Document L2ZGRy0EqNmz1d9bqMzXDNJ7

(Ptf' 0> f INDUSTRIAL HYGIENE MONITORING DATE: PROJECT: June 30, 1987. Monitor insulator for asbestos exposure while stripping insulation using a glove bag. Second level Rectification Tower - Silanes. DATE OF SAMPLES: SUMMARY: 4/21/87 SAMPLE Z-9208 TYPE BZ TIME START 11:07 TIME STOP 11:30 MINUTES 23 VOLUME 92 1 C0NC. PEL <0.05 fibers/ cc 0.2 f/cc A * Airline ^BZ Breathing Zone RECOMMENDATIONS: DISCUSSION: Share this information with insulators. The insulator's exposure was well below the TWAg of 0.2 fibers/cc for asbestos. Continue using proper procedure. METHOD OF ANALYSIS: DATA AND REPORT BY: Microscopy * C. R. McMillan/T. L. Grittie r ANALYSIS BY: JHM Labs COPY TO: D. G. Beddow, D. A. Boggs, A. A. Cosper, E. L. Doerflein, J. K. Kyle, R. P. Leichliter, K. B. Purinton, W. V. Summers, G. W. Wulfert. RESP7 A TLG/le 5605A UCC 007233 INDUSTRIAL HYGIENE RESULTS DATE: r-ROJECT: July 1, 1987. Monitor K-57 area and personnel in area for exposure to asbestos. Painters had used air to blow dirt off of the top of ventilation ductwork in preparation for painting to be done. IH took a bulk sample of material which had been blown off the ductwork. Upon analysis, it was determined that the sample contained a small amount of asbestos. According to Poly II operators, the area had been quite dusty while the painters were working. After IH had been called, the painters were told to stop the operation. DATE OF SAMPLES: SUMMARY: SAMPLE Z-9218 DATE 4-23 TYPE Area Z-9219 4-23 Area 4/23/87 to 4/24/87 TIME START STOP 11:05 13:00 11:08 13:00 MINUTES RESULTS COMMENTS 115 <0.01 f/cc Desk at SW wall near K-57. Kettlehouse No one in area. 112 0.005 f/cc Near K-57 handhole. No one in area Z-9220 4-23 BZ 13:00 18:00 300 0.10 f/cc Insulator performing cleanup of K-57 area Z-9206 4-24 Area 00:10 8:25 495 <0.005 f/cc After cleanup completed. On breaker box at wall of kettle area Z-9207 4-24 BZ 9:54 10:50 56 <0.004 f/cc Operator performing regulator duties at K-57. Protective equipment was worn. BZ Breathing Zone DISCUSSION: f All samples show concentrations below both the TWAg and the TWAj^. Sample Z-9220 was taken during cleanup and is at the action level of a TWAg. The insulator wore protective clothing and an airline respirator. Samples Z-9206 and Z-9207 were taken after cleanup completion and priority analyzed to determine if the area was cleaned adequately to allow entry. The results of analysis were communicated over the phone and at approximately 2:00 p.ra. on the 24th the area was opened for entry. UCC 007234 ( ^COMMENDATIONS: METHOD OF ANALYSIS: DATA AND REPORT BY: ANALYSIS BY: COPY TO: Before air is used on dusty areas it should routinely be checked for asbestos content to avoid similar situations in the future. If anyone suspects asbestos in a dusty area I.H. should be called immediately. Share these results with all affected personnel. Microscopy C. R. McMillan/T. L. Grittie JHM Labs D. A. Boggs, E. L. Doerflein, J. K. Kyle, D. L. Mullins, K. B. Purinton, R. D. Smith, W. V. Summers, G. W. Wulfert. 5619A r UCC 007235 [JJiJsO-} >Of> INDUSTRIAL HYGIENE MONITORING DATE: PROJECT: DATE OF SAMPLES: 6/30/87 Routine area monitoring for asbestos on first level of Rectification Tower (N.W. side) in Silanes. 4/1/87 SUMMARY: SAMPLE TYPE TIME START STOP MINUTES FLOW RATE VOLUME CONC. 2-9149 Area RECOMMENDATIONS: 13:36 16:15 159 4000 636 1 40.008 cc/min. Share this information with area personnel. PEL TWA12 0.133 f/cc DISCUSSION: The concentration of asbestos in the Rectification Tower during the sampling period was well below the TWA12 PEL of 0.133 f/cc. METHOD OF ANALYSIS: DATA AND REPORT BY: ANALYSIS BY: Microscopy C. R. McMillan/T. L. Grittie JHM Labs COPY TO: D. G. Beddow, D. A. Boggs, A. A. Cosper, E. L. Doerflein, R. P. Leichliter. TLG/le 5607A UCC 007236 INDUSTRIAL HYGIENE RESULTS SUBJECT: DATE OF SAMPLES: SUMARY: SAMPLE TIME START STOP Z-8969 Z-8970 9:50 9:52 12:52 12:52 DISCUSSION: , RECOMMENDATIONS: METHOD OF ANALYSIS: DATA AND REPORT BY: ANALYSIS BY: COPY TO: June 30, 1987. Monitor UCC Design and Construction insulators for exposure to asbestos during removal using a glove bag. In Polymers I tank farm in area outside, behind 8" mill. 2/13/87 TOTAL (Min.) FLOW RATE VOLUME TYPE RESULTS PEL 182 3900 cc/min 709.8 1 BZ 180 4000 cc/min 720 1 BZ 0.22 f/cc 0.09 f/cc 0.2 f/cc 0.2 f/cc During the three hour sample period one of the insulators (sample #Z-8969) exceeded the TWAg permissible exposure limit of 0.2 fibers per cubic centimeter of air. Protective clothing and Comfo II half-face respirators with HEPA filters were worn. The respirators were more than adequate to protect against these fiber concentrations. Wet methods were used. The area in which the work was being performed was a small, cramped corner with little room for free movement. This may have contributed to the above results. Use caution when removing asbestos using the glove bag method. Wet methods of removal must be stringently enforced even when used in glove bags. Continue wearing respiratory protection when using the glove bag method. Continue 1H monitoring. Inform insulators of the results of these tests. Microscopy C. R. McMillan/T. L. Grittie JHM Labs D. A. Boggs, J. E. Boley, E. L. Doerflein, T. K. Ioannou, K. B. Purinton, L. P. Smith, S. M. Walker, G. W. Wulfert. L 5598A UCC 007237 U)D'0-v->o INDUSTRIAL HYGIENE RESULTS DATE: PROJECT: DATE OF SAMPLES: July 1, 1987. Monitor area near exposed asbestos on vertical line on fourth deck of east side of Rectification tower, Silanes. 4/29/87 SUMMARY: SAMPLE Z-9223 TYPE Area TIME START STOP 9:38 16:04 MINUTES 386 RESULTS <0.003 f/cc DISCUSSION: The sample pump was placed approximately 1 1/2 ft. downwind from the exposed line. The concentration during the sample period of nearly 6 1/2 hours was well below the PEL TWAg and the action level. RECOMMENDATIONS: b Request IH monitoring when personnel are in the area and/or the potential for disturbing the asbestos exists. METHOD OF ANALYSIS: DATA AND REPORT BY: ANALYSIS BY: COPY TO: Microscopy T. L. Grittie JHM Labs D. G. Beddow, D. A. Boggs, A. A. Cosper, E. L. Doerflein, R. P. Leichliter. TLG/le / 5616A 1/ UCC 007238 DATE: INDUSTRIAL HYGIENE MONITORING June 20, 1987. PROJECT: DATE OF SAMPLES: SUMMARY: SAMPLE 2-8973 TYPE Area IH monitoring was requested as a result of concern over potential asbestos exposure in the Monomers control room. This concern was raised when it was found that loose insulation had dropped onto the roof of the building near the ventilation system intake. 2/13/87 TIME START STOP 11:02 18:52 MINUTES 470 FLOW RATE 3050 cc/min. VOLUME CONC. 1433.5 1 <0.003 fibers/ cc TWA8 0.133 f/cc RECOMMENDATIONS: Report these results to operators and staff in Monomers. DISCUSSION: METHOD OF ANALYSIS: DATA AND REPORT BY; ANALYSIS BY: COPY TO: Operators should be commended for bringing this situation to the attention of I.H. Fiber concentrations were well below the 12-hour time weighted average PEL. Continued recognition/ reporting/monitoring and correction of possible problem situations is strongly encouraged. Microscopy C. R. McMillan/T. L. Grittie JHM Labs D. G. Beddow, D. A. Boggs, A. A. Cosper, E. L. Doerflein, R. P. Leichliter. TLG/lej/'' 5609A UCC 007239 I'uU'0>^7 INDUSTRIAL HYGIENE MONITORING DATE: PROJECT: DATE OF SAMPLES: June 30, 1987. Monitor area N.E. of tank farm number 3 in Silanes for asbestos. White fibers were seen floating in the air. These fibers were never identified. Area sampling was performed upon request. 3/24/87 SUMMARY: SAMPLE TYPE TIME START STOP MIN. FLOW RATE VOLUME CONC. TWA 12 Z-9109 Area 10:48 13:48 300 3050 915 1 <0.005 0.133 cc/min f/cc fibers/cc RECOMMENDATIONS: Communicate results to area personnel. DISCUSSION: Concentrations during the sampling period were well below the TWA^2 PEL for asbestos. This is based on the assumption that the material was asbestos even though it was never identified. Caution should be used when making such assumptions. METHOD OF ANALYSIS: Microscopy DATA AND REPORT BY: C. R. McMillan/T. L. Grittie ANALYSIS BY: COPY TO: JHM Labs D. G. Beddow, D. A. Boggs, A. A. Cosper, E. L. Doerflein, R. P. Leichliter. TLG/le 5608A iX UCC 007240 UJV'O c DATE: INDUSTRIAL HYGIENE RESULTS July 1, 1987. PROJECT: Monitor Poly I control room for exposure potential to asbestos. Asbestos insulation is above the ceiling tiles and concern was expressed over the potential for a hazard to exist in the control room. DATE OF SAMPLES: 4/29/87 SUMMARY: SAMPLE TYPE LOCATION TIME START STOP MINUTES RESULTS PEL TWA12 2-9221 Z-9222 Source Area Next to crawl space near missing ceiling tile above Bailey Operators desk 9:20 16:10 ** 410 98 <0.003 f/cc 0.01 f/cc 0.13 f/cc 0.13 f/cc *The pump shut off at some point during the sampling but ran for 98 minutes at the flow rate. $ ISCUSSION: Both samples were below the TWA^2 PEL as well as the action level. RECOMMENDATIONS: METHOD OP ANALYSIS: DATA AND REPORT BY: ANALYSIS BY: COPY TO: Conduct personnel monitoring for operator spending the most time in that area. Share the above results with personnel in that area. Notify IH if the ceiling tiles are to be removed. Microscopy T. L. Grittie JHM Labs D. G. Beddow, D. A. Boggs, E. L. Doerflein, T. K. Ioannou, J. K. Kyle, L. P. Smith. TLG/ie / 617A ^ UCC 007241 U)U^O~> >& t/7? ( DATE: PROJECT: INDUSTRIAL HYGIENE RESULTS July 1, 1987. Monitor insulators for asbestos exposure while using glove bags to strip T-lll in Tank Farm 4 in Silanes. DATE OF SAMPLES: SUMMARY: SAMPLE 2-9225 2-9226 TYPE B2 B2 4/30/87 TIME START STOP 12:54 13:34 12:57 13:34 MINUTES 40 37 RESULTS 0.14 f/cc <0.03 f/cc PEL TWA8 0.2 f/cc 0.2 f/cc DISCUSSION: RECOMMENDATIONS: During the short sample time the fiber concentrations were below the PEL TWAg of 0.2 f/cc. Sample 2-9225 was slightly above the action level. Due to the short duration of sampling neither are truly indicative of an 8 hour exposure. The insulators wore breathing air. Glove bag method was' used. Share this information with insulators. Continue to request I.U. monitoring. METHOD OF ANALYSIS: DATA AND REPORT BY: ANALYSIS BY: COPY TO: Microscopy C. R. McMillan/T. L. Grittie JHM Labs D. G. Beddow, D. A. Boggs, A. A. Cosper, E. L. Doerflein, J. K. Kyle, R. P. Leichliter, K. B. Purinton, W. V. Summers, G. W. Wulfert. TLG/le 5618A V UCC 007242 (I)il'0-\7 DATE: PROJECT: DATE OF SAMPLES: SUMMARY: SAMPLE Z-9050 Z-9051 Z-9052 TYPE BZ BZ BZ INDUSTRIAL HYGIENE RESULTS June 30, 1987. Monitor insulators for asbestos exposure while removing insulation from Emulsion Building, Polymers II. 2/15/87 and 2/17/87 DATE 2/15 2/15 2/17 TIME START 13:15 13:17 10:30 TIME STOP 14:20 14:20 11:30 MINUTES 65 63 60 RESULTS COMMENTS <0.02 f/cc 0.09 f/cc 0.68 f/cc Glove Bag Glove Bag Inside negative pressure enclosure BZ = breathing zone DISCUSSION: RECOMMENDATIONS: METHOD OF ANALYSIS: DATA AND REPORT BY: ANALYSIS BY: COPY TO: All insulators monitored wore airline respirators. Aa one can see from the above data, the use of glove bags where feasible, significantly reduces personnel exposure and should be the engineering control of choice if possible. Sample Z-9052 shows a fiber concentration above the PEL, TWAg of 0.2 f/cc during the sampling period. This concentration is, however, well below the limitations of the respirator. Use glove bagB whereever feasible. Regardless of the method of choice, the material must be thoroughly wetted to minimize fibers in the air. Share thiB information with insulators. Microscopy C. R. McMillan/T. L. Grittie JHM Labs D. A. Boggs, E. L. Doerflein, J. K. Kyle, D. L. Mullins, K. B. Purinton, W. V. Summers, G. W. Wulfert. TLG/le 5601A UCC 007243 iUi/'O > -io**3! ATE: INDUSTRIAL HYGIENE MONITORING June 30, 1987. PROJECT: Monitor insulators for asbestos exposure while patching exposed insulation on T-3 methyl chloride tank in Monomers. DATE OF SAMPLES: 3/26/87 SAMPLE 2-9132 2-9133 2-9T34 TYPE B2 B2 B2 TIME START STOP MIN. 10:27 10:30 10:28 11:24 11:24 11:24 57 54 56 FLOW RATE (cc/min) 4000 4000 4000 VOLUME (liters) COKC. PEL TWA8 228 <.0.0022 f/cc 0.20 f/cc 216 0.03 f/cc 0.20 f/cc 224 <0.02 f/cc 0.20 f/cc RESP. A A A RECOMMENDATIONS: Share this information with the insulators DISCUSSION: All samples were well below the PEL during the sample period. METHOD OF ANALYSIS: DATA AND REPORT BY: ANALYSIS BY: COPY TO: Microscopy C. R. McMillan/T. L. Grittie JHM Labs D. G. Beddow, D. A. Boggs, A. A. Cosper, E. L. Doerflein, J. J. Kyle, R. P. Leichliter, K. B. Purinton, W. V. Summers, G. W. Wulfert. TLG/le 5610A UCC 007244