Document LD2qjZ0RYOz2gZdvExZeXN3b
Pydraul fact finder
AIR COMPRESSOR LUBRICANTS
Bulletin number IC/FF-2
The Pydraul Air Compressor Fact Finder ... is designed to make the many facts about Pydraul fire resistant lubricants for air compressors--Pydraul 30E, Pydraul 90E and Pydraul 115E--easy to find. These safety lubricants for air compressors were specially developed to offer you: Safety from Fire and Explosion Pydraul reduces combustible mists and minimizes carbonaceous residues--greatly reducing the threat of compressor fires and explosions. Lower Maintenance Costs Pydraul reduces deposits on exhaust valves, in cool ers and in piping. You save the costs of compressor downtime and cleaning. Many compressor users find these savings alone justify using Pydraul lubricants.
006d2L8
pyprauL
Monsanto
TOWOLDMONOQ21561
Pydraul fact finder
HOW COMPRESSOR FIRES & EXPLOSIONS OCCUR
Every theory about the mechanisms of compressor fires and explosions hold one idea in common: petroleum oils are directly involved.
Petroleum Oil Mists & Films
Mist and accumulated films from petroleum oil in compressor systems can, under a variety of con ditions. break down into combustible gases and carbonaceous residues that can ignite and pro duce an explosion, a receiver fire--or both. The U. S. Bureau of Mines1 found that carbon deposits in air compressors lubricated with petroleum oil form a "carbon-oxygen complex." Oxidation forms this complex, and accelerated by heat, this oxida tion process can lead to an explosion.
The Shortcomings of Safety Devices
Safety devices do not completely eliminate fire and explosion possibilities. A study on "The Mech anism of Explosions In Starting Air Lines,"2 based on an exhaustive survey of compressor operations at 53 companies, reports that a stuck or leaking air check valve permits the engine being started to pack the section of line between the check and air timing valve with an explosive "oil residue-air" mixture. A pressure wave will force this mixture upstream into the main air line--and coupling this with good flame propagation in the power cylin der, the condition is laid for explosion in the pipe system.
Air line explosions and fires may even occur with out the engine being started or before the ignition
is turned on. Carbon and rust particles in a "hot" air line, due to operating an overheated compres sor too long--hardly an improbable conditioncan become saturated with oil, and with the flow of starting air, can cause these oil-saturated parti cles to flame.
Explosion Tests at 1300 PSI The Walter Kidde Company, makers of fire extin guishing equipment, warns in a study3 that users of high pressure air should guard against intro ducing a shock wave into high pressure lines by suddenly opening a plug cock in air compressor systems using petroleum oil. This report showed that in a 1-inch diameter tube, the inside walls filmed with oil, a sudden admission of air at pres sures above 1300 psi caused combustion.
How can you eliminate the conditions that cause fires and explosions in air compressors? Eliminate the source of carbon deposits, the basic cause of most air compressor disasters--petroleum oil.
Substitute fire- and explosion-resistant Pydraul.
1. "The Carbon-Oxygen Complex as a Possible Initiator of Explosions and Formation of Carbon Monoxide in Compressed Air Systems," by Busch, Berger, and Schrenk, Bureau of Mines paper R.1.4465, June 1949.
2. "The Mechanism of Explosions in Starting Air Lines," by Ridgway, Robert S., Petroleum Refiner, June 1958.
3. "Oil Combustion Phenomena in High Pressure Air Systems," M .W. Weibel, Walter Kidde & Co.. Inc., Report R-831, copyright 1952.
006?19
TOWOLDMONOQ21562
Table 1
PHYSICAL PROPERTIES
Appearance
Spec. Gravity 25/25C.
Neutralization Number (Acidity) (mg KOH/gm) max.
Moisture (max.)
VISCOSITY
Centistokes (> 100F.
Centistokes (<r 210F. Saybolts or JOCTF.
210F.
"Absolute Saybolts" (' 100F.
(SSU x Density)
21CTF.
Pour Point
Compressibility x 10 6 sq. in./lb.
Maximum Exit Air Temperature
Boiling Point CF. at 760 mm Hg.
Coefficient of Thermal Expansion per F.
Specific Heat (BTU/lb. F.) (@ 77F.)
Thermal Conductivity BTU/hr./tt./F.
Bulk Modulus (Room temp. 1000-6000 psi) Solubility in water
PYORAUl 30E
Clear Blue Liquid
1.150-1.170
0.15
0.10%
PYORAUL 90E
Clear Blue Liquid
1.145-1.165
0 15
0.10%
PYORAUL 115E
Clear Blue Liquid
1.145-1.165
0.15
0.10%
30-34 4.6-5.0 150 SSU 42 SSU 173 SSU 47 SSU --15DF.
2.56 350F. 725F. 0.Q0035 0.36 0.0737 390,000 Negligible
85-95 7.7-8.1 415 SSU 52 SSU 473 SSU 57 SSU +10F.
2.53 350F. 805F. 0.00035 0.38 0.0723 396,000 Negligible
115-125 89-9.3 565 SSU 56 SSU 695 SSU 61 SSU + 1DF.
2.52 350'F. 820F. 0.00035 0.38 0.0721 397,000 Negligible
Table 2--Vapor Pressure
Temperature
Vapor Pressure mm Hg
C. F.
PYDRAUL 30E
PYDRAUL 90E
PYDRAUL 115E
rr
o! o
in
0 10 20 40 60 80 100 150 200
32 50 68 104 140 176 212 302 392
1.6 x 10-5 4.5 x 10 4 3.1 x 10" 1.4 x 10 3 5.6 x lO-3 2.0 x 10-
0.3 2.2
2.4 x 10 ` 8.0 x lO * 2.4 x 10 4 1.9 x 10 " 9.2 x 10 " 4.3 x 103 1.6 x 10-
0.25 2.0
1.0 x 10 h 3.8 x 10 1.1 X 10 4 1.0 x 10" 5.1 x 10" 2.6 x lO3 1.0 X 10?
0.2 1.8
Vapor Density:-. 11.2 compared to value for air of one (1).
Compatibility With Metals Pydraul air compressor lubricants are compati ble with all construction metals including alumi num, Aluminum load bearing surfaces should be hard-anodized for maximum equipment life.
0068220
TOWOLDMONOQ21563
Pydraul fact finder
FIRE RESISTANCE
Pydraul fire-resistant fluids and lubricants have worked in industry since 1951, providing many mil lions of machine hours of fire-free operation. Never since their introduction in 1954 has any Pydraul fireresistant compressor lubricant caused a compressor fire or explosion.
FIRE-RESISTANCE TESTS OF PYDRAUL 30E,
PYDRAUL 90E AND PYDRAUL 115E
TEST
High Pressure Spray Test AMS3150C and Federal Test Method St. 791. Test fluid sprayed at 1000 psi through orifice, pass ing through flame of oxyacetylene torch, 6000nF.
RESULTS
Does not flash or ignite up to 3Vz feet from orifice.
Atomized Spray Test (proce dure used by Factory Mutual Engineering Division). Test fluid healed to 140F. sprayed at 1000 psi from atomized cone type nozzle. A torch is passed through this spray 2 feet and ? to 6 inches from the orifice.
Local burning by torch at 6 inches and 2 feet from orifice. Flames self-extinguish imme diately when torch removed.
Hot Manifold Test (Federal Test Method Std. 791). Test fluid dripped on tube at 1300F.
Does not flash or burn.
Molten Metal Ignition Test. Test fluid exposed to the surface of aluminum alloy at 1200' F., to test for spontaneous ignition.
Does not ignite.
Figure 1--Typical Viscosities -- PYDRAUl30E -- PYDRAUL 90E
TOWOLDMONOQ21564
CONVERTING TO PYDRAUL IS EASY
QQb*lil
First, simply drain the petroleum oil and wipe the systems to operate af all capacities. For information
crankcase or lubricator.
on a Brink series suitable for your compressor sys
Thoroughly clean the exhaust valves and interstage tem, write to:
equipment before filling the crankcase or lubricator with Pydraul. Pydraul will loosen carbonaceous de
Monsanto Enviro-Chom Systems, Inc. 800 North Lindbergh Blvd.
posits. varnishes and sludge. Unless these loosened deposits are cleaned from the system, they could clog pipelines and components, requiring additional downtime and production loss. Once the valves have
St. Louis. Mo. 63166 Telephone: (314) 694-2286
(Joseph A. Brink)
been thoroughly cleaned of potentially dangerous SPECIAL CHECK FOR
carbon deposits. Pydraul lubricants will keep them clean--and let compressors run longer between maintenance shutdowns.
SPLASH-LUBRICATED COMPRESSORS
Crankcase paint. Pydraul air compressor lubricants will soften and loosen some paints from crankcase
STANDARD CHECK FOR COMPRESSORS--Plastic separator bowls. Not all plastic separator bowls are suitable for Pydraul service. Certain plastics are "crazed" or softened when exposed to Pydraul. Bowls made of
interiors. These paint particles could block the lubri cant passages. For this reason, it is a good practice to remove paint from crankcase interiors before Pydraul is added to the system. Standard paint removers are adequate for removing this paint.
glass, brass, steel, and these plastics--polycarbon ate. polyethylene, or nylon--are recommended for use with Pydraul, If you have a question regarding the resistance of a particular plastic, Monsanto will bo happy to advise you.
SPECIAL CHECK FOR FORCE-FEED LUBRICATORS
Sight-glass fluid. If a separate force-feed lubricator of the type normally filled with water and glycerine is used, one of two changes is necessary: either re
Diaphragm valves. Pydraul lubricants have a soften ing effect on neoprene and buna N rubber dia phragms normally used for petroleum oil service. Those diaphragms should be replaced with butyl rubber, EPR (ethylene propylene rubber), fluoroelastomer, silicone or other compatible elastomer ma terials resistant to Pydraul fluids. Diaphragm sheeting is available from normal sources of supply.
place the sight-glass fluid with one heavier than Pydraul or insert a metal bobber in the sight-glass, Pydraul fluids are heavier than water or glycerine and will not rise through these standard sight-glass liquids. Fluorochemical 101, a clear liquid supplied by the Minnesota Mining and Manufacturing Com pany, has a higher density than Pydraul and is a completely satisfactory replacement.
Metal bobbers. The alternate to using Fluorochemical
All diaphragms in unloading valves or downstream 101 is to modify the sight-glass lubricator by inserting
control valves should be replaced at the time of a simple metal bobber. The bobber is installed by
changeover. Diaphragms in valving downstream from draining the sight-glass liquid, removing the guide
j separator systems or drying systems need not be wire and inserting the bobber. Operation of the lubri
replaced at changeover time, but should be changed cator is then indicated by movement of the bobber
| on a preventative maintenance schedule as soon as with each stroke of the pump plunger instead of
practicable after operation on Pydraul is begun.
counting the drops as with guide wires. Bobbers are
For air compressors supplying air for instrumentation functions, mist eliminator systems are recommended to remove lubricant mists and moisture from air streams. A Monsanto development, a Brink6 mist
available for either McCord, Manzell. or Lincoln Engi neering lubricators. Modification of the MadisonKipp lubricator requires replacement of the entire sight-glass.
eliminator is a particularly effective system, available Vacuum-sight lubricators. Vacuum-sight lubricators
from Monsanto in a series of low-cost mist eliminator require no modification for Pydraul usage.
TOWOLDMONOQ21565
Pydraul fact finder
LUBRICATION DATA
MIXING COMPATIBILITY
DROP SIZE
Drop size of a lubricant is important to determine an adequate lubricant injection rate to insure proper compressor lubrication, The rate of lubrication is controlled by noting the drops per unit of time.
The drop size for the fluids tabulated below were determined by noting the number of drops formed at room temperature (75F.) on a 1 mm i.D. by ZVz mm O.D. glass tip. (Larger or smaller drops will result if different sized tips are used.)
Fluid
Medium weight petroleum oil Pydraul 90E
Drops per cubic centimeter
33 39
When installing new equipment, it is best to start with an increased lubricant feed rate and reduce this rate by successive increments. Inspection of cylinder walls and valves will indicate the proper degree of wetting.
Pydraul 30E, Pydraul 90E and Pydraul 115E are com pletely miscible in all proportions with competitive synthetic phosphate ester lubricants.
Table 3 Falex Wear Test
Pydraul'"' 30C Pydraul 90C Pydraul 115E
WT. LOSS,
wr. LOSS, PIN (mg.) BLOCKS (mg.)
0.1 0.2
0.7 10
1.0 0.3
Table 4
Shell Four-Ball Wear
(167 F., 1 hour, 630 rpm., mm scar diameter)
STEEL ON STEEL
PYDRAUL 30E
PYDRAUL 90E
A kg
0.47
0.28
10 kg
0.50
0.32
40 kg
0.64
0.54
STEEL ON BRONZE
10 kg
0.46
0.35
40 kg
0.97
0.65
PYDRAUL 115E 0.29 0.39 0.56
0.45 0.66
TOWOLDMONOQ21566
USES BY MAJOR MANUFACTURERS
New air compressors of most types and sizes pro duced by major compressor manufacturers can be manufactured for lubrication with Pydraul. The manu facturers listed (below) have manufactured compres sors equipped for Pydraul, upon specification of the buyer, for over ten years, Many compressors have operated on Pydraul lubricants continually with ex haust air temperatures of 350F. Pydraul is also used to lubricate cylinders in compressors operating at pressures over 4500 psig. American Messer Corporation Atlas Copco Bury Compressor Company Carrier Corporation Chicago Pneumatic Tool Company Clark Brothers Company,
division of Dresser Industries Cooper-Bessemer Corporation DeLaval Steam Turbine Company Gardner-Denver Company Ingersoil-Rand Company Joy Manufacturing Company Kinney Manufacturing, division of
The New York Air Brake Company Norwalk Company, Incorporated Schramm, Incorporated Worthington Corporation
TOXICITY AND SAFE HANDLING
Acute animal studies indicate that the Pydraul E Series Fluids can be classed as practically non-toxic when considered as an industrial fluid. They are non-irritating when the skin is exposed to the fluid. However, this product should not contact or in any way contaminate food, animal feed, food products, food packaging materials, pharmaceuticals or any items which may directly or indirectly be ultimately ingested by humans. Any contact may contaminate these items to the extent that their destruction may be required.
Due to their low order of toxicity, the Pydraul E Series require no special handling precautions. However, as m handling any chemical, good hygienic procedures should be followed. In case of skin contact, wash off with soap and water. In the case of eye contact, flush with copious amountsofwater.
While Pydraul E Series (Pydraul C Series, also AC Series, Santosafe W/G) fluids pose no serious problems with respect to the environment, as a concerned supplier to industry, Monsanto urges the user to maintain a tight system, to correct leakage promptly and to exercise care in the handling and disposal of this and all other such products.
68^
TOWOLDMONOQ21567
CUSTOMER SERVICE CENTERS
AKRON. OHIO 44313 260 Springside Drive Montrose Development Park lei. (216) 666-4111
ATLANTA. GEORGIA 30339 320 Interstate North Parkway Suite 500 Tel. (404) 432-7111
BOSTON. MASSACHUSETTS 02149 Everett Station Tel. (617) 387-5010
CHICAGO. ILLINOIS 3158 Des Plaines Ave. Des Plaines, Illinois 60018 Tel (312) 296-6688
CINCINNATI. OHIO 45236 8041 Hosbrook Road 7el (513) 984-1100
DETROIT. MICHIGAN 500 Northland Towers West Southfield, Michigan 48075 Tel (313) 357-0910
HOUSTON, TEXAS 77027 1301 Post Oak Tower 5051 Westheimer Road Tel. (713) 621-9550
LOS ANGELES. CALIFORNIA 1401 Dove Street Newport Beach. California 92660 Tel. (714) 833-9150
NEW YORK. NEW YORK 10036 1114 Avenue of the Americas Tel. (212) 764-5000
ST. LOUIS, MISSOURI 63166 800 N. Lindbergh B/vd. Tel. (314) 694-1000
SAN FRANCISCO BAY AREA 2710 Lafayette Santa Clara, California 95052 Tel. (408) 243-0414
SEATTLE, WASHINGTON 98121 2112 Third Avenue Tel. (206) 622-4203
WILMINGTON. DELAWARE 19810 Suite 204, Bancroft Bldg. 3411 Si/verside Road lei (302) 478-4600
Monsanto Industrial Chemicals Co. A Unit of Monsanto Company 800 N. Lindbergh Blvd., St. Louis, Mo. 63166
Monsanto
0068 22 5
liaik.v upon turnaiiiuo miormation or riicornmenaanons, ana disclaims ail naoiuty tor any resulting loss or damage."
TOWOLDMONOQ21568