Document L7eXEdJN6yJYR8RwyO2R41BQ
water heater performance-rating
... tailor the heater to
exact home requirements
Now with this new easy-to-use performance-rating chart, you can specify a deluxe American-Standard water heater that won't run out of hot water... no matter what the family requirements may be.
HERE'S HOW: Simply fill in the performance-rating chart as it applies to the customer's home. The total indicates the maximum amount of hot water needed by this household in any peak-load 2-hour period. Compare this figure with the Arcoglas Deluxe per formance ratings (amount the heater will deliver in a 2-hour period), then specify the model rated immediately above the performance requirements of the household. For example, if the chart indicates that household requirements are 90 gallons, be sure to specify the G-40-DG rated at 97.
Remember, American-Standard Water Heaters are performance rated up to 25% higher than competitive water heaters with the same-size tank.
American-Standard Gas Water Heaters meet national safety requirements and are approved by the American Gas Association for operation with all gases. They are also approved for 180* water and may be used commer cially by adding a 180* approval name plate and changing the dial on the thermostat.
writ* (Ms (Ifurn ... in this column
HOUSEHOLD FACTOR dishwashing
sink (manual washing)
(fallens of Hr bet water needed in t-hr. peak parted)
6
automatic dishwasher
9
laundry tub
24
automatic clothes washer
57 (3 cycles)*
>
standard clothes washer
32
miscellaneous cleaning
2
miscellaneous hand laundry
8
each additional bathroom over XVi 8
PEOPLE FACTOR family of 4 or under each additional member each pre-school child In the family (for diapers, etc.)
ADDITIONAL FACTORS approximate size of home
(number of bedrooms)
3 or under 4 5 over 5
8 2
2 sub-total
for a salety fader add th# fetlearine parcantoea to the abeve sub-total
0% 10% 25% 40%
total
^average requirements of 14 leading washing machine manufacturers
/
features of gas water heaters
L built-in draft hood ... designed to fit within the overall water heater dimensions, this mod ern draft diverter eliminates low ceiling prob lems ... adds to attractiveness ... aids efficient combustion and heat transfer. Only on Arcoglas Deluxe ... conventional bell type draft hood on other models.
2. Kralastic Inlet tube . . . imparts no taste or odor to water... can be inserted on either side if installation needs require . . . introduces cold water at low point in tank.
3. thick insulation . . . heavy blanket of Fibergtas completely encircles storage tank and com bustion chamber . . . keeps hot water hot . . . assures economy.
4. glass-lined tank ... a rich protective coating of glass blankets the tank .. . stops corrosion in even the most aggressive water. Tank hydro statically tested to 353 pounds per square inch. Arcosteel models have new-process galvanized steel tanks.
5. center flue . . . battled to transfer maximum heat into tank . . . center location adds strength to construction.
6. magnesium anode . . . the principle ot elec trolysis is utilized as an added protection against corrosion. Comes in all models except Arcosteel Standard
7.100% safety controls... in case of fuel failure, pilot and burner go off automatically ... de signed for all gases... assured safe lighting all parts, including magnetic power unit, are easily replaceable in the home.
1. concealed attachments ... alt controls on Arcoglas Deluxe are concealed yet readily acces sible ... located in front on all models. Sediment faucet (not shown) within easy reach.
.9 combustion chamber gives more hot water .
.. .flame formed to heat in 360" circle... provides up to 25% more hot water than other same-sized tanks . . . sweeps across entire base of storage f tank . . . horizontal-venturi type single-port burner designed for extreme efficiency... made of cast iron for ruggedness . . . clean flame is noiseless.
IQ. radiation shield... reflects heat into storage tank that otherwise would be lost . . . keeps "start-up" condensation off the floor . . . aids overall heater efficiency.
11. solid ring-type base . . . more attractive appearance . . . eliminates "dust bunnies" under the heater. On Arcoglas Deluxe only . . . conventional leg supports on all other models.
optional 2-temperature hot water . . . get laun dry-hot water for washing clothes . . . comfort ably hot for bathroom use with the special 2-temperature hot water attachment.
11040
August l, 19^9
gas water heaters
Arcoglas Deluxe
Arcoglas Deluxe water heater is covered by a ten year pro tection plan including 100% warranty for the first five years and a pro-rated plan for the remaining five.
Arcoglas Delute ratings and data ter InstaltatlM at mi level ml m to UK loot
August 1 t969
model no.
G-30-DG G-40-DG G-S0-DG
G-65-DG
cop. at.
sat, mfg. A mixed gases
lapul btuti
recovery rate*
30 30,400 25.5 40 32.000 26.9 SO 40.000 33.6
54.400 45 7 65
48,000 40.3 (Mfg)
If (IMS
input btuh
25.600 28,000 36,000
recovery rate*
21.5 23.5 30.3
40,000 33.6
BS-1400 LP-elr gases
Input ' recovery bttfh } rate*
25,600 i 28,000 32.000 !
)
44,000 1 1
21.5 23.5 26.9
37.0
U.S. Gallons raised 100T. per hour
Arcoglas Standard
Backed by 10 year protection plan--rugged cast iron burner--glass coated tank--magnesium anode--rugged cast iron burner--thick Fiberglas insulation--100% safety controls.
model no.
G-20-AG G-30-AG G-40-AG G-50-SG
Arcoglas Standard ratings and data
lor installation at sea level and up to 2000 feet
cap. Ml-
If
net, mfg. A mixed gases
recovery ret#*
LP gases
input i racevery btuh j rote*
S2S-1400 LP-air gases
input | recovery btuh rate*
Mrform-
anee rating
20 26.000 1 21.8 30 32.000 | 26.9
40 37,000 j 31.1
50 50,000 ! 42.0
26,000 |
j32,000
35,000 : 45.000 ;
21.8 26.9 29.4 37.8
23,000 1 32,000 |
35.000 1 40,000 !
19.3 26.9 29.4 33.6
58 76 92 121
for installation at elevation of 2.000 to 5.000 feet (higher altitude rating should bo roducod at tho rat# of 4% for oach 1,000 foot abovo 5,000 foot)
model no.
G-20-AG G-30-AG G-40-AG G-SO-SG
, nal, mfg. A cep. t mixed gass gal. : input recovery 1
1 btuh i r.t.*
ill
LP gases
j US-1400 IP-air ! gases
recoveryi input recovery
rate*
btuh . rste*
20 t 20.800 j 17.5 i 20,800 ! 25,600 1 21.5 25,600
i 40 1 29.600 1 24.9 28,000
; 50 40.000 33 6 36,000
17.5 j 18,400 i 15.5 21.5 ! 25,600 1 21.5 23.5 | 28,000 23.5 30.3 ! 32.000 26.9
U.S. Gallons raised I00*f. per hour
11041
American-Standard
gas water heaters
Arcosteel Deluxe
Arcosteel Deluxe is covered by a five year protection plan, including a 100% guarantee for the first two years and a pro-rated plan for the remaining three years.
Arcosteel Deluxe ratings and data
for inauttatien at sea level and up te 2d00 feet
model no.
cap.
Mtn mfg. A
mixed gases
IP gases
S2S44M IP-aJr
gasea
Ptr*
Input recovery Input recovery Input recevery act btuh rate* btuh rates btuh rate* rating
G-20-AS
26,000 21.8 26.000 21.8 23,000 19.3
G-20-ASR 20 30.000 25.2
--
G-30-AS
32,000 26.9 32,000 26.9 32,000 25.9
G-30-ASR 30 38,000 31.9
--
--
--
--
G-40-AS
37,000 31.1 35,000 29.4 35,000 29.4
G-40-ASR 40 40,000 33.6
--
--
--
--
G-SO-OS SO 50,000 42.0 45.000 37.8 40,000 33.6
S3 <5
76
as
92 97
121
for fnstatiatfon at elevatien of tOM to S,M feet (higher attitude rating should he reduced at the rate of 4% for each 1<000 feet above MOO feet)
model ne.
G-20-AS G-20-ASR G-30-AS G-30-ASR G-40-AS G-40-ASR G-50-DS
cap. i.
30 40 50
naL. mfg. & mixed gases
U> |IHI
input recovery | Input recovery
btuh
rate* | btuh
rate*
20.800 17.5 20,800 17.5
24.000 20.2
--
--
25,600 21.5 25.600 21.5
30.400 25.5
*
--
29,600 24.9 28.000 23.5
32,000 26.9
--
--
40,000 33.6 36.000 30.3
SZS-1400 LP-elr gasas
input recovery
btuh
rate*
18,400 --
15.5 --
25,600 --
28.000 --
21.5 --
23.5 --
32,000 26.9
U.S. Gallons raised 100*F. per hour
Arcosteel Standard
Arcosteel Standard is performance rated to deliver all the hot water you need--Fiberglas insulation--100% shut-off controls--carries a one year factory warranty.
Arcosteel Standard ratings and data
for InstsUatien at saa level and up to 2.000 feet
medal no.
G-20-SS G-30-SS G40-SS
cap. i.
nat, mfg. 4 mixed gases
input 1 recovery btuh i rate
LP gases
input (recovery btuh rate*
S2S*140Q LP-alr
gases
per-
input Irecovery | anee btuh | rate* rating
20 26,000 I 21.8 26.000 21.8 23,000 i 19.3 30 32.000 1 26.9 32.000 26.9 32,000 ! 26.9
40 37,000 1 31.1 35.000 29.4 35,000 1
58 76 92
for IfttUllalien at elevation of 2.000 to 9,000 feet (higher altitude rating should be reduced at the rate ef 4% for each 1.000 feet above 9,000 feet)
model no.
G-20-SS G-30-SS G-40-SS
cap.
.
20 30 40
naC, mfg. 4
IP |IHI
input irecovery btuh ! rate *
20.800 i 25,600 | 29,600
17.5 21.5 24.9
It
a
recovery rates
20,800 1
25,600 I 28.000 1
17.5 21.5 23.5
iH-1400 U>-*lr gases
input recovery
btuh
rates
18.400 25.600 28,000
15.5 21.5 23.5
features of electric water heaters
L. heat trap . . . outlet connection at top of tank traps hot water at the hottest point in the heater, and aids efficient operation by eliminat ing cooling effects through unnecessary water circulation.
2. magnesium anode___a feature on all glasslined models ... acts as a double check against corrosion, using the principle of electrolysis.
3. glass-lined tank ... a rich protective coating of glass blankets the tank ... stops corrosion in even the most aggressive water. Tank hydro-, statically tested 3S3 lbs. per square inch. Arcosteel models have new-process galvanized steel
tanks.
.4 thick Insulation ... heavy blanket of Fiberglas
completely encircles storage tank and combus tion chamber . . . keeps water hot. . . assures economy.
5. fast-reacting thermostats . . . each heating
element is equipped with an automatic thermo
stat which turns off electricity instantly when
desired water temperature is reached. For added
safety, high-temperature limit switch (optional)
will shut off current at predetermined high
temperature.
__
electric water heaters
6. heating elements... meet local electric utility rules. Heaters are equipped with one or two elements ranging from 600 to 5000 watts. Through direct contact with water, each element produces full value from every KWH (Kilowatt hour).
7. smooth cold water entry ... water enters at the low point in the tank through a baffled inlet This prevents any cold water dilution of heated water.
t. handy drain faucet... placed at lowest point in tank ... for your convenience it is provided with pipe threads to fit standard hose con nections.
.9 solid base ... provides greater strength and
support ... is easier to install . . . eliminates dust under the heaters.
all wiring to junction box ... installation is sim plicity itself. The heater is completely wired at the factory. The only electrical work needed is from the junction box to the house current.
now the convenience of 2-temperature water... hot water (11(T) for the bathroom--hotter water (150) for the laundry can easily be accomplished by specifying the new optional American-Stand ard 2-temperature hot water attachment.
Arcoglas Deluxe
Consider the wonder of electricity for quiet modern heat... the protection of glass lining for long, long tank life ... and the thermos effect of Fiberglas insulation for holding every degree of heat. Add the dependability of new thermostatic controls to provide exact desired water temperature ... the security of a 10-year warranty to exemplify American-Stand ard faith in a superior product.. . and the sound principle of Performance-Rating, for assuring the correct water heater to meet your specific needs. Combine all these and a host of other new features and you have the finest, new est electric water heater on the market . . . the all-new American-Standard Arcoglas Deluxe Electric.
Arro<ila<i Dnlurn r.itinn^ .tnrl data
model no.
E;301-DGR* E-302-DGR' E-521-DGR* E-522-DGR' E-W1-DGR* E-662-OGR* E-S21-DGR* E-J22-DGR*
1 cap. tank flal. 1 diam.
: so i 161
l 52 ; is-
66 ' 20"
82 : 20-
standard input (wattage)
pri- seconmary dary
1500 600
2500 1000
J 1000 i
1
1500 ;
3000 1250
4000 1500
2000 2500
l ! 1 !
high input (wattage)
pri- secon* mary dary
5000 5000
5000 5000
5000 5000
5000 5000
5000 5000 5000 5000
$tngle element ?J0 volt a c 'double element 2JO volt a.c. per element
August 1 19S9
'^J.vAmericaN'-^Standard
11043
electric water heaters
Arcosteel Standard
To Keep electricity bills at a minimum, accurate thermo static controls instantly shut off heating elements when the exact desired water temperature is reached. And to keep the hot water hot a thick coating of Fiberglas insula tion encircles the tank. For your convenience, the Arcosteel Standard Electric is available with one or two heating ele ments . . . any wattage up to 5,000, depending on local utility regulations.
And now through Performance-Rating, a new scientific approach to specifying the right electric water heater for each home, you can be sure of a constant hot water supply with the Arcosteel Standard.
The Arcosteel Standard Electric is covered by a ten-year protection plan.
Arcosteel Standard ratings and data
model no.
E-301-SSR* E-302-SSR" E-401-SSR* E-402-SSR" E-521-SSR* E-S22-SSR* E-M1-SSR* E-662-SSR' E-821-SSR* E-822-SSRT
standard Input high Input
cap. Unk
(watted)
(wattapa)
i. diem. pH- con- pH- mcoo-
miry dary mary dary
30
16'
1500 5000 600 1000 5000 5000
40
16*
2000 5000 750 1250 5000 5000
52
18"
2500 5000 1000 1500 5000 5000
66
JO*
3000 5000 1250 2000 5000 5000
82
20*
4000 5000 1500 2500 5000 5000
single element 230 volt ax.
double element 230 volt ax. per element
Tabletop Deluxe
Created for contemporary living, the Tabletop Deluxe is the perfect solution to modern design ... a minimum-height water heater with a functional work surface, in both glasslined and galvanized tanks.
The porcelain top is optional. With it the heater stands at the standard 36" work surface height. . . without it, this Deluxe heater can be smoothly integrated into a line of base cabinets under a continuous counter top.
And both of these practical models are covered by a 10year warranty... electric heating elements and thermostats for quiet efficient operation . . . and extra-thick Fiberglas insulation to keep electricity bills at a minimum.
Tabletop Deluxe ratings and data
model no.*
E-301* E-302* E-401* E-402* E-501* E-502 "
cap. gal.
30 40 50
tank diam.
20* 22" 22"
standard input (wattage)
pri secon mary dary
1500 600 1000
2000 750
1250
2500 1000
1500
high input (wattage)
pri secon mary dary
5000 5000
5000
5000 5000
5000 5000
5000 5000
designate tank type desired by adding suffixes DGT for glass lined tanks, OST tor galvanized steel tanks
single element 2JO volt a c double element 210 volt a c. per element