Hydronic Heating Equipment*
Hydromcs . . the science of heat.ng and cooling with water.
PRODUCTS
Boilers--Cast Iron Electric Packaged Boilers Gas-Packaged Units Non-Pkg Boilers Modular Boilers Miscellaneous Options Tankless Water Heaters Oil-Packaged Units Non-Pkg. Boiler Burner Units Boilers Only Miscellaneous Options Tankless Water Heaters Combustion Chambers (A-5) Pressure Fired Boiler Burner Units Oil Gas Gas/Oil Comb. Miscellaneous Options Tankless Water Healers
Oil Burners and Controls
Zone Valves
Hydronic Assembling Tools
Non-Ferrous Radiation Baseboard Panels--Heatrim '(Ot< vector--Multifin Cabinets
General Information
Repair Parts Reference
Terms
PAGE
36 2-5, 9 6-8, 13. 14 10-13 15-18 16-17 19-20 21,31 22, 32 23 23, 30 32
24,26 28 29 25, 27 25.30
33. 34
33
35
37-40 41,43 42, 44
45
45
48
packaged boilers
GAS FIRED WATER
ry< AMERICAN LSJ STANDARD
HYDRONIC HEATING
GPM(X) PACKAGED GAS BOILERS
Completely Smcm.Mo!. ,uv->wr<! ami jai kn.t;u. RegOTarlv supplied for 115 volt (ill cycle powei supply with 2-1 volt sv.-tem 01
self energizing controls at no extra charge. (Specify controls desired I
Built-in purge valve. Built-in air separator I patented "Elimmatre"). Intermittent circulator opeiation. Design certified by A.C..A. foi combustible floor and closet installations. Cast iron drilled port burnets are standard equipment for natural gas. Ribbon burners ate standard for piopane gas--optional for natural gas at
1(1',; reduction of rating as indicated by model number suffix R. Tested and equipped for 3d lbs. water woi king pressure. Ratings shown are foi installation at sea level ami up to 2.(did feet.
WATER -- for natural gas -- 100% shut-off
packaged botlar number
GPM(X)-3 GPM(X>-4 GPM(X)-5 GPM(X)-6 GPM(X)-7 GPM(X)-8
AG. A. | A G.A
input
1 output
Mbh ; Mbh
66 1 52 8 99 79 2 132 105 6 165 132 0 198 158 4
231 184 8
nat l = B = ft
rating Mbh
46 1 68 7 92.2 114 8 137 4 160 9
WATER -- for propane gai -- 1 OO % shut-off
GPM(X)-3R GPM(X)-4R
GPM(X)-5R GPM(X)-6R GPM(X)-7R
GPM(X)-8R
60 1 90 ! 120 1 150 i 160 210 ;
48 72 96 120 1 44
168
41.7
62 6 83 5 104 3 125 2 146 1
j | 1
nat rating *q. ft. water
307 458 615 765 916 1073
278 417 557 695 835 974
! T Trad r Prtcet
i with ttanderd equipment
j GPM(X)
GPM
1 with
lata
1 *ionion lank
xpantion tank
1 $418.00
1 457.00 , 521.00 | 595.00
668.00 740.00
$386.00
427.00 493.00 567.00 640.00
713.00
1 418.00
| 457.00 j 521.00 ! 595.00 { 668.00 ! 740.00
386.00 427.00 493.00 567.00 640.00 713.00
aDproi hipping wignt
201 244 263 341 337 434
2C1 244 253 34 1 357 434
Ordering Eiomplet:
Packogad boiler with itondord equipment: 1 GPMX'6 boiler with 24 volt control! Not gat, 1000 fitu, .6 ig.
?. Packaged boiler with optional equipment; 1 GPMX-7R boiler with 24 volt control! for conjtont circulator operation. Not. goi. 1000 Btu, .6 ig. 1 converiion kit fr6m natural to propane go!.
3. Pockaged boiler with jlondard equipment. 1 GPMX-4R boiler with 24 volt control! Propone go!. 2500 Btu, 1.53 !g.
Standard Equipment
VS00 series manifold gas valve Draft Hood
Expansion Tank
1U" Circulator with Piping
Wiring- Harness
Auto Air Vent
ASME relief valve, 30 lb.
Automatic Fill Valve Diain valve
Specify 24 Volt . . . or . . . Specify Seif Energizing
TS22D theimostat L408i'D limit control R822*'*R transformer (40\*Ai
and circulator relay
T822D thermostat LS14SG limit anti cncuiato; ie!ay i-jnVA i
Optional Equipment
Constant cncu'ation (24 V) L4081B limit and reverse acting circulate controls with AT20D transformer. Furnished at no additional charge.
Constant circulation (S.E.) L4f8lB limit and >everse acting circulatoi control and TS822A thermostat. Furnished at no additional chaige
Conversion Kits: Boileis must he specified with suffix letter R. Reduced propane ratings apply.
Natuial to Piopane gas.................................................. Trade Price $8.80 Pi opane to Natural gas................................................... T Trade Price $8 *
Zone vahe packages aie available for water boilers. For details a-, prices, see page 33.
hh-75-i See page 48
For cce-D'etc
.i-v-c'.5 'e'e' *c
Page 2 Ca - 3. 1
N? ?*>$* B?
07610
AMERICAN Si STANDARD
hvdronic heating
PACKAGED BOILERS GAS FIRED WATER
G-2 PACKAGED GAS BOILERS
Completely assembled--pve-wired--controls for foiced circulation--deluxe jacket. Available with or without tankless heater for domestic hot water. Built-in air separator (patented "Elinunaire"). 30 lbs. water working pressure. Regularly furnished for 11 f> volt. 60 cycle with '24 volt control system. Listed rating for installations at sea level to 2,000 feet.
WATER--for noturol and propone gases--100% shut-off
pieki|id boiler
number
AG.A. input
Mbh
A.G.A. output
Mbh
tankless heater
number
|=W = H rating
net
l=8=R rating
Mbh
net rating
sq ft water
Packaged boilers with factory installed tankless heater
G-24-DPT
90
72 218 2 Vi
62.6
417
G 25 DPT 120
96 222 3
83 5
556
G-26DPT 150 120 222 3>/. 104 3 695
G 27-DPT 180 144 222 3 V2 125 2 834
Packaged boilers less heater
G-23-DP
G-24-DP G-25-OP G 26-DP G-27-DP
60 48 90 72
120 96 150 120 180 144
41 7
62 6
83 5 104 3 125 2
278
417
556 695 834
^Gallons of water oer mmute reaie 2 *'ZT~ 60? \z 160? w tn 270- CO >' waie'
Trade Price with standard equipment
$628.00 702.00 771.00
835.00
oe-a;
494.00
581.00
650.00 733.00 783.00
epprqx. shipping
weight
416 481 551 620
333 403 472 542 503
Ordering Examples:
1. Packaged boiler less heater with standard equipment: 1 G-24-DP boiler Nat. gas. 1000 Btu, .6 sg.
2. Packaged boiler with factory installed heater with optional equipment: 1 G-26-OPT boiler with ribbon burners and Nat. to Propane conversion kit. Na*. gas. 1000 Btu, .6 sg
3. Packaged boiler with standard equipment: 1 G-25-DP boiler with ribbon burners Propane gas, 2500 Btu. 1 53 sg.
Standard equipment
V3u0 Sei les manifold gas valve 1 ' " Circulator with piping ASME relief valve Diaft hood (for G-23 only, shipped
m sepai ate cai ton i
Presst.ie and teir.pei atu'e gauge Wii ing hai r.es.-
AT2bD trar.sfoi mei rJiV. less heater bo;lers oniy}
Additional standard equipment for boilers with heater
Tankless heater as listed above T822D (24V. > theimostat L8124E (24V.) or L8124B (S.E.) triple Aciuastat relay
Additional standard equipment for boilers less heater
T822D i 24 V. i or TS822A (S.E.) thermostat L4"3lR (24 V. and S.E i combination high !;n.it and cii cu'a'.nt conti ol
Optional equipment
Self-energizing controls with VSS2<i gas valve, available when spec.net: on order ........................................................................................................... no chai gt-
L8I48E (24\".) or L8148G (S.E.) combination limit lelay........nochaige
Natural In Piopane gas conversion kit1-. Oidei boiler "with i ibhon burners" and "N'atuial to Propane conversion kit":
G-23 thru G-27 ....................................................................... T Trade Price 57.65
Floor shield for comhustible finonng. Add suffix lettei "C" to lmde>
numlier ................................................
ad<( 54.45
Note: Manual opening fcatuie is furnished with self-er.ei gizmg cor.tio .as listed above.
Zone valve packages are available foi watei linilei.- Foi details ard prices, see page 33.
y? See page 48
co^c'ete specified!
Page 3 .`a lz
No i3* b
HH-75-1
07611
PACKAGED BOILERS GAS FIRED STEAM
^AMERICAN Lsd STANDARD
HYDRONIC HEATING
G-2 PACKAGED GAS BOILERS
Completely assembled--pre-wned--controls foi steam .application-- flush oi' deluxe jacket.
Repularly furnished for 115 volt. GO cycle with 24 volt control system Listed ratings for installations at sea level to 2.000 feet.
STEAM--for natural and propane gases--100% shut-off
packaged boiler
number
A.G.A. input Wbh
A.G.A.
output Mbh
net 1 = 8 = R rating
Mbh
sq ft
G-23SP* 60 48 36
G-24SP* 90 72 54
G-25-SP*
120
96
72
G-26-SP* 150 120
90
G-27SP* 180 144 1C8
Acd sutfiK letter "F" for flush or 0" tor seluxe jacket
150 225 300 375 450
Trade Price with standard equipment
flush Jacket
deluxe Jacket
$414.00 503.00 578.00 649.00 711.00
$436.00 524.00 600.00 669.00 733.00
approx. shipping
weight
310 376 443 518 581
Standard equipment
YSfio Series manifold gas valve No. 67-GAP. I 24V. and S.E.) low
watei cut-off Gauge glass with trim
Draft hood ifor G-23-D and G-23-F thru G-2T-F. shipped in separate carton)
T822D (24V.) or TS822A (S.E.i thermostat
PA4U4A (24V. and'S E.) pressure limit control
AT20D trar.sfoimer levcept S.E i ASME safety valve Steam gauge
Ordering Examples:
1. Packaged boiler with standard equipment: 1 G-26-SPD boiler Nat. gas, 1000 8tu, .6 sg.
2. Packaged boiler with optional equipment: 1 G-24-SPD boiler with self-energiting controls Nat. gas, 1000 Btu, .0 sg.
3 Packaged boiler with standard equipment 1 G-27-SPD boiler with ribbon burners Propane gas, 2500 Btu. 1.53 sg.
Optional equipment
Self-energizing controls (with VS820 gas valve) ..........................no charge Floor shield for combustible flooring ................................................ add $4.45 Natural to Propane gas conversion kits. Order boiler "with ribbon burners'1 and "Xatuial'to Propane conversion kit":
G-23 thru G-27 ....................................................... Trade Price $7.65
Note: Manual opening feature is furnished with self-energizing controls as listed above. For Additional Optional Equipment, See page 15 & 16. For substitution of No. 47-2 losv water cut-off and feeder combinatior specify on order and add .............................................................................. $56.00
HH-75-1 See page 48
Page 4
fo' compete SDecihca'iors re'*' to Tec'**' :a Caiaicj Bulletin Form No TtB-2 i^ev 5
07612
^AMERICAN STANDARD
HTORONIC HEATING
PACKAGED BOILERS GAS FIRED WATER
C-2 PACKAGED ALL-PURPOSE GAS SC'LERS
Completely assembled--pre-wired--for forced circulation or gravity installation--deluxe jacket.
Built-in air separator (patented "Eliminaire"). 30 lbs. water working pressure. Regularly furnished for 115 volt, 60 cycle, with 24 volt control system. Listed ratings for installations at sea level to 2,000 feet.
WATER--for natural and propane gases--100% shut-off
packsgad bolter
number
A.G-A. input Mbh
A.G.A.
output Mbh
net IsBsR
rating
Mbh
net rating sq ft watar
G-23-DPG
60
48
41 7
278
G-24DPG
90
72
62 6
417
G-25DFG
120
96
83 5
556
G-26-DPG
150
120
104 3
695
G-27-DPG
180
144
125 2
834
Trade Price with
standard equipment less thermostat
S362.00
451.00
530.00
603.00
666.00
approx. shipping weight
307 373 438 511 574
Standard equipment
V800 Series manifold gas valve L4080B (24V. and S.E.) immersion
limit control ASME relief valve
Pressure and temperature gauge AT20D transformer (except S.E. I Draft hood (for G-23-DPG only
shipped in sepai ate carton i
Ordering Examples:
1 Packaged all-purpose boiler with standard equipment: 1 G-25-DPG boiler Nat. gas, 1000 8tu. .6 sg.
2. Packaged all-purpose boiler with optional equipment: 1 G-26-DPG boiler with self-energizing controls Nat. gas, 1040 Btu. .65 sg.
3. Packaged all-purpose boiler with standard equipment: 1 G-24-DPG with ribbon burners Propane gas, 2500 Btu. 1.53 sg.
Optional equipment
Self-energizing controls (with VS820 Series gas valve) available when specified on order ....................................................................................... no charge
Natural to Propane gas conversion kits. Order boiler with "ribbon burners'' and "Natural to Propane conversion kit" Trade Pi ire ST-65
Note: Manual opening feature is furnished with self-enei gizing conti nls as listed above.
Thermostats for 24V. and S E. control systems are available. For model and prices, see page 34.
Zone valve packages for water boilers. For details and prices, see p3ge 33. Floor shield for combustible flooring ............................. Trade Price $4.45
See page 48
Page 5
For ccrhc'eie sBeci*'C3tions refer :o Tecr'nica1 Cara
BL.'ke 1.r. Form No 710-2 tPev 5 74)
HH-75-1
07613
NON-PACKAGED BOIIERS
GAS FIRED WATER AND STEAM
^AMERICAN iSiSTANDARD
HYDRONIC HEATING
ill
H*
G-2 NON-PACKAGED ALL-PURPOSE GAS BOILERS
Section? assembled--for Water with or without tsnH heater- for domestic hot water. Steam without tankless coil.
Flush" or'Jeluxe jacket. 30 lbs. water, 15 lbs. steam working pressure. Regularly furnished for 115 volt, GO cycle, with 24 volts control system. Listed ratings for installation at sea level to 2,000 feet.
WATER--Natural and Propane Gases--100% shut-off. (Available with factory installed Tankless heater, see options, page 16)
boiler number
AGA.
input Mbh
A G A. Mbh
net l=-8 = R
rating
Mbh
net rating
q ft water
^ Trade Price with standard eouipmant
lets thermostat
flush Jacket
deluxe Jacket
G-23--W G-24-*W(T) G-25-'W(T)
G-26-* W(T) G-27-`W(T) G-28-*W(T)
G-29-*W(T) G-210-*W(T) G-211-*W(Tj
60 90 120
150 180 210
240 270 30O
48 41 7 278 6327.00 $349.00
72
62 6
417
414.00
436.00
96 83 5 556 494.00 516.00
120 104.3 144 125 2
168 146 1
695 834
974
567.00 $28.00 701.00
589.00 650.00 723.00
192
167 0
1113
216 187 8 1252
240 208 7 1391
772.00 835.00 906.00
794.00
857.00 928.00
'Substitute <et;er ' F tor tijsn or 1 O ' de'une jacket SuM'k "T" denotes ic'ced c rcutalicn DOtler eautoced *ttn factory i.-ts'aiied tanmess Vate- tsee sage tS for added cra'ge I
295 353 426
500 566 630
699 790 863
STEAM--Natural and Propane Gases--100% shut-off.
G-23'S G-24-*S G-25-*S
60 48 36 90 72 54
120 96 72
G 26 *S G-27--S
G-28-*S
150 120
90
180 144 108
210 168 126
G-29-*S
240 192 144
G-210-*S 270 216 162
G-211-*S 300 240 180
150 225 300
375 450 525
600 675 750
'Substitute tetter "F" for flush or "D" for deluxe jacket.
$385.00 472.00 552.00
625.00 686.00 759.00
831.00 893.00 965.00
$407.00 494.00 574.00
647.00 708.00 781.00
853.00 915.00 987.00
310 368 442
517 583 648
718 809 883
Ordering tramples.
1. Non-packaged all-purpose water boiler with standard equipment and flush jacket1 G-27-FW boiler Nat gas. 1000 Btu. 6 sg.
2 Non-packaged all-purpose water boiler with optional equipment and deluxe jacket. 1 G-210-DWT boiler with (11 No. 232 tankless heater installed Nat gas, 1000 Btu, 6 sg
3 Non-packaged all-purpose steam boiler with standard eouipment and flush jacket1 G-25-FS boiler with ribbon burners Propane gas, 2500 Btu. 1 53 sg
Standard equipment
YSOh Senes manifold gas valve AT20D Transformer (except S.E.) Drain valve
Draft hood (for G-23D and all flush jacketed boilers, shipped in separate carton)
Additional standard equipment
Water boilers
ASME relief valve Pressure and temperature gauge L4080 (24V. and S.E.) Aquastat
limit control
Steam boilers
ASME safety valve Steam gauge PA404A (24 V. and S.E. I piessure
limit control No. G7-GAR (24V. and S.E.) low
water cut-off Gauge glass with trimmings
Optional equipment
Side outlet ASME steam safety valve available--no charge if specified Natural to Propane gas conversion kits. Order boiler "with ribbon burners" and "Natural to Propane conversion kit":
G-23 thru G-27 ................................................................... Trade Price $ 7.65 G-28 thru G-211 ................................................................. Trade Price $10.30 Floor shield for combustible flooring ...................................Trade Price $ 4.45 Additional optional equipment--see pages 15. 16 & 18. Thermostats--see page 34.
Note: Zone valve packages for water boilers. For details and prices, see page 33.
hh-75-1 See Page 48
Page 6 For c0,r,Diele soecilicanons fete- lo Teo-mca' Ca-alcp Buiielin Form No 718-2 (Rev S 7*1
07614
^AMERICAN SiSTANDARD
HYDRONIC HEATING
NON-PACKAGED BOILERS GAS FIRED WATER
G-40 GAS BOILERS--WATER
Deluxe jacket with built-in draft hood. Regularly furnished for 115 volt. GO cycle powei supply with 21 volt rontiol system
(self energizing optional). jii lbs. water uoikmg pressuie. Listed ratings for installation at sea level to 2.000 feet.
WATER--For Natural and Propane Gates--100% Shut-Off. For Built-In Water Heaters, see page 16.
boiler number
G-403-W G-404-W G-405-W
G-406-W G-407-W G-408-W
G-409-W G-4010-W G-4011-W
G-4012-W G-4013-W G-4014-W
A.<3. A. input Mbh
150 225 300
375 450 525
600 675 750
825 900 975
A.G.A. output
Mbh
120 180 240
300 360 420
480 540 600
660 720 780
net !=B=R
rating Mbh
104.3 156 5 208.7
260.9 313 0 365.8
417 4 469.6 521.8
574 0 626.2 678 4
net feting tq. ft. water
695 1043 1391
1739 2086 2434
27B2 3130 3479
3327 4175 4523
yp Trade Price | with
j standard tquipmtnl
( leaa thermostat
$ 543.00 691.00
i 837.00
992.00 1 1147.00
1265.00
1412.00 1559.00 1707.00
1859 00 2006.00 2153.00
approx. shipping
weight
744 921 1117
1297 1475 1647
1820 1994 2195
2364 2533 2702
chimney sue
inside diam. in.
height feet
8 15 8 15 8 15
10 15 10 15 10 15
10 15 12 15 12 15
12 15 12 15 15 15
NOTE: Available as factory assembled section; in all sizes ............................................................. Trade Price per section $11.00
Standard equipment
V800A Combination Gas Valve: G-403 and G-4G4 for Nattnai Gas V800B Combination Gas Valve: G-403 thru G-407 for Propane Gas G-50AAG Combination Gas Valve: G-4o,". and G-loC for Natural Gas V88A or B-50 Diaphragm Gas Valve: G-407 thru G-4<il4 fm Natuia! Gas
C.-40S th: u G-401J fm r> -ojor.e Ga-
Gas pressure regulatoi (except pinpane pas)
Manual main gas shut-off valve -- AT20D Transfoi mer (except S.E ) Manual pilot gras shut-off valve where diaphragm gas valve is standard
L62GB (24V.) o: CS591A (S.E.) combination pilot switch ami valve with auxiliary pilot valve; (100G shut-off)
Drain valve -- Water heater opening cover plates ASME relief valve Pressuie and temperature gauge
L400GA (24V and S.E.) immersion limit control
Zone valve packages are avarlahle tot water boileis. For details ar.d prices, see page 33. Thermostats--see page 34
Ordering Example:
Water boiler with standard equipment: J G--36-W boiler Nat gas 1000 Btu. 6 sg
Other optional equipment (See page; 15. 16 and 18)
See page 48
Page 7
For cc^pfete specifications refer to Technical Cats<c<; Bwiieim Form No 7?8*? (Rev 2 2 7t l
HH-75*^
07615
NON-PACKAGED BOILERS GAS FIRED STEAM
^AMERICAN ei STANDARD
HYDRONIC HEATING
G-40 GAS BOILERS--STEAM
Deluxe jacket with buil^in draft hood. Regularly furnished for 115 volt, 60 cycle power supply with 24 volt control system
(self energizing optional). 15 lbs. steam working pressure. Listed ratings for installation at sea level to 2,000 feet.
STEAM--For Natural and Propane Gases--100% Shut-Off. For Built-In Water Heaters, see page 16.
boiler number
A.G.A.
1 Input
| Mbh
A.G.A. output
Mbh
----------------------------1
not l = B = R rating
Trade Price
with
Mbh
q. ft.
standard equipment lets thermostat
pproi. hipping
weight
chimney site
intide diem In.
height teal
G-403-S G-404-S G-40S-S
G-406-S G-407-S G-408-S
G-409-S G-4010-S G-4011-S
G-4012-S G-4013-S G-4014-S
1 150 - 225 ! 300
' 375 450
525
600 675 750
1 825 i 900
975
120 180 240
300 360 420
480 540 600
660 720 780
90.0 135.0 180.0
225.1 270.1 315.1
360.1 405 i 450.0
495.2 540 0 585.1
375 563 750
938 1125 1313
1500 1688 1875
2063 2250 2438
$ 603.00 750.00 897.00
1052.00 1207.00 1324.00
1472.00 1618.00 1767.00
1918.00 2066.00 2212.00
744 921 1117
1297 1475 1647
1820 1994 2219
2388 2557 2726
8 15 8 15 8 15
10 15 10 15 10 15
10 15 12 15 12 15
12 15 12 15 15 15
NOTE: Available as factory assembled sections in aii sizes ............................................................. Trade Price per section *11.00
Ordering Example-
Steam boiler with optional equipment. 1 G-409-ST I No 226 tankless heater with controls Nat gas. 1000 Btu, .6 sg.
Standard equipment
V800A Combination Gas Valve: G-403 and G-404 for Natural Gas V800B Combination Gas Valve: G-403 thru G-40T for Propane Gas G-50AAG Combination Gas Valve: G-405 and G-406 foi Natuia! Gas V88A or B-S0 Diaphragm Gas Valve: G-407 thru G-4014 for Natural Gas
G-408 thru G-4014 for Piopane Gas Gas pressure regulator (except propane gas) Manual main gas shut-off valve -- AT20D Transformer (except S.E.) Manual pilot gas shut-off valve where diaphragm gas valve is standard. L62GB (24V.) or CS5S1A (S.E.) combination pilot switch and valve
with auxiliary pilot valves (lfiOIF shut-off) Drain valve -- Water heater opening cover plates ASME safety valve Steam gauge PA404A (24V. and S.E.) pressure limit control Gauge glass with trim No. 67-GAR (24V. and S.E.) low water cut-off Side outlet ASME steam safety valve available. No charge if spec ihed Thermostats--see page 34.
Other optional equipment (See pages 15, 16 and 18)
HH-75-1 See page 48
Pages For comoreie spec.licanons refer lo Tecrm.cal Catalog Bu'ieim Form No 72S-2 (Pev 2 2 71)
07616
AMERICAN SJ STANDARD
HYDRONIC HEATING
PACKAGED BOILERS
GA* fired
WATER ONLY
GWP PACKAGED GAS BOILER
(Single Boiler Installation)
Completely assembled--pre-wired--forced circulation only--jacketed. Relief valve, temperature pressure gauge--draft hood included but shipped separately. 50 lbs. working pressure. Built-in air separator (patented "Eliminaire"). Regularly furnished for 115 volt, 60 cycle with 24 volt control system. Listed ratings for installations at sea level to 2,000 feet.
WATER--100o shut-off--Natural and Propane Gas
packaged boiler
"umber* GWP-S GWP-6 GWP-7
AGA input Mbh 264 330 396
AGA output Mbh 211 2 264 0 316 8
not Iss8-t
Mbh 183 5 229 6 275 7
chimney me
intide d<a m
height feet
7 15
8 15
8 15
approx thippmg weight
613 716 823
Trode Price with
itandord e gut pm on ion fh#rmoot $580.00 701 00 835.00
Standard equipment
Combination automatic gas valve Gas pressure regulator
except propanej Manual main gas shut-off valve
Manual pilot gas shut-off valve AT-20D transformer (except S.E.i Pilot Valve & Switch Dram Valve ASME Relief Valve
Pressure-Temperature Gauge
Deluxe Jacket
L4080D Immersion Limit Control
Draft Hood
Drilled Port Burners are standard for natural gas.
Ribbon Burners are standani for propane gas and optional for nat ural gas.
Optional equipment
Self Energizing controls
No charge
Zone Valve Packages are available (for details and prices see page 33.)
Add suffix "R" to model number if ribbon burners are desired.
Example: GWP-5R
Optional constant circulation (24 volt) L4081B limit and reverse acting circulator controls ....................................................... Add Trade Price $13.85
Electronic Control Panel Systems, see page 18 for prices. For applica tion and details, contact American Standard.
Sections tested for 100 psi working pressure Trade Price add per section $11.00
Thermostats--see page 34
See page'48
Page 9
Pot comoleie soeciticahons reier to Tecf^icat Catalog Buiieiin Porm No. 70205-2 (Rev. 12 70,
HH-75-1
07617
NON-PACKAGED MODULAR
GAS fired WATER ONLY
rsi AMERICAN kd STANDARD
hydronic heating
GWM GAS MODULAR BOILER HOOK-UP
(Modular Boiler Installations)
The-GWM Modular Boiler Hook-up is a combination or multiple of five, six or seven section GWM boiler modules. Factory assembled sections with burners, pas manifold, and automatic pas valve mounted. Deluxe jacket, controls and draft hood are shipped separately. The patented "Ehminaire" is standard. Furnished for 115 volt. fiO cycle power supply with 24 volt control system. (Selfenergizing controls are not available). Tested and equipped for 50 PSIG workinp pressure. Indicated ratings are for installation at sea level to 2.000 ft. elevation.
__ /ig'Qj
\Sv'*y nrr
GWM BOILER MODULES - Natural and Propane Gas: 100% Shut-Off.
/**dwl* b'lf r Number* GWM-5
AGA npwl Mbh 264
AGA Du'Pwl Mbh 211.2
A*> l=l = R
Mbh
183.5
GWM-6
330
264 0
229.6
GWM-7
396
316 S
275.7
Opproi. ih<ppng wtightt
Ibi 629 735 846
Trod* Rric* ,ih
ttonderd (qvipnruf lf)t hermOf S563.0Q
684.00 818 00
Standard equipment
Combination automatic Gas Valve
Gas pressure regulator (except propane)
Manual Main Gas shut-off valve Manual pilot pas shut-off valve Transformer Relay R8227B Pilot valve and switch Drain Valve ASME Relief Valve(s) as required
Pressure-Temperature Gaupe as required
Deluxe Jacket L4080D Immersion Limit Cortio!
Draft Hood
Drilled Port Burners standard for natural pas.
Ribbon burners standard for propane pas and optional foi natural pas.
Optional equipment
1. Factory fabricated Water Manifold for Primary/Secondary circulation. Includes interconnecting supply piping (Boiler to manifold). Inieiconnecting return piping and circulator not included. . . Trade Price add per module S55.00
2. Factory fabricated Water Manifold for Parallel Boiler Hook-up In cludes interconnecting supply and return piping (boiler to manifold i Trade Price add per moduleSII1.00
3. Electronic Control Panel Systems, see page 18. For application and details, contact American Standard.
4. Sections tested for 100 psi working pressure. .................................................................... Trade Price add per section $11.00
Thermostats--see page 34.
Add suffix "R" to module boiler number if ribbon burners are desired Example -- GWM-5R
hh-75-1 See page 48
Pape 10
For co-D-ie'e speci'ica::on$ refer to Tec^'ca! Cai&'os
Fo'rr> so 70269-2 <ev 12 7Q)
07618
^AMERICAN laSTANDARD
HYDRONIC HEATING
NON-PACKAGED MODULAR GAS FIRED
WATER ONLY
GWM GAS MODULAR BOILER HOOK-UP
(Modular Boiler Installations)
The following: holier units in fm.OOO BTU input increment?* are achieved with module boiler combination*:
MODULAR BOILER HOOK-UPS -- Natural and Propane Gas - 100% Shut-Off.
gflit
GWM-528 GWM-594 GWM-660 GWM-726 GWM-792 GWM-858 GWM-924 GWM-990 GWM-10S6 GWM-1122 GWM-1188 GWM-1254 GWM-1320 GWM-1386 GWM-1452 GWM-1S1B GWM-1584 G WM-1650 GWM-1716 GWM-1782 GWM-1848 GWM-1914 GWM-1980 GWM-2046 GWM-2112 GWM-2178 GWM-2244 GWM-2310 GWM-2376 GWM-2442 GWM-2508 GWM-2574 G WM-2640 GWM-2706 GWM-2772 GWM-2830 GWM-2904 GWM-2970 GWM-3036 GWM-3102
GWM-316B and upward
See page 48
modular competition
5 IH1
2 1
_
-- 2
--
_ _
__
--
-
_ --
-
_ --
_ --
_ --
-- --
~
_ --
-
__ --
-
--
4 11(1
_
1 2
--
2 3 2
1 _ 3
4 3 2
1
_
5
4 3 2
1
--
5
4 3 2
1
--
5
4 3 2
1
--
5
4 3
2
1
7 *ct.
_
_
2
_
--
2 3
1 2
3 4 -
i 2 3
4 5
2 3 4
5 6 2
3 4 5
6 7 3
4 5
6 7 8
grots input Mbh
528 594 660
726 792 858
924 990 1056
1122 1188 1254
1320 i3e6 1452
1518 1534 1650
1716 1782 1843
1914 1980 2046
2112 2178 2244
2310 2376 2442
2508 2574 2640
2706 2772 2838
2904 2970 3036
3102 3168
grass output Mbh
422 4 475 2 528 0
580.8 633 6 686 4
739 2 792 0 844 8
897.6 950 4 1003 2
1056 0 1106 8 1161 6
1214 4 1267 2 1320 0
1372 8 1 425 6 1476 4
1531.2 1584 0 1636 0
1639 6 1742 4 1795 2
1848 0 1900.6 1953 6
2006 4 2059.2 2112 0
2164 8 2217.6 2270 4
2323 2 2376 0 2428 8
2461.6 2534.4
not output Mbh
367,0 413 9 459 1
504 3 551 3 596 5
643 5 688 7 733 9
780 9 626 1 873 0
918 3 963 5 1010 4
1055 7 1102 6 1147 8
1193 0 1240 0 1 285 2
1332 2 1375 4 1422 6
1467 0 1516 5 1561 7
1607.0 1652 2 1697.4
1746 1 1791 3 1836 5
1861 7 1927 0 1975.7
2020 9 2066 1 2111.3
2156.5 2205 2
opproi (hipping woight
1258 1364 1470
1581 1692 1993
2099 2205 2316
2427 2538 2S34
2940 3051 3162
3273 3384 3675
3786 3897 4008
4119 4230 4521
4632 4743 4854
4955 5076 5367
5478 5589 5700
5811 5922 6213
6324 6435 6546
6657 6768
Modular Operating Control Package Options
1. Four stage immersion type operating eontrul. (one required for up to
4 modules)
Trade price add per control $95.00
2. Immersion type operating controls with individual outdoor resets. Trade price add per module $64.00
3. Eight stage boiler sequencing control panel system with outdoor- reset, (one required for up to 8 modules) Trade price add per control $363.00
4. Sections tested for 100 ppj working pressure. .....................................................................Trade Price add per section $11.00
Page 11
Scr coT.^iete specifications fete' t: Technical Caia'OQ Bulletin Fom No 7C28S'-2 'Re* i? "7C
Trade with ttandord equipment
lets thermostat
S1107.00 122B.OO 1349.00 1483.00 1617.00 1771.00 1892.00 2013.00 2147.00 2281.00 2416.00 2556.00 2677.00 2812.00 2946.00
3080.00 3214.00 3342.00 3496.00 3630.00 3764 00 339e.OO 4033.00 4160.00
4294.00 4429.00 4563.00 4697.00 4831.00 4959.00 5093.00 5227.00 5361.00
5496.00 5630.00 5757.00 5692.00 6026.00 6160.00
6294.00 6428.00
HH-75-
07619
NON-PACKAGED SINGLE OR MODULAR--GAS FIRED WATER ONLY
^AMERICAN csiSTANDARD
HYORONIC HEATING
GW NON-PACKAGED GAS WATER
(Single or Modular Boiler Installation!)
The GW non-packaged boiler designed for forced circulation only. Factory assembled scrt:cr.r. Jackets, burners and manifolds shipped separately. Ir-cl-de.-. idicf \aive, tem perature-pressure gauge, and draft hood. The patented "Elinunaire" is standard.
Boiler tested and equipped for 50 PSIG working pressure. Furnished for 115 volt, 60 cycle power supply with 24 volt controls. Self-energizing controls available at no addi tional cost.
Ratings shown are for installations at sea level to 2000 ft. elevation.
INDIVIDUAL BOILERS -- WATER -- 100% shut-off -- Natural and Propane Ga*
chimney tixt
bailer Avtnbtf*
A G A. input Mb*
A.G A. output MbH
net 1=8=1
Mbh
Intide dip. in.
height feel
GW-8 G W-9 GW-10
462
528 594
369 4 422.4
475.2
321.7 367.0 413.9
9 10
10
15 15
15
opprei. shipping raighl
938 1052 1177
Trade Price with
ttondord equipment less thermostat
$ 903.00 977.00
1051.00
MODULAR BOILERS - WATER - 100% ihut-off - Natural and Propane Gas
unit number
GW-924 GW-990 GW-10S6 GW-1122
GW-1188 GW-1386 GW-1452 GW-1518
GW-1584 GW-1650 GW-1716 GW-17B2
GW-1848 GW-1914 GW-1980 GW-2046
modular tempo*! ion
....
2 1
--
| * sect | 10 ted.
!_
_
1-- 2; -- 11
-- ;-- 3--
21 12
2 --
_
--
--i 3: --
--; 2i 1
--! 1
2
--3
4 '--
--
3! 1!--
2 2--
ii3
--
groit input Mb*
924 990 1056 1122
1188 1386 1452 1518
1584 1650 1716 1782
1848 1914 1980 2046
grott output
Mbh
739 792 845 898
950 1108 1162 1214
1267 1320 1373 1426
1478 1531 1584 1637
net output
Mbh
644 689 734 781
826 964 1010 1056
1103 1148 1193 1240
1285 1332 1376 1423
appres. chipping
woighlt
Trode Price with s'ondo'd equipment
leu thermostat
1876 1990 2104
2229
$1806.00 1880.00
1954.00 2027.00
2354 2814
2928 3042
2101.00 2709.00 2783.00
2857.00
3156
32B1 3406 3531
i 1
, |
2930.00 3004.00 3078.00 3152.00
3752 j 1 3866
3980 4094 |
3612.00 3686.00 3760.00 3B34.00
Standard equipment
Combination automatic gas valve
Pressure-Temperature Gauge
Gas pressure regulator (except propane)
Manual gas shut-off valve Manual pilot gas shut-off valve AT-20D Transformer (except SE) Pilot Valve and Switch Drain Valve
L-4080D Immersion Limit Control
Deluxe Jacket
Draft Hood
Drilled Port Burners standaid for natural gas.
Ribbon Burners standard for propane gas and optional for
ASME Relief Valve
natural gas.
Optional equipment
Sections tested for 100 psi working pressure.
........................................................................... Trade Price add per sectior.S11.00
Self-energizing controls...................
no charge
Thermostats--see page 34.
Electronic Control Panel System, see page 18. For application and de tails, contact American Standard.
Modular Operating Control Package Options
1. Four stage immersion type operating control (one required for up to 4 modules) ........................................... Trade Price add per control $95.00
2. Immersion type operating controls with individual outdoor resets (one
required for each module).
Trade Price add per module S64.00
3. Eight stage boiler sequencing control package with outdoor reset (one required for up to 8 modules) . Trade Price add per control $363.00
Add suffix "R" to model number if ribbon burners are desired. Example: GW'-8-R
HH-75-1 See page 48
Page 12
for complete speciiicaiions re'ef lo Tecnnicai Caia'pg Bu"e'<n Pcfm No 70289-2 iRtv 12 70)
07620
PS! AMERICAN iSiSTANDARD
HYDRONIC HIATI NO
NON-PACKAGED
gas piped
WATER
G-10 GAS BOILERS --
AGA approved inputs 800 MBH to 6400 MBH. Single combustion chamber--jacketed.
Available with built-in heaters for storage tank or tankless application. 50 lbs. water
working pressure. Integral draft hood rear outlet--optional top outlet--natural gas
only (except G-1010) available at no extra charge. Regularly furnished for 115 volt,
60 cycle power svstem with 9s vn!t controls. Listed ratings for installation ol sea ievei
to 2,000 feet.
__
WATER -- Natural Gat -- 100% Shut-Off. Por Built-In Water Heaters, tee page 17.
belief number
A.OJL input
Mbh
A.QJL output
Mbh
enotlwBwft piping and
rating Mbh
pick-up
factor A
^Trade Price
net rating with standard
sq. ft weler
leea
thermostat
approx. hipping weight
chimney else
Inside diem. In.
ht ft
G-105-W G-106-W G-107-W
G-10B-W G-109-W G-1010-W
G-1011-W G-1012-W G-1013-W
G-1014-W G-1015-W G-1016-W
G-1017-W G-1018-W G-1019-W
G-1020-W G-1021-W G-1022-W
G-1023-W G-1024-W G-1025-W
G-1026-W G-1027-W G-1028-W
G-1029-W G-1030-W G-1031-W
G-1032-W G-1033-W
800 1000 1200
1400 1600 1800
2000 2200 2400
2600 2800 3000
3200 3400 3600
3800 4000 4200
4400 4600 4800
5000 5200 5400
5600 5800 6000
6200 6400
640 800 960
1120 1280 1440
1600 1760 1920
2080 2240 2400
2560 2720 2880
3040 3200 3360
3520 3680 3840
4000 4160 4320
4480 4640 4800
4960 5120
556.5 695.7 834.8
973.9 1113.0 1252.2
1391.3 1530.4 1669.6
1808.7 1947.8 2087.0
2226.1 2365.2 2504.3
2643.5 2782.6 2921.7
3060.9 3200.0 3339.1
3478.3 3617.4 3756.5
3895.7 4034.8 4173.9
4313.0 4452.2
1.15 1.15 1.15
1.15 1.15 1.15
1.15 1.15 1.15
1.15 1.15 1.15
1.15 1.15 1.15
1.15 1.15 1.15
1.15 1.15 1.15
1.15 1.15 1.15
1.15 1.15 1.15
1.15 1.15
3710 4638 5565
6493 7420 8348
9275 10203 11131
12058 12985 13913
14841 15768 16695
17623 18551 19478
20406 21333 22261
23189 24116 25043
25971 26899 27826
28753 29080
$ 1697.00 2067.00 2433.00
2824.00 3156.00 3493.00
3846.00 4293.00 4824.00
5212.00 5539.00 5880.00
6236.00 6611.00 7002.00
7327.00 7717.00 8058.00
8446.00 6803.00 9131.00
9521.00 9893.00 10160.00
10421.00 10826.00 11154.00
11480.00 11822.00
2706 3153 3627
4107 4584 5077
5568 6146 6659
7179 7752 8248
8744 9253 9765
10301 10778 11341
11851 12360 12891
13384 13876 14374
14878 15368 15891
16406 16936
14 14 14
16 16 18
18 20 20
22 22 22
22 24 24
24 26 26
26 26 28
28 28 28
30 30 30
30 30
20 20 20
20 20 20
20 20 20
20 20 30
30 30 30
30 30 30
30 30 30
30 30 30
30 30 30
30 30
* The net l=B = R rating* shown are baaed on tha factors shown in the pipmf and ptckup column. American-Standard should be consulted before selecting a boiler for installations having unusual piping and pickup requirements.
Standard equipment
V88A or B50D gas valve(s) Gas pressure regulator (except
Propane gas) Manual main gas shut-off valve Manual pilot gas shut-off valve
AT20D Transformer Ribbon type main burners ASME relief valve
Drain valve Draft hood L62GB combination pilotstat and
H17BA1 pilot valves
Pressure and temperature gauge L4006A immersion limit control Thermostats--see page 34.
Optional equipment 80 lbs. water test--Trade Price per
section............................................... $11.00 Factory assembled sections thru
G-1011 Trade Price per section $30.00
Other optional equipment:
See pages 15. 17 and 18
Ordering Examples:
1. Water bailer. 1 61013 W bailer Net. p*. 1000 Btu, .6 if.
G-10 GAS BOILERS -- WATER for Propane Gas
Propane Gas Ratings are determined by reducing the Natural ratings above by 10%. Example: G-105-W A.G.A. input 800 less 10%=720 Mbh Input for Propane Gas. Detailed Propane Gas ratings are shown in current Technical Literature. Trade Prices, Chimney Sizes and shipping weights remain the same as shown above.
See page 48
Page 13
For complt pecilictlion* r#fr to Technical Catalog BuMeim Form No. $$8-2 (Rev. 12/72)
HH-75-1
07621
NON-PACKAGED GAS FIRED STEAM
,_|AMERICAN kSiSTANDARD
HYDRONIC HEATING
G-10 GAS BOILERS
AGA approved inputs 800 MBH to 6400 MBH. Single combustion chamber--jacketed. Available with built-in heaters for storage tank or tankless application. 15 lbs. steam working pressure. Integral draft hood rear outlet--optional top outlet ratural gas only (except G-1010) available at no extra charge. Regularly furnished for 115 volt, 60 cycle power system with 24 volt controls. Listed lacings for installations at sea level to 2'000 feet. Factory-sections assembled thru G-1011 optional add Trade Price $23.00 per section.
STEAM -- For Natural Gas -- 100% Shut-Off. For Built-In Water Heaters (G-105S thru G-I014S only) See pageT 7
boiler number
A.G.A. Input
Mbh
A.G.A. output
Mbh
a net 1 = B s ft rating
Mbh
sq. ft.
l=B=R piping and
pick-up factor a
Trada Rrlca with standard equipment lees
thermostat
approx. shipping weight
chimney size
inside dlam. in.
ht. ft.
G-105-S G-106-S G-107-S
G-108-S G-109-S G-1010-S
G-1011-S G-1012-S G-1013-S
G-1014-S G-1015-S G-1016-S
G-1017-S G-1018-S G-1019-S
G-1020-S G-1021-S G-1022-S
G-1023-S G-1024-S G-102S-S
G-1026-S G-1027-S G-1028-S
G-1029-S G-1030-S G-1031-S
G-1032-S G-1033-S
800 1000 1200
1400 1600 1800
2000 2200 2400
2600 2800 3000
3200 3400 3600
3800 4000 4200
4400 4600 4800
5000 5200 5400
5600 5800 6000
6200 6400
640 800 960
1120 1280 1440
1600 1760 1920
2080 2240 2400
2560 2720 2880
3040 3200 3360
3520 3680 3840
4000 4160 4320
4480 4640 4800
4960 5120
480.1 600.1 720 2
840.2 962.4 1095.1
1227.9 1361.2 1489.5
1614.9 1739.1 1863.4
1987.6 2111.8 2236.0
2360.2 2484.5 2608.7
2732.9 2857.1 2981.4
3105.6 3229.8 3354.0
3478.3 3602.5 3726.7
3850.9 3975.2
2000 2501 3001
3501 4010 4563
5116 5672 6206
6729 7246 7764
8282 8799 9317
9834 10352 10870
11387 11905 12422
12940 13458 13975
14493 15010 15528
16046 16563
1.333 1.333 1.333
1.333 1.330 1.315
1.303 1.293 1.289
1.288 1.288 1.288
1.288 1.288 1.288
1.288 1.288 1.288
1.288 1.288 1.288
1.288 1.288 1.288
1.288 1.288 1.288
1.288 1.288
$ 1757.00 2126.00 2497.00
2688.00 3226.00 3552.00
3960.00 4422.00 4902.00
5290.00 5617.00 5958.00
6314.00 6749.00 7139.00
7466.00 7853.00 8195.00
8584.00 8942.00 9269.00
9657.00 10031.00 10295.00
10560.00 10964.00 11292.00
11617.00 11959.00
2706 3153 3627
4107 4584 5077
5568 6146 6659
7179 7752 8248
8744 9253 9765
10301 10778 11341
11851 12360 12891
13384 13876 14374
14878 15368 15891
16406 16936
14 14 14
16 16 18
18 20 20
22 22 22
22 24 24
24 26 26
26 26 28
28 28 28
30 30 30
30 30
20 20 20
20 20 20
20 20 20
20 20 30
30 30 30
30 30 30
30 30 30
30 30 30
30 30 30
30 30
A The net l = B = R ratings shown are bated on the factors shown m the piping and pickup column. American-Standard should be consulted before selecting a boiler for installations having unusual piping and pickup requirements.
Standard equipment
V88A or B50D gas valve (s) Gas pressure regulator
(except propane gas) Manual main gas shut-ofT valve Manual pilot gas shut-olT valve AT20D Transformer AbMti salety valve Steam gauge Ribbon type main burners
Optional equipment
Factory assembled sections thru G-1011 Trade Price per section $30.00
Drain valve Draft hood L62GB combination pilotstat and
H17BA1 pilot valves PA404A pressure limit control Gauge glass with trimmings No. 67AR Low Water cut-off Thermostats--see page 34. Side outlet ASME steam safety valve available. No charge if specified.
Other optional equipment:
(See pages 15, 17 and 18).
Ordering Etsmplev.
Sl*jm boiler with standard equipment 1 GI01S-S boiler Nat |av 1000 8tu. .$5 i|
G-10 GAS BOILERS -- STEAM for Propane Gas
Propane Gas Ratings are determined by reducing the Natural Gas ratings above by 10%. Example G-105-S A.G.A. Input 800 less 10%=720 Mbh Input for Propane Gas. Detailed Propane Gas ratings are shown in current G-10 Technical Literature. Trade Prices, Chimney Sizes and shipping weights remain the same as shown above.
HH-75-1 ^ See page 48
Page 14
For complete epecilicetions reler to Technical Catalog Bulletin Form No 6M-J (Rev 12/7J)
07622
4SJSTANDARD MYORONIC HEATING
miscellaneous options
GAS BOILERS
MISCELLANEOUS OPTIONS -- NON-PACKAGED GAS BOILERS
G-2, G-40 AND G-10 BOILERS:
'`IS" Equipment: boilers can be furnished for use with Indirect Steam Hot Water Supply Systems. L4006A im mersion operating control for use in storage tank is re quired and will be furnished when specified on order at extra Trade Price $16.90. This control operates gas valves on boiler electrically as required.
No. 47-2 boiler water feeder and cut-off combination is available instead of the 67-AR with G-2, G-40 and G-105 thru G-108 steam boilers at additional Trade Price .$55.65
Low water cut-offs for water boilers: No. 63 cut-off for water working pressures of 50 lbs., or less. Trade Price .... $57.50
No. 150 cut-off for water working pressures in excess of 50 lbs. available when specified. Trade Price .................... $85.90
Try-cocks and lappings: for steam boiler to meet local code specify on order. Trade Price ............................................ $5.70
G-2 BOILERS: "DW" (Direct Water) equipment: In addition to water boilei standard equipment, page 6, includes pressure gauge. 31' lb. ASME relief valve, L4006A Aquastat for storage tank, tank thermometer, name and rating plate for 80 lbs. water working pressure. Specify boiler with "DW" equipment. Trade Price .............................................................................. $22.20
Floor shield for combustible flooring: Add suffix letter "C" to boiler number. Trade Price ............................................ $4.45
G-2 AND G-40 BOILERS:
Self-energizing control: All size G-2 and G-40 for propane gas. AH G-2 and G-40 thru G-4010 for natural gas. Equip ment includes: S.E. gas valve, Q313A Thermopile Gen erator and a L4006 S.E. limit control (water boileis less heater) or an L8124B Triple Aquastat Relay (water boilers with heater) or a PA404A Pressuretrol (steam boilers less heater). For steam boilers with heater L4006A S.E. immersion operating control will be turnished in addition to the Pressuretrol. Furnished at no additional charge when specified on order. Special thermo stat required, for Trade Price, see page 34.
No. 101-24V electric water feeder can be added to the No. 67-GAR low water cut-off regularly furnished with steam boilers to provide low water cut-off and feeder combina tion at additional Trade Price ........................................ $75.00
Zone circulator control for water boiler with tankless heat er and combination immersion control-relay: use one T822D $7.70 thermostat and one R845A $22.35 relay for second and/or third zone.
Water flow regulators sized for tankless heater involved will be furnished with heater when specified on order to meet local Utility requirement. Trade Price per heater.......$4.45
G-40 AND G-10 BOILERS:
No. 51-2 boiler water feeder and cut-off available instead of No. 67-AR regularly furnished with G-109 thru G-1033 steam boilers. Trade Price ................................................. $85.00
G-40 BOILERS:
Boilers with Tankless Heaters: ware: (foi forced escala tion) and steam boilers. Heaters are limited to boiler sizes as shown in ratings table on next page. Specify heater and add suffix "T" to boiler number.
G-10 BOILERS:
Pilot filters for G-10 available at no additional charge when specified on order to meet local utility codes.
G-10 Steam Boiler external water heater tappings in cover
plates: maximum size
Specify number of cover
plates. Trade Price per tapping ........................................$S.70
G-10 Right End Section Steam Trim Tappings for pressure gauge and water column fittings or for auxiliary controls furnished as standard equipment at no additional charge.
Modulating gas valve: the G-lf) boiler can be specified with the V4062/5055B gas valve for Hi-Lo-off operation. Valve permits adjustment of the Lo-fire operation down to a minimum of 20% of the boiler input. Operation of the valve should be controlled by a SPST operating control.
Specify on order and add to the Trade Price of the boiler with regular equipment.
G-105 thru 1018 ....................................................................$218.00
G-1019 thru 1033 ..................................................................$275.00
See page 48
Page 15
HH-75-1
07623
-K id
TANKLESS HEATERS-GAS FIRED WATER AND STEAM
I AMERICAN ei STANDARD
HYDRONIC HEATINO
G-2 TANKLESS HEATERS
G-2 NON-PACKAGEO ALL PURPOSE BOILER: Fictory installed tankless heaters: When boilers (4 thru 11 section) are to be used for forced circulation. See table belc'.v for I=W=H rstir.g; ;r,d applicable boiler size. Specify heater, add suffijH'T" to boiler number and "factory installed." Add Trade Price shown.
Ratings
number
A.C.A. Input tWhr.
he2a11ter
IbWh Aatlftf
he2a2t2er
M2a24tir
N2e3a2ter
G-24 G-25
90.000 120.000
2V, --
--
3
-- --
-- --
G-26 GG-2278 GG--22910 G-211
150.000 180.000 210.000 240,000 270.000 300.000
-- -- -- -- --
--
33V`4. 3 Vi 33 lV/?i 3 Vi
--
4 4'/, 4*v.
'/.
4 Vi
-- --
--
4 Vi 4(4 5
G-2 PACKAGED AND NON-PACKAGED ALL-PURPOSE BOILERS:
Tankless heaters: When boilers (4 thru 11 section) are to be used for forced circulation I=W = H tankless heaters can be installed in opening used for gravity tapping flange cover. See table for I=W = H ratings and applicable boiler size. Tankless heaters can be ordered shipped separately at the "sold separate" Trade Prices shown below.
heater numbtr
218 222 226 232
Trade Prices
factory installed
$55.00 61.00 75.00 87.00
sold separata
S32.00 39.00 53.00 65.00
L8124E for 24 Volt or L8124B for SE, Triple Aquastat Relay furnished with heater (packed in trim box).
Water tlow regulator. Specify on order. Trade Price ... $4.45
G-40 TANKLESS HEATERS -- STEAM OR FORCED WATER BOILERS
Ratings (Gallons per minute*) Trade Prices
HEATEH NO.
HEATER WITH CONTROLS
Water
StaaaC)
HEATER ONLY Water ar SNmi
218
855.00
848.00
832.00
222
1.00
55.00
38 00
226
75.00
0.00
S3.00
232
87.00
81.00
5 00
4*5
105.00
M.00
13.00
460
113.00
108.00
81.00
Tankless heaters with controls (or water boilers: L8124E
combination immersion control-relay packed in trim box
in place of standard limit control.
$4.45
Tankless heaters with controls lor steam boilers: L4006A
immersion operating control packed in trim box in addi
tion to PA404A pressure limit control.
$16.90
Water flow regulator. Specify on order. Added Trade
Price ........................................................................................................
(1) Additional L4006A operating control required for steam boiler-heater combinations shown shaded. Add to above heater w/control Trade Price ............................
G-40
F.M. or F.I.A. ooulpmont F.I.A. requires tpocial
train PLUS F.I.A. electronic panol
F.M. & F.I.A. GAS CONTROL EQUIPMENT (GAS TRAIN ONLY)
BOILER NUMBER
ADO TO BOILER TRADE PRICE W
F.M.(')
F.l A.H
G-403 thru G-4014
$112.00
$589.00
*i> F M gas control equipment includes two manual shut*oM valves, a test vent valve and one AH2/V710 Hydromotor Valve
'! F l A. gas control equipment includes two manual snut-oH valves, hi and LO o'essure switches, two AH2/V71Q Hydromotor Valves and a vent valve
Note: A low water cut-ofF for water boilers (50 lb. or 80 lb. water working pressure) will be furnished as required.
No. 63 ............................................................ Trade Price 157.50 No. 150 ......................................................... Trade Price $85.90
Boiler
HEATER 218 HEATER 222 HEATER 226 HEATER 232 HEATER 445 HEATER 460 Steam Water Steam Water Steam Water Steam Water Steem Water . Steam . Water
HH-75-1 See page 48
Page 16
07624
AMERICAN
brJSTANDARD
HTORONIC HEATING
tankless heaters-gas fired WATER AND STEAM
G-10 BOILERS -- TANKLESS OR TANK TYPE HEATER
No. 1023 heater is available in any quantity. Specify number
required. Trade Price each
$45.40
G-10
F.M or F.l A. quipmenl F.l A' require, ,oeciei gas train PLUS F i A electronic nanet
The ratings table un Ibis page shows the ratings attained if more than one heaterisconnected in parallel.
Copper pipe manifolds, factory assembled for multiple heater parallel hookup, shipped in boxes of 2 manifold assemblies per box, when specified with heaters, are avail able at the following charges:
Manifold Assembly Two Heater Three Heater Four Heater
Trade Price
$9.85
514.95
$18.75
All G-10 water boilers and sizes G-105S thru G-1014S steam boilers can be provided with sections for insertion of heaters at no extra charge, add suffix letter T to boiler number and specify the number of sections with heater openings. Cover plates to close unused water heater openings will be furnished only if specified on order at Trade Price each ..................................................................... $6.05
When specified, the G-10 water boiler with heater can be provided with the combination L8124E in place of the L4006A limit control. Trade Price ............................... $22.00
F.M. A F.l.A. GAS CONTROL EQUIPMENT (GAS TRAIN ONLY)
ADO TO BOILER TRADE PRICE
BOILER NUMBER
G-105 thru G-106 G-107 G-108 thru G-1011 G-1012 thru G-1017 G-1018 G-1019 thru G-1030 G-1031 thru G-1033
FU.C)
5 98.00 115.00 101.00 164.00 221.00 229.00 294.00
F.I.A.O
SS91.00 637.00 770.00 878.00 957.00
1019.00 1185.00
F.M. gas control squioment includes two manual shut-ofi valves, a test vent valve and one AH2/V710 Hydromotor Valve
'2' F.l.A gas control equipment includes two manual shul-olf valves. Hi and 10 pressure switches, two AH2/V710 Hydromotor Vsives and a vent ve've
When No. 1023 heaters are used in steam boilers, the L4006A operating control will be required for installation in a heater tapping. Trade Price .................................. $16.90
When the NTo. 1023 heaters are used in a storage type domestic hot water system, the L4006A operating control will be required for insertion in a storage tank. Trade Price ............................................................................................$16.90
NO. 1023 HEATER RATINGS TANKLESS APPLICATION
boiler number
no. of tankless
heaters
intermittent draw
heater rating
gpm @ 100 rise
pressure drop (with manifolds)
PSI
G-105 - G-1033 G-105 - G-1033 G-106 - G-1033 G-108 - G-1033
1 2 3 4
41/4
7Vz 10
12 3/
NOTE: Heaters for Steam Boilers available 5 thru 14 sections only.
19 14
12 11
STORAGE TANK APPLICATION
boiler number
number of
boaters
continuous draw
100 rise
ipm
recovery
capacity 100 rise
gph
boiler
output required
mbh
G-105 - G-1033 G-105 - G-1033 G-106 - G-1033* G-108 - G-1033
G-lOll - G-1033 G-1013 G-1033 G-1014 - G-1033 G-1016 - G-1033
G-1018 - G-1033 G-1020 - G-1033 G-1022 - G-1033 G-1024 - G-1033
1 2 3 4
5 6 7 8
9 10 11 12
4
240
200
7
420
350
10 600 500
13 780 650
16
960
800
19 1.140 950
22
1.320
1,100
25
1,500
1,250
28
1.680
1,400
31
1.860
1,550
34
2.060
1.700
37
2.220
1.850
NOTE: Hatters for Steam Boilers available 5 thru 14 sections only.
storage tank size gale.
500 500 500 1,000
1,000 1,000 1.500 1,500
1.500 2,000 2,000 2,000
See page 48
Page 17
HH-75-1
07625
ELECTRONIC CONTROLS
.AMERICAN kSJ STANDARD
hyoronic heating
GAS BOILER ELECTRONIC CONTROL PANEL SYSTEMS
-- (FOR IIS VOIT. 40 CYCLE 1 PHASE POWER ONLY)
Panel System EPG-M: Provides manual ignition, 1009c safety shut-off with electronic supervision of pilots 1 to 3. Main burners and pilots are turned off on pilot failure. Continuous flame pilot operation. Equipment includes: one panel for each electronic pilot (Main panel plus 1 or 2 auxiliary panels) prewired and factory assembled; Baso valves and thermocouples and Q-179B electronic flame rod and pilot; RA890F protectorelay installed on panel; 3 ft. flame rod wire per pilot.
Panel System EPG-ES: Provides electronic supervision of each pilot (1 to 3) and interrupted continuous burning pilot electronically turned off and electrically relighted on every cycle to achieve positive component check of relays and pilot system. Complete automatic operation of boiler. 100% safety shut-off. Equipment includes: one panel for each electronic pilot (Main panel plus 1 or 2 auxiliary panels) prewired and factory assembled; Q179A flame rod and electric ignition pilots; ignition transformer; V4046C pilot solenoid valves; RA890F protectorelay installed in panels with 2-4 seconds response timing and alarm con tacts; minimum of 3 ft. of flame rod wire and 3 ft. of ignition cable per pilot.
Panel System EPG-E: Provides electronic supervision of each pilot (l to 3) and intermittent electric ignition of all pilots. Complete automatic operation of boiler. 100% safety shut-off. Equipment includes: one panel for each electronic pilot (Main panel plus 1 or 2 auxiliary panels) prewired and factory assembled; Q179A flame rod and electric ignition pilots; ignition transformer; V4046C pilot solenoid valves; RA890F protectorelay installed in panel with 2-4 seconds response timing and alarm contacts; minimum of 3 ft. of flame rod wire and 3 ft. of ignition cable per pilot.
Panel System EPG-M(FIA): Specifically designed to meet FIA requirements. Provides constant burning manually lighted electronically supervised pilots (1 to 3). 100% safety shut-off. Equipment includes: one panel for each electronic pilot (Main panel plus 1 or 2 auxiliary panels) prewired and factory assembled; alarm bell, alarm silencing switch; purge timer, all factory assembled in master panel; RA 890F protectorelay installed in panel; Baso valves and thermocouples and Q-179B electronic flame rod pilot; 3 ft. flame rod wire per pilot.
ADDITIONAL CHARGES-^-Trade Price
Specify on order type of system desired, as described above, and add charge for boiler size involved to Trade Price of boiler with regular equipment.
PANEL SYSTEMS EPG-M
boiler no.
system no.
GW. U-40
EPG-M1
G-105 thru G-1012
EPG-M1
G-1013 thru G-1023
EPG-M2
G-1024 thru G-1033
EPG-M3
added eharpe (1) $250.00 250.00 480.00 718.00
PANEL SYSTEMS EPG-E
boiler no.
system no.
GW. G-40
EPG-E1
G-105 thru G-1012
EPG-E1
G-1013 thru G-1023
EPG-E2
G-1024 thru G-1033
EPG-E3
added charge (t) $276.00 276.00 508.00 762.00
PANEL SYSTEMS EPG-ES
boilor no.
system no.
edded charge (1)
GW, G-40
EPG-ES1
$329.00
G-105 thru G-1012
EPG-ES1
329.00
G-1013 thru G-1023
EPG-ES2
561.00
G-1024 thru G-1033
EPG-E S3
817.00
PANEL SYSTEMS EPG-M(FIA)
bolter no.
system no.
added charge
GW, G-40
EPG-MI(FIA)
$455.00
G-105 thru G-1012
EPG-MI(FIA)
455.00
G-1013 thru G-1023
EPG-M2(FIA)
696.00
G-1024 thru G-1033
EPG-M3(FIA>
946.00
Flame Rod Wire: Trade Price per foot.............. Ignition Cable: Trade Price per foot ..........
$ .50 $1.05
<'> Not*. i purge timer n desired, specify on order end add $75.00 Trede Price
'Trade prices apply to equipment when shipped with boiler. For field conversions, price on application.
HH-75-1 See page 48
Page 18
07626
rWlAMtKIUMN
kJ STANDARD
HYDRONIC HEATING
PACKAGED BOILER-BURNER UNITS
WATER ONLY
DP (T)-95/105 PACKAGED BOILER-BURNER UNITS
Bsilcr-burnsr unit, dry base design--with DH-F flame retention burner (J.725 KPM). Nozzles-for two firing rates provided. Furnished with controls for forced circulation. Tested and equipped for 30 lbs. water working pressure. 115/60/1 electrical charac teristics.
WATER
packaged unit
number
groaa l=B=R
output mbh
l=B=R burner
capacity
gpi>
lanklatt heatar number
tankleaa heater capacity
gpm
nat l=6 = R
rating
mbh
nat rating aq. ft. wattr
Trad# Pr.ca with
atandard aquipmant
approi. hipping weight
neola ams
Packaged unite with factory installed tankless heater with R-8182D Aquastat-relay combination, high limit, low limit and circulator control, light sensing primary control.
DPT-9S DPT-105
95 105
.90 1.00
218 218
3
82.6
550 $686.00 496
.90-80`S
and
3 91.3 608 686.00 496 1 00-80`S
Packaged unit* lea* tankless heater with L4080B Aquastat limit contiol, and separate R8184G light sensing primary control.
DP-95
95 .90 --
DP-105 105 1 00
-- 82.6 550 $636.00 91.3 608 636.00
Gallons of water per minute from 4Q*F to 140*F with 200eF boiler water temperature NOTE. Water volume 9.6 gallons.
481 481
.90-80`S and
1 00-80`S
Standard equipment:
Model DH-F Arcoflame oil burner with sling mounting cad cell, bracket and leads.
T822D thermostat. Light weight fire brick combustion chamber.
Nozzles--Two (high firing and low fir ing rate) each boiler. Draft regulator. ASME relief valve. Pressure and temperature gauge.
circulator and piping. Wiring harness. Drain valve.
Optional equipment:
Two-stage fuel unit for DH-F oil burn er. Specify on order. Trade Price... S8.30
Ordtring Examples:
,1. Pockaged unit with heoltr with stondord equipment: 1 DPT'95 boiler-burner unit
2. Pockaged unit less heofer with standard equipment: I DP-95 bailer-burner unit
W" See page 48
Page 19
For complete specification* refer to Technical Catalog Bulletin Form No. 72131*2 (6/72>
HH-75-1
07627
PACKAGED boiler-burner units
WATER ONLY
^AMERICAN fiJSTANDARD
HYDRONIC HEATING
VP(T) PACKAGED BOILER-BURNER UNITS
Boiler-burner unit--wet base design--with DH-F flame retention burner (1725 RPM). Nozries for multiple firing rates provided. Furnished with controls for forced circula tion. Tested and equipped for 30 Its. water working pressure, lio/60/i electrical characteristics.
WATER
No. Sactiona
packaged untt
number
grou
l=0=A output
mbh
l=8=fl burner capacity
gpb
ton Mot* beeter number
tankless heater capacity
gpm
not IsBsft
rating mbh
net rating
aq. ft. water
Trade Price with
standard
equipment
appro s.
Nipping weight
water volume
(Bel.)
noate txaa
Packaged unit* with factory Installed tankless heater W`.th R8l82D Aquastat-relay combination, high limit low limit
*9
and circulator control, light sensing primary control.
VPT-115
115
1.05 130 315 100.0 667 $ 737.00 575
15.6
1.00-80 Hago ES
and
3
VPT-130
130
1.15 130 3V5 113.0 753 737.00 575
15.6
1.10-80' Hago ES
VPT-140
140
1.25 130 3 Vz 122.0 814 737.00 575
15.6 1.25-80' Hago ES
4
VPT-170
170
1.50 131
4V 147.8 985
890.00
685
20.0
1.50-80' Hago ES and
VPT-190
190
1.70 131
4V 165.2 1102
890.00
685
20.0
1.65-80' Delevan B
VPT-230
230
2.05 132 6
200.0 1333 1004.00 795
24.4
2 00-70' Monarch R
5 and
VPT-250
250
2.25 132 6
217.4 1449 1004.00 795
24 4
2 25-70" Monarch R
Packaged units lest tankless heater
With R8182F Aquastat-relay combination, limit and circulator control, light sensing primary control, one heater opening cover plate.
- vp-rts--- 115
1.05
100.0
667 * 686.00
560
15.6
1 00-80 Hago ES
and
3
VP-130
130
1.15
--
-- 113.0 753
686.00 560
15.6
1,10-80 Hago ES
VP-140
140 1.25
122.0 814
686.00 575
15.6
1.25-80 Hago ES
VP-170
170
1.50
--
-- 147.8 985
838.00 670
20.0
1.50-80 Hago ES
4 and
VP-190
190
1.70
--
-- 165.2 1102
838.00 670
20.0
1.65-80 Delevan B
VP-230
230
2.05
--
-- 200.0 1333
926.00 780
24 4
2.00-70 Monarch R
5 and
VP-250
250 2.25
217.4 1449
926.00 780
24.4
2.25-70" Monarch R
'Gallons of water per minute Irom 40F to 140'F with 200*F boiler water temperature.
Standard equipment:
Model DH-F Arcoflame oil burner with sling mounting cad cell, bracket and leads. T822D thermostat. Pre-cast refractory combustion target wall.
Draft regulator. ASME relief valve. Pressure and temperature gauge. H4" circulator with piping. Wiring harness. Drain valve.
Ordering ExompUt:
1. Pockoged unit with heater with standard equipment: 1 VPT-1 15 boiler-burner unit
2. Packaged unit less healer with standard equipment: 1 VP-M5 boiler-burner unit
Optional equipment:
Zone valve packages are available for water boilers. For details and prices, see page 33. Two stage fuel unit for DH-F oil burn er--specify on order. Trade Price... *8.30 Jacket extension. Trade Price...... $35.00 R-8182-D Aquastat relay combination for use with tankless coils for conver sion of boiler without tankless heater. Trade Price add ..................................*7.70 For tankless heatev information, see page 23.
HH-75-1 See page 48
Page 20
for complete specification* refer 10 Technical Catalog Bulletin Form No 7263-2 (Rev 8-'74|
07628
_ AMERICAN 5J STANDARD
HYDRONIC HfATING
NON-PACKAGED BOILER-BURNER UNITS
WATER AND STEAM
V-3 NON-PACKAGED ALL-PURPOSE BOILER-BURNER UNITS
Boiler-burner unit--wet base design--with DH-F flame retention burner (1725 RPM). Sections assembled--nozzles for two firing rates provided. Flexible for steam, water, forced or gravity circulation--with or without tankless heater. 30 lbs. water working
lbs. steam. 115 volt, 60 cycle, single stage electrical characteristics.
WATER
WBT Forced circulation units with factory Installed tankless heater include R8182D aquastat-relay combination, high limit, low limit and circulator control, light sensing primary control.
WB Forced circulation units less heater include R8182F aquastat combination, limit and circulator control, light sensing pri mary control.
Section Desgnatior
bolter burner
unit number
groat 1=0=*
output mbh
1=0=0 burner
capacity gph
tankleaa heater
number
Unkless heater rating
gpm
net l = 0=ft
rating mbh
r Trade Price tirade Price
net standard standard
rating aquipmant equipment
ataam
leas
with
sq. ft tankleaa
tankleaa
approk. shipping
weight
node used
V-33
V3-116WB(T) V3-128WBfri
116 128
1.05 1.15
222 222
4 4 4K
V3-172WB(T) 172 1.55 226 5
V3-186WBfT1 186 1.70 226 5 4
V3-228WB(T) 228 2.10 232 7
V3-244WBfTf 244 2.25 232 7
V3-284WB(T) 284 2.60 445 8'/4
V-36 V3-302WB(T)
302
2.80
445
8'/4
100.9 111.3 149.6 161.7 198.3
212.2 247.0 262.6
___ $ 613.00
-- 613.00 -- 789.00 -- 789.00 -- 957.00 -- 957.00
-- 1112.00 -- 1112.00
t 656.00
656.00 846.00 846.00 1026.00 1026.00 1199.00 1199.00
613
613 790 790 967 967 1144
1144
1 00-80* Hago ES
1.10-80* Haoo ES 1.50-80" Hago ES 1 65-70" Haoo ES 2.00-70' Monarch R 2 25-70* Monarch R
2.50-70 Delevan B 2.75-60' Delevan B
WBG Gravity units less heater includes L4080B aquastat limit control, and separate R8184G light sensing primary control.
V3-116WBG V3-126WBG
116 1.05 128 1.15
_ _
_ 100.9 _ 607.00 Not Avail. 613 1.00-80* Hago ES
-- 111.3 -- 607.00 Not Avail. 613 1 10-80* Haoo ES
V-34
V3-172WBG V3-186WBG
172 1.55 186 1.70
V3-228WBG
228 2.10
T V3-244WBG 244 2.25
V3-284WBG V-36 V3-302WBG
284 302
2.60 2.60
--_ _ _ _
--
_--
149.6 161.7
--_
783.00 Not Avail. 763.00 Not Avail.
790 790
1.50-80' Hago ES 1 65-70* Haao ES
-- 198.3 -- 952.00 Not Avail. 967 2.00-709 Monarch R
--
_
212.2 247.0
-- 952.00 -- 1107.00
Not Avail. Not Avail.
967 1144
2.25-70c Monarch R 2.50-70* Delevan B
-- 262.6 -- 1107.00 Not Avail. 1144 2.75-60" Delevan B
STEAM
SBT Steam units with factory installed tankless heater includes PA404A Pressuretrol, L4006A aquastat operating control, ana separate R8184G light sensing primary control.
SB Steam units less heater include PA404A Pressuretrol, and separate R8184G light sensing primary control.
V-33 V-34
V-36
V3-116S8(T) V3-128SBfT1 V3-172SB(T) V3-1B6SBfn
V3-228SB(T)
V3-244SBfT) V3-284SB(T) V3-302SB(T)
116
128 172 166 228 244
284
302
1.05 222 4'/i 1.15 222 4%
1.55 226 5 V* 1.70 226 5 Vi
2.10 232 6% 2 25 232 6 Vi 2.60 445 7 y. 2.80 445 7 Vi
87.1 363 607.00
96.0 400 607.00
129.1 538 763.00
139.4 591
7B3.00
171.1 713 952.00
183.1 763 952.00
213.1 888 1107.00
226 6 944 1107.00
548.00 548.00 708.00 708.00 857.00 857.00 1000.00 1000.00
613
613
790 790
967 967
1144 1144
1 00-80' Hago ES
1.10-80' Haoo ES 1.50-80 Hago ES
1 65-70* Haoo ES
2.00-70 Monarch R 2.25-70* Monarch R 2 50-70* Delevan B
2.75-60* Delevan B
A Gallons of water per minute heated from 40*F to 140*F with 200*F boiler water temperature.
W See page 48
Standard equipment:
Model DH-F Arcoflame oil burner sling mounting, cad cell, bracket and leads. T822D thermostat. Pre-cast refractory combustion target wall.
Draft regulator. Drain valve. Units WITH water heater: 1 cover plate with control tapping. Units LESS heater: 2 cover plates for heater openings.
Wafer: ASME relief valve. Pressure and temperature gauge.
Steam: ASME safety valve. Steam gauge. Gauge glass with trimmings.
Ordering Examples: 1. All-Purpose boiler-burner unit with standard equipment: For forced circulation, with heater: 1 V3-116/128WBT boiler-burner unit For gravity circulation: 1 V3-172/186WBG boiler-burner unit 2. All-Purpose boiler-burner unit with optional equipment: For forced circulation, less heater: 1 V3-228/244WB boiler-burner unit with stage fuel unit.
Optional equipment:
Zone valve packages are available for water boilers. For details and prices, see page 33. Others--see page 23.
Page 21
For complete specifications refer to Technical Catalog Bulletin Form No. 73-166*2 (6/73)
HH-75-1
07629
NON-PACKAGED OIL FIRED BOILERS WATER AND STEAM
^AMERICAN L5d STANDARD
HYDRONIC HEATING
V-3M ALL-PURPOSE OIL FIRED BOILERS
The non-packaged all-purpose boiler only, with sections factory assembled, tested and equipped for 30 psi working pressure for water, 15 psi steam.
WATER
WT--Forced circulation boiler only with factory installed tankless heater. W--Forced circulation boiler only less healer.
Section Designation
boiler number
V-34M V-36M
V3M-92W(T) V3M-110Wfn
V3M-138W(T) V3M-1S6Wm V3M-184W(T) V3M-202Wfn
V3M-230W(T) V3M-248W(T)
grota l=B=* output
mbh
92 110 138 156 184 202 230 248
IsBsft burner capacity
gbh
.85 1 00
1.30 1 45 1.70 1.90 2.15 2 35
tankleaa heater number
222 222 226 226 232 232 445 445
tankleaa heater rating gpm
4 4
5 5 6 6 7 7
net |=B=R
rating mbh
80.0 95.7 120.0 135.7 160.0 175.7 200.9 215.7
Trade Price standard equip.
lets tankleaa heatar
$327.00 327.00 437.00 437.00 560.00 560.00 664.00 664.00
Trade Price standard equip,
with tankleaa heatar
$355.00 355.00
478.00 478.00 610.00 610.00 729.00 729.00
approx. shipping weight aection
saa'y
613 613 790 790 967 967 1144 1144
STEAM
ST--Steam boiler only with factory installed tankless heater. S--Steam boiler only.
Section Designation
belter number
8 roes i=b=r output
mbh
l=BsR burner
capacity
gbh
tankleaa
heater number
tankless healer rating gpm
net 1= B -- R
rating mbh
net 'W Trid. Pries ^ Trade Price
l=B = R standard equip, tandard*equip.
aq. ft.
less lankiest
with tankleaa
steam
heater
heatar
V.11M V3M-92S(T) V3M-110S(T1
92 110
.85 1 00
222 222
4 4
69.0 82.5
288 344
V-34M
V3M-138S(T) V3M-156Sm
138 156
1.30 1.45
226 226
5 103.5 431 5 117.0 489
v*j3 nn
V3M-184S(T) V3M-202Sm
184 202
1.70 1.90
232 232
6 138.0 575 6 151.5 631
V3M-230S(T)
230
2.15
445
7 173.3 722
V3M-248S(T)
248
2.35
445
7 186.0 775
327.00 437.00 437.00 560.00 560.00 664.00 664.00
355.00 478.00 478.00 610.00 610.00 729.00 729.00
A Gallons of water oer minute heated from 40*F to 140*F with 200*F boiler water temoerature. Only oil burners capable of developing 10^> CO,, such is the OH-5 burner, may be used wun V-3M oil fired boiler*.
approx. shipping weight section
tta'y
613 613 790 790 967 967 1144 1144
HH-75-1 'V See page 48
Standard equipment: Pre-cast refractory combustion chamber. Drain valve.
Water: ASME relief valve. Pressure and temperature gauge.
Steam: ASME safety valve. Steam gauge. Gauge glass with trimmings.
Optional equipment: See page 23.
Note: Boilers with factory installed tankless
heater are shipped with one water heater
opening.cover plate with
control tap
ping. Boilers less factory installed heatei
are shipped with an additional water heater
opening cover plate (blank).
Zone valve packages are available for water
boilers. For details and prices, see page 33.
Ordering Examples:
1. Water boiler less heater with standard equip ment: 1 V3M-92/110W boiler
2. Steam boiler with heater with standard equip ment: 1 V3M-138/156ST boiler
3. Water boiler with heater with optional equip ment: 1 V3M-230/248WT boiler with jacket ex
tension
Page 22
For complete specifications refer to Technical Catalog Bulletin Form No 73-166-2 (6/73}
07630
i a w \jvtl_f\IN-rVIN
SiSTANDARD
HYDRONIC HEATING
OPTIONAL EQUIPMENT OIL FIRED BOILERS
OPTIONAL EQUIPMENT
VP(T) PACKAGED BOILER-BURNER UNITS V-3 NON-PACKAGED BOILER-BURNER UNITS V-3M NON-PACKAGED BOILER ONLY
JACKET EXTENSIONS
V-3 and V-3M jacket extension provides 17 Ai" acoustical enclosure in front for concealment of oil burner and con trols--specify on order. Trade Price Add .................$50.60
LOW WATER CUT-OFF--McDonald ti Miller No. 67AR low water fuel cut-off. Trade Price .....................................$43.00
Controls and control sets are shown on page 31.
MISC. V-3 BOILER-BURNER UNITS
Two-stage fuel unit. Trade Price ................................... $8.30
Order R8182D Aquastat-relay combination to permit use of tankless heater with boiler-burner units furnished less water heater. Trade Price ............................................... $7.70
Order R8182E Aquastat-relay combination to provide room thermostat control of circulator. Trade Price.... $6.00
FOR V-3 ALL-PURPOSE AND VP(T)
BOILER-BURNER UNITS
For substitution of No. 4 control set consisting of T822D thermostat, L4081B Aquastat limit and circulator control, plus R8184G light sensing primary control, instead of R8182F combination control, for non-packaged boilerburner units for forced circulationLESS heater. Added Trade Price .......................................................................... $15.30
For substitution of No. 5 control set consisting of T822D thermostat, L8124C Aquastat, limit, reverse and operating control, circulator relay, plus R8184G light sensing pri mary control, instead of R8I82D combination control, for non-packaged boiler-burner units for forced circulation WITH tankless heater. AddedTrade Price ................. $6.05
The No. 5Z Control Set can be used for circulator zoning with boiler-burner units with tankless heater. 1 No. 5Z set is required for each zone in addition to the first zone which is controlled by the No. 5 Control Set or equivalent. Added Trade Price ......................................................... $30.05
TANKLESS HEATERS FOR V-3, V-3M AND VP BOILERS
Heaters can be ordered for separate shipment for use with units or boilers specified less heater as follows:
RATINGS--Gallons ol water per minute from 40'F to 140`F with 200'F boiler water temp.
boiler number
HEATER 222 HEATER 226 HEATER 232 HEATER 445 HEATER 130 HEATER 131 HEATER 132 Steem Water Steam Water Steem Weter Steem Weter Steem Water Steam Water Steam Water
V3-116/128
4Va 4%
V3-172/186
4 y4 4%
V3-228/244
4 V4 4%
V3-284/302
41/4 4%
V3M-92/110
4 41/2
V3M-138/156
4 41/2
V3M-184/202
4 4'/2
V3M-230/248
4 41/2
VP.-115/130/140 -- --
VP-170/190
_--
VP-230/250
51/4 5% 51/4 5% 5'/4 5%
5 51/2
5 51/2
5 51/2
--
--
--
--
61/4 7 61/4 7
6 6% 6 6% ---- ----
71/4 8V4
7 7% ---- ----
--- ---
--- ---
-- 31/2 -- 3'/2 -- 31/2
----
--
--
--
--
-- 4 ye -- 4%
----
----
--
--
---- --6
Note: Because of unique boiler design a second heater may be installed in V3 and V3M water boilers which will increase the intermittent draw rating.
* Appropriate controls must be ordered in addition to heater only above.
Trade Price*
HEATER HEATER ONLY NUMBER Wtr A Stum
222 $39.00 226 53.00 232 65.00 445 83.00 130 43.00 131 43.00 132 69.00
See page 48
Page 23
HH-75-1
07631
NON-PACKAGED PRESSURE FIRED
BOILER-BURNER UNITS WATER AND STEAM
fZJAMERICAN SJ STANDARD
HYDRONIC HEATING
PFA-3 PRESSURE FIRED BOILER-BURNER UNITS
Jacketed--forced draft with flame retention oil burner. Sealed sections--with or without tankless heaters. 50 lbs. water working prpseuvA, 15 lh<5 steam _ 115 volt, 60 cycle power supply.
WATER
burner unit
bumbar
in.
ewtewt MM
e la|sk burner cs^Blty
task!**
number
t
IsWuH rating
Ml
ln|s| rating
MM
net rotinf . ft. meter
Trade We#
with
standard
equipment
naprei.
ihleeinf
weight
rent site dtom. In.
Forced circulation units with factory Installed tankless heater : No. 5 control set -- T8220 thermostat, L0124C Aouastat. reverse and operating control, circulator relay, R0184G light sensing primary control.
PFA-34- WT PFA-35-WT PFA-36-WT PFA-37-WT
300 375 450 526
2.65
226
6.0
260.9
1739
$1234.00
3.30
232
7.5
326.1
2174
1396.00
3.95
445
9.0
391.3
2609
1563.00
4.60
445
9.0
457.4
3049
1713.00
905 1096 1287
1481
8 8 8 8
Forced circulation units less heiter: No, 4 control set -- T822D thermostat, L4081B Aquastat limit ana circulator control. RS104G light sensing primary control.
PFA-34-W P FA-35-W PFA-36-W PFA-37-W
300 2.65 375 3.30 450 3.95 526 4.60
260.9 326.1
391.3 457.4
1739 2174
2609 3049
51167.00
1316.00 1466.00 1617.00
894 1085 1276 1470
8 a 8 8
STEAM
bailer. burner
vmi
number
(nil i = a=t output
Mbh
i = a= burner capacity
04*
twtkleis hearer number
IsWsH
rating
mi 1 = 1=1
rating MM
net ! = B=t
q. ft. ifearn
*W Trade
Price with standard equipment
epprex. ihipaing weigh*
vent rite di'am. in.
Steam units with actory installed tankless heater: No. 2 control set -- T022O thermostat. PA4Q4A Pressuretroi. L4006A Aquastat operating control, R81B4G light sensing primary control.
PFA-34-ST
300
2.65
226
6.0 225.1
938
$1231.00
90S 8
PFA-35-ST
375
3.30
232
7.5
281.3
1172
1393.00
1096
8
PFA-36-ST
450
3.95
445
9.0
337.6
1407
1560.00
1287
8
PFA-37-ST
526
4 60
445
9.0
394.6
1644
1710.00
1481
8
Steam units less neater: No. 1 control set--T8220 thermostat. PA404A Pressuretroi. R8184G light sensing primary control
PFA-34-S PFA-35-S PFA-36-S PFA-37-S
300 2.65 375 3 30 450 3.95
526 4.60
225.1 281.3 337.6 394.6
938
1172 1407 1644
$1161.00 1313.00 1460.00 1611.00
900 1091 1282 1476
8 8 8 8
'Nozzle sues furnished with the above units: (S -- solid; M -- hollow) PFA-34. 2.50 gph 70* S. PFA-35 3.25 gph 45* S' PFA 36. 4.00 gph 45* S; PFA-37. 4 50 gph 30* S
tGaMons of water per minute heated from 40*F to t40`F with 200*F boiler water temperature.
Vent needs to extend 3 feet above highest part of roof. Start-up service -price on application.
Standard Equipment
Water: ASME relief valve Pressure and temperature gauge
Flange mounted oil burner with 2-stage fuel unit; factory installed light sensing cad cell with bracket and leads: V4046B
instantaneous oil valve; Syracuse elec tronic time delay; drain valve.
buiUr-bumur nit
PFA-34 PFA-35
il burner
LC-334-A3 LC334-A
boiler-burner unit
PFA-36) PFA-37 (
oil burner
LC-534-A
Units WITH water heater: 1 cover plate with %" control tapping.
Units LESS water heater; 2 cover plates for heater openings.
Steam; ASME safety valve Steam gauge Gauge glass with trimmings
Optional Equipment
Available in split assemblies. Specify on order. Trade Price ...........................525.50 Zone valve packages are available for water boilers. For details and prices, see page 33. For other optional equipment see page 25.
Ordering Examples:
1. Pressure fired boiler-burner unit with standord equipment with heater for wottr: \ PFA-34-WT boiler-burner unit
2. Pressure fi rod boiler-burner unit with optionol equipment less heater for ittom: \ PFA-37-5 boiler-burner unit with jacket extension
HH-75-1 "W See page 48
Page 24
For complete specifications refer to Technical Catalog Bulletin Form No 9114-2 (Rev. 0/74)
07632
HYORONIC HEATING
PFA-3 OPTIONAL EQUIPMENT
PRESSURE FIRED BOILER-BURNER UNITS
WATER AND STEAM
Jacket extension. TradePrice ......................................... $50.60
No. 5-Z control set for circulator zoning with PFA-3 boiler-burner unitsequipped for tankless heater. 1 No. 5-Z set required for each zone in addition to the first zone which is controlled by the No. 5 control set or equivalent. Trade Price ......................................................................... $30.05
McDonnell & Miller No. 67AR low water fuel cut-off for steam. Trade Price ......................................................$42.35
McDonnell & Miller No. 63 low water cut-off for water. Trade Price ......................................................................... $57.50
Controls and control sets are shown on page 34.
I=W=H RATED BUILT-IN TANKLESS WATER HEATERS FOR PFA-3
Heaters tested with boilers. Built-in tankless heaters can be ordered /or separate shipment with units or boilers specified less heater as follows:
(Mil ft*.
PFA-34 PFA-35 PFA-36 PFA-37
Istst burner capacity
gpA
2.65 3.30 3.95 4.60
heater i*e.
226 232 445 445
laws 1 rotinf
water
steam
6.0 6.0 7.5 7.5 90 90 9.0 9.0
rtirw heater at rated flew
23 psi 36 psi 37 psi 37 psi
healer only* 'Trade Frit*
$53.00 65.00 83.00 83.00
Go Hem *f water pr minute from 40*F fo I40*F wi*h ?00*F beilor voter temperon "Appropriate controls must be ordered m addition to healer only above.
"W See page 46
Page 25
HH-75-1
07633
Oil BOILER-BURNER UNITS
STEAM AND WATER
PFA-5 PRESSURE FIRED BOILER-BURNER UNITS
Jacketed--forced draft with oil burner. 60 lbs. water working pressure--15 lbs. steam working pressure. Equipped for tankless heaters.
pressure fired Seller burner unit number
ell
frees ll~t
output MM
1 wt-t
Sumer capacity
ell fph
RifIn* and pickup feeter
sterna
water
net Inlnl ratio*
MM
steam
water
sq. ft. roam
net ratio*
sq. ft. water
Trade Price with standard equipment
41
vent site dlam. in.
appre** imate
shippin*
weight
burner medel supplied with standard equipment
<n
' all
PFA-504-* 0(T) PFA-505-* 0(T) PFA-505-* O(T)
620 786 950
5.45 6.90 8.35
1.333 1.333 1 333
1.15 1.15 1.15
465.1 589.6 712.7
539.1 683.5 826.1
1938 2457 2969
3594 4557 5507
$1944.00 2291.00 2554.00
10 10 10
1640 2210 2520
95A-1-6702-JBT 96A-M-6131-JC-T 96A-M-6131-JC-T
PFA-507-* 0{T) PFA-508-* 0(T) PFA-5 09-* O(T)
1116 1282 1446
9.80 11.20 12.65
1.333 1.330 1 315
1.15 837.2 970.4 1.15 963.9 1114.8 1.15 1099 6 1257.4
3488 4016 4582
6469 7432 8383
2924.00 3241.00 3469.00
10 10 14
2880 3190 3550
96A-B-8316-JC-T 96A-B-8318-JC-T 96A-B-8318-JC-T
PFA-510-' O(T) PFA-511-* 0(T) PFA-512-* 0(T)
1612 1776 1944
14.10 15.55 16.95
1 302 1 292 1 288
1.15 1238.1 1401.7 1.15 1374.6 1544.3 1.15 1509 3 1690.4
5159 5728 6289
9345 10295 11269
4065.00 4714.00 5087.00
14 14 14
3935 4285 4645
96A-T-A-8419-JC-T 97A-T-A-8614-JC-T 97A-T-A-8614-JC-T
PFA-513-* 0(T) PFA-514-* 0{T) PFA-S1S-* 0{T)
2108 2272 2440
18.40 19.85 21.25
1.288 1 288 1.288
1.15 1636.6 1833.0 1.15 1764.0 1975.7 1.15 1894.4 2121.7
6819 7350 7893
12220 13171 14145
5331.00 5580.00 6101.00
14 14 14
4955 5317
5675
97A-T-A-8614-JC-T 97A-T-A-8615-JC-T 97A-T-2-7635-E-1
PFA-51S-* 0(T) PFA-517-* 0(T) PFA-S18-* O(T)
2604 2768 2936
22.70 24.15 25.60
1.288 1.288 1.288
1.15 2021.7 2264.3 1.15 2149.1 2407.0 1.15 2279.5 2553.0
8424 8954 9498
15095 16047 17020
6492.00 6720.00 7168.00
18 18 18
5985 6345 6750
97A-Hi-Lo-2-76B5-E-1 97A-HI-LO-2-7665-E-1 98A-Hi-Lo-2-7771-E-1
PFA-519-* 0(T) PFA-520-* O(T) PFA-S21-* O(T)
3100 3260 3430
27.00 28.45 29.90
1.288 1.288 1.288
1.15 2406.8 2695.7 1.15 2531.1 2834.8 1.15 2663.0 2982.6
10028 10546 11096
17971 18899 19884
7420.00 7663.00 7951.00
18 18 18
7060 7420 7780
98A-Hi-Lo-2-7771-E-1 98A-Hi-Lo-2-7771-E-1 | 98A-Hi-Lo-2-7771 -E-1
t
Height 3 feet obo*e highest port of root.
The net l = 6rrR ratings shown ore based on piping and pick-up allowances listed above. Americon.Stondard should be consulted before selecting o
boiler for installations having unusual piping and pick-up requirements.
A.eiiade as assembled unit or with assembled sections'--see page 27
*Subrtitut latter "S" for Hum; "W" for water. Start Up and Orta Year's Sarvica . .. Price on Application
Suffix (T) denote* boiler with opaningi in cantar taction for tankless heaters whan tpacifiad. For Built-in Water Heater*. sec page 27.
Nozzles sees--see cage
# Nozzle sizes, gpn, turnisneo with the above oil burners are as follows:
unit na. *ph. type
1
i
I
f
unit na. *ph. type
unit na. *pn. type
unit *- h. type
unit na. gph. typa
PFA-504 2 2.75 90`H PFA-505 2 3.50 90`H PFA-S0S 2 4.00 80 *H PFA-507 1 4.50 70`H
1 5.00 70`H
PFA-508 2 5.50 80`H
PFA-509 1 6.00 B0`H PFA-512 2 7.00 70`H PFA-514 1 3.50 60`H PFA-517 1 10.00 90`S PFA-520 1 8.00 80*S
1 6.50 B0"H
1 2.50 70`H PFA-51S 2 8.00 70`H PFA-511 1 7.50 90`S
1 8.50 80`S
PFA-510 2 5.50 90`H PFA-513 2 7.00 70'H
1 5.00 70`H
1 8.00 90`S
1 12.00 80`S
1 2.75 90*H
1 4.00 70`H PFA-516 2 7.00 90`S
1 10.00 90`S PFA-521 2 8.0Q 80*S
PFA-511 2 6.50 80`H
1 8.50 90'S PFA-519 2 7.50 80`S
1 14.00 80'S
1 2.00 80`H PFA-514 2 8.00 60H PFA-517 2 7.00 90`S
1 12.00 B0*S
HH-75-1 See page 48
Page 26
For complete soecitications reler to Technical Catalog Bulletin Form No 91T5-2 tRev 3 6^72>
07634
PFA-5 pressure fired boiler-burner units
Standard Equipment--All RoiUr*
Steam: PA404A Pressuretrol, ASME safety valve, steam gauge, gauge glass with trimmings, drain valve.
Water: L4006A Aquastat, ASME relief valve, pressure and temperature gauge, drain valve.
Standard Equipment--Oil Fired
Flange mounted oil burner--97A-T-A, 97A-T-2, 97A Hi*Lo and 98A Hi-Lo burners furnished with flange and pedestal. On 95-A1, 96A-M, 96A-B, 96A-T-A and 97A-T-A burners,
factory installed cad cell, bracket and leads, R8185E light sensing primary control; V4046B instantaneous oil valve, ST70A1002 electronic time delay. On 97A-T-2, 97A Hi-Lo-2 and 98A Hi-Lo-2 burners, R4150A control--provides prepurge and post-purge, Q520A base, factory installed C7013A photo cell; delayed and instantaneous oil valves,
nozzles. 2 stage fuel unit on all burners.
Standard Motor Voltage*
PFA-504 thru PFA-510 PFA-511 thru PFA-521
116/60/1 230/60/1
Ordering Example*-. PFA-5 boiler-burner unit for iteom with itandard equipment. 1 --PFA-514-SO boiUrbufthr unit PFA-5 boilr-burnar unit for wotir with optional *quipnsnt. 1-- PFA-511 -WO(T) with fockat axtaniion; 4 No. 543 tankiaii hootari; with 16006A control.
Optional Equipment--Oil Fired
Oil Burners equipped for F.M. or Massachusetts Code requirements for PFA-504 through PFA-514.
Added Trade Price ........................................................ *215.00
R,,,-n..-c fny PFA-515 through PFA 521 a.e equipped to meet F.M. requirements. (Equipment includes: R4150A which provides pre- and post-purge, C7013A Photo Cell and Q520A Base.)
Oil Burners for F.I.A. requirements--Price on application.
Oil burners for PFA-515 thru PFA-521 for Massachusetts Code requirements--Price on application.
Prewired Control Panels on burners--Prices on applica tion. Optional burners and assembly arrangements, listed be llow.
PFA-5 OPTIONAL ASSEMBLY AND OIL BURNERS
PFA-S04 PFA-505 PFA-506
PFA-507 PFA-508 PFA-509
PFA-510 PFA-511 PFA-512
PFA-51 3 PFA-514 PFA-515
PFA-516 PFA-517 PFA-518
PFA-519 PFA-520 PFA-521
ABC oil burner*
96A-T-A-8406 J8T 96A-T-A-84 08 JBT 96A-T-A-S408 JCT
SI 63.00 153.00 153.00
96A-T-A-8409 JCT 96A-T-A-8410 JCT 96A-HI-LO-A-8808 JCT
96.00 96.00 350.00
96A-HI-LO-A-8808 JCT 254.00
astamblad section*
$ 99.00 165.00 198.00
231.00 264.00 297.00
330.00 363.00 396.00
429.00 462.00 495.00
528.00 561.00 594.00
627.00 660.00 693.00
add to Trada Prica
packaged botlar unit
0 Ibt. water last
S666.00 684.00 702.00
719.00 737.00 848.00
869.00 889.00 910.00
929.00 949.00 969.00
990.00 1010.00 1031.00
1050.00 1071.00 1091.00
5 44.00 55.00 66.00
77.00 68.00 99.00
110.00 121.00 132.00
143.00 154.00 165.00
176.00 IB 7.00 198.00
209.00 220.00 231.00
jacket extension
S85.15 65.15 85.15
85.15 65.15 85.15
65.15 65.15 85.15
85.15 65.15 85.15
85.15 65.15 65.15
85.15 85.15 65.15
Gordon-Piatt oil burner*
RL 6 2-Q-03-F4B RL6 2-0-03-F48 RL 6.2-0-03-F4B
$62.50 61.00 61.00
RL 8 0-0-05-F4B RL 8 1-0-05-F4B RL 8 1-0-05-F4B
26.00 28.00 2B.00
RL 8 2-0-10-F4B RL 8.2-0-10-F48 RL 8 2-0-10-F4B
RL 8 2-0-15-F4B RL 8.3-0-15-F4B RL 6.4-0-20-F4B
RL 8.4-0-20-F4B RL 10.1 -0-2Q-F4B RL 10.1-0-20-F4B
RL 10.1-0-30-GP100R-F4B RL 10.1 -0-30-GP100R-F4B RL 10 1-0-30-GP10QR-F4B
77.00 __
--
_
__
--
_
__
--
__ _
--
W See page *6
Page 27
HH-75-1
07635
GAS BOILER-BURNER UNITS
STEAM AND WATER
PFA-5 PRESSURE FIRED BOILER-BURNER UNITS
Jacketed--forced draft with pas burner. 50 lbs. water working pressure--15 lbs. steam working pressure. Equipped for tankless heaters.
bmter-burwer util number
**
r*M i ==t
output Mbh
-Im-ftst burner
coo<itr
Input Mbh
piping Ad <kup farter
team water
net 1 t= I = rating
Mb* team water
I*, ft. team
PFA-504-* G(T) PFA-505-' G(T) PFA-506-* G(T)
620 786 950
763 966 1169
1.333 1.333 1 333
1.15 1.15 1.15
465.1 589.6 712.7
539.1 683 5 826.1
1938 2457 2969
net reting e ft. water
3594 4557 5507
'W Trod# Price with standard equipment
go*
3111.00 3434.00 3687.00
vent
lie diam.
in.
qprex* Itnate hipping
weight
burner medel tuppUed with standard equipment
10 1840 R6.2-G-03-R4795 B.12S 10 2210 R6 2-G-03-R4795-B.12S 10 2520 R6.2-G-03-R4795-B.12
PFA-507-* GIT) PFA-508-* G(T) PFA-509-* G(T)
1116 1282 1446
1372
1568 1771
1 333 1 330 1.315
1.16 837.2 970 4 1.15 963 9 1114.8 1.15 1099 6 1267 4
3488 4015 4582
6469 7432 8383
4114.00 10 2880 R8-G-05-R 4795-8.12 4446.00 10 3190 R8G-05-R4795-B.15 4674.00 14 3550 R8-G-G5-R4795-8.15
PFA-510-* G(T) PFA-511-- G(T) PFA-512-' G(T)
1612 1776 1944
PFA-513-* GIT) PFA-S14-* G(T) PFA-515-* G(T)
2108 2272
2440
1974 2177 2373
2576 2779 2975
1 302 1.292 1 288
1.288 1.288 1.288
1 15 1238 1 1401 7 1 15 1374.6 1544.3 1.15 1509 3 1690 4
5159 5728 6289
9345 10295 11269
1 15 1636.6 1833 0 1.15 1764 0 1975.7 1 15 1894 4 2121.7
6819 12220 7350 13171 7893 14145
5273.00 14 3935 R8.1G-05.R4795-B.20 5990.00 14 4285 R8.2G-05-4150AH.20 6386.00 14 4645 R8.3-G-10-41 50A-H 20
6699.00 14 4955 R10.9-G-10-4150A-H 20 6948.00 14 5315 R10 9-G-10-41 50A- H. 20 7170.00 14 5675 R10.9-G-10-41 50A-H 20
PFA-516-* G(T) PFA-517-* G(T) PFA-518-' G(T)
2604 2768 2936
3178
3381 3584
1.288 1 288 1.288
1 15 2C21 7 2264 3 1 15 2149 1 2407 0 1.15 2279 5 2553 0
8424 15095 8954 16047 9498 17020
7650.00
18 5985 R 10-G-15-4150A H 25S
7878.00 18 6345 R10-G-15-4150A-H 25S
8124.00 18 6750 R10.1-G-1 5-41 50A-H 25S
PFA-519-* G(T) PFA-520-" GfT) PFA-521-* G(T)
3100 3260 3430
3780 3983 4186
1.288 1 288 1 288
1 15 2406 8 2695 7 1.15 2531 1 2834 8 1 15 2663 0 2982.6 ________ 1
10028 17971 10546 18899 11096 19884
8628.00 18 7060 R10 1-G-20-41 50A-H 25 8872.00 18 7420 R10.1 -G-20-41 50A-H 25
9160.00 18 7780 R10 1-G-20-4150A-H 25
The net t = 8=R rotingt ihown ore bosed on piping and pick-up allowance! lilted above. American-Standard ihould be coniulted before
selecting a boiler for installations having unusual piping and pick-up requirements.
'Substitute letter "S" for tteom, "W" for water. START-UP AND ONE YEAR'S SERVICE. INCLUDED IN TRADE PRICE OF CAS UNIT :l) Suffi* (T) denotes boiler with openings in center section for tankless heoters when specked For Built-in Water Heaters, see page 27.
Height 3 feet above highesl pari of roof.
Available as assembled unit or assembled sections--see cage 2~
Standard Equipment--All Boilers Steam: PA404A Pressuretrol, ASME safety valve, steam
gauge, gauge glass with trimmings, drain valve. Water: L4006A Aquastat, ASME relief valve, pressure and
temperature gauge, drain valve.
Standard Equipment--Gat Fired Flange mounted gas burner. Standard burner controls meet latest UL requirements. Dual automatic gas valves for add ed reliability. Gas-electric ignition. Electronic program ming controls and components are factory wired in a con trol cabinet on the burner. Includes R4795 control on 4 thru 10 section; R4150A control on 11 thru 21 section; proven pilot. Standard burners equipped to operate with 1,000 Btu, 0.6 specific gravity natural gas.
Ordering Example*: PFA-5 baiter-burner unit for iteom with stoodord equipment. 1--PFA-514-SC boiler-burner unit PFA-5 boiler-burner unit for water with optional equipment. 1-PFA-511-WG(T) witK jacket extension; 4 No. 545 tanklen heater*.
Specify gas pressure ovoiloble ot gas troin inWt.
O) Surcharge for Start-Up and Service west of Mississippi River. Contact American*Standard for details.
Optional Equipment
PFA-5 units for Factory Mutual and Factory Insurance Association Diinimiim requirements at the following added charges:
boiler iize
F.M.
9* fired -----
F.I.A.
PFA-504-510
$682.00
S 827.00
PFA-511-515 PFA-516--521
811.00 811.00
1074.00 1074.00
For prices of gas burners for use with other than 1000 Btu, 0.6 specific gravity natural gas, or at gas pressures above or below pressures shown in current literature, consult your American Standard District Office.
High Risk F.M. or F.I.A. requirements......
Hi-Lo Fire Control .................................... Modulating Fire Control ................................
Price
Alarm System pre-wired and mounted on
on
control cabinet.................................................
Optional Combustion Controls ....................... Application
Controls to meet local requirements ...........
For Additional Optional Equipment and assembly ar rangements, see page 27.
Ges end G*s-0<l Burners nol stocked si Bond Plan! 3 to 4 weeks lead lime for shipment of Standard Equipped Burners after receipt of order at Hydronic Order Service Center.
Standard Motor Voltages
unit numbtr
go* bv'Mti
PF A-504-511 PFA-512-521
115-60-1 230-60-3
Other optional motor voltages--Price on Application.
HH-75-1 W See page 48
Page 28 Fpf compieie specification* refer to Technical Ca's'og Bui'eim Form No 9115-2 (Rev 3 6'72)
07636
PFA-5 PRESSURE FIRED BOILER-BURNER UNITS
Jacketed--forced draft with combination pas/oil burner. 50 lbs. water working pressure--15 lbs. steam working pressure. Equipped for tankless heaters.
GAS--UGWT Ott BOILER-BURNEH UNITS
STEAM AND WATER
pretture fired beiler-bwmev
**'
gag lgh< <!
grtil a|*
IBburInSer I copoclty
eutput
Mbh input
Mb*
piping and
teier
steam water
net s|s| rating Mbfc e. ft.
iteom water team
net rating Ml. ft. water
^ Trade
Frit# with Standard
equipment
gat-- etl
vent
site
rfiam. in.
Imate hipping wlghf
burner medtl tuaplied with tandord equipment go -- erl
PFA-S04-* GO(T) PFA-50S-* 60(T) PFA-506-* GO(T)
PFA-507-* GO(T) PFA-508-* GO(T) PFA-509-* GO(T)
PFA-510-* GO(T) PFA-511-* GO(T) PFA-512-* GO(T)
PFA-513-* GO(T) PFA-S14-* GO(T) PFA-515-* GO(T)
PFA-516-* GO(T) PFA-S17-* GO(T) PFA-518-* GO(T)
PFA-519-* GO(T) PFA-520-* GO(T) PFA-521-* GO(T)
620 . 763 786 966 950 1169
1116 1372 1282 1568 1446 1771
1612 1974 1776 2177 1944 2373
2108 2576 2272 2779 2440 2975
2604 3178 2768 3381 2936 3584
3100 3780 3260 3983 3430 4186
1.333 1.333 1.333
1.333 1.330 1.315
1.302 1.292 1.288
1.288 1 288 1 288
1 288 1 288 1.288
1 288 1.288 1.288
1.15 1.15 1 15
465 1 589.6 712.7
539.1 683.5 826.1
1.15 837.2 970.4 1.15 963.9 11 14 8 1.15 1099.6 1257.4
1.15 1238.1 1401.7 1.15 1374 6 1544.3 1.15 1509.3 1690.4
1.15 1636.6 1833 0 1.15 1764 0 1975.7 1 15 1894 4 2121.7
1 15 2021.7 2264 3 1.15 2149.1 2407.0 1.15 2279 5 2553.0
1.15 2406 8 2695 7 1.15 2531.1 2834 8 1.15 2663 0 2982 6
1938 2457 2969
3488 4016 4582
5159 5728 6289
6819 7350 7893
8424 8954 9498
10028 10546 11096
3594 4557 5507
6469 7432 8383
9345 10295 11269
12220 13171 14145
1S09S 16047 17020
17971 18899 19884
$3636.00 3959.00 4309.00
4679.00 S082.00 5310.00
5961.00 6443.00 6927.00
7243.00 7492.00 7714.00
8190.00 8418.00 8768.00
9188.00 9548.00 9836.00
10 10 10
10 10 14
14 14 14
14 14 14
18 18 18
18 18 18
1840 2210 2520
R6.2-GO-03-R4795-B.12S-F4B R6.2-GO-03-R4795-B.12S-F4B R6.2-GO-03-R4795-B.12-F4B
2880 3190 3550
R8-GO-05-R4795-8.12-F3 R8-GO-05-R4795-8.15-F3 R8-GO-OS-R4795-B.1S-F3
3935 4285 4645
R8.1-GO-05-R4795-B 20-F3 R8.2GO-07.4150A-H.20.F4H
R8.3-GO-10-4150AH.20-F4H
4955 5315 5675
R10 9-GO-10-4150A-H 20-F4H R10 9-GO-10-41 50A-H.2Q-F4H R10.9-GO-10-41 50A-H 20-F4H
5985 6345 6750
R10-GO-15-4150A-H.25SF4H R10-GO-15-4150A-H 25S-F4H R 10.1 -GO-20-4150A-H.25S-F4H
7060 7420
7780
R10.1-GO-20-4150AH.25-F4H R10.1-GO-30-4150A H 25-F4H R 10.1-GO-3O-4150A-H 25-F4H
The nqt I r I = K ratings shown ore based on piping and pick-up allowances listed above. American-Standard should be consulted before selecting a boiler for installations having unusual piping and pick-up requirements
Substitute letter "S" for steam. "W" for water. START-UP AND ONE YEAR'S SERVICE. INCLUDED IN TRADE PRICE OF GAS-Oll UNIT (I) Suffix (T) denotes boiler with openings in center section for tonkless heaters when specified For Built-in Water Heaters, see page 27.
Height 3 feet above highest port of roof.
Available as assembled unit or assembled sections--see page 27
Standard Equipment--All Boilers
Steam: PA404A Pressuretrol, ASME safety valve, steam gauge, gauge glass with trimmings, drain valve.
Water : L4006A Aquastat, ASME relief valve, pressure and temperature gauge, drain valve.
Standard Equipment--Gas-Light Oil Fired
Flange mounted combination gas-oil burner. Standard burner controls meet latest UL requirements. Manually operated fuel switch for dual fuel change-over. Dual auto matic gas valves for added reliability. Gas-electric ignition.
Elect:omc programming controls and components are fac tory wired in a control cabinet on the burner. Includes R4795 control on 4 thru 10 section; R4150A control on 11 thru 21 section; proven pilot. Standard burner equipped to operate on No. 1 or No. 2 fuel oil and 1,000 Btu, 0.6 specific gravity natural gas.
^hNoziie sues, gpn, furnished with combination gas-light oil burners are as follows: (nozziecaoaatyis dependent on oil pressure.)
unit ne. gph. type
unit ne. gph. type
unit no gph. Type
PFA-504 1 4 00 90H PFA-505 1 5 00 90H PFA-506 1 6 50 90H PFA-507 2 4.00 90S PF A-508 2 4,00 90S PFA-509 2 5.00 90S
PFA S10 2 5 00 90S PFA-511 2 5.50 90S PFA-512 2 6.00 90S PFA-513 2 7.00 60S PFA-514 2 7.00 60S PFA-515 2 7.00 60S
PFA-516 2 7 00 60S PFA-51 7 2 8 00 60S PFA-518 2 8.00 60S PFA-519 2 8 00 60S PFA-520 2 8 50 60S PFA-521 2 9 00 60S
Optional Equipment
PFA-5 units for Factory Mutual and Factory Insurance Association minimum requirements at the following add ed charges:
get-ail fired!
boiler site
F.M.
F.I.A.
Standard Motor Voltages
unit number
pot-nil burner*
PFA-504--5r0
115-60-1
PFA-511
230-60-1
PFA 512-521
230-60-3
Other optional motor voltages--Price on Application.
(11 Surcharge far Start-Up and Service we* of Mississippi River. Contact American-Standard far details.
Ordering Examples; PFA-5 boiler-burner unit for steam with standard equipment. 1--PFA-5IA-SGO boiler-burner unit. PFA-5 boiler-burner unit for woter with optional equipment. 1 -- PFA-511 -WGO(T) with jacket extension; 4 No. 548 tonkless heaters.
Specify gas pressure available at got train inlet.
PFA-504--510 PFA-511-515 PFA-516-52!
$ 824.00 1059.00 1054.00
$ 899.00 1227.00 1239.00
Automatic Fuel Changeover Trade PriceVT.............................................................................. 9237.00
For prices of gas-oil burners for use with other than 1000 Btu, 0.6 specific gravity natural gas, or at gas pressures above or below pressures shown in current literature, consult your American Standard District Office. High Risk F.M. or F.I.A. requirements......
Hi-Lo Fire Control .............................................
Modulating Fire Control......................................
Price
Alarm "System pre-wired and mounted on control cabinet.................................................
Optional Combustion Controls........................
on Application
Controls to meet local requirements ...........
Additional optional equipment and assembly arrangements --see page 27.
Gas and Gaa-Oil Bumars not Blocked at Bond Plant 3 to 4 weeks lead time for shioment of Standard Equipped Burners alter receipt of order ar Hydromc Order Service Center.
W See page 48
Page 29
For complete specifications reer 10 Technical Caialog BuMeim Form No. 911S-2 (Rev. 3 6/72)
HH-75-1
07637
OPTIONS--A-5/FRA-S/PFA-5 TANKLESS WATER HEATERS LOW WATER CUT-OFFS
fail AMERICAN LS STANDARD
HYDRONIC HEATINO
TANKLESS WATER HEATERS FOR A-5, FRA-5 AND PFA-5
Tankless water heaters are available in any quantity at the following Trade Prices:
Uetar iMPUf uwd with
pres. drop at ratad flow Trad# PrUe --d>
530 A-5, FR-A-5 548 PFA-5
15 psi 16 psi
$54.00 89.55.
PFA-5 units with tankless water heaters require additional controls at current prices as follows:
STEAM: L4006A Aquastat operating control.
Trade Price
$16.90
WATER: L6006A Aquastat operating and circulator
control.
Trade price
$17.95
Cover plate required to close unused water heater open ings will be furnished if specified on order for "T" type boiler. Trade Price each .............................................................
PFA-5, A-5. FRA-5........... Trsde Price Met......................$5.45
Factory assembled copper pipe manifold for parallel hook up of multiple heaters are available as follows:
tw A-J, .*.J
2 Hsstsr.................................................................. $11.05 3 Hester................................................................... 16.00 4 Hseter................................................................... 20.50
A*S
MAS
Uttar
A-5 or FR-A-S04-T A-5 or FR-A-505-T thru 507-T A-5 or FR-A-508-T thru S09-T A-5 or FR-A-510-T thru S11-T
IMS. M.
8p8Wlfi
2 3
4
5
PFA-J
Uttar
PFA-504-T PFA-505-T thru 506-T PFA-507-T thru 508-T PFA-509-T thru 511-T
mai. m.
i
2 3
4
PfA-S WtUr
PFA-512-T thru 514-T PFA-515-T thru 517-T PFA-518-T thru 519-T PFA-520-T thru 521-T
SMI. M. <
5 6 7 8
The following table shows ratings attained if more than one heater is connected in parallel:
lonklcat
n*. SX
SmN4 H*. Ml
1*0 *1 Uartm
*rotine gptn.
Uttar wwwUr
m* ef taatin
A-5 or FR-A-5-T all sizes
A-5 or F R-A-5-T ail sizes
A-5 or FRA-506-T thru 511-T A-5 or FR-A-508-T thru 511*T A-5 or FR-A-510-T thru 511-T
1
2 3 4 5
4 PFA-5-T all sizes 7 PF A-505-T thru 506-T 10 PFA-507-T thru 508-T 13 PFA-509-T thru 511-T 16 PFA-S12-T thru 514-T
PFA-515-T thru 517-T PFA-518-T thru 519-T
PF A-520-T thru 521-T
1
2 3 4
5 6 7
8
raiW
40*P 140*F with J0O*F U'tar >o'i'
fottaf ee*"-
8 16 24 32 40 48 56 64
McDonnell & miller low water cut-offs
"W TrA Srlu
STEAM: No. 369 Low Water Cut-off for A-5. FR-A-6, PFA-6 ..................................................$ 34.30 No. 47-2 Feeder and Cut-off for A-5, FR-A-5, PFA-604 thru PFA-509 ............... 98.00 No. 51-2 Feeder and Cut-off for PFA-510 thru PFA-621 .......................................... 127.05
WATER--60 PSI: No. 63 Low Water Cut-off for A-5, FR-A-6 and PFA-5 ........................ 57.50 WATER--80 PSI: No. 150 Low Water Cut-off for PFA-5 ........................................................ 85.90
HH-75-1 W See page 48
Page 30
07638
AMERICAN kSJ STANDARD
HYDRONIC HEATINO
OIL FIRED BOILER-BURNER UNIT WATER AND STEAM
FR-A-5 FLAME RETENTION BOILER-BURNER UNITS
Jacketed--50 lbs. water working pressure--15 lbs. steam working pressure. Sections precision ground--with or without tankless heaters. 115 volt, 60 cycle power supply.
WATER
boiler-burner untt number
.I*s*l?a*R output
Ubh
burner capacity
fph
net l*B=ft retlng
Ubh
net retlng sq- ft. water
Trede Price with tandsrd equipment
For BuitMn Water Heaters, Staam and Water Boilers, see page 27.
appro*. hipping weight
chimney else
. A tpf. . "
e
;
Bfl B1
HI
[HKb
K B
Hr ^9
FR-A-504-WB(T) FR-A-505-WB(T) FRA-506-WBO)
FR-A-507-WBfT) FR-A-508-WB(T) FR-A-509-WB(T)
FR-A-510-WBfT) FR-A-5ll-WB(Tj
384 472 560
648 736 824
912 1000
3.55 4.30 5.10
5.90 6.70 7.45
8.25 9.05
333.9 410.4 487.0
563.5 640.0 716.5
793.0 869.6
2226 2736 3246
3756 4266 4776
5286 5797
STEAM
boHer-bumer unit number
FR-A-504-SB(T) FR-A-505-S8(T) FRA-506-SBCT) FR-A-507-SB(T) FRA-508-SBfn FR-A-509-SB(T) FR-A-510-SB(T) FR-A-511SBCT)
crocs IsBaft output
Ubh
burner capacity
gph
384 472 560
648 736 824
912 1000
3.55 4.30 5.10
5.90 6.70 7.45
8.25 9.05
net t = B:eft rating
Ubh
ftq. ft. staam
288.1 354.1 420.1
486.1 552.1 618.2
684.2 750.2
1200 1475 1750
2025 2301 2576
2851 3126
$1394.00 1542.00 1798.00
1963.00 2288.00 2453.00
2630.00 2805.00
1576 1827 2110
2367 2626 2890
3144 3392
12 x 12 x 15 12 x 12 x 20 12 x 12 x 20
12 x 16*20 12 x 16x20 12 x 16x20
16 x 16 x 20 16 x 16x20
Trade Pries with standard equipment
1394.00 1542.00 1798.00
1963.00 2288.00 2453.00
2630.00 2805.00
approx. shipping weight
chimney Ue
1577 1828 2112
2369 2628 2892
3147 3395
12 x 12 x 15 12 x 12 x 20 12 x 12 x 20
12 x 16 x 20 12 x 16 x 20 12 x 16 x 20
16 x 16x20 16 x 16 x 20
*haGO nozzle sues con furnished 'or Above units FRa-504. 3 5. 80" P. FflA-505 4, 60" P; FRA-506, 5 60* P FRA-507 6 60 P, FRA-5C8 6 5 4$ P FRA-509. 7 5. 45* P. FRA-S10 8 45* P. FRA-5U. 9. *5* P Suffi* "T' denotes unit with openings in center sections ter tankless heaters. Start-up end one year service available. Price on application.
Standard equipment Flange mounted oil burner with 2*stage fuel unit; delayed oil valve on model LC-534-A and instantaneous on HC-34A oil burners; light sensing pnmaiy control.
boilerbumer untt number ell burner
FRA-504 thru FRA-507 LC-534A-D 41752 FRA-S08 thru FRA-511 HC-34-A-D 41751
Draft regulator Drain valve
Water No. 3 control set:
T822D thermostat L4080B Aquastat limit control Nozzle(s)
ASME relief valve Pressure and temperature gauge
Steam: No. 1 control set:
T822D thermostat PA404A Pressuretrol Nozzle(s)
ASM_E safety valve
Steam gauge Gauge glass with trimmings
Optional Equipment
80 lbs. water test. Trade Price per section ...............111.00 Jacket extension. Trade Price ........................................ $56.00
Cover plate required to close unused water heater openings
furnished if specified on order for "T" type boiler. Trade Price each ...............................................................................$5.45
For Factory Mutual Approval and Massachusetts code requirements, special electronic flame safeguard controls are available, with R4150A Protectorelay, C-7013A photo cell, and safety oil valve.
Control sets other than those included in Trade Price of FR-A-5 boiler-burner units will be furnished on order at the following added charges:
Control S*t
eddwd charge
Steam control set No. 2
$16.90
oil heating unit
FRA-504 thru FRA-507
FRA-508 thru FRA-511
bumar model
LC-534A-D 41431 HC-34-A-D 41431
^ added Trade Price charge
Water control set No. 5 Water control set No. 5-Z
25.85 30.05
$282.00
{Add-on zone. Use only with No. 5 Control Set. The No. 5-Z control set ter circular zoning on units with tankles* heaters.)
Ordering Examples:
282.00 1. Boiler-burner unit with standard equipment: 1 FR-A 506-SB oil heating unit. 2. Boiler-burner unit for steam with optional equipment: 1 FRA-509-SB-T with No. 2
control set: 3 No. 530 tankless heaters; 1 3-heeler manifold.
See page 48
Page 31
For complete ipecificaiiori* refer lo Technical Cm*'TM-.
Form No 768-? (Rev 7/73)
HH-75-1
07639
oil fired boilers
WATER AND STEAM
AMERICAN baSTANDARD
HTDRONIC HEATING
A-5 OIL FIRED BOILERS
Jacketed--50 lbs. water working pressure--15 lbs. steam working pressure. Sections with or without tankless heater.
boiler number
greet
IsSsft output
Mb*
burner eepeefty
CP*
net tsBsR rating
Mb*
net rating 9* water
Trade Prteo
apprwz. ftMppfetf weight
For Built-in Water Heaters, Steam and Water Boilers, see page 27.
A-504-W(T) A-505-W(T) A-506-WfO
A-507-Wm A-508-WfT) A-509-W(T)
A-5I0-W(T) A-511-W(T)
261 346 426
508 588 668
748 830
2.55 3.30 4.00
4.75 5.55 6.30
7.00 7.65
227.0 300.9 370.4
441.7 511.3 580.9
650.4 721.7
1513 2006 2469
2944 3408 3872
4336 4811
*1002.00 1151.00 1311.00
1477.00 1636.00 1794.00
1959.00 2129.00
1518 1770 2025
2282 2539 2794
3050 3298
chimney Jxe
8x 12 x 15 8 x 12x20 12 x 12x20 12 x 12 x 20 12 x 16x25 12 x 16x25 12 x 16 x 25 16 x 16 x 30
STEAM
boiler number
A-504-S(T) A-505-S(T) A-506-S(T) A-507-S(T) A-508-SfT) A-509-Sfn
A-510S(T) A-511-SCO
gross !=B=R output
Mbh
261 346 426
508 588 668
748 830
IsBsR burner capacity
CP*
2.55 3.30 4.00
4.75 5.55 6.30
7.00 7.65
net 1 = # = R rating
Mbh
sq ft steam
195.8 259.6 319.6
816 1082 1332
381.1 441.1
501.1
1588 1838 2088
561.1 622.7
2338 2594
Trade Price
$1002.00 1151.00 1311.00
1477.00 1636.00 1794.00
1959.00 2129.00
approa. shipping weight
1519 1771 2027
2284 2541 2796
3052 3300
chimney atxe
8 x 12 x 15 8 x 12 x 20 12 x 12 x 20
12 x 12 x 20 12 x 16 x 25 12 x 16 x 25
12 x 16 x 25 16 x 16 x 30
Suffii "T" denotes boiler with openings In center sections for tankless halters.
Standard equipment:
Optional equipment:
Water. ASME relief valve
Pressure and temperature gauge Drain valve
Cover plate required to close unused water heatei openings furnished if specified on order for "T" type boiler. Trade Price each .................................................................................. *5.45
Steam: ASME safety valve Steam gauge Gauge glass with trimmings Drain valve
Ordering Examplts: 1. Boiler only for steam with standard equipment: 1 A 507 S boiler. 2. Bode' only for water with optional equipment: 1 A 506 W boiler with jacket extension
Zone valve packages are available for water boilers. For details and prices, see page 33.
Oil Burners available on special order .............................................. Price on Application
Jacket extension: Trade Price ...........................................*56.00 80 lbs. water test. Trade Price per section ..................*11.00
For complete specifications refer to Technical Catalog Bulletin Form No. 758-2 (Rev 2 5/71)
A-5 OPTIONAL EQUIPMENT
HEAT LIB-O-RATOR MOLDED REFRACTORY COMBUSTION CHAMBERS
unit number
A-504 A-505 A 506 A-507. A-508 A-509. A-510, A-511
Heat Ub-O-Rator model No. included
14-A 15-A 15-AA 16-A 17-A
maximum firing rate gallons per hour
2.55 3.30 4.00 5.55 7.65
Trade Price
$51.00 51.00 65.00 65.00 74.00
approx. shipping weight
158 163 176 180 200
HH-75-1 See page 4fl
Page 32
07640
, -- I AMERICAN kSJ STANDARD
HYDRONIC HIATI NO
OIL BURNERS OPTIONAL EQUIPMENT
DH OIL BURNERS The DH burner. 115 volt, 60 cycle power supply.
capacity
ei. pwr iawr
eir tvbe dime. UnpHi
Trade Price vlrti oeule
Include* factory tottolWd cad cell
arllfc N. 1 r M. } centre! ref and primary central
with primacy central md
hassle
lets end cell
app. d*lp. weifM
#wi*
centre! at
DH-4-F
DH-5-F DH-5 DH-8 DH-15 DH-23
.55-3.00 .55-3.00 .55 - 3.00 .65-3.00 .65 - 3.00 .65 - 3.00
4 4 4 4
4 4
4 sling
5 sling 5 sling 8 (pedestal)
15 < or ? 23 1 flange !
$208.00 208.00 208.00 218.00 218.00 218.00
$186.00 186.00 186.00 191.00
191.00 191.00
$148.15 148.15 148.15 153.70 153.70 153.70
55 55
55 60 64
68
Mttr-biimcr unit oil burmr contrail
Disc-turbulator combina tions for DH oil burner are
as follows:
Selection of nozzle:
V-3M boiler unit OH-5
(Primary control, controls. Cad cell factory installed.
I. Draft regulator.
Note: For V-3M units pressure ring is packed with DH-5 burner.
firing rate no. fph
Bring rate tph
nozzle eprpy
.55 to 1.25 60*-70* hollow
i .65-1.10
or solid
2 .90-1.75
3 1.80-2.50 above 1.25 60*-70* solid 4 2.35-3.00
Oil burners listed in this Price Book are approved by the National Board of Fire Underwriters, comply with U. S.
Government Commercial Standard CS-75, and are for use with No. 1 or No. 2 fueloil.
The correct disc-turbulator combination is furnished in stalled in the DH burner for nozzle site specified on order.
Two-stage fuel unit available for DH oil burners.
Capacities of oil burners using No. 1 or No. 2 fueloil are for installations at sea level and at elevations up to 1,000 feet. Reduce by 47c for each additional 1,000 feet above sea level.
Trade Price ......................................................................... $6.30
Controls and control sets are shown on page 31. Ordering examples:
1. Oil Burner 1 OH-5 oil burner with No. 5 control set and 1.25 gpii 70"' solid nozzle for V3M138WT boiler burner unit.
2. Oil Burner 1 OH-23 oil burner with No. 3 control set. 1 50 gph 60* solid nottle, with pedestal.
for complete specifications refer to Tecrmcai Catalog Sclletirv Form No. 60-2 (Rev.)
HYDRONIC ZONE VALVE PACKAGES
No. Z-2 Package for 2 Zones
No. Z-3 Package for 3 Zones
No. Z-4 Package for 4 Zones
1 T822D thermostat
2 T822D thermostats
3 T822D thermostats
2 V8043F
lone valves soldered to 3 V8043F \" zone valves soldered to 4 V8043F 44" zone valves soldered to
manifold
manifold
manifold
Less transformer
Less transformer
With transformer
^ Trade Price............................... $106.00 Trade Price ........
................. $140.00 ^Trade Price ................................ $190.00
Each zone valve package consists of 2, 3, or 4 Honeywell %4" zone valves soldered to manifold with 114" NPT inlet, wired to low voltage leads for transformer and all (auxiliary) switches wired in parallel with a pre-wired harness. On-the-job wiring requires 115 volt line to
transformer, low voltage connections to circulator con trol, and low voltage wiring to each thermostat.
If V6" system piping is used, a % x 54 nominal copper to copper flush bushing can be soldered to any or all of the % " zone valves on the manifold. Flush bushing not furnished.
One less thermostat is furnished than the number of zone valves per package. An additional thermostat is required when zone valve package is used on boiler furnished less thermostat.
40 VA transformer is not required when control L8148G or R8226B with power for 3 zone valves, is supplied with boiler.
If 40 VA transformer is wanted with No. Z-2 or No. Z-3 Packages, specify on order and add to the above Zone Valve Pack age prices....................................................................................................................................................................T Trade Price each $4.00
Honeywell V8043F Zone Valve sold separately .
T Trade Price each $25.00
NT See page 48
For complete specification* refer to Technical Catalog Bulletin Form No. 2S66>2 (1/69)
Page 33
HH-75-1
07641
CONTROL SETS, CONTROLS
fS\ AMERICAN
SJSTANDARD
HYDRONIC HEATING
CONTROL SETS FOR BOILER-BURNER UNITS
Control tet
no. 1 steam
no. 2 steam
for boiler without domestic hot water
boiler with year-round domestic hot water, tankless heater
no. 3 gravity water
no. 4 forced water
briler without domestic hot water, immersion control
boiler without domestic hot water
no. 5
V-3, V-3M, A-5, FR-A-5 units only with
forced water year-round domestic hot water
no. 5-Z forced water
V-3, V-3M, A-5, FR-A-5 units only, fl no. 5-Z set is required for each zone in addition to the first zone which is controlled by the no. 5 control set or equivalent.)
control number
T822D PA404A
T822D PA404A L4006A
T822D L4080B
T8220 L4081B
T822D L8124C
T822D R845A
contents of control tot
description
Thermostat Pressuretrol
Thermostat Pressuretrol Aquastat operating control
Thermostat Aquastat limit control
Thermostat Aquastat limit and circulator control
Thermostat Aquastat limit, reverse and operating control, circulator relay
Thermostat Relay
add to Trade Price of oil burner with bade control set
$16.90
$12.15 $25.85 $30.05
number T822D TS822A T882A L4006A L4006E L4081B L4080D L4080B L6006A
L8124C L81248
L8124E
L404C L604A LSI48E
L8148G
description
thermostat, adjustable heater 0.18 to 0.8 amp. thermostat, millivolt
thermostat, electric clock Aquastat operating control Aquastat operating control; locks out on high limit setting; manual reset
Aquastat limit and circulator control Aouastat limit control Aquastat limit control Aquastat operating and circulator control Aquastat limit, reverse and operating control, circulator relay;
line voltage burner control, horizontal case for gas or oil
manual-auto switch, vertical case
low voltage burner circuit for gas, vertical case. Power for 2 zone valves
Aquastat-relay combination, high limit and line voltage circulator control. horizontal case:
Pressuretrol w/man. reset SPDT operating controller low voltage burner control for gas. Power for 2 zone valves.
millivolt burner control for gas. Power for 3 zone valves.
CONTROLS
^ Trad* Price
number
$ 7.70
7.70 37.20 16.90 19.40
PA404A RA89A RA832A R845A
R8226B R8182D
25.15 13.00 13.00
17,95
R8182E
aa.as 35.30 38.15
34.20 33.95 24.40 26.65
R8182F R8184G 120320
description
^ Trade Price
Pressuretrol relay, SPST relay, DPST relay, DPST
Transformer and circulator relay
Aquastat-relay combination, high and low limit; providing room thermostat control of circulator: light sensing primary control, less cad cell; safety switch timing 70 seconds. For use with tankless.
Aquastat combination, high limit; providing room thermostat control of circulator: light sensing primary control. less cad cell; safety switch timing 70 seconds. For use less tankless.
Aquastat combination, high limit: providing room thermostat control of burner and boiler water temperature control of circulator; light sensing primary control, less cad cell; safety switch timing 70 seconds. For use less tankless.
light sensing primary control, less cad cell:
control number
safety-twitch timing-tecond eph
R8184G1005
60
RB184G1021
30
R8184G1013
is
cadmium sulfide cell only
3 3-7 7-20
$19.35 17.75 22.35 22.35 13.00
58.20
56.50
50.55
30.55 34.45 34.45
2.40
To substitute T882A* for T822D Thermostat; specify on order control set with suffix "B" and add difference to trade price from above.
___________________________ Accessories ind controls included In tills price boo* ire tor use In conjunction wltn American.SUndsrd products.
HH-75-1
Page 34
W See page 48
07642
AMERICAN LaSTANDARD
HYDRONIC HEATING
hydronic assembling
TOOLS
PACKAGED HYDRAULIC ASSEMBLING TOOL: All necessary parts to assemble any American-Standard sectional boiler, except long tie rods, shipped in one packing case; the long tie rods are furnished in their own wooden box. Total weight approximately 250 lbs.
W Trade Priea - *700.00
HEATRIM COPPER TUBE BENDING TOOL: Designed to bend riser tube connections for Model R Heatvim baseboard panels. Complete instructions for tool use included.
W Trade Priea each - *18.50
HEATRIM RISER HOLE TEMPLATE: This tool accurately and quickly lo cates riser hole locations for Model R Heatrim panels. Consists of template (two pieces). 8 ft. steel tape and com plete instructions.
Trade Price each -- *3.50
ALUMINUM NIPPLE-SETTING-HAMMER: --consists of a 2 lb. 1'h" diameter aluminum head and a 14" long hard wood handle. The aluminum head will not damage the nipple edges and per mits the heavy blows necessary to set nipples to the recommended depth quickly.
yf Trade Price each -- $5.80
SECTION BUMPING BLOCK: -- made of a 6" x 6" x 18" hardwood block with a convenient steel handle for swinging the tool. Its purpose is to bump a section onto the pre-set nipples of the previous section to the recommended depth, prior to pulling the section up.
yr Trade Price each - *17.05
So page 48
Page 35
HH-75-)
07643
PACKAGED BOILERS ELECTRIC WATER
.--^AMERICAN STANDARD
HYDRONIC HEATING
PACKAGED ELECTRO-HYDRONIC BOILERS
ELECTRA &
ELECTRA II
ELECTRIC KNTMl HEATING BOILER
WITH MTICML UMTT COMTItX
E 38076__________ No. ooo ooo ^
Pre-wired for 240 volt, three wire, 60 cycle, single phase service.
Designed and equipped with con trols for forced circulation.
Tested and equipped for 30 lbs. water working pressure.
ELECTRA--WATER
packaged boiler number
number of
elements
output watte
output btuh
amps 9 240 volts
T Trsdo Pries with stsndsrd
equipment
appros. shipping weight
EP-34
EP-51 - EP-68
EP-82
2
10,000
34,130
41.7
$541.00
98
3
15,000
51,195
62.4
559.00
99
4
20,000
68,260
83.2
582.00
100
5
24.000
81,912
100.0
X 603.00
102
Output ratings based on 240 volts. Reduce output ratings for other voltages as follows: 230 volts, 8%; 220 volts, 16% ; 208 volts, 25%.
ELECTRA II--WATER
packaged unit
number
number of
elements
EP-7
EP-10 EP-14 EP-17 EP-20
i i i 1 i
output wsttt
2,000 3,000 4,000 5.000 6.000
output btuh
6,626 10,236 13,648 17,060 20,472
amps 240 volts
8.34 12.50 16.65 20.81 25.00
Trade Price with standard
equipment
$270.00 270.00 270.00 270.00 270.00
approx. shipping weight
49 49 49 49 49
Standard Equipment
ELECTRA
T822D thermostat AT72D low voltage transformer - R8154 sequencing control
L4008J adjustable immersion type limit control
. Allen-Bradley 836CP11-HKAZS high pressure switch with EP-68 and EP-82 only
J. W. Hobbs M4440 low pressure switch
1 %" circulator
Expansion tank (diaphragm type) Automatic air vent
ASME relief valve Pressure and temperature gauge Drain valve
ELECTRA Optional Equipment
Sequencer Package: Available for field installation on EP-68 and EP-82
Boilers in addition to regularly furnished sequencing relay. Package con
tains all necessary equipment and instructions for the installation of one
(EP-68) or two (EP-82) 24A11-4 Sequencer(s) provides a 45 second
current delay between the third and fourth elements of the EP-68 or be
tween the third, fourth and fifth elements of the EP-82. Standard R8154
relay provides a l/120th of a second (H cycle) current delay between each
element.
Sequencer PtckM*
T TraOa Prfct
EP-68 EP-82
$15.55 30.05
Note: Zone valve packages are available for water boilers. For details and prices, see page 33.
ELECTRA II
T822D thermostat Circulator with piping Drain valve ASME relief valve Pressure and temperature gauge Expansion tank (diaphram type) L4080D immersion limit control J. W. Hobbs M4440 low pressure switch Automatic air vent
HH-75-1 See page 48
Page 36
For complete specification* refer to Technical Catalog Bulletin Form No. 2126*2 (Rev 3/70). 315-2 (Rev 4 9/70)
07644
1 AMERICAN kSi STANDARD
HYDRONIC HiATINO
HEATRIM PANELS
MODEL R HEATRIM PANELS
SEE CURRENT LITERATURE FOR APPROVED l==R HOT WATER RATINGS
iFnr
Mod"! P.-75C sr.d V"
n-300 ranois)
DESCRIPTION
ordering numbr
paekiftd par
MODEL R-750-A COMPLETE ASSEMBLED UNITS (Single Pack)
includes 1 each of front and back panel, element, damper, support brackets, slide cradles and 1 set joining pieces. (See Note #1) Finished with white prime paint. All factory assembled.
Box Color Coded-Red
Orderitf Example:
1-box R-750-A4
R-750A2 R-750 A3 R-750-A4 R-750A5 R-750A6 R-750-A7 R-750A8
per lineal foot 2 ft. length 3 ft. length 4 ft. length 5 ft. length 6 ft. length 7 ft. length 8 ft. length
MODEL R-500-A COMPLETE ASSEMBLED UNITS (Single Pack)
includes 1 each of front and back panel, *4" element, damper, support brackets, slide cradles and 1 set joining pieces. (See Note M1) Finished with white prime paint. All factory assembled.
Box Color Coded-Green
Ordering Example:
1-box R-500-A3
R 500-A2 R-500 A3 R-500 A4 R-500A5 R-500A6 R-500 A7 R-500 A8
per lineal foot
2 ft. length 3 ft. length 4 ft. length 5 ft. length 6 ft. length 7 ft. length 8 ft. length
MODEL R ENCLOSURE ONLYASSEMBLED (Single Pack)
includes 1 each of front and back panel, damper, support brackets, slide cradles and 1 set joining pieces. (See Note #1) Finished with white prime paint. All factory assembled.
Box Color Coded-Black
Orderieg Example:
1-box R-3-A
R-3A R-4-A R-5-A R-6A R-7-A R-8-A R-10-A R12-A
per lineal foot
3 ft. length 4 ft. length 5 ft. length 6 ft. length 7 ft. length 8 ft. length 10 ft. length 12 ft. length
Trad*
Met
approx.
hipplntf waif
$ 2.65
$ 5.30 7.95
10.60 13.25 15.90 18.55 21.20
5 7 9 12 13 16 18
t 2.52 $ 5.04
7.56 10.08 12.60 15.12 17.64 20.16
5 7 9 11 14 15 18
$ 1.30
$ 3.90 5.20 6.50 7.80 9.10
10.40 13.00 15.60
6 8 10 11 13 IS 17 19
MODEL R ENCLOSURES ONLYUNASSEMBLED (Bulk Pack)
includes 3 sets of front and back panels, dampers with clips, support orackets, slide cradles and 2 sets of joining pieces. (See Note #1) Finished with white prime paint. Unassembled.
Box Color Coded--Blue
Orperiag Exempli:
1-box R-5-B
R3B R4-B R-5-B R-6-B R-7-B R8B R-10B R12-B
For comparative and ettimatmg purposes only.
Not* #1: Joining pieces not included on 2 ft. or 3 ft. sections.
per lineal foot
t 1.17
three 3' lengths thre.: 4' lengths three 5' lengths three'6' lengths three 7' lengths three 8' lengths three 10' lengths three 12' lengths
$10.53 14.04 17.55 21.06 24.57 26.08 35.10 42.12
16 21 26 30 35 40 48 58
So* pago *8
Page 37
For complate specifications refer to Technical Cstslnn .........- -prm No. 114S-2 (Re*. 2/T2)
HH-75-1
07645
HEATRIM ELEMENTS AND ACCESSORIES
^AMERICAN CaSTANDARD
HYDRONIC HEATING
MODEL R HEATRIM ELEMENTS ANn ACCESSORIES
tfymna^r HEXl
DESCRIPTION
E-750 (%" tube) ELEMENTS ONLY (Bulk Pack) Individually boxed and strapped into a bundleof six equal lengths. Ordering Example:
1-bundle *750-3
ordering number
E-750-3 E-750-4 E-750-5 E-750 6 E 750 7 E-750-8
packaged Pr
per lineal foot
Trade Price $ 1.43
approi. hipping weight
six 3' lengths six 4' lengths six 5' lengths six 6' lengths six T lengths six 8' lengths
$25.74 34.32 42.90 51.48 60.06 68.64
9 12 16 18 22 25
E-500 (>.4" tube) ELEMENTS ONLY (Bulk Pack) Individually boxed and strapped into a bundle of six equal lengths.
Ordering Example: 1 --bundle -500-4
-500-3 E-500-4 E-500 5 E-500-6 E-500-7 E-500-8
*per lineal foot $ 1.30
six 3' lengths six 4' lengths six 5' lengths six 6' lengths six 7' lengths six 8` lengths
$23.40 31.20 39.00 46.80 54.60 62.40
8 10 12 16 19 21
ACCESSORIES
End Cap-3" wide-Right Hand End Cap-3" wide-Left Hand Valve Enclosure--4" wide-Right Hand Valve Enclosure--4" wide-Left Hand Valve Enclosure-6" wide-Right Hand Valve Enclosure--6" wide--Left Hand Inside Corner-hinged front and top-90* Inside Corner-back piece-90* Inside Corner-one-piece front and top-135*, 45* Inside Corner-back piece-135*/45* Outside Corner-90* Outside Corner-135*/45* Filler piece set--7" wide Filler piece set-14" wide Wall End Piece--3" wide Return tubing wire hangers Connecting tubing wire hangers Joining piece set-2" wide Extra support brackets with slide cradles and damper
clips Tube bending tool
NOTE: Finished with white prime paint.
RA-ECR-03 box of 10 RA-ECL-03 box of 10 RA-VER-04 box of 10 RA-VEL-04 box of 10 RA-VER-06 box of 10 RA-VEL-06 box of 10 RA-ICF-90 box of 10 RA-ICB-90 box of 10 RA-ICF-45 box of 10 RA-ICB-45 box of 10 RA-OCF-90 box of 10 RA-OCF-45 box of 10 RA-FPS-07 box of 10 RA-FPS-14 box of 5 RA-WEP-03 box of 10 RA-WHR-50 bag of 50 RA WHS-50 bag of 50 RA-J PS-02 box of 20 sets
RASBP-20 box of 20 sets
For compantive and estimating purposes only.
NOTE: Add 25"/ to price when ordering in less than quantities indicated above.
$10.84 10.84 14.67 14.67 22.41 22.41 13.38 4.27 13.34 4.07 16.01 16.66 10.80 8.26 5.60 2.67 2.81 9.41
6.93 18.50
4 4 9 9 10 10 3 4 2 2 5 3 9 9 4 --
5
5
HH-75-1 Sd6 page 48
Page 38
For complete specifications reler to Technical Catalog Bulletin Form No. 1H8-2 (Rev. 2/72)
07646
fail AMERICAN
HYDROme^HIATlNO
HEATRIM PANELS
MODEL SS HEATRIM PANELS, ELEMENTS AND ACCESSORIES
SEE CURRENT LITERATURE FOR APPROVED l=B=R HOT WATER RATINGS (For % " Modal SS75 and 1" Model SS-100 Panels)
DESCRIPTION
MODEL SS-75 COMPLETE UNITS (Dual Pack)
Box includes 2 each of front
and back panel,
element,
damper, support brackets and
slide cradles and 1 joining piece
set (see Note -1). Finished
with off-white prime paint.
Ordering Example
I-box SS-75-4
MODEL SS-100 COMPLETE UNITS (Dual Pack)
Box includes 2 each of front and back panel, 1" element, damper, support brackets and slide cradles and 1 joining piece set (see Note -1). Finished with off-white prime paint.
Ordering Example:
1-box S5-100-5
rearing
SS-752 SS-753 SS-75-4 SS-75-5 SS-75-6 SS-75-7 SS-75-8
SS-100-2 SS-100-3 SS-100-4 SS-100-5 SS-100-6 SS-100-7 SS-100-8
'Trade FHce
par linnl foot $ 4.07
*N^lnf weigh*
Two 2 ft. lengths Two 3 ft. lengths Two 4 ft. lengths Two 5 ft. lengths Two 6 ft. lengths Two 7 ft. lengths Two 8 ft. lengths
$16.28 24.42 32.56 40.70 48.84 56.98 65.12
per lineel foot $ 4.57
14 20 26 33 39 46 52
Two 2 ft. lengths Two 3 ft. lengths Two 4 ft. lengths Two 5 ft. lengths Two 6 ft. lengths Two 7 ft. lengths Two 8 ft. lengths
$16.28 27.42 36.56 45.70 54.84 63.98 73.12
14 20 26 33 39 46 52
MODEL SSI -75 COMPLETE UNITS (Single Pack) Assembled
Box includes 1 each of front
and back panel,
element,
damper, joining piece set (see
Note -1), support brackets and
slide cradles. Finished with off-
white prime paint.
Ordering Example: 1-box SSI -75-7
SSI-75-2 SSI-75-3 SSI-75-4 SSI-75-5 SSI-75-5 SSI-757 SSI-758
per lineel foot $ 4.24
2 ft. length 3 ft. length 4 ft. length 5 ft. length 6 ft. length 7 ft. length 8 ft. length
$ 8.48 12.72 16.96 21.20 25.44 29.68 33.92
7 11 14 18 21 25 28
MODEL SSI-100 COMPLETE UNITS
(Single Pack) Assembled
Box includes 1 each of front and back panel, 1" element, damper, joining piece set (see Note --1), support brackets and slide cradles. Finished with offwhite prime paint.
Ordering Example: 1--box SSI-100-6
SSI-100-2 SSI-100-3 SSI-100-4 SSI-100-5 SSI-100-6 SSI-100-7 SSI-100-8
par linaal foot $ 4.73
2 ft. length 3 ft. length 4 ft. length 5 ft. length 6 ft. length 7 ft. length 8 ft. length
$ 9.46 14.19 18.92 23.65 28.38 33.11 37.64
7 11 14 18 21 25 28
NOTE #1: Joining pieces not included with 2 ft. or 3 ft. sections.
*For comparative and estimating purposes only.
See page 46
Page 39
For complete epeclficetions refer to Trhnieei
`orm No. 9239-2 (Rev. 1/73)
HH-75-1
07647
HEATRIM ENCLOSURES, ELEMENTS AND ACCESSORIES
AMERICAN Si STANDARD
HYDRONIC HIATI NO
MODEL SS HEATRIM ENCLOSURES, ELEMENTS AND ACCESSORIES
Commercial baseboard panels designed for hotels, motels, apartments, hospitals, schools and churches. T he SS Heatrim is ideal for residential "hard to heat" areas such as bathrooms, hallways, etc.
DESCRIPTION
W TmOe
MODEL SS ENCLOSURES ONLY (Bulk Pack) Box includes 4 each of front and back panel, damper, sup port brackets, connecting tube wire . hangers and 3 joining piece sets (see Note #1). Fin ished with off-white prime paint.
Ordering Example: 1--box SS-8
MODEL SSI ENCLOSURES ONLY (Single Pack) Assembled Box includes 1 each of front and back panel, damper, joining piece set (see Note *1), sup port brackets and connecting tube wire hangers. Finished with off-white prime paint.
Ordering Example: 1-box SSI -4
ES-75-8 (%" lube) ELEMENTS ONLY (Bulk Pack) Box includes eight 8 foot lengths of element and slide cra dles.
Ordering Example: 1-box ES-7J-8
ES-100-8 (1" tube) ELEMENTS ONLY (Bulk Pack) Box includes eight 8 foot lengths of 1" element and slide cra dles.
Ordering Example: 1-box ES-100-8
ACCESSORIES
SS-3 SS-4 SS5 SS-6 SS-7 SS-8
SSI-3 SSI-4 SSI-5 SSI-6 SSI-7 SSI-8
ES-75-8
ES-100-8
* per lineel foot t 2.1 S
Four 3 ft. length* Four 4 ft. length* Four 5 ft. length* Four 6 ft. length* Four 7 ft. length* Four 8 ft. length*
$25.80 34.40 43.00 51.60 60370 68.80
per lineel foot $ 2.37
3 ft. length 4 ft. length 5 ft. length 6 ft. length 7 ft. length 8 ft. length
$ 7.11 9.48
11.85 14.22 16.59 18.96
per lineel foot $ 1.98
Eight 8 ft. lengths $126.72
* per lineel foot $ 2.42 Eight 8 ft. length* $154.88
R. H. 214' End Covers (Extend to Floor) ..................................................... ... L. H. 214' End Covers (Extend to Floor) ..................................................... ...
R. H. 6" End Covers (Extend to Floor) ................................................. _...... ... L. H. 6" End Covers (Extend to Floor) ......................................................... ...
Inside Corner Cover* ............................................................................................ ... R. H. Valve Enclosures with hinged access door.................... _.................. ...
L. H. Valve Enclosures with hinged access door........................................ ...
Wall End Pieces (Extend to Floor) .................................................................. ... Outside Corner Covers ..........................................................................................
14' Filler Pieces .................................................................................................. ...
2" Joining Piece Sets ............................................................................................ ...
Support Brackets, Slide Cradles, Damper Clips......................................... ...
Return Pipe Hangers...........................................................................
...
Damper Joiners ................................................................................
Connecting Tube Hangers..................................................................................
Ne: Add 25% to prict whon ordering in Itu than quonfitios indicattd above.
SS-ECR-25F SS-ECL-25F SS-ECR06F SS-ECL-06F SS-IC-90 SS-VER-06H SS-VEL-06H SS-WEP-2SF
SS-FPS-14 SS-JPS-02 SS-SBP-24 SS-WHR-50
for comparative and estimating purposes only.
Note #1: Joining pieces are not included with 3 ft. sections.
Box of 12 Box of 12
Box of 12 Box of 12
Box of 12 Box of 12 Box of 12
Box of 12 Box of 4 Box of 6 Box of 24
Box of 24 Box of 50 Box of 50 Box of 50
$18.70 18.70 22.70 22.70 9.35 40.05 40.05 6.65 16.05 16.05 6.70 13.30 6.65 5.00 8.00
***.
31 42 52 63 73 84
11 14 18 22 25 29
42
48
9 9 7 7 5 13 13 4 5 14 4 10 1 1 3
HH-75-1 See page 48
Page 40
For complete specifications rofsr to Technics! Cetslog Bulletin Form No. 9230-2 (Rev. 1/73)
07648
_ AMERICAN STANDARD
HYORONIC HEATING
CONVECTORS
MULTIFIN CONVECTORS
TYPE K - STOCK MODEL - FREE STANDING Expanded prices
For use on two-pipe steam and hot water systems only.
ttbiMI
No. 4 depth (4Vi" cabinet)
wait U
*e * MIRVt
IM'H. Tr4
hipP'M viM
Fri<
20" cabinet height
No. 6 depth (6Vi* cabinet) No. S depth (8Vi* cabinet) No. 10 depth (10Vi* cabinet)
nit
M.
nh vfpwl
ih'PRiM
Tre< Fric
iykf
Mif T4.
a*. ""'j ..(U Friis
Mit N.
e Hl|t
ppa<ee>M
Tfe* frill
20 420-20 24 424-20 28 32 36 40 44 48 56 64
10.6 13.0
18 S29.08 620-20 14.9 21 (32.29
20
30.88 624-20 18.4 24
34.87
628-20 22.0 27
37.53
632-20 25-S 29
40.19 832-20 31.7 33 $44.79
636-20 29.0 33
40JQ 836-20 36.0 37
47.99 1036-2Q 45.5 42
640-20 32.5 34
45.39 840-20 40 4 39
51.25 1040-20 51.2 48
644-20 36.1 37
48.05
648-20 39.6 40
50.71 848-20 49.2 46
57.84 1048-20 62.3 52
656-20 46.7 45
55.98 856-20 58.0 51
64.42 1056-20 73.4 58
664-20 53 B 52
61.30 864-20 669 59
71.02 1064-20 84 5 64
(55.10 59.30
67.62 75.87 84.12
24" cabinet height
20 420-24 24 424-24 28 428-24 32 36 40 44 48 56 64
12.1 20 (30.22 620-24 17.2 23 $34.01
14.9 22
32.29 624-24 21.2 26
36.94
17.8 25
34.41
628-24 25.4 30
40.06
632-24 29.5 33
43.20 832-24 35.6 38 (47.72
636-24 33.5 35
48.12 836-24 405 40
51.38 1036-24 49.0 45
640-24 37.6 38
49.19 840-24 45.5 44
55.10 1040-24 55.2 52
644-24 41.7 42
52.25
648-24 45.7 44
55.24 848-24 55.4 50
62.43 1048-24 67.1 62
656-24 539 50
61.36 856-24 65.2 55
59.74 1056-24 79.0 64
664-24 62.2 57
67.55 864-24 75.3 63
77.28 1064-24 91.0 ` 71
$57.71 62.29
74.51 80.07 86.98
32' cabinet height
20 620-32 18.7 29 (35.08
24
624-32 23.1 32
38.40
28
628-32 27.7 36
41.79
....
....32
632-32 32.1 40
45.12 832-32 40.9 45 (51.65
36
636-32 36.5 43
40.39 836-32 46.5 48
55.85 1036-32 55.0 54 $62.16
40
640-32 41.0 48
st.n 840-32 52.2 56
60.10 1040-32 61.9 59
67.29
....44
644-32 45.4 56
54.97
48
648-32 49.8 58
58.30 848-32 63.6 65
68.55 1048-32 75.3 69
77.28
56
656-32 58.7 67
64.89 856-32 74.9 73
77.00 1056-32 88.7 76
67.25
64
664-32 67.8 71
71.88 864-32 86.5 76
85.66 1064-32 102.2 84
7.37
Plugs and bushings are not regularly furnished with
Multifin Convectors, but are available for separate sale.
^4" 1" 1V4"
Trade Price Each $.36
Nate: For stock model cabinet extras, see page 41. Orderisj Exanple:
1-K-U6-32 Multifin.
V See page
Page 41
For complete specifications refer to Technical Catalog Bulletin Form No. 162*2 (Rev. 6 10/69)
HH-75-1
07649
CONVECTORS
.--I AMERICAN kSJ STANDARD
HYDRONIC HEATING
MULTIFIN CONVECTORS
0* -- _
A Nri_Kt ,.,
The actual output in square feet of catalog rating-Steam (215*F.) obtained with the cabinet heights furnished determines the price of convectors and cabinets sold in combination.
The total price of each order equals the amount of catalog square feet ordered multiplied by (he price per square foot, plus the unit extra charge multiplied by the total number of units Ardered.
SEE CURRENT LITERATURE FOR STEAM AND HOT WATER RATINGS
cabinet tv*
description
Trad* Prte* *r unit *trs *4 ft charg*
Stock Model
K
Floor Type-free standing.......................................................... S.75
$21.18
Not*: Price jhoum for estimating purposes only. For expanded prices, see page 38. For cabinet extras, see page iJ-
Special Service
F FG W
FS FSG
S
FR FRG FRGB
PR PRG
PRGB
Floor Type-free standing.......................................................... Floor Type-free standing-inlet grille.................................... Wall Hung-flat top.....................................................................
Free Standing-sloping top--inlet grille.................................. Wall Hung-sloping top..............................................................
Fully recessed-^," beveled edges........................................... Fully recessed-Xt" beveled edges-inlet grille.................... Fully recessed-Xa" beveled edges-inlet grille with
bottom overlap and liner bottom............................................
Partially recessed-1 V4", 2V4", 3", 5" flanged edges........... Partially recessed-1 Vs", 2V4", 3", 5" flanged edges-inlet
grille .............................................................................................. Partially recessed-1 Vi", 2 Vi", 3". 5" flanged edges-inlet
grille-with bottom overlap and liner bottom....................
$ .89 .89 .89 .84 .84 .84
.91 .91
.91 .94
.94
.94
$25.66 29.49 25.66 27.07 30.90 24.39
27.07 30.90
34.02 31.33
35.01
44.94
HH-75-1 "W See page 48
Note: For cabinet extras, see page 41.
For estimating purposes only, the following approximate shipping weights per sq ft may be used for Multifin convectors:
Multifin stock model -- 1.13 pounds. Also see page 38.
Multifin cabinets (less element) - ltt pounds.
Multifin cabinets (with element):
Types F. FR, PR -Impounds.
Types FS, W
-- 1V4 pounds.
Type S
-1 Vi pounds.
Orderiag Usaplit:
Stock Model Multifin with an optional feature: 1 K-840-24 Multifin with Metal Trim Strips.
Special Service Multifin with an optional feature: 1 PR-S40-32-2W Flange, Multifin with Knob Damper.
Page 42
For complete specificaiiona refer to Technical Catalog Bulletin Form No 162-2 (Rev 6 10/69)
07650
(AMERICAN SiSTANDARD
HYDRONIC HEATING
MULTIFIN CONVECTORS - continued
CONVECTORS
eonvoctor langth Inch**
20 24 28 32 36 40 44 48 56 64
Elements only (when sold less cabinets)-- two-pipe steam or hot water
No. 4 depth
No. 6 depth
No. 8 depth
No. 10 depth
approx.
unit hipping Trad*
no. weight
Met
approx.
unit hipping Trado
no. woight
Prlco
approx.
unit hipping Trad#
no. walght
Prtco
approx.
unit hipping Trad#
no. walght
Prtco
420 424
428 432 436
440 444 448
456 464
8
SI 6.78 620 13
820.57
820
15
$24.30 1020
10
18.17 624 16
22.57
824
19
28.08 1024
12 19.57 628 19 24.56 828 23 30.09 1028
14 21.03 632 22 26.29 832 27 32.75 1032
16
22.84
636 25
28.29
836
31
35.67 1036
18
24.58 640 28
30.69
840
35
38.20 1040
20
26.22
644 31
32.75 844 39
41.06 1044
22
27.75
648 34
35.00
848
43
43.73 1048
26
30.88
656 40
39.00
856
51
48.85 1056
30
34.14
664 46
43.46
864
59
54.11 1064
Note: Elements only are furnished less floor supports. Multitln elements (or specie! one-pipe tleam header application--not available.
Orderiag Example: 1-420 Multifin Element only--no cabinet.
21 26 31 36 41
46 51 56 66 76
827.95 32.42
36.15 39.67 43.79
47.26 50.58 53.77
59.90 67.22
Ratings: Ratings of Multifin Convectors have been determined in accordance with the method of testing and rating outlined in Commercial Standard Code CS140-47 and amendments and said ratings have been approved by the Convector Rating Committee.
Standard Cabinets: Standard cabinets are furnished in prime painted sheet steel--reinforced, No. 18 gauge front and No. 20 gauge back, ends and top, rounded corners, front discharge grille, and open bottom inlet, in heights, lengths and depths to accommodate convectors as currently catalogued.
HH-75-1
MINIMUM CABINET HEIGHTS WITH DAMPERS FOR MULTIFIN
Type cabinet
F.FG W FS, FSG S FR, FRG, FRGB PR, PRG, PRGB
Muttlfln
20" For all depths 20" For all depths 20" For all depths 20" For all depths 20" For all depths 20" For all depths
Cabinet heights shown for types W and S are nominal heights, actual heights are S' less.
Page 43
For complete specifications refer to Technical Catalog Bulletin Form No. 162*2 (Rev. 6 10/69)
W See page 48
07651
CONVECTORS
(AMERICAN k2iSTANDARD
HYDRONIC HEATING
CABINET EXTRAS FOR MULTIFIN
CABINET EXTRAS-STOCK MODEL MULTIFIN ONLY
ITEM
DESCRIPTION
DAMPER
Knob Operated Damper Package ....................................... ............... each
METAL TRIM STRIPS
For recessing stock models only 20" to 36" long ........................................................................ 40" to 64" long ........................................................................ ............... each
GRILLE AIR VENT
Snap-on Inlet Grille for Stock Models Only ....................
Air chamber with extended tube, manual vent ............... Air chamber with Dole No. 20JR auto-vent ......................
*Not: Items also availabl* for special service Muhifm.
Trada Prict
t 7.33
12.58 16.10
5.59
7.13 7.13
SPECIAL SERVICE CABINET EXTRAS--MULTIFIN (Prices indicated are for standard catalogued sizes only)
ITEM DAMPER
DESCRIPTION Knob or Institutional Type ...................................................................... each
Trad* Pric*
5 8.72
ACCESS DOOR
In standard locations Ir 2, 3, 4, 7 or 8 as shown in current literature.
Hinged type with Slotted Head operator ............................................. each Hinged type with Allen Head operator ................................................. each Note: Access doors in other than standard locations
8.72 10.38
Pnce on application
TAMPER PROOF SCREWS
Phillips or Allen Head screws (other than standard Slotted Head) per cabinet
1.41
CAM LOCKS
Allen Head Cam Locks (Allen Keys Not Furnished): Types F, FG. FS and FSG......................................................... per cabinet Types S and W (MultifinOnly) ............................................... per cabinet
Types FR. FRG. FRGB, PR, PRG, PRGB Note: Additional charge per order $6.29 f
t0,48 .......... per P
7.18 7.18 31.68 39.67
INSULATION
hi" Celotex or Fibreglas on outside of cabinet
Back only...................................................................................... per cabinet Back, ends and top....................................................................................... percabinet hi" Millboard on outside of cabinet Back only....................................................................................... per cabinet Back, ends and top....................................................................................... percabinet
14.77 18.24
34.61 49.19
SOUND DEADENING MATERIAL
Approx. V4" thick-inside front panel only................................ per cabinet
14.64
SEALING STRIP
For standard length FR, FRG and FRGB cabinets only CV" x %" Polyurethane) ......................................................... per cabinet
6.13
STIFFENER
All fronts 48" and longer, or 82" and higher have stiffening channel spotwelded to inside front in horizontal position at no additional charge. Stiffening channel on fronts other than standard ............................................................................................. per cabinet
2.07
METAL TRIM STRIPS
For recessing Types F and FG Multifm convectors only
Cataloged heights and lengths up to 36'........................................... each Cataloged heights and lengths 40" to 64"......................................... each
14.11 17.38
END POCKETS KNOCKOUTS
Specify right or left hand side 4' end pocket with No. 18 gauge vertical baffle............ per end pocket 8' end pocket with No. IB gauge vertical baffle.............. per end pocket
Are optional-Furnished only on request
7.85 12.58
Pnct on application
HEAVIER GAUGE CABINETS
. Trade-Price per square foot of cabinet output Front Only
No. 18 gauge......................................... No. 16 gauge......................................... No. 14 gauge..........................................
-- $.10
.19
Unova Only
5.10 .12 --
HH-75-1 See page 48
Page 44
For complate specifications refer lo Technical Catalog Bulletin Form No. 162-2 (Rev. 6 10/60)
07652
HYDRONIC HEATING
GENERAL INFORMATION
BOILER RATINGS
The net I=B=R boiler ratings represent the maximum net loads that may be connected to the boilers. The net I=B=R steam ratings are based on a piping and pickup allowance of 1.333 except where an appropriate piping and pickup column is shown. Steam-sq. ft. ratings are based on 240 Btuh per sq. ft. The net 1=B=R water ratings in Mbh are based on a piping and pickup factor of 1.15. Water sq. ft. ratings are based on 150 Btuh (170* water) per sq. ft. For installations having unusual piping and pickup requirements, AmericanStandard should be consulted before selecting a boiler.
For forced hot water heating systems where the boiler and
piping are within the area to be heated, the boiler may be selected on the basis of its gross output.
Sufficient radiation must be installed for the requirements of the building to be served.
In order to select the proper size boiler, calculate the heat loss of the building, then divide this figure by 1,000 to get the heat loss expressed in Mbh. Select a steam or water boiler which has a net I=B=R Mbh rating equal to or greater than this figure using the appropriate steam or water column.
GAS FIRED BOILERS
American-Standard Gas boilers are design certified by the American Gas Association.
Ratings shown are for installation at sea level and at elevations up to 2,000 feet. For altitudes above 2,000 feet, ratings should be reduced at the rate of 4% for each 1,000 feet above sea level.
OIL FIRED BOILERS
The firing.rates or I=B=R burner capacities -- gallons per hour--are based on the use of oil having 140,000 Btu per gallon heat value.
BUILT-IN TANKLESS WATER HEATERS for G-2 Wafer, G-40, G-IO, V-3, V-3M, FR-A-S, A-S, DPT, PFA-3, PFA-5, and VPT
All tankless type built-in water heaters are rated in gallons per minute on the basis of a minimum boiler water temper ature of 200* F. The maintaining of 200* F boiler water temperature with rated flow through a tankless type builtin water heater is dependent on the output of the boiler.
Increase the boiler size 12 Mbh for each bathroom in excess of two.
In those areas where excessive liming conditions exist in the water, use of built-in tankless type water heater is
not recommended except when provision is made for reg ularly cleaning the heater.
EXTERNAL WATER HEATERS FOR AMERICAN-STANDARD STEAM BOILERS
External tank or tankless type heaters can be connected to all American-Standard Steam boilers when provision is made in the supply and return piping of the heating system.
When an external tank type heater is used and the domestic demand exceeds 75 gallons in a 24 hour period, increase the boiler size 120 Btuh for each gallon of storage tank capacity.
When an external tankless type heater is used, increase the boiler size 12 Mbh for each bathroom in excess of two.
(Note: G-10 Steam boilers can be provided with external water heater tappings for water to water heat exchangers. See G-10 optional eauipment pages for price and availabil ity.
INSTRUCTIONS FOR ORDERING GAS BOILERS:
Specify complete boiler number.
Specify type of gss (whether natural or propane), Btu (heat value of gas), specific gravity.
Specify elevation at point of installation if in excess of 2,000 feet and indicate barometric pressure.
In odditian, for Pressure Fired PFA-J pas Fired and gas-ail fired units, specify gas pressure at gas train inlet.
Specify optional equipment in detail.
BOILERS:
REPAIR PARTS For current price, contact your American Standard distributor
Refer to Boiler Repair Parts Catalog Form 9100-2 & Revisions for Current Repair Parts
Obsolete and Discontinued Boiler Repairs are available thru:
H. C. Oswald Co. 120 E. 124th St. N.Y.C., N.Y. 10035
OIL BURNERS:..........................................................................................................................
Refer to "American Standard Oil Burner Repair Parts Catalog" 73197-2 dated July, 1974
See page 43
Page 45
HH-75-1
07653
I AMERICAN 12< STANDARD
HYDRONIC HEATING NOTES
o
HH-75-1 See page 48
Page 46
o
07654
IAMERICAN kSiSTANDARD
HYDAONIC HEATING
NOTES
See page 48
Page 47
HH-75-1
07655
* ' GENERAL TERMS
F.O. IOX MO). NSW ItUMSWlOC. N.J. OOfO)
TRADE PRICE BOOK
Illustrations and descriptions of ordering Numbers listed In this price book will be found In the current American-Standard Hvdronic Products Catalog and literature. Items Illustrated In product literature and not included in this price book are discontinued. The illustrations In this price book although actual representations of certain products In the line, do not necessarily show sizes and details of all products In the line.
^This price list has been prepared for the convenience of American-Standard distributors and their trade customers only. The trade prices shown are guides only and do not purport to represent actual prices prevailing In any particular market and are not Intended to interfere with our distributors* right and responsibility to establish their own resale prices.
All prices herein set forth supersede all prior price lists and are subject to change without notice. The Seller may also, from time to time, discontinue without notice the sale of any of the products listed herein.
INVOICE MINIMUM All distributors' orders. Including repairs, which aggregate less than $25.00 net will be billed at $25.00.
TERftlS AND CONDITIONS APPLYING TO ALL SALES OF GOODS BY AMERICAN-STANDARD THROUGH U.S. PLUMBING/HEATING TO ITS DISTRIBUTORS
All sales of goods by American-Standard through WH Plumbing/Heating to its distributors are made subject to terms and condition* printed below, in its bulletins and on its acknowledgment of order, invoice and quotation forms. These terms and
conditions, are as follows: MICC
Goods sold by the Sailor will bs bitted to N Buyer according to tho prices snd terms contained in its currant bulletins and price books. In tho case of ordars for goods for which no prioa la currently In affact tha price will be determined by (ho Seiler and set forth in tho tovoioo issued after shipment of the goods.
Tate Any tax or ether Government charge now or horesftor levied upon the production, sate, use or shlnmept of goods ordered or sold, wilt bo charged to and paid for by tha Buyer.
DELIVERY
Transportation ftMea. Delivery to tho initial carrier shall constitute delivery to tho Buyer. The Seller's responsibility ceases upon delivery in good order to such carrier, and eU goods are shipped at tha Buyer's risk.
The Buyer la urged to examine all deliveries carefully before signing transportation receipts. If goods are vtalbfy damaged, tha Buyer should insist that written confirmation of tha damage be noted on the freight bill or dray ticket by tha agent of tha carrier. If damage it discovered after unpacking, the carrier should be notified at once, so that inspection ean be made snd the claimed damage substantiated by the carrier.
Interference witi Delivery. The Salter has no obligation to delirer goods against any order until it has accepted the order by issuance of its acknowl edgment of order. In any event the Seller will not be liable for any delay or failure in the delivery or shipment of goods against an accepted order or for any damages suffered by reason thereof, when such delay or failure, is, directly or indirectly, due to accident (in manufacture or otherwise), fire, flood, riot war, embargo, labor stoppages. Inadequate transportation facili ties, shortage of material or supplies, delay or default on tha part of its vendors, regulation by Government authority, or any* Hite or dissimilar cause beyond Its control.
CONSUMER PROTECTION - WARRANTY
American-Standard products normally reach owners or consumer-users through an industry channel of distributors and plumbing and heating con tractors. Experience has shown that deists of defects in our products gam erally relate to abuse or to other damage which occur after our sole and are not our responsibility. Since determining proper responsibility requires local inspection, our warranty (sot forth below) extendi onfy to our direct buyers; distributors are boat equipped to obtain tie facts underlying claims, to place responsibility where H belongs and to recommond/handte repair or re placement.
Sinoe local code requirements vsry greatly throughout the country, users of heating products should consult in advance with licensed contractors to determine whether there are any coda restrictions on tha use of a specific product. American-Standard makaa no representation nor warranty regarding, and shall not be responsible for, any coda compliance.
American-Standard is proud of Its record for product quality and for fair ness in handling warranty matters; and, if an ultimata user of our products should feel our warranty system described above does not wort fairly in his case, he should writs (ha Office of the President, Director of Consumer Affairs. W. H. Plumbing/Heating. American-Standard. Box 200). New Brunswick, New Jersey 0890).
CONTRACT WITH BUYER
Acceptance of Orders. Orders will be accepted only by the Seller's usual acknowledgment of order containing terms and Conditions applicable thereto. No terms and conditions appearing in a Buyer's order that are at varianca with tfie Seller's terms and conditions shall ba binding upon the Seller unless specifically agreed to by it in writing. Unless tha Seller spe cifically so agrees in writing in acknowledging any ordsr, any terms and conditions appearing in a Buyar'a order contrary to thoae statsd herein and n such acknowledgment of order are to be deemed waived by tha BuyerReceipt by the Buyer of the acknowledgment of order without prompt objec tion to the terms and conditions therein and hsrain sat forth, constants acceptance by the Buyer of such terms and conditions.
Cancellation of Orders. Artec the Seller's acknowledgment of order has been issued, an order may ba modified or cancelled only upon written agreement by die Seller. Orders for goods othar than thoae of standard manufacture will not be cancelled after a commitment has bean made or production scheduled.
Credit ter Returned Goode. Merchandise may not be returned for credit unless the Salter has agreed to accept it. Where returns are accepted, a deduction of 20% or $20, whichever is greater will be made for rehandling All transportation coats for returned goods must be paid by the Buyar. in any event, only saleable merchandise of standard manufacture may be returned for credit
CredH Approval. Buyers' orders are accepted subject to credit investiga tion and approval, and delivery may be withheld or shipment stopped in transit on accepted ordars without any liability on the Sailer's part. if. in its opinion, tha Buyer's ability to pay tor the motehondlao on these terms and conditions to in doubt
SHORTAGE* OR VARIANCE*
American-Standard warrants only to its distributors snd other Direct Buyers thst. at its option. It will furnish by freight s replsesmsnt tor, or repair, or refund the purchase price paid by its distributor or other direct buyer, for any product of its manufacture or pan or portipn thtreof, proved to Its satisfaction to be defective in material or workmanship under normal use and service within one year after installation. In no case will American-Standard (ba responsible for any special, direct, in direct or consequential damages, nor for labor or transportation ex panses relating to such replacement or repair, nor will it be held re sponsible for werrsnty ad|ustments costing more than the price of the product to its distributors snd other Direct Buyers.
There la no oflier warranter express or Implied, fnchidteg no implied warranty of merchantability or knplted warranty ter fitness for a particular purpose.
No claims for variances from or shortages in ordars will be considered unless presented whhln 60 days after receipt of goods.
MODOCT AND PACKAGING CHANGES
Factors beyond the control of the Seller and tha need tor continuing im provement of product require the making of changes from lima to time in products and their packaging. Tha right la reserved to make reasonable changes of any kind without notice and to deliver revised designs or models of goods against any order, unless on flte tees of the acknowledgment of order this right la specifically waived.
The Seiler shall have no responsibility whatever with reaped to changes made by the manufacturer in products or their packaging sold but not manufactured by the Setter.
Goods of eater manufacturers ooM by American-Standard are not wanwriad
unteea accompanted by an axpraes written warranty, but the Salter will endeavor to secure for tea direct Buyers the benefits of warranties extended by such other manufacturers for such goods.
SNIPPING WEIGHTS
Tha shipping weights given herein are approximate, for Buyers' con
venience only, snd are net guaranteed.
*
AMERICAN STANDARD Inc.
HH-75-1
Page 48
07656