extra heavy duty
USCCO PRE-CAST CONCRETE CONDUIT
under railroads or where conduit is subject
to extreme loads, Ric-wiL is made of cast-
This unit marks a long step forward in the economics and mechanics of laying under
iron in 2 or 4 ft sections. Where reduced labor cost is not essential, Ric-wiL Uni
ground steam lines.
versal Type System is recommended (details on request).
Its Outstanding Features Are:
Base Drain--Standard Base Drain is
vitrified salt glazed tile for tile conduit and
extra heavy tile or cast-iron for the cast-
Strength resulting from flat reinforced
iron conduit, in 24 in. lengths. Made in
bell; from the longitudinal joints, and
three sizes to support and drain properly all conduit sizes.
Pipe Supports--Standard pipe sup ports will carry from one to five or more pipes and are ordinarily spaced 12 ft apart.
as Dry-paC except non-waterproof) or sectional pipe covering can also be fur nished. For lined conduit, diateomaceous earth mixture is molded and keyed inside
from the fact its sections are 4 ft long, reducing the usual number of joints necessary.
They are strong, made of cast-iron, rustproofed, and interlock with the base drain
foundation, imposing no load on the con duit itself. No movement of pipes can disturb them. Special pipe supports avail
the tile. Accessories--Shutter sleeves, filter
cloth, asphalt joint cement, water-proofing compound, manhole covers, and other accessories will be furnished as desired.
Shape which allows 12 per cent greater inside capacity than circular conduit of like diameter. This permits larger pipes in a given size conduit and more room for
able for different conditions. Information
Engineering Service--Full coopera
on request.
tion with architects and engineers. In
Insulation--Ric-wiL Dry-paC Water stallation supervision if desired.
drainage, pipe supports and rolls. Ease of Installation resulting from the
proof Insulation is high-grade long fibre asbestos processed so that it is permanently water repellant. Of unusually high-
efficiency and great natural strength, it will not slump away from pipes and is noncorrosive. Sample will be sent gladly for
Technical Data--Tabulated Steam Heating Rates, Test Reports, Service
Detail Bulletins, Catalog Bulletins, Central and District Heating Bulletins and Archi
tects and Engineers Detail Sheets available upon request.
i
fact that all top and bottom halves mate. Bottoms may be laid for any distance, the piping installed and then the tops brought up and laid. This speeds up the work and protects idle halves from damage. They
testing. Ric-wiL No. 11 Insulation (same
can be stored away from the job.
Materials are high strength cement with suitable aggregate, amply reinforced with wire mesh.
Pipe Supports are of cast-iron and quickly installed. They may be placed anywhere in the conduit. The weight of the pipe holds them in place.
Ric-wiL- Unit Steam Main, a prefabricated. ready-to-imtaU
unit,
ft long, including conduit (Artnco Inn), pipe,
insulation, and accessories. Ideal for speed and economy on
district heating projects.
Joints may be of any standard accepted brand of jointing compound or they may be of standard Portland cement mortar.
1054 1 1055