Document L79xm4ZzKJx6RLaB3DBw6gEb
FILE NAME Quigley QUIG
DATE 0000 DOC QUIG049
DOCUMENT DESCRIPTION Industry Warning Information
SPECIAL
REPORT
pe
OSHA OSHA STANDARDS AND
THE USE OF ASBESTOS
. The following description is provided to acquaint users of asbestos based
insulating materials with the latest OSHA Standards
OSHA has determined that contact with asbestos fiber is a serious health
hazard
The standard states
In view of the undisputed grave consequences from exposure to asbestos
fibers it is essential that the exposure be regulated now on the basis
of the best evidence available now even though it may not be as good
as scientifically desirable
An asbestos standard can be reevaluated
in light of the results of ongoing studies and future studies but
cannot wait for them
Lives of employees are at stake
The above asbestos
paragraph In fact
in essence sets the tone of the entire OSHA standard OSHA considers asbestos a serious enough material to
a separate section devoted to it
for have
Refractories QUIGLEY COMPANY INC Insulations
09 0965
The particular section covering asbestos is 1910.93a under Air Borne
Contaminants Section 1910.93
The threshold limit valve TLV for asbestos on an hour time weighted average
is no air
more than 5 To measure
fibers longer 5 than micrometers per cubic centimeter of
if the TLV is exceeded samples shall be collected within the
breathing zone of the employees on a membrane filter of 0.8 micrometer porosity
mounted on an open filter holder
Determination of the asbestos level is
made at a magnification of 400-450 with phase contrast illumination
We are not very far into the standard and already terms are being encountered
which will create confusion as to what is being said
In essence the standard
is saying not to use asbestos based materials
If you decided to use asbestos
based materials the possibility of exceeding the TLV is so probable that the
appropriate precautions have to be taken The precautions are as follows
a All hand operated and power operated tools which may release
asbestos cutting insulating block shall be provided with
local exhaust ventilation systems which will maintain the
.
concentration below the TLV
b Insofar as practicable asbestos shall be handled mixed
applied removed cut scored or otherwise worked in a wet
.
state sufficient to prevent emmission of airborne particles
c
No asbestos cement mortar coating grout plaster or similar
material containing asbestos shall be removed from bags cartons
or other containers without being either wetted or enclosed or
ventilated to prevent release of airborne asbestos fibers
The three sections above although making compliance somewhat awkward do not create
a condition which is impossible to work
However the next section in our opinion
is
to
the key feature of the
users
The assumption
standard and probably creates the greatest
is that whatever asbestos based insulation
frustration goes on must
eventually come off and with that in mind the following section governs
Spraying demolition or removal - Employees engaged in the spraying
of asbestos the removal or demolition of pipes structures or equip-
ment covered or insulated with asbestos and in the removal or demolition
of asbestos insulation or coverings shall be provided with respiratory
equipment in accordance with and with special clothing in section
paragraph d 2 iii of this section accordance with paragraph d 3 of this
1 .
What this section has
centimeter completely ment and clothing
done in and has
effect has discarded directed the user to
the
use
TLV of 5 fibers per certain respiratory
cubic equip-
09 0966
In simple terms the respiratory equipment referred to is a supplied
pe
: respirator either continous or pressure demand type
These types of respirators have an external source of air which the employee
breathes
The external source is either from a pressure tank or via air hoses
to the respirator The special clothing includes coveralls head covering
gloves and containers
foot covering The employer for each employee to isolate
shall provide two separate the contaminated clothing
lockers or Laundering
of contaminated clothing shall be done to prevent the release of airborne asbestos
fibers
If laundering is to be done by others the clothing shall be conveyed to
the launderer in sealed impermeable containers and informed the clothing is
contaminated with asbestos fibers
In addition to the above other items in the standard state
a
Posting of caution signs in areas where asbestos is being used
b
Waste disposal in sealed containers
c Exposure records on each employee
.
d
Employees to have reasonable access to any record required to
be maintained
e Notice to employee in writing if he has been exposed to airborne concentrations of asbestos in excess of the limits prescribed
It is obvious that the standard considers asbestos as a hazardous material and if a company is to use it it has to comply with some very strict regulations As noted some of these regulations are so restrictive that it creates extreme diffciulty as well as delays in completing projects
It is the considered opinion of the QUIGLEY COMPANY that no major modifications
based on relaxing these standards will be forthcoming in the future
It is in
fact our opinion that these standards will be enforced with increasing vigor
the end result being the complete elimination of the production and use of
insulations mortars fireproofing materials which contain asbestos
The QUIGLEY COMPANY has for many years produced high temperature castable
insulations which were formulated with a limited but apparent asbestos content
Two of the most recognized and popular of these materials have been PANELAG and
INSULAG Upon realizing the obvious end result to be imposed by OSHA QUIGLEY
immediately instituted a crash program directed toward designing these materials
so as to avoid confliction with the standards
We are happy to report after
extensive field testing that of insulating materials which
our not
efforts have resulted in a product line only meet the OSHA standards but also surpass
our original expectations in performance and realiability
nn
dd on)
the The QUIGLEY COMPANY now offers for use by all industries following ultra-
2
light high temperature ASBESTOS insulating products
^'
PRODUCT
TYPE
SERVICE LIMIT
|
PANELEX BLOCK
Formed Block
2000 F
PANELEX T.P.
Castable Insulation
2000 F
PANELEX SUPER
Castable Insulating Refractory
2200 F
PANELCOTE
Castable Insulation
2000 F
INSULAG A.F.
Castable Bloating Insulation _
2000 F
For technical information
of application concerning
regarding the physical properties uses and methods
these products contact your QUIGLEY representative
.
JUIGLEY COMPANY INC | S>UBSIDIARY OF PFIZER INC _
235 East 42nd Street New York N.Y. 10017 Tel 212 573-3444
09 0968