Document KzXO8gK0n2QRykdjzdjRDJx2Q
302
Heating System,
303
SID E.
PARKER BOILER
MFG. CO.
2035 E. 37th St.; Los Angeles 58, ADams 3-8263
NEVER A COMPROMISE FOR QUALITY OR SAFETY
Manufacturers of steel water tube boilers, steam and hot water, in accordance with the A-S.M.R. Code. AU units fully packaged, factory wired and fire tested, ready to connect to utilities and service lines. The high operating efficiency, simplicity of maintenance and long life of Parker Boilers has been proven by actual performance in thousands of installations including: schools, hospitals, churches, apartments, homes and industry.
PARKER HOT WATER BOILER manufactured in seventeen sizes from 126M to 5,000M B.T.U. A.C.A. approved np to 3.000M B.T.U. Designed for closed circait space heating systems using forced water circulation. AU welded flexible tube design eliminates thermal shock damage. Standardly famished A.S.M.E. 125 P.S-I- for tempera tures to 250*. Also available trimmed for high temperature water systems to 400*. Gas, oil and combination gas-oU fired.
PARKER INDIRECT HOT WATER BOILER manufactured in seven sizes from 264M to 1.416M B.T.U. or 254 to 1,274 gallons per hour 100* rise. The ideal boiler to provide rust free domestic hot water for hospitals, laundries, restaurants, apartments and heating swimming pools using the indirect water-to-water heat exchanger principle. AU welded steel construction with copper tube heat exchanger bolted into upper header. Gas fired only.
PARKER STEAM BOILERS eighteen sizes lVfi to 150 H.P. A.S.M.E. to 250 P.S.I. Widely used for low pressure steam building heating and applications requiring high pressure steam for processing. All models offer these distinct advantages:
1. Full steam pressure in less than 10 minutes
2. Compactness
3. Five square feet or more heating surface per boiler horsepower
MODEL HW'l'.HD 69 to 150 H.P.
4. Effectively insulated 5. Quiet operation
MODEL HWT-UD 5 to 40 H.P.
6. Tubing in sections easily replaced on job site if ever necessary
7. Complete accessibility for internal inspection
8. Controls are standard make sold and serviced in ternationally
9. Attractively finished reflecting superior workman ship
MODEL HWT-HD 7 to 50 H.P.
Gas, oil and combination gas-oil fired.
MODEL HWT-VD ltt & 3 JLP.
Descriptive literature and specifications promptly furnished on request.
GAS-FIRED UNIT HEATER
SPECIFICATIONS--FAN and BLOWER MODELS
Hester Number Pea Type
LUH 25A LUH. 50A
t(JH"75A LUH 100A
LUH 125A LUH 150A LUti 175A Lutf z66A LUH 225A LUH250A LUtTTTsA LUH 5O0A
Hester Number Bbver Type
LUHB 25A LUHB S5S
I.FIHH JSA
LUHB tOOS" LUHB 125A
Luhb isoa LUHB I75A UtHBWOA LUHB nsA "LUHB 2sSX " LUHB 275X T.UHB 300A
Hester Input Btu/hr
25.000 50.000 75.000
100.000 125.000
150.000 175.000
200 .AM 225 .AM 250.666 275.000 300.000
Hester
Btu/hr'
20.000 40.000 60.000 <0.000 100.000 120.000 16.000 106.000 iso.ooo 200.000 220.000 240.000
bp >/. '/ */ V7-
H
2.1/,. i-Vn i-W Fk
Car Inlet
NL LP
mid.
X' H` * W w vy wW ww
w \i`
w
i* 54* 1*
nV** 1*
-------- ^-------------- i
Equiv. diein.
Fhtt
y 4* S' 6* 6' 7' 8' 8' 9' 9' 10' lO'
SK?
72 128 tea 176 iii 2 >6 301 509 46i 4ii idi 578
UNI-MATIC gas-fired DUCT FURNACE
iuminized steel or stainless steel heat exchanger. Bypass, drip pan and other standard items are available.
$DFS SO 50.000 40,000 l DPS 75 75,000 60,000 : ;DFS 100 100,000 SO.OOO . DPS 125 125,000 100,000 -
Model Number
Input Btu/hr
Output Btu/hr
EDB
Flue Size
Weight
<**
Net Ship Net. LP
DF-150A 150.000 120.000 500 7 275 29S X X
DF-200A 200,000 160,000 666 8 314 340 X X
DF-250A 250.000 200,000 835 9 395 430 l
DF-300A 300,000 240,000 999 10 427 465 l
xhraun DropThru Furnace *HiO
SVleaiperalure Rise Tbru Furcece
DFS-50
SO.OOO Btu/hr
3 DFS-75
75.000 Btu/hr
3 DFS-100
100.000 Btu/hr
ift DFS-125
125.000 Btu/hr
^
Performance Data--DPS--Duct Pomaces
0.30' 0.21* 0.14* 0.11' 0.09'
30* 40* so* 60* 70*
1212 910 730 600 520
1820 1365 1090
9!0 780
2420 1820 1460 1200 1040
3100
2260
1830
1500
1280
Performance Data--DF--Duct Furnaces
0.07* 80* 455 680 910 1140
0.0S' 90* 400 600 800 1000
0.035' 100* 365 545 730 915
0.03 110* 330 N SOO ( ,,
660 { 3 tat>
^Presun DropTbru Furnace *H0
0.36'
KTempennire Rise Thru Furnace . 30*
i DF 150A 150.000 Btu/hr 3640
^ DF 200A 200,000 Btu/hr 4850
fjf DF 2S0A 250,000 Btu/hr 6060
$ DF 300A 300.000 Btu/hf 7280
0.25* 40* 2720 3640 4550. 5440
0.17* 50* 2180 2910 5650 4360
0.13' 60* 1820 2425 5050 3640
0.11* 70*
1560 2080 2600 3120
0-087' 80* 1360 1820 2275 2720
0.06' 90* 1210 1620 2020 2420
0.03' 100* 1090 1455 1820 2180
0.026' no*
1320 ( ,, io( 3 1980 '
DRAFTER
OzeAledSUNI-MATIC gas-fired DOWN BLAST
SPECIFICATIONS--DOWN BLAST HEATER
Order No.
DB-300 DB-400 DB-S00 DB-600
Btu Input
300,000 400,000 500,000 600,000
Btu Output
240,000 320,000 400,000 480,000
Fan Size Inches
24' 24' 30' 30'
Equiv. Dia. Round Flue
2-7' 2-8' 2-9' 2-10'
Gas Inlet Size
2-K' 1M* 2-r 2-1'
j?Power draft for all Peerless heating apgpliances. It assures positive draft under all econditions and is easier to install than {other venting.
Motors and controls that are suitable for any appUcation are furnished as stand ard equipment on Peerless Down Blast heaters.
COMPLETE CATALOG ON ALL PEERLESS EQUIPMENT AVAILABLE ON REQUEST
nm1DOVER CORPORATION PEERLESS MANUFACTURING DIVISION
{eg#
1$
. ,!;i! hlH;!
Si*: m