Document L2ZGRy0EqNmz1d9bqMzXDNJ7
(Ptf' 0>
f
INDUSTRIAL HYGIENE MONITORING
DATE: PROJECT:
June 30, 1987.
Monitor insulator for asbestos exposure while stripping insulation using a glove bag. Second level Rectification Tower - Silanes.
DATE OF SAMPLES: SUMMARY:
4/21/87
SAMPLE Z-9208
TYPE BZ
TIME START
11:07
TIME STOP
11:30
MINUTES 23
VOLUME 92 1
C0NC.
PEL
<0.05 fibers/ cc
0.2 f/cc
A * Airline ^BZ Breathing Zone
RECOMMENDATIONS: DISCUSSION:
Share this information with insulators.
The insulator's exposure was well below the TWAg of 0.2 fibers/cc for asbestos. Continue using proper procedure.
METHOD OF ANALYSIS: DATA AND REPORT BY:
Microscopy
*
C. R. McMillan/T. L. Grittie
r
ANALYSIS BY:
JHM Labs
COPY TO:
D. G. Beddow, D. A. Boggs, A. A. Cosper, E. L. Doerflein, J. K. Kyle, R. P. Leichliter, K. B. Purinton, W. V. Summers, G. W. Wulfert.
RESP7 A
TLG/le 5605A
UCC 007233
INDUSTRIAL HYGIENE RESULTS
DATE: r-ROJECT:
July 1, 1987.
Monitor K-57 area and personnel in area for exposure to asbestos. Painters had used air to blow dirt off of the top of ventilation ductwork in preparation for painting to be done. IH took a bulk sample of material which had been blown off the ductwork. Upon analysis, it was determined that the sample contained a small amount of asbestos. According to Poly II operators, the area had been quite dusty while the painters were working. After IH had been called, the painters were told to stop the operation.
DATE OF SAMPLES: SUMMARY:
SAMPLE Z-9218
DATE 4-23
TYPE Area
Z-9219
4-23
Area
4/23/87 to 4/24/87
TIME START STOP 11:05 13:00
11:08 13:00
MINUTES
RESULTS
COMMENTS
115
<0.01 f/cc
Desk at SW wall near
K-57. Kettlehouse
No one in area.
112 0.005 f/cc Near K-57 handhole. No one in area
Z-9220
4-23
BZ
13:00 18:00
300
0.10 f/cc
Insulator performing cleanup of K-57 area
Z-9206
4-24
Area
00:10 8:25
495
<0.005 f/cc
After cleanup completed. On breaker box at wall of kettle area
Z-9207
4-24
BZ
9:54 10:50
56
<0.004 f/cc
Operator performing regulator duties at K-57. Protective equipment was worn.
BZ Breathing Zone
DISCUSSION: f
All samples show concentrations below both the TWAg and the TWAj^. Sample Z-9220 was taken during cleanup and is at the action level of a TWAg. The insulator wore protective clothing and an airline respirator. Samples Z-9206 and Z-9207 were taken after cleanup completion and priority analyzed to determine if the area was cleaned adequately to allow entry. The results of analysis were communicated over the phone and at approximately 2:00 p.ra. on the 24th the area was opened for entry.
UCC 007234
( ^COMMENDATIONS:
METHOD OF ANALYSIS: DATA AND REPORT BY: ANALYSIS BY: COPY TO:
Before air is used on dusty areas it should routinely be checked for asbestos content to avoid similar situations in the future. If anyone suspects asbestos in a dusty area I.H. should be called immediately. Share these results with all affected personnel.
Microscopy
C. R. McMillan/T. L. Grittie
JHM Labs
D. A. Boggs, E. L. Doerflein, J. K. Kyle, D. L. Mullins, K. B. Purinton, R. D. Smith, W. V. Summers, G. W. Wulfert.
5619A
r
UCC 007235
[JJiJsO-} >Of>
INDUSTRIAL HYGIENE MONITORING
DATE: PROJECT:
DATE OF SAMPLES:
6/30/87
Routine area monitoring for asbestos on first level of Rectification Tower (N.W. side) in Silanes.
4/1/87
SUMMARY:
SAMPLE
TYPE
TIME START STOP
MINUTES
FLOW RATE
VOLUME
CONC.
2-9149
Area
RECOMMENDATIONS:
13:36 16:15 159 4000
636 1
40.008
cc/min.
Share this information with area personnel.
PEL TWA12
0.133 f/cc
DISCUSSION:
The concentration of asbestos in the Rectification Tower during the sampling period was well below the TWA12 PEL of 0.133 f/cc.
METHOD OF ANALYSIS: DATA AND REPORT BY: ANALYSIS BY:
Microscopy C. R. McMillan/T. L. Grittie JHM Labs
COPY TO:
D. G. Beddow, D. A. Boggs, A. A. Cosper, E. L. Doerflein, R. P. Leichliter.
TLG/le 5607A
UCC 007236
INDUSTRIAL HYGIENE RESULTS
SUBJECT:
DATE OF SAMPLES:
SUMARY:
SAMPLE
TIME START STOP
Z-8969 Z-8970
9:50 9:52
12:52 12:52
DISCUSSION:
, RECOMMENDATIONS:
METHOD OF ANALYSIS: DATA AND REPORT BY: ANALYSIS BY: COPY TO:
June 30, 1987.
Monitor UCC Design and Construction insulators for exposure to asbestos during removal using a glove bag. In Polymers I tank farm in area outside, behind 8" mill.
2/13/87
TOTAL (Min.)
FLOW RATE
VOLUME
TYPE
RESULTS
PEL
182
3900 cc/min
709.8 1
BZ
180
4000 cc/min
720 1
BZ
0.22 f/cc 0.09 f/cc
0.2 f/cc 0.2 f/cc
During the three hour sample period one of the insulators (sample #Z-8969) exceeded the TWAg permissible exposure limit of 0.2 fibers per cubic centimeter of air. Protective clothing and Comfo II half-face respirators with HEPA filters were worn. The respirators were more than adequate to protect against these fiber concentrations. Wet methods were used. The area in which the work was being performed was a small, cramped corner with little room for free movement. This may have contributed to the above results.
Use caution when removing asbestos using the glove bag method. Wet methods of removal must be stringently enforced even when used in glove bags. Continue wearing respiratory protection when using the glove bag method. Continue 1H monitoring. Inform insulators of the results of these tests.
Microscopy
C. R. McMillan/T. L. Grittie
JHM Labs
D. A. Boggs, J. E. Boley, E. L. Doerflein, T. K. Ioannou, K. B. Purinton, L. P. Smith, S. M. Walker, G. W. Wulfert.
L
5598A
UCC 007237
U)D'0-v->o
INDUSTRIAL HYGIENE RESULTS
DATE: PROJECT:
DATE OF SAMPLES:
July 1, 1987.
Monitor area near exposed asbestos on vertical line on fourth deck of east side of Rectification tower, Silanes.
4/29/87
SUMMARY:
SAMPLE Z-9223
TYPE Area
TIME START STOP
9:38 16:04
MINUTES 386
RESULTS <0.003 f/cc
DISCUSSION:
The sample pump was placed approximately 1 1/2 ft. downwind from the exposed line. The concentration during the sample period of nearly 6 1/2 hours was well below the PEL TWAg and the action level.
RECOMMENDATIONS: b
Request IH monitoring when personnel are in the area and/or the potential for disturbing the asbestos exists.
METHOD OF ANALYSIS: DATA AND REPORT BY: ANALYSIS BY: COPY TO:
Microscopy
T. L. Grittie
JHM Labs
D. G. Beddow, D. A. Boggs, A. A. Cosper, E. L. Doerflein, R. P. Leichliter.
TLG/le / 5616A 1/
UCC 007238
DATE:
INDUSTRIAL HYGIENE MONITORING June 20, 1987.
PROJECT:
DATE OF SAMPLES: SUMMARY:
SAMPLE 2-8973
TYPE Area
IH monitoring was requested as a result of concern over potential asbestos exposure in the Monomers control room. This concern was raised when it was found that loose insulation had dropped onto the roof of the building near the ventilation system intake.
2/13/87
TIME START STOP
11:02 18:52
MINUTES 470
FLOW RATE
3050 cc/min.
VOLUME
CONC.
1433.5 1 <0.003 fibers/ cc
TWA8
0.133 f/cc
RECOMMENDATIONS:
Report these results to operators and staff in Monomers.
DISCUSSION:
METHOD OF ANALYSIS: DATA AND REPORT BY; ANALYSIS BY: COPY TO:
Operators should be commended for bringing this situation to the attention of I.H. Fiber concentrations were well below the 12-hour time weighted average PEL. Continued recognition/ reporting/monitoring and correction of possible problem situations is strongly encouraged.
Microscopy
C. R. McMillan/T. L. Grittie
JHM Labs
D. G. Beddow, D. A. Boggs, A. A. Cosper, E. L. Doerflein, R. P. Leichliter.
TLG/lej/'' 5609A
UCC 007239
I'uU'0>^7
INDUSTRIAL HYGIENE MONITORING
DATE: PROJECT:
DATE OF SAMPLES:
June 30, 1987.
Monitor area N.E. of tank farm number 3 in Silanes for asbestos. White fibers were seen floating in the air. These fibers were never identified. Area sampling was performed upon request.
3/24/87
SUMMARY:
SAMPLE
TYPE
TIME START STOP
MIN.
FLOW RATE
VOLUME
CONC.
TWA 12
Z-9109
Area
10:48 13:48
300
3050
915 1
<0.005
0.133
cc/min
f/cc
fibers/cc
RECOMMENDATIONS:
Communicate results to area personnel.
DISCUSSION:
Concentrations during the sampling period were well below the TWA^2 PEL for asbestos. This is based on the assumption that the material was asbestos even though it was never identified. Caution should be used when making such assumptions.
METHOD OF ANALYSIS:
Microscopy
DATA AND REPORT BY:
C. R. McMillan/T. L. Grittie
ANALYSIS BY: COPY TO:
JHM Labs
D. G. Beddow, D. A. Boggs, A. A. Cosper, E. L. Doerflein, R. P. Leichliter.
TLG/le 5608A iX
UCC 007240
UJV'O
c
DATE:
INDUSTRIAL HYGIENE RESULTS July 1, 1987.
PROJECT:
Monitor Poly I control room for exposure potential to asbestos. Asbestos insulation is above the ceiling tiles and concern was expressed over the potential for a hazard to exist in the control room.
DATE OF SAMPLES:
4/29/87
SUMMARY:
SAMPLE
TYPE
LOCATION
TIME START STOP
MINUTES
RESULTS
PEL TWA12
2-9221 Z-9222
Source Area
Next to crawl space near missing ceiling tile above Bailey
Operators desk
9:20 16:10 **
410 98
<0.003 f/cc
0.01 f/cc
0.13 f/cc
0.13 f/cc
*The pump shut off at some point during the sampling but ran for 98 minutes at the flow rate.
$ ISCUSSION:
Both samples were below the TWA^2 PEL as well as the action level.
RECOMMENDATIONS:
METHOD OP ANALYSIS: DATA AND REPORT BY: ANALYSIS BY: COPY TO:
Conduct personnel monitoring for operator spending the most time in that area. Share the above results with personnel in that area. Notify IH if the ceiling tiles are to be removed.
Microscopy
T. L. Grittie
JHM Labs
D. G. Beddow, D. A. Boggs, E. L. Doerflein, T. K. Ioannou, J. K. Kyle, L. P. Smith.
TLG/ie / 617A ^
UCC 007241
U)U^O~> >& t/7?
(
DATE:
PROJECT:
INDUSTRIAL HYGIENE RESULTS
July 1, 1987.
Monitor insulators for asbestos exposure while using glove bags to strip T-lll in Tank Farm 4 in Silanes.
DATE OF SAMPLES: SUMMARY:
SAMPLE
2-9225 2-9226
TYPE
B2 B2
4/30/87
TIME START STOP
12:54 13:34 12:57 13:34
MINUTES
40 37
RESULTS
0.14 f/cc <0.03 f/cc
PEL TWA8
0.2 f/cc 0.2 f/cc
DISCUSSION: RECOMMENDATIONS:
During the short sample time the fiber concentrations were below the PEL TWAg of 0.2 f/cc. Sample 2-9225 was slightly above the action level. Due to the short duration of sampling neither are truly indicative of an 8 hour exposure. The insulators wore breathing air. Glove bag method was' used.
Share this information with insulators. Continue to request I.U. monitoring.
METHOD OF ANALYSIS: DATA AND REPORT BY: ANALYSIS BY: COPY TO:
Microscopy
C. R. McMillan/T. L. Grittie
JHM Labs
D. G. Beddow, D. A. Boggs, A. A. Cosper, E. L. Doerflein, J. K. Kyle, R. P. Leichliter, K. B. Purinton, W. V. Summers, G. W. Wulfert.
TLG/le 5618A V
UCC 007242
(I)il'0-\7
DATE: PROJECT:
DATE OF SAMPLES: SUMMARY:
SAMPLE
Z-9050 Z-9051 Z-9052
TYPE
BZ BZ BZ
INDUSTRIAL HYGIENE RESULTS
June 30, 1987.
Monitor insulators for asbestos exposure while removing insulation from Emulsion Building, Polymers II.
2/15/87 and 2/17/87
DATE
2/15 2/15 2/17
TIME START
13:15 13:17 10:30
TIME STOP
14:20 14:20 11:30
MINUTES
65 63 60
RESULTS
COMMENTS
<0.02 f/cc 0.09 f/cc 0.68 f/cc
Glove Bag Glove Bag Inside negative pressure enclosure
BZ = breathing zone DISCUSSION:
RECOMMENDATIONS:
METHOD OF ANALYSIS: DATA AND REPORT BY: ANALYSIS BY: COPY TO:
All insulators monitored wore airline respirators. Aa one can see from the above data, the use of glove bags where feasible, significantly reduces personnel exposure and should be the engineering control of choice if possible. Sample Z-9052 shows a fiber concentration above the PEL, TWAg of 0.2 f/cc during the sampling period. This concentration is, however, well below the limitations of the respirator.
Use glove bagB whereever feasible. Regardless of the method of choice, the material must be thoroughly wetted to minimize fibers in the air. Share thiB information with insulators.
Microscopy
C. R. McMillan/T. L. Grittie
JHM Labs
D. A. Boggs, E. L. Doerflein, J. K. Kyle, D. L. Mullins, K. B. Purinton, W. V. Summers, G. W. Wulfert.
TLG/le 5601A
UCC 007243
iUi/'O > -io**3!
ATE:
INDUSTRIAL HYGIENE MONITORING June 30, 1987.
PROJECT:
Monitor insulators for asbestos exposure while patching exposed insulation on T-3 methyl chloride tank in Monomers.
DATE OF SAMPLES:
3/26/87
SAMPLE
2-9132 2-9133 2-9T34
TYPE
B2 B2 B2
TIME START STOP
MIN.
10:27 10:30 10:28
11:24 11:24 11:24
57 54 56
FLOW RATE (cc/min)
4000 4000 4000
VOLUME (liters)
COKC.
PEL TWA8
228 <.0.0022 f/cc 0.20 f/cc
216
0.03 f/cc
0.20 f/cc
224
<0.02 f/cc
0.20 f/cc
RESP.
A A A
RECOMMENDATIONS:
Share this information with the insulators
DISCUSSION:
All samples were well below the PEL during the sample period.
METHOD OF ANALYSIS: DATA AND REPORT BY: ANALYSIS BY: COPY TO:
Microscopy
C. R. McMillan/T. L. Grittie
JHM Labs
D. G. Beddow, D. A. Boggs, A. A. Cosper, E. L. Doerflein, J. J. Kyle, R. P. Leichliter, K. B. Purinton, W. V. Summers, G. W. Wulfert.
TLG/le 5610A
UCC 007244