Document Ky00JEZ9g3oNneaRGo6Yv7ar

f C' trade price book for AMERICAN-STANDARD Hydronic Heating Equipment* Hydromcs . . the science of heat.ng and cooling with water. PRODUCTS Boilers--Cast Iron Electric Packaged Boilers Gas-Packaged Units Non-Pkg Boilers Modular Boilers Miscellaneous Options Tankless Water Heaters Oil-Packaged Units Non-Pkg. Boiler Burner Units Boilers Only Miscellaneous Options Tankless Water Heaters Combustion Chambers (A-5) Pressure Fired Boiler Burner Units Oil Gas Gas/Oil Comb. Miscellaneous Options Tankless Water Healers Oil Burners and Controls Zone Valves Hydronic Assembling Tools Non-Ferrous Radiation Baseboard Panels--Heatrim '(Ot< vector--Multifin Cabinets General Information Repair Parts Reference Terms PAGE 36 2-5, 9 6-8, 13. 14 10-13 15-18 16-17 19-20 21,31 22, 32 23 23, 30 32 24,26 28 29 25, 27 25.30 33. 34 33 35 37-40 41,43 42, 44 45 45 48 packaged boilers GAS FIRED WATER ry< AMERICAN LSJ STANDARD HYDRONIC HEATING GPM(X) PACKAGED GAS BOILERS Completely Smcm.Mo!. ,uv->wr<! ami jai kn.t;u. RegOTarlv supplied for 115 volt (ill cycle powei supply with 2-1 volt sv.-tem 01 self energizing controls at no extra charge. (Specify controls desired I Built-in purge valve. Built-in air separator I patented "Elimmatre"). Intermittent circulator opeiation. Design certified by A.C..A. foi combustible floor and closet installations. Cast iron drilled port burnets are standard equipment for natural gas. Ribbon burners ate standard for piopane gas--optional for natural gas at 1(1',; reduction of rating as indicated by model number suffix R. Tested and equipped for 3d lbs. water woi king pressure. Ratings shown are foi installation at sea level ami up to 2.(did feet. WATER -- for natural gas -- 100% shut-off packaged botlar number GPM(X)-3 GPM(X>-4 GPM(X)-5 GPM(X)-6 GPM(X)-7 GPM(X)-8 AG. A. | A G.A input 1 output Mbh ; Mbh 66 1 52 8 99 79 2 132 105 6 165 132 0 198 158 4 231 184 8 nat l = B = ft rating Mbh 46 1 68 7 92.2 114 8 137 4 160 9 WATER -- for propane gai -- 1 OO % shut-off GPM(X)-3R GPM(X)-4R GPM(X)-5R GPM(X)-6R GPM(X)-7R GPM(X)-8R 60 1 90 ! 120 1 150 i 160 210 ; 48 72 96 120 1 44 168 41.7 62 6 83 5 104 3 125 2 146 1 j | 1 nat rating *q. ft. water 307 458 615 765 916 1073 278 417 557 695 835 974 ! T Trad r Prtcet i with ttanderd equipment j GPM(X) GPM 1 with lata 1 *ionion lank xpantion tank 1 $418.00 1 457.00 , 521.00 | 595.00 668.00 740.00 $386.00 427.00 493.00 567.00 640.00 713.00 1 418.00 | 457.00 j 521.00 ! 595.00 { 668.00 ! 740.00 386.00 427.00 493.00 567.00 640.00 713.00 aDproi hipping wignt 201 244 263 341 337 434 2C1 244 253 34 1 357 434 Ordering Eiomplet: Packogad boiler with itondord equipment: 1 GPMX'6 boiler with 24 volt control! Not gat, 1000 fitu, .6 ig. ?. Packaged boiler with optional equipment; 1 GPMX-7R boiler with 24 volt control! for conjtont circulator operation. Not. goi. 1000 Btu, .6 ig. 1 converiion kit fr6m natural to propane go!. 3. Pockaged boiler with jlondard equipment. 1 GPMX-4R boiler with 24 volt control! Propone go!. 2500 Btu, 1.53 !g. Standard Equipment VS00 series manifold gas valve Draft Hood Expansion Tank 1U" Circulator with Piping Wiring- Harness Auto Air Vent ASME relief valve, 30 lb. Automatic Fill Valve Diain valve Specify 24 Volt . . . or . . . Specify Seif Energizing TS22D theimostat L408i'D limit control R822*'*R transformer (40\*Ai and circulator relay T822D thermostat LS14SG limit anti cncuiato; ie!ay i-jnVA i Optional Equipment Constant cncu'ation (24 V) L4081B limit and reverse acting circulate controls with AT20D transformer. Furnished at no additional charge. Constant circulation (S.E.) L4f8lB limit and >everse acting circulatoi control and TS822A thermostat. Furnished at no additional chaige Conversion Kits: Boileis must he specified with suffix letter R. Reduced propane ratings apply. Natuial to Piopane gas.................................................. Trade Price $8.80 Pi opane to Natural gas................................................... T Trade Price $8 * Zone vahe packages aie available for water boilers. For details a-, prices, see page 33. hh-75-i See page 48 For cce-D'etc .i-v-c'.5 'e'e' *c Page 2 Ca - 3. 1 N? ?*>$* B? 07610 AMERICAN Si STANDARD hvdronic heating PACKAGED BOILERS GAS FIRED WATER G-2 PACKAGED GAS BOILERS Completely assembled--pve-wired--controls for foiced circulation--deluxe jacket. Available with or without tankless heater for domestic hot water. Built-in air separator (patented "Elinunaire"). 30 lbs. water working pressure. Regularly furnished for 11 f> volt. 60 cycle with '24 volt control system. Listed rating for installations at sea level to 2,000 feet. WATER--for noturol and propone gases--100% shut-off pieki|id boiler number AG.A. input Mbh A.G.A. output Mbh tankless heater number |=W = H rating net l=8=R rating Mbh net rating sq ft water Packaged boilers with factory installed tankless heater G-24-DPT 90 72 218 2 Vi 62.6 417 G 25 DPT 120 96 222 3 83 5 556 G-26DPT 150 120 222 3>/. 104 3 695 G 27-DPT 180 144 222 3 V2 125 2 834 Packaged boilers less heater G-23-DP G-24-DP G-25-OP G 26-DP G-27-DP 60 48 90 72 120 96 150 120 180 144 41 7 62 6 83 5 104 3 125 2 278 417 556 695 834 ^Gallons of water oer mmute reaie 2 *'ZT~ 60? \z 160? w tn 270- CO >' waie' Trade Price with standard equipment $628.00 702.00 771.00 835.00 oe-a; 494.00 581.00 650.00 733.00 783.00 epprqx. shipping weight 416 481 551 620 333 403 472 542 503 Ordering Examples: 1. Packaged boiler less heater with standard equipment: 1 G-24-DP boiler Nat. gas. 1000 Btu, .6 sg. 2. Packaged boiler with factory installed heater with optional equipment: 1 G-26-OPT boiler with ribbon burners and Nat. to Propane conversion kit. Na*. gas. 1000 Btu, .6 sg 3. Packaged boiler with standard equipment: 1 G-25-DP boiler with ribbon burners Propane gas, 2500 Btu. 1 53 sg. Standard equipment V3u0 Sei les manifold gas valve 1 ' " Circulator with piping ASME relief valve Diaft hood (for G-23 only, shipped m sepai ate cai ton i Presst.ie and teir.pei atu'e gauge Wii ing hai r.es.- AT2bD trar.sfoi mei rJiV. less heater bo;lers oniy} Additional standard equipment for boilers with heater Tankless heater as listed above T822D (24V. > theimostat L8124E (24V.) or L8124B (S.E.) triple Aciuastat relay Additional standard equipment for boilers less heater T822D i 24 V. i or TS822A (S.E.) thermostat L4"3lR (24 V. and S.E i combination high !;n.it and cii cu'a'.nt conti ol Optional equipment Self-energizing controls with VSS2<i gas valve, available when spec.net: on order ........................................................................................................... no chai gt- L8I48E (24\".) or L8148G (S.E.) combination limit lelay........nochaige Natural In Piopane gas conversion kit1-. Oidei boiler "with i ibhon burners" and "N'atuial to Propane conversion kit": G-23 thru G-27 ....................................................................... T Trade Price 57.65 Floor shield for comhustible finonng. Add suffix lettei "C" to lmde> numlier ................................................ ad<( 54.45 Note: Manual opening fcatuie is furnished with self-er.ei gizmg cor.tio .as listed above. Zone valve packages are available foi watei linilei.- Foi details ard prices, see page 33. y? See page 48 co^c'ete specified! Page 3 .`a lz No i3* b HH-75-1 07611 PACKAGED BOILERS GAS FIRED STEAM ^AMERICAN Lsd STANDARD HYDRONIC HEATING G-2 PACKAGED GAS BOILERS Completely assembled--pre-wned--controls foi steam .application-- flush oi' deluxe jacket. Repularly furnished for 115 volt. GO cycle with 24 volt control system Listed ratings for installations at sea level to 2.000 feet. STEAM--for natural and propane gases--100% shut-off packaged boiler number A.G.A. input Wbh A.G.A. output Mbh net 1 = 8 = R rating Mbh sq ft G-23SP* 60 48 36 G-24SP* 90 72 54 G-25-SP* 120 96 72 G-26-SP* 150 120 90 G-27SP* 180 144 1C8 Acd sutfiK letter "F" for flush or 0" tor seluxe jacket 150 225 300 375 450 Trade Price with standard equipment flush Jacket deluxe Jacket $414.00 503.00 578.00 649.00 711.00 $436.00 524.00 600.00 669.00 733.00 approx. shipping weight 310 376 443 518 581 Standard equipment YSfio Series manifold gas valve No. 67-GAP. I 24V. and S.E.) low watei cut-off Gauge glass with trim Draft hood ifor G-23-D and G-23-F thru G-2T-F. shipped in separate carton) T822D (24V.) or TS822A (S.E.i thermostat PA4U4A (24V. and'S E.) pressure limit control AT20D trar.sfoimer levcept S.E i ASME safety valve Steam gauge Ordering Examples: 1. Packaged boiler with standard equipment: 1 G-26-SPD boiler Nat. gas, 1000 8tu, .6 sg. 2. Packaged boiler with optional equipment: 1 G-24-SPD boiler with self-energiting controls Nat. gas, 1000 Btu, .0 sg. 3 Packaged boiler with standard equipment 1 G-27-SPD boiler with ribbon burners Propane gas, 2500 Btu. 1.53 sg. Optional equipment Self-energizing controls (with VS820 gas valve) ..........................no charge Floor shield for combustible flooring ................................................ add $4.45 Natural to Propane gas conversion kits. Order boiler "with ribbon burners'1 and "Xatuial'to Propane conversion kit": G-23 thru G-27 ....................................................... Trade Price $7.65 Note: Manual opening feature is furnished with self-energizing controls as listed above. For Additional Optional Equipment, See page 15 & 16. For substitution of No. 47-2 losv water cut-off and feeder combinatior specify on order and add .............................................................................. $56.00 HH-75-1 See page 48 Page 4 fo' compete SDecihca'iors re'*' to Tec'**' :a Caiaicj Bulletin Form No TtB-2 i^ev 5 07612 ^AMERICAN STANDARD HTORONIC HEATING PACKAGED BOILERS GAS FIRED WATER C-2 PACKAGED ALL-PURPOSE GAS SC'LERS Completely assembled--pre-wired--for forced circulation or gravity installation--deluxe jacket. Built-in air separator (patented "Eliminaire"). 30 lbs. water working pressure. Regularly furnished for 115 volt, 60 cycle, with 24 volt control system. Listed ratings for installations at sea level to 2,000 feet. WATER--for natural and propane gases--100% shut-off packsgad bolter number A.G-A. input Mbh A.G.A. output Mbh net IsBsR rating Mbh net rating sq ft watar G-23-DPG 60 48 41 7 278 G-24DPG 90 72 62 6 417 G-25DFG 120 96 83 5 556 G-26-DPG 150 120 104 3 695 G-27-DPG 180 144 125 2 834 Trade Price with standard equipment less thermostat S362.00 451.00 530.00 603.00 666.00 approx. shipping weight 307 373 438 511 574 Standard equipment V800 Series manifold gas valve L4080B (24V. and S.E.) immersion limit control ASME relief valve Pressure and temperature gauge AT20D transformer (except S.E. I Draft hood (for G-23-DPG only shipped in sepai ate carton i Ordering Examples: 1 Packaged all-purpose boiler with standard equipment: 1 G-25-DPG boiler Nat. gas, 1000 8tu. .6 sg. 2. Packaged all-purpose boiler with optional equipment: 1 G-26-DPG boiler with self-energizing controls Nat. gas, 1040 Btu. .65 sg. 3. Packaged all-purpose boiler with standard equipment: 1 G-24-DPG with ribbon burners Propane gas, 2500 Btu. 1.53 sg. Optional equipment Self-energizing controls (with VS820 Series gas valve) available when specified on order ....................................................................................... no charge Natural to Propane gas conversion kits. Order boiler with "ribbon burners'' and "Natural to Propane conversion kit" Trade Pi ire ST-65 Note: Manual opening feature is furnished with self-enei gizing conti nls as listed above. Thermostats for 24V. and S E. control systems are available. For model and prices, see page 34. Zone valve packages for water boilers. For details and prices, see p3ge 33. Floor shield for combustible flooring ............................. Trade Price $4.45 See page 48 Page 5 For ccrhc'eie sBeci*'C3tions refer :o Tecr'nica1 Cara BL.'ke 1.r. Form No 710-2 tPev 5 74) HH-75-1 07613 NON-PACKAGED BOIIERS GAS FIRED WATER AND STEAM ^AMERICAN iSiSTANDARD HYDRONIC HEATING ill H* G-2 NON-PACKAGED ALL-PURPOSE GAS BOILERS Section? assembled--for Water with or without tsnH heater- for domestic hot water. Steam without tankless coil. Flush" or'Jeluxe jacket. 30 lbs. water, 15 lbs. steam working pressure. Regularly furnished for 115 volt, GO cycle, with 24 volts control system. Listed ratings for installation at sea level to 2,000 feet. WATER--Natural and Propane Gases--100% shut-off. (Available with factory installed Tankless heater, see options, page 16) boiler number AGA. input Mbh A G A. Mbh net l=-8 = R rating Mbh net rating q ft water ^ Trade Price with standard eouipmant lets thermostat flush Jacket deluxe Jacket G-23--W G-24-*W(T) G-25-'W(T) G-26-* W(T) G-27-`W(T) G-28-*W(T) G-29-*W(T) G-210-*W(T) G-211-*W(Tj 60 90 120 150 180 210 240 270 30O 48 41 7 278 6327.00 $349.00 72 62 6 417 414.00 436.00 96 83 5 556 494.00 516.00 120 104.3 144 125 2 168 146 1 695 834 974 567.00 $28.00 701.00 589.00 650.00 723.00 192 167 0 1113 216 187 8 1252 240 208 7 1391 772.00 835.00 906.00 794.00 857.00 928.00 'Substitute <et;er ' F tor tijsn or 1 O ' de'une jacket SuM'k "T" denotes ic'ced c rcutalicn DOtler eautoced *ttn factory i.-ts'aiied tanmess Vate- tsee sage tS for added cra'ge I 295 353 426 500 566 630 699 790 863 STEAM--Natural and Propane Gases--100% shut-off. G-23'S G-24-*S G-25-*S 60 48 36 90 72 54 120 96 72 G 26 *S G-27--S G-28-*S 150 120 90 180 144 108 210 168 126 G-29-*S 240 192 144 G-210-*S 270 216 162 G-211-*S 300 240 180 150 225 300 375 450 525 600 675 750 'Substitute tetter "F" for flush or "D" for deluxe jacket. $385.00 472.00 552.00 625.00 686.00 759.00 831.00 893.00 965.00 $407.00 494.00 574.00 647.00 708.00 781.00 853.00 915.00 987.00 310 368 442 517 583 648 718 809 883 Ordering tramples. 1. Non-packaged all-purpose water boiler with standard equipment and flush jacket1 G-27-FW boiler Nat gas. 1000 Btu. 6 sg. 2 Non-packaged all-purpose water boiler with optional equipment and deluxe jacket. 1 G-210-DWT boiler with (11 No. 232 tankless heater installed Nat gas, 1000 Btu, 6 sg 3 Non-packaged all-purpose steam boiler with standard eouipment and flush jacket1 G-25-FS boiler with ribbon burners Propane gas, 2500 Btu. 1 53 sg Standard equipment YSOh Senes manifold gas valve AT20D Transformer (except S.E.) Drain valve Draft hood (for G-23D and all flush jacketed boilers, shipped in separate carton) Additional standard equipment Water boilers ASME relief valve Pressure and temperature gauge L4080 (24V. and S.E.) Aquastat limit control Steam boilers ASME safety valve Steam gauge PA404A (24 V. and S.E. I piessure limit control No. G7-GAR (24V. and S.E.) low water cut-off Gauge glass with trimmings Optional equipment Side outlet ASME steam safety valve available--no charge if specified Natural to Propane gas conversion kits. Order boiler "with ribbon burners" and "Natural to Propane conversion kit": G-23 thru G-27 ................................................................... Trade Price $ 7.65 G-28 thru G-211 ................................................................. Trade Price $10.30 Floor shield for combustible flooring ...................................Trade Price $ 4.45 Additional optional equipment--see pages 15. 16 & 18. Thermostats--see page 34. Note: Zone valve packages for water boilers. For details and prices, see page 33. hh-75-1 See Page 48 Page 6 For c0,r,Diele soecilicanons fete- lo Teo-mca' Ca-alcp Buiielin Form No 718-2 (Rev S 7*1 07614 ^AMERICAN SiSTANDARD HYDRONIC HEATING NON-PACKAGED BOILERS GAS FIRED WATER G-40 GAS BOILERS--WATER Deluxe jacket with built-in draft hood. Regularly furnished for 115 volt. GO cycle powei supply with 21 volt rontiol system (self energizing optional). jii lbs. water uoikmg pressuie. Listed ratings for installation at sea level to 2.000 feet. WATER--For Natural and Propane Gates--100% Shut-Off. For Built-In Water Heaters, see page 16. boiler number G-403-W G-404-W G-405-W G-406-W G-407-W G-408-W G-409-W G-4010-W G-4011-W G-4012-W G-4013-W G-4014-W A.<3. A. input Mbh 150 225 300 375 450 525 600 675 750 825 900 975 A.G.A. output Mbh 120 180 240 300 360 420 480 540 600 660 720 780 net !=B=R rating Mbh 104.3 156 5 208.7 260.9 313 0 365.8 417 4 469.6 521.8 574 0 626.2 678 4 net feting tq. ft. water 695 1043 1391 1739 2086 2434 27B2 3130 3479 3327 4175 4523 yp Trade Price | with j standard tquipmtnl ( leaa thermostat $ 543.00 691.00 i 837.00 992.00 1 1147.00 1265.00 1412.00 1559.00 1707.00 1859 00 2006.00 2153.00 approx. shipping weight 744 921 1117 1297 1475 1647 1820 1994 2195 2364 2533 2702 chimney sue inside diam. in. height feet 8 15 8 15 8 15 10 15 10 15 10 15 10 15 12 15 12 15 12 15 12 15 15 15 NOTE: Available as factory assembled section; in all sizes ............................................................. Trade Price per section $11.00 Standard equipment V800A Combination Gas Valve: G-403 and G-4G4 for Nattnai Gas V800B Combination Gas Valve: G-403 thru G-407 for Propane Gas G-50AAG Combination Gas Valve: G-4o,". and G-loC for Natural Gas V88A or B-50 Diaphragm Gas Valve: G-407 thru G-4<il4 fm Natuia! Gas C.-40S th: u G-401J fm r> -ojor.e Ga- Gas pressure regulatoi (except pinpane pas) Manual main gas shut-off valve -- AT20D Transfoi mer (except S.E ) Manual pilot gras shut-off valve where diaphragm gas valve is standard L62GB (24V.) o: CS591A (S.E.) combination pilot switch ami valve with auxiliary pilot valve; (100G shut-off) Drain valve -- Water heater opening cover plates ASME relief valve Pressuie and temperature gauge L400GA (24V and S.E.) immersion limit control Zone valve packages are avarlahle tot water boileis. For details ar.d prices, see page 33. Thermostats--see page 34 Ordering Example: Water boiler with standard equipment: J G--36-W boiler Nat gas 1000 Btu. 6 sg Other optional equipment (See page; 15. 16 and 18) See page 48 Page 7 For cc^pfete specifications refer to Technical Cats<c<; Bwiieim Form No 7?8*? (Rev 2 2 7t l HH-75*^ 07615 NON-PACKAGED BOILERS GAS FIRED STEAM ^AMERICAN ei STANDARD HYDRONIC HEATING G-40 GAS BOILERS--STEAM Deluxe jacket with buil^in draft hood. Regularly furnished for 115 volt, 60 cycle power supply with 24 volt control system (self energizing optional). 15 lbs. steam working pressure. Listed ratings for installation at sea level to 2,000 feet. STEAM--For Natural and Propane Gases--100% Shut-Off. For Built-In Water Heaters, see page 16. boiler number A.G.A. 1 Input | Mbh A.G.A. output Mbh ----------------------------1 not l = B = R rating Trade Price with Mbh q. ft. standard equipment lets thermostat pproi. hipping weight chimney site intide diem In. height teal G-403-S G-404-S G-40S-S G-406-S G-407-S G-408-S G-409-S G-4010-S G-4011-S G-4012-S G-4013-S G-4014-S 1 150 - 225 ! 300 ' 375 450 525 600 675 750 1 825 i 900 975 120 180 240 300 360 420 480 540 600 660 720 780 90.0 135.0 180.0 225.1 270.1 315.1 360.1 405 i 450.0 495.2 540 0 585.1 375 563 750 938 1125 1313 1500 1688 1875 2063 2250 2438 $ 603.00 750.00 897.00 1052.00 1207.00 1324.00 1472.00 1618.00 1767.00 1918.00 2066.00 2212.00 744 921 1117 1297 1475 1647 1820 1994 2219 2388 2557 2726 8 15 8 15 8 15 10 15 10 15 10 15 10 15 12 15 12 15 12 15 12 15 15 15 NOTE: Available as factory assembled sections in aii sizes ............................................................. Trade Price per section *11.00 Ordering Example- Steam boiler with optional equipment. 1 G-409-ST I No 226 tankless heater with controls Nat gas. 1000 Btu, .6 sg. Standard equipment V800A Combination Gas Valve: G-403 and G-404 for Natural Gas V800B Combination Gas Valve: G-403 thru G-40T for Propane Gas G-50AAG Combination Gas Valve: G-405 and G-406 foi Natuia! Gas V88A or B-S0 Diaphragm Gas Valve: G-407 thru G-4014 for Natural Gas G-408 thru G-4014 for Piopane Gas Gas pressure regulator (except propane gas) Manual main gas shut-off valve -- AT20D Transformer (except S.E.) Manual pilot gas shut-off valve where diaphragm gas valve is standard. L62GB (24V.) or CS5S1A (S.E.) combination pilot switch and valve with auxiliary pilot valves (lfiOIF shut-off) Drain valve -- Water heater opening cover plates ASME safety valve Steam gauge PA404A (24V. and S.E.) pressure limit control Gauge glass with trim No. 67-GAR (24V. and S.E.) low water cut-off Side outlet ASME steam safety valve available. No charge if spec ihed Thermostats--see page 34. Other optional equipment (See pages 15, 16 and 18) HH-75-1 See page 48 Pages For comoreie spec.licanons refer lo Tecrm.cal Catalog Bu'ieim Form No 72S-2 (Pev 2 2 71) 07616 AMERICAN SJ STANDARD HYDRONIC HEATING PACKAGED BOILERS GA* fired WATER ONLY GWP PACKAGED GAS BOILER (Single Boiler Installation) Completely assembled--pre-wired--forced circulation only--jacketed. Relief valve, temperature pressure gauge--draft hood included but shipped separately. 50 lbs. working pressure. Built-in air separator (patented "Eliminaire"). Regularly furnished for 115 volt, 60 cycle with 24 volt control system. Listed ratings for installations at sea level to 2,000 feet. WATER--100o shut-off--Natural and Propane Gas packaged boiler "umber* GWP-S GWP-6 GWP-7 AGA input Mbh 264 330 396 AGA output Mbh 211 2 264 0 316 8 not Iss8-t Mbh 183 5 229 6 275 7 chimney me intide d<a m height feet 7 15 8 15 8 15 approx thippmg weight 613 716 823 Trode Price with itandord e gut pm on ion fh#rmoot $580.00 701 00 835.00 Standard equipment Combination automatic gas valve Gas pressure regulator except propanej Manual main gas shut-off valve Manual pilot gas shut-off valve AT-20D transformer (except S.E.i Pilot Valve & Switch Dram Valve ASME Relief Valve Pressure-Temperature Gauge Deluxe Jacket L4080D Immersion Limit Control Draft Hood Drilled Port Burners are standard for natural gas. Ribbon Burners are standani for propane gas and optional for nat ural gas. Optional equipment Self Energizing controls No charge Zone Valve Packages are available (for details and prices see page 33.) Add suffix "R" to model number if ribbon burners are desired. Example: GWP-5R Optional constant circulation (24 volt) L4081B limit and reverse acting circulator controls ....................................................... Add Trade Price $13.85 Electronic Control Panel Systems, see page 18 for prices. For applica tion and details, contact American Standard. Sections tested for 100 psi working pressure Trade Price add per section $11.00 Thermostats--see page 34 See page'48 Page 9 Pot comoleie soeciticahons reier to Tecf^icat Catalog Buiieiin Porm No. 70205-2 (Rev. 12 70, HH-75-1 07617 NON-PACKAGED MODULAR GAS fired WATER ONLY rsi AMERICAN kd STANDARD hydronic heating GWM GAS MODULAR BOILER HOOK-UP (Modular Boiler Installations) The-GWM Modular Boiler Hook-up is a combination or multiple of five, six or seven section GWM boiler modules. Factory assembled sections with burners, pas manifold, and automatic pas valve mounted. Deluxe jacket, controls and draft hood are shipped separately. The patented "Ehminaire" is standard. Furnished for 115 volt. fiO cycle power supply with 24 volt control system. (Selfenergizing controls are not available). Tested and equipped for 50 PSIG workinp pressure. Indicated ratings are for installation at sea level to 2.000 ft. elevation. __ /ig'Qj \Sv'*y nrr GWM BOILER MODULES - Natural and Propane Gas: 100% Shut-Off. /**dwl* b'lf r Number* GWM-5 AGA npwl Mbh 264 AGA Du'Pwl Mbh 211.2 A*> l=l = R Mbh 183.5 GWM-6 330 264 0 229.6 GWM-7 396 316 S 275.7 Opproi. ih<ppng wtightt Ibi 629 735 846 Trod* Rric* ,ih ttonderd (qvipnruf lf)t hermOf S563.0Q 684.00 818 00 Standard equipment Combination automatic Gas Valve Gas pressure regulator (except propane) Manual Main Gas shut-off valve Manual pilot pas shut-off valve Transformer Relay R8227B Pilot valve and switch Drain Valve ASME Relief Valve(s) as required Pressure-Temperature Gaupe as required Deluxe Jacket L4080D Immersion Limit Cortio! Draft Hood Drilled Port Burners standard for natural pas. Ribbon burners standard for propane pas and optional foi natural pas. Optional equipment 1. Factory fabricated Water Manifold for Primary/Secondary circulation. Includes interconnecting supply piping (Boiler to manifold). Inieiconnecting return piping and circulator not included. . . Trade Price add per module S55.00 2. Factory fabricated Water Manifold for Parallel Boiler Hook-up In cludes interconnecting supply and return piping (boiler to manifold i Trade Price add per moduleSII1.00 3. Electronic Control Panel Systems, see page 18. For application and details, contact American Standard. 4. Sections tested for 100 psi working pressure. .................................................................... Trade Price add per section $11.00 Thermostats--see page 34. Add suffix "R" to module boiler number if ribbon burners are desired Example -- GWM-5R hh-75-1 See page 48 Pape 10 For co-D-ie'e speci'ica::on$ refer to Tec^'ca! Cai&'os Fo'rr> so 70269-2 <ev 12 7Q) 07618 ^AMERICAN laSTANDARD HYDRONIC HEATING NON-PACKAGED MODULAR GAS FIRED WATER ONLY GWM GAS MODULAR BOILER HOOK-UP (Modular Boiler Installations) The following: holier units in fm.OOO BTU input increment?* are achieved with module boiler combination*: MODULAR BOILER HOOK-UPS -- Natural and Propane Gas - 100% Shut-Off. gflit GWM-528 GWM-594 GWM-660 GWM-726 GWM-792 GWM-858 GWM-924 GWM-990 GWM-10S6 GWM-1122 GWM-1188 GWM-1254 GWM-1320 GWM-1386 GWM-1452 GWM-1S1B GWM-1584 G WM-1650 GWM-1716 GWM-1782 GWM-1848 GWM-1914 GWM-1980 GWM-2046 GWM-2112 GWM-2178 GWM-2244 GWM-2310 GWM-2376 GWM-2442 GWM-2508 GWM-2574 G WM-2640 GWM-2706 GWM-2772 GWM-2830 GWM-2904 GWM-2970 GWM-3036 GWM-3102 GWM-316B and upward See page 48 modular competition 5 IH1 2 1 _ -- 2 -- _ _ __ -- - _ -- - _ -- _ -- _ -- -- -- ~ _ -- - __ -- - -- 4 11(1 _ 1 2 -- 2 3 2 1 _ 3 4 3 2 1 _ 5 4 3 2 1 -- 5 4 3 2 1 -- 5 4 3 2 1 -- 5 4 3 2 1 7 *ct. _ _ 2 _ -- 2 3 1 2 3 4 - i 2 3 4 5 2 3 4 5 6 2 3 4 5 6 7 3 4 5 6 7 8 grots input Mbh 528 594 660 726 792 858 924 990 1056 1122 1188 1254 1320 i3e6 1452 1518 1534 1650 1716 1782 1843 1914 1980 2046 2112 2178 2244 2310 2376 2442 2508 2574 2640 2706 2772 2838 2904 2970 3036 3102 3168 grass output Mbh 422 4 475 2 528 0 580.8 633 6 686 4 739 2 792 0 844 8 897.6 950 4 1003 2 1056 0 1106 8 1161 6 1214 4 1267 2 1320 0 1372 8 1 425 6 1476 4 1531.2 1584 0 1636 0 1639 6 1742 4 1795 2 1848 0 1900.6 1953 6 2006 4 2059.2 2112 0 2164 8 2217.6 2270 4 2323 2 2376 0 2428 8 2461.6 2534.4 not output Mbh 367,0 413 9 459 1 504 3 551 3 596 5 643 5 688 7 733 9 780 9 626 1 873 0 918 3 963 5 1010 4 1055 7 1102 6 1147 8 1193 0 1240 0 1 285 2 1332 2 1375 4 1422 6 1467 0 1516 5 1561 7 1607.0 1652 2 1697.4 1746 1 1791 3 1836 5 1861 7 1927 0 1975.7 2020 9 2066 1 2111.3 2156.5 2205 2 opproi (hipping woight 1258 1364 1470 1581 1692 1993 2099 2205 2316 2427 2538 2S34 2940 3051 3162 3273 3384 3675 3786 3897 4008 4119 4230 4521 4632 4743 4854 4955 5076 5367 5478 5589 5700 5811 5922 6213 6324 6435 6546 6657 6768 Modular Operating Control Package Options 1. Four stage immersion type operating eontrul. (one required for up to 4 modules) Trade price add per control $95.00 2. Immersion type operating controls with individual outdoor resets. Trade price add per module $64.00 3. Eight stage boiler sequencing control panel system with outdoor- reset, (one required for up to 8 modules) Trade price add per control $363.00 4. Sections tested for 100 ppj working pressure. .....................................................................Trade Price add per section $11.00 Page 11 Scr coT.^iete specifications fete' t: Technical Caia'OQ Bulletin Fom No 7C28S'-2 'Re* i? "7C Trade with ttandord equipment lets thermostat S1107.00 122B.OO 1349.00 1483.00 1617.00 1771.00 1892.00 2013.00 2147.00 2281.00 2416.00 2556.00 2677.00 2812.00 2946.00 3080.00 3214.00 3342.00 3496.00 3630.00 3764 00 339e.OO 4033.00 4160.00 4294.00 4429.00 4563.00 4697.00 4831.00 4959.00 5093.00 5227.00 5361.00 5496.00 5630.00 5757.00 5692.00 6026.00 6160.00 6294.00 6428.00 HH-75- 07619 NON-PACKAGED SINGLE OR MODULAR--GAS FIRED WATER ONLY ^AMERICAN csiSTANDARD HYORONIC HEATING GW NON-PACKAGED GAS WATER (Single or Modular Boiler Installation!) The GW non-packaged boiler designed for forced circulation only. Factory assembled scrt:cr.r. Jackets, burners and manifolds shipped separately. Ir-cl-de.-. idicf \aive, tem perature-pressure gauge, and draft hood. The patented "Elinunaire" is standard. Boiler tested and equipped for 50 PSIG working pressure. Furnished for 115 volt, 60 cycle power supply with 24 volt controls. Self-energizing controls available at no addi tional cost. Ratings shown are for installations at sea level to 2000 ft. elevation. INDIVIDUAL BOILERS -- WATER -- 100% shut-off -- Natural and Propane Ga* chimney tixt bailer Avtnbtf* A G A. input Mb* A.G A. output MbH net 1=8=1 Mbh Intide dip. in. height feel GW-8 G W-9 GW-10 462 528 594 369 4 422.4 475.2 321.7 367.0 413.9 9 10 10 15 15 15 opprei. shipping raighl 938 1052 1177 Trade Price with ttondord equipment less thermostat $ 903.00 977.00 1051.00 MODULAR BOILERS - WATER - 100% ihut-off - Natural and Propane Gas unit number GW-924 GW-990 GW-10S6 GW-1122 GW-1188 GW-1386 GW-1452 GW-1518 GW-1584 GW-1650 GW-1716 GW-17B2 GW-1848 GW-1914 GW-1980 GW-2046 modular tempo*! ion .... 2 1 -- | * sect | 10 ted. !_ _ 1-- 2; -- 11 -- ;-- 3-- 21 12 2 -- _ -- --i 3: -- --; 2i 1 --! 1 2 --3 4 '-- -- 3! 1!-- 2 2-- ii3 -- groit input Mb* 924 990 1056 1122 1188 1386 1452 1518 1584 1650 1716 1782 1848 1914 1980 2046 grott output Mbh 739 792 845 898 950 1108 1162 1214 1267 1320 1373 1426 1478 1531 1584 1637 net output Mbh 644 689 734 781 826 964 1010 1056 1103 1148 1193 1240 1285 1332 1376 1423 appres. chipping woighlt Trode Price with s'ondo'd equipment leu thermostat 1876 1990 2104 2229 $1806.00 1880.00 1954.00 2027.00 2354 2814 2928 3042 2101.00 2709.00 2783.00 2857.00 3156 32B1 3406 3531 i 1 , | 2930.00 3004.00 3078.00 3152.00 3752 j 1 3866 3980 4094 | 3612.00 3686.00 3760.00 3B34.00 Standard equipment Combination automatic gas valve Pressure-Temperature Gauge Gas pressure regulator (except propane) Manual gas shut-off valve Manual pilot gas shut-off valve AT-20D Transformer (except SE) Pilot Valve and Switch Drain Valve L-4080D Immersion Limit Control Deluxe Jacket Draft Hood Drilled Port Burners standaid for natural gas. Ribbon Burners standard for propane gas and optional for ASME Relief Valve natural gas. Optional equipment Sections tested for 100 psi working pressure. ........................................................................... Trade Price add per sectior.S11.00 Self-energizing controls................... no charge Thermostats--see page 34. Electronic Control Panel System, see page 18. For application and de tails, contact American Standard. Modular Operating Control Package Options 1. Four stage immersion type operating control (one required for up to 4 modules) ........................................... Trade Price add per control $95.00 2. Immersion type operating controls with individual outdoor resets (one required for each module). Trade Price add per module S64.00 3. Eight stage boiler sequencing control package with outdoor reset (one required for up to 8 modules) . Trade Price add per control $363.00 Add suffix "R" to model number if ribbon burners are desired. Example: GW'-8-R HH-75-1 See page 48 Page 12 for complete speciiicaiions re'ef lo Tecnnicai Caia'pg Bu"e'<n Pcfm No 70289-2 iRtv 12 70) 07620 PS! AMERICAN iSiSTANDARD HYDRONIC HIATI NO NON-PACKAGED gas piped WATER G-10 GAS BOILERS -- AGA approved inputs 800 MBH to 6400 MBH. Single combustion chamber--jacketed. Available with built-in heaters for storage tank or tankless application. 50 lbs. water working pressure. Integral draft hood rear outlet--optional top outlet--natural gas only (except G-1010) available at no extra charge. Regularly furnished for 115 volt, 60 cycle power svstem with 9s vn!t controls. Listed ratings for installation ol sea ievei to 2,000 feet. __ WATER -- Natural Gat -- 100% Shut-Off. Por Built-In Water Heaters, tee page 17. belief number A.OJL input Mbh A.QJL output Mbh enotlwBwft piping and rating Mbh pick-up factor A ^Trade Price net rating with standard sq. ft weler leea thermostat approx. hipping weight chimney else Inside diem. In. ht ft G-105-W G-106-W G-107-W G-10B-W G-109-W G-1010-W G-1011-W G-1012-W G-1013-W G-1014-W G-1015-W G-1016-W G-1017-W G-1018-W G-1019-W G-1020-W G-1021-W G-1022-W G-1023-W G-1024-W G-1025-W G-1026-W G-1027-W G-1028-W G-1029-W G-1030-W G-1031-W G-1032-W G-1033-W 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 3200 3400 3600 3800 4000 4200 4400 4600 4800 5000 5200 5400 5600 5800 6000 6200 6400 640 800 960 1120 1280 1440 1600 1760 1920 2080 2240 2400 2560 2720 2880 3040 3200 3360 3520 3680 3840 4000 4160 4320 4480 4640 4800 4960 5120 556.5 695.7 834.8 973.9 1113.0 1252.2 1391.3 1530.4 1669.6 1808.7 1947.8 2087.0 2226.1 2365.2 2504.3 2643.5 2782.6 2921.7 3060.9 3200.0 3339.1 3478.3 3617.4 3756.5 3895.7 4034.8 4173.9 4313.0 4452.2 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15 3710 4638 5565 6493 7420 8348 9275 10203 11131 12058 12985 13913 14841 15768 16695 17623 18551 19478 20406 21333 22261 23189 24116 25043 25971 26899 27826 28753 29080 $ 1697.00 2067.00 2433.00 2824.00 3156.00 3493.00 3846.00 4293.00 4824.00 5212.00 5539.00 5880.00 6236.00 6611.00 7002.00 7327.00 7717.00 8058.00 8446.00 6803.00 9131.00 9521.00 9893.00 10160.00 10421.00 10826.00 11154.00 11480.00 11822.00 2706 3153 3627 4107 4584 5077 5568 6146 6659 7179 7752 8248 8744 9253 9765 10301 10778 11341 11851 12360 12891 13384 13876 14374 14878 15368 15891 16406 16936 14 14 14 16 16 18 18 20 20 22 22 22 22 24 24 24 26 26 26 26 28 28 28 28 30 30 30 30 30 20 20 20 20 20 20 20 20 20 20 20 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 * The net l=B = R rating* shown are baaed on tha factors shown in the pipmf and ptckup column. American-Standard should be consulted before selecting a boiler for installations having unusual piping and pickup requirements. Standard equipment V88A or B50D gas valve(s) Gas pressure regulator (except Propane gas) Manual main gas shut-off valve Manual pilot gas shut-off valve AT20D Transformer Ribbon type main burners ASME relief valve Drain valve Draft hood L62GB combination pilotstat and H17BA1 pilot valves Pressure and temperature gauge L4006A immersion limit control Thermostats--see page 34. Optional equipment 80 lbs. water test--Trade Price per section............................................... $11.00 Factory assembled sections thru G-1011 Trade Price per section $30.00 Other optional equipment: See pages 15. 17 and 18 Ordering Examples: 1. Water bailer. 1 61013 W bailer Net. p*. 1000 Btu, .6 if. G-10 GAS BOILERS -- WATER for Propane Gas Propane Gas Ratings are determined by reducing the Natural ratings above by 10%. Example: G-105-W A.G.A. input 800 less 10%=720 Mbh Input for Propane Gas. Detailed Propane Gas ratings are shown in current Technical Literature. Trade Prices, Chimney Sizes and shipping weights remain the same as shown above. See page 48 Page 13 For complt pecilictlion* r#fr to Technical Catalog BuMeim Form No. $$8-2 (Rev. 12/72) HH-75-1 07621 NON-PACKAGED GAS FIRED STEAM ,_|AMERICAN kSiSTANDARD HYDRONIC HEATING G-10 GAS BOILERS AGA approved inputs 800 MBH to 6400 MBH. Single combustion chamber--jacketed. Available with built-in heaters for storage tank or tankless application. 15 lbs. steam working pressure. Integral draft hood rear outlet--optional top outlet ratural gas only (except G-1010) available at no extra charge. Regularly furnished for 115 volt, 60 cycle power system with 24 volt controls. Listed lacings for installations at sea level to 2'000 feet. Factory-sections assembled thru G-1011 optional add Trade Price $23.00 per section. STEAM -- For Natural Gas -- 100% Shut-Off. For Built-In Water Heaters (G-105S thru G-I014S only) See pageT 7 boiler number A.G.A. Input Mbh A.G.A. output Mbh a net 1 = B s ft rating Mbh sq. ft. l=B=R piping and pick-up factor a Trada Rrlca with standard equipment lees thermostat approx. shipping weight chimney size inside dlam. in. ht. ft. G-105-S G-106-S G-107-S G-108-S G-109-S G-1010-S G-1011-S G-1012-S G-1013-S G-1014-S G-1015-S G-1016-S G-1017-S G-1018-S G-1019-S G-1020-S G-1021-S G-1022-S G-1023-S G-1024-S G-102S-S G-1026-S G-1027-S G-1028-S G-1029-S G-1030-S G-1031-S G-1032-S G-1033-S 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000 3200 3400 3600 3800 4000 4200 4400 4600 4800 5000 5200 5400 5600 5800 6000 6200 6400 640 800 960 1120 1280 1440 1600 1760 1920 2080 2240 2400 2560 2720 2880 3040 3200 3360 3520 3680 3840 4000 4160 4320 4480 4640 4800 4960 5120 480.1 600.1 720 2 840.2 962.4 1095.1 1227.9 1361.2 1489.5 1614.9 1739.1 1863.4 1987.6 2111.8 2236.0 2360.2 2484.5 2608.7 2732.9 2857.1 2981.4 3105.6 3229.8 3354.0 3478.3 3602.5 3726.7 3850.9 3975.2 2000 2501 3001 3501 4010 4563 5116 5672 6206 6729 7246 7764 8282 8799 9317 9834 10352 10870 11387 11905 12422 12940 13458 13975 14493 15010 15528 16046 16563 1.333 1.333 1.333 1.333 1.330 1.315 1.303 1.293 1.289 1.288 1.288 1.288 1.288 1.288 1.288 1.288 1.288 1.288 1.288 1.288 1.288 1.288 1.288 1.288 1.288 1.288 1.288 1.288 1.288 $ 1757.00 2126.00 2497.00 2688.00 3226.00 3552.00 3960.00 4422.00 4902.00 5290.00 5617.00 5958.00 6314.00 6749.00 7139.00 7466.00 7853.00 8195.00 8584.00 8942.00 9269.00 9657.00 10031.00 10295.00 10560.00 10964.00 11292.00 11617.00 11959.00 2706 3153 3627 4107 4584 5077 5568 6146 6659 7179 7752 8248 8744 9253 9765 10301 10778 11341 11851 12360 12891 13384 13876 14374 14878 15368 15891 16406 16936 14 14 14 16 16 18 18 20 20 22 22 22 22 24 24 24 26 26 26 26 28 28 28 28 30 30 30 30 30 20 20 20 20 20 20 20 20 20 20 20 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 A The net l = B = R ratings shown are bated on the factors shown m the piping and pickup column. American-Standard should be consulted before selecting a boiler for installations having unusual piping and pickup requirements. Standard equipment V88A or B50D gas valve (s) Gas pressure regulator (except propane gas) Manual main gas shut-ofT valve Manual pilot gas shut-olT valve AT20D Transformer AbMti salety valve Steam gauge Ribbon type main burners Optional equipment Factory assembled sections thru G-1011 Trade Price per section $30.00 Drain valve Draft hood L62GB combination pilotstat and H17BA1 pilot valves PA404A pressure limit control Gauge glass with trimmings No. 67AR Low Water cut-off Thermostats--see page 34. Side outlet ASME steam safety valve available. No charge if specified. Other optional equipment: (See pages 15, 17 and 18). Ordering Etsmplev. Sl*jm boiler with standard equipment 1 GI01S-S boiler Nat |av 1000 8tu. .$5 i| G-10 GAS BOILERS -- STEAM for Propane Gas Propane Gas Ratings are determined by reducing the Natural Gas ratings above by 10%. Example G-105-S A.G.A. Input 800 less 10%=720 Mbh Input for Propane Gas. Detailed Propane Gas ratings are shown in current G-10 Technical Literature. Trade Prices, Chimney Sizes and shipping weights remain the same as shown above. HH-75-1 ^ See page 48 Page 14 For complete epecilicetions reler to Technical Catalog Bulletin Form No 6M-J (Rev 12/7J) 07622 4SJSTANDARD MYORONIC HEATING miscellaneous options GAS BOILERS MISCELLANEOUS OPTIONS -- NON-PACKAGED GAS BOILERS G-2, G-40 AND G-10 BOILERS: '`IS" Equipment: boilers can be furnished for use with Indirect Steam Hot Water Supply Systems. L4006A im mersion operating control for use in storage tank is re quired and will be furnished when specified on order at extra Trade Price $16.90. This control operates gas valves on boiler electrically as required. No. 47-2 boiler water feeder and cut-off combination is available instead of the 67-AR with G-2, G-40 and G-105 thru G-108 steam boilers at additional Trade Price .$55.65 Low water cut-offs for water boilers: No. 63 cut-off for water working pressures of 50 lbs., or less. Trade Price .... $57.50 No. 150 cut-off for water working pressures in excess of 50 lbs. available when specified. Trade Price .................... $85.90 Try-cocks and lappings: for steam boiler to meet local code specify on order. Trade Price ............................................ $5.70 G-2 BOILERS: "DW" (Direct Water) equipment: In addition to water boilei standard equipment, page 6, includes pressure gauge. 31' lb. ASME relief valve, L4006A Aquastat for storage tank, tank thermometer, name and rating plate for 80 lbs. water working pressure. Specify boiler with "DW" equipment. Trade Price .............................................................................. $22.20 Floor shield for combustible flooring: Add suffix letter "C" to boiler number. Trade Price ............................................ $4.45 G-2 AND G-40 BOILERS: Self-energizing control: All size G-2 and G-40 for propane gas. AH G-2 and G-40 thru G-4010 for natural gas. Equip ment includes: S.E. gas valve, Q313A Thermopile Gen erator and a L4006 S.E. limit control (water boileis less heater) or an L8124B Triple Aquastat Relay (water boilers with heater) or a PA404A Pressuretrol (steam boilers less heater). For steam boilers with heater L4006A S.E. immersion operating control will be turnished in addition to the Pressuretrol. Furnished at no additional charge when specified on order. Special thermo stat required, for Trade Price, see page 34. No. 101-24V electric water feeder can be added to the No. 67-GAR low water cut-off regularly furnished with steam boilers to provide low water cut-off and feeder combina tion at additional Trade Price ........................................ $75.00 Zone circulator control for water boiler with tankless heat er and combination immersion control-relay: use one T822D $7.70 thermostat and one R845A $22.35 relay for second and/or third zone. Water flow regulators sized for tankless heater involved will be furnished with heater when specified on order to meet local Utility requirement. Trade Price per heater.......$4.45 G-40 AND G-10 BOILERS: No. 51-2 boiler water feeder and cut-off available instead of No. 67-AR regularly furnished with G-109 thru G-1033 steam boilers. Trade Price ................................................. $85.00 G-40 BOILERS: Boilers with Tankless Heaters: ware: (foi forced escala tion) and steam boilers. Heaters are limited to boiler sizes as shown in ratings table on next page. Specify heater and add suffix "T" to boiler number. G-10 BOILERS: Pilot filters for G-10 available at no additional charge when specified on order to meet local utility codes. G-10 Steam Boiler external water heater tappings in cover plates: maximum size Specify number of cover plates. Trade Price per tapping ........................................$S.70 G-10 Right End Section Steam Trim Tappings for pressure gauge and water column fittings or for auxiliary controls furnished as standard equipment at no additional charge. Modulating gas valve: the G-lf) boiler can be specified with the V4062/5055B gas valve for Hi-Lo-off operation. Valve permits adjustment of the Lo-fire operation down to a minimum of 20% of the boiler input. Operation of the valve should be controlled by a SPST operating control. Specify on order and add to the Trade Price of the boiler with regular equipment. G-105 thru 1018 ....................................................................$218.00 G-1019 thru 1033 ..................................................................$275.00 See page 48 Page 15 HH-75-1 07623 -K id TANKLESS HEATERS-GAS FIRED WATER AND STEAM I AMERICAN ei STANDARD HYDRONIC HEATINO G-2 TANKLESS HEATERS G-2 NON-PACKAGEO ALL PURPOSE BOILER: Fictory installed tankless heaters: When boilers (4 thru 11 section) are to be used for forced circulation. See table belc'.v for I=W=H rstir.g; ;r,d applicable boiler size. Specify heater, add suffijH'T" to boiler number and "factory installed." Add Trade Price shown. Ratings number A.C.A. Input tWhr. he2a11ter IbWh Aatlftf he2a2t2er M2a24tir N2e3a2ter G-24 G-25 90.000 120.000 2V, -- -- 3 -- -- -- -- G-26 GG-2278 GG--22910 G-211 150.000 180.000 210.000 240,000 270.000 300.000 -- -- -- -- -- -- 33V`4. 3 Vi 33 lV/?i 3 Vi -- 4 4'/, 4*v. '/. 4 Vi -- -- -- 4 Vi 4(4 5 G-2 PACKAGED AND NON-PACKAGED ALL-PURPOSE BOILERS: Tankless heaters: When boilers (4 thru 11 section) are to be used for forced circulation I=W = H tankless heaters can be installed in opening used for gravity tapping flange cover. See table for I=W = H ratings and applicable boiler size. Tankless heaters can be ordered shipped separately at the "sold separate" Trade Prices shown below. heater numbtr 218 222 226 232 Trade Prices factory installed $55.00 61.00 75.00 87.00 sold separata S32.00 39.00 53.00 65.00 L8124E for 24 Volt or L8124B for SE, Triple Aquastat Relay furnished with heater (packed in trim box). Water tlow regulator. Specify on order. Trade Price ... $4.45 G-40 TANKLESS HEATERS -- STEAM OR FORCED WATER BOILERS Ratings (Gallons per minute*) Trade Prices HEATEH NO. HEATER WITH CONTROLS Water StaaaC) HEATER ONLY Water ar SNmi 218 855.00 848.00 832.00 222 1.00 55.00 38 00 226 75.00 0.00 S3.00 232 87.00 81.00 5 00 4*5 105.00 M.00 13.00 460 113.00 108.00 81.00 Tankless heaters with controls (or water boilers: L8124E combination immersion control-relay packed in trim box in place of standard limit control. $4.45 Tankless heaters with controls lor steam boilers: L4006A immersion operating control packed in trim box in addi tion to PA404A pressure limit control. $16.90 Water flow regulator. Specify on order. Added Trade Price ........................................................................................................ (1) Additional L4006A operating control required for steam boiler-heater combinations shown shaded. Add to above heater w/control Trade Price ............................ G-40 F.M. or F.I.A. ooulpmont F.I.A. requires tpocial train PLUS F.I.A. electronic panol F.M. & F.I.A. GAS CONTROL EQUIPMENT (GAS TRAIN ONLY) BOILER NUMBER ADO TO BOILER TRADE PRICE W F.M.(') F.l A.H G-403 thru G-4014 $112.00 $589.00 *i> F M gas control equipment includes two manual shut*oM valves, a test vent valve and one AH2/V710 Hydromotor Valve '! F l A. gas control equipment includes two manual snut-oH valves, hi and LO o'essure switches, two AH2/V71Q Hydromotor Valves and a vent valve Note: A low water cut-ofF for water boilers (50 lb. or 80 lb. water working pressure) will be furnished as required. No. 63 ............................................................ Trade Price 157.50 No. 150 ......................................................... Trade Price $85.90 Boiler HEATER 218 HEATER 222 HEATER 226 HEATER 232 HEATER 445 HEATER 460 Steam Water Steam Water Steam Water Steam Water Steem Water . Steam . Water HH-75-1 See page 48 Page 16 07624 AMERICAN brJSTANDARD HTORONIC HEATING tankless heaters-gas fired WATER AND STEAM G-10 BOILERS -- TANKLESS OR TANK TYPE HEATER No. 1023 heater is available in any quantity. Specify number required. Trade Price each $45.40 G-10 F.M or F.l A. quipmenl F.l A' require, ,oeciei gas train PLUS F i A electronic nanet The ratings table un Ibis page shows the ratings attained if more than one heaterisconnected in parallel. Copper pipe manifolds, factory assembled for multiple heater parallel hookup, shipped in boxes of 2 manifold assemblies per box, when specified with heaters, are avail able at the following charges: Manifold Assembly Two Heater Three Heater Four Heater Trade Price $9.85 514.95 $18.75 All G-10 water boilers and sizes G-105S thru G-1014S steam boilers can be provided with sections for insertion of heaters at no extra charge, add suffix letter T to boiler number and specify the number of sections with heater openings. Cover plates to close unused water heater openings will be furnished only if specified on order at Trade Price each ..................................................................... $6.05 When specified, the G-10 water boiler with heater can be provided with the combination L8124E in place of the L4006A limit control. Trade Price ............................... $22.00 F.M. A F.l.A. GAS CONTROL EQUIPMENT (GAS TRAIN ONLY) ADO TO BOILER TRADE PRICE BOILER NUMBER G-105 thru G-106 G-107 G-108 thru G-1011 G-1012 thru G-1017 G-1018 G-1019 thru G-1030 G-1031 thru G-1033 FU.C) 5 98.00 115.00 101.00 164.00 221.00 229.00 294.00 F.I.A.O SS91.00 637.00 770.00 878.00 957.00 1019.00 1185.00 F.M. gas control squioment includes two manual shut-ofi valves, a test vent valve and one AH2/V710 Hydromotor Valve '2' F.l.A gas control equipment includes two manual shul-olf valves. Hi and 10 pressure switches, two AH2/V710 Hydromotor Vsives and a vent ve've When No. 1023 heaters are used in steam boilers, the L4006A operating control will be required for installation in a heater tapping. Trade Price .................................. $16.90 When the NTo. 1023 heaters are used in a storage type domestic hot water system, the L4006A operating control will be required for insertion in a storage tank. Trade Price ............................................................................................$16.90 NO. 1023 HEATER RATINGS TANKLESS APPLICATION boiler number no. of tankless heaters intermittent draw heater rating gpm @ 100 rise pressure drop (with manifolds) PSI G-105 - G-1033 G-105 - G-1033 G-106 - G-1033 G-108 - G-1033 1 2 3 4 41/4 7Vz 10 12 3/ NOTE: Heaters for Steam Boilers available 5 thru 14 sections only. 19 14 12 11 STORAGE TANK APPLICATION boiler number number of boaters continuous draw 100 rise ipm recovery capacity 100 rise gph boiler output required mbh G-105 - G-1033 G-105 - G-1033 G-106 - G-1033* G-108 - G-1033 G-lOll - G-1033 G-1013 G-1033 G-1014 - G-1033 G-1016 - G-1033 G-1018 - G-1033 G-1020 - G-1033 G-1022 - G-1033 G-1024 - G-1033 1 2 3 4 5 6 7 8 9 10 11 12 4 240 200 7 420 350 10 600 500 13 780 650 16 960 800 19 1.140 950 22 1.320 1,100 25 1,500 1,250 28 1.680 1,400 31 1.860 1,550 34 2.060 1.700 37 2.220 1.850 NOTE: Hatters for Steam Boilers available 5 thru 14 sections only. storage tank size gale. 500 500 500 1,000 1,000 1,000 1.500 1,500 1.500 2,000 2,000 2,000 See page 48 Page 17 HH-75-1 07625 ELECTRONIC CONTROLS .AMERICAN kSJ STANDARD hyoronic heating GAS BOILER ELECTRONIC CONTROL PANEL SYSTEMS -- (FOR IIS VOIT. 40 CYCLE 1 PHASE POWER ONLY) Panel System EPG-M: Provides manual ignition, 1009c safety shut-off with electronic supervision of pilots 1 to 3. Main burners and pilots are turned off on pilot failure. Continuous flame pilot operation. Equipment includes: one panel for each electronic pilot (Main panel plus 1 or 2 auxiliary panels) prewired and factory assembled; Baso valves and thermocouples and Q-179B electronic flame rod and pilot; RA890F protectorelay installed on panel; 3 ft. flame rod wire per pilot. Panel System EPG-ES: Provides electronic supervision of each pilot (1 to 3) and interrupted continuous burning pilot electronically turned off and electrically relighted on every cycle to achieve positive component check of relays and pilot system. Complete automatic operation of boiler. 100% safety shut-off. Equipment includes: one panel for each electronic pilot (Main panel plus 1 or 2 auxiliary panels) prewired and factory assembled; Q179A flame rod and electric ignition pilots; ignition transformer; V4046C pilot solenoid valves; RA890F protectorelay installed in panels with 2-4 seconds response timing and alarm con tacts; minimum of 3 ft. of flame rod wire and 3 ft. of ignition cable per pilot. Panel System EPG-E: Provides electronic supervision of each pilot (l to 3) and intermittent electric ignition of all pilots. Complete automatic operation of boiler. 100% safety shut-off. Equipment includes: one panel for each electronic pilot (Main panel plus 1 or 2 auxiliary panels) prewired and factory assembled; Q179A flame rod and electric ignition pilots; ignition transformer; V4046C pilot solenoid valves; RA890F protectorelay installed in panel with 2-4 seconds response timing and alarm contacts; minimum of 3 ft. of flame rod wire and 3 ft. of ignition cable per pilot. Panel System EPG-M(FIA): Specifically designed to meet FIA requirements. Provides constant burning manually lighted electronically supervised pilots (1 to 3). 100% safety shut-off. Equipment includes: one panel for each electronic pilot (Main panel plus 1 or 2 auxiliary panels) prewired and factory assembled; alarm bell, alarm silencing switch; purge timer, all factory assembled in master panel; RA 890F protectorelay installed in panel; Baso valves and thermocouples and Q-179B electronic flame rod pilot; 3 ft. flame rod wire per pilot. ADDITIONAL CHARGES-^-Trade Price Specify on order type of system desired, as described above, and add charge for boiler size involved to Trade Price of boiler with regular equipment. PANEL SYSTEMS EPG-M boiler no. system no. GW. U-40 EPG-M1 G-105 thru G-1012 EPG-M1 G-1013 thru G-1023 EPG-M2 G-1024 thru G-1033 EPG-M3 added eharpe (1) $250.00 250.00 480.00 718.00 PANEL SYSTEMS EPG-E boiler no. system no. GW. G-40 EPG-E1 G-105 thru G-1012 EPG-E1 G-1013 thru G-1023 EPG-E2 G-1024 thru G-1033 EPG-E3 added charge (t) $276.00 276.00 508.00 762.00 PANEL SYSTEMS EPG-ES boilor no. system no. edded charge (1) GW, G-40 EPG-ES1 $329.00 G-105 thru G-1012 EPG-ES1 329.00 G-1013 thru G-1023 EPG-ES2 561.00 G-1024 thru G-1033 EPG-E S3 817.00 PANEL SYSTEMS EPG-M(FIA) bolter no. system no. added charge GW, G-40 EPG-MI(FIA) $455.00 G-105 thru G-1012 EPG-MI(FIA) 455.00 G-1013 thru G-1023 EPG-M2(FIA) 696.00 G-1024 thru G-1033 EPG-M3(FIA> 946.00 Flame Rod Wire: Trade Price per foot.............. Ignition Cable: Trade Price per foot .......... $ .50 $1.05 <'> Not*. i purge timer n desired, specify on order end add $75.00 Trede Price 'Trade prices apply to equipment when shipped with boiler. For field conversions, price on application. HH-75-1 See page 48 Page 18 07626 rWlAMtKIUMN kJ STANDARD HYDRONIC HEATING PACKAGED BOILER-BURNER UNITS WATER ONLY DP (T)-95/105 PACKAGED BOILER-BURNER UNITS Bsilcr-burnsr unit, dry base design--with DH-F flame retention burner (J.725 KPM). Nozzles-for two firing rates provided. Furnished with controls for forced circulation. Tested and equipped for 30 lbs. water working pressure. 115/60/1 electrical charac teristics. WATER packaged unit number groaa l=B=R output mbh l=B=R burner capacity gpi> lanklatt heatar number tankleaa heater capacity gpm nat l=6 = R rating mbh nat rating aq. ft. wattr Trad# Pr.ca with atandard aquipmant approi. hipping weight neola ams Packaged unite with factory installed tankless heater with R-8182D Aquastat-relay combination, high limit, low limit and circulator control, light sensing primary control. DPT-9S DPT-105 95 105 .90 1.00 218 218 3 82.6 550 $686.00 496 .90-80`S and 3 91.3 608 686.00 496 1 00-80`S Packaged unit* lea* tankless heater with L4080B Aquastat limit contiol, and separate R8184G light sensing primary control. DP-95 95 .90 -- DP-105 105 1 00 -- 82.6 550 $636.00 91.3 608 636.00 Gallons of water per minute from 4Q*F to 140*F with 200eF boiler water temperature NOTE. Water volume 9.6 gallons. 481 481 .90-80`S and 1 00-80`S Standard equipment: Model DH-F Arcoflame oil burner with sling mounting cad cell, bracket and leads. T822D thermostat. Light weight fire brick combustion chamber. Nozzles--Two (high firing and low fir ing rate) each boiler. Draft regulator. ASME relief valve. Pressure and temperature gauge. circulator and piping. Wiring harness. Drain valve. Optional equipment: Two-stage fuel unit for DH-F oil burn er. Specify on order. Trade Price... S8.30 Ordtring Examples: ,1. Pockaged unit with heoltr with stondord equipment: 1 DPT'95 boiler-burner unit 2. Pockaged unit less heofer with standard equipment: I DP-95 bailer-burner unit W" See page 48 Page 19 For complete specification* refer to Technical Catalog Bulletin Form No. 72131*2 (6/72> HH-75-1 07627 PACKAGED boiler-burner units WATER ONLY ^AMERICAN fiJSTANDARD HYDRONIC HEATING VP(T) PACKAGED BOILER-BURNER UNITS Boiler-burner unit--wet base design--with DH-F flame retention burner (1725 RPM). Nozries for multiple firing rates provided. Furnished with controls for forced circula tion. Tested and equipped for 30 Its. water working pressure, lio/60/i electrical characteristics. WATER No. Sactiona packaged untt number grou l=0=A output mbh l=8=fl burner capacity gpb ton Mot* beeter number tankless heater capacity gpm not IsBsft rating mbh net rating aq. ft. water Trade Price with standard equipment appro s. Nipping weight water volume (Bel.) noate txaa Packaged unit* with factory Installed tankless heater W`.th R8l82D Aquastat-relay combination, high limit low limit *9 and circulator control, light sensing primary control. VPT-115 115 1.05 130 315 100.0 667 $ 737.00 575 15.6 1.00-80 Hago ES and 3 VPT-130 130 1.15 130 3V5 113.0 753 737.00 575 15.6 1.10-80' Hago ES VPT-140 140 1.25 130 3 Vz 122.0 814 737.00 575 15.6 1.25-80' Hago ES 4 VPT-170 170 1.50 131 4V 147.8 985 890.00 685 20.0 1.50-80' Hago ES and VPT-190 190 1.70 131 4V 165.2 1102 890.00 685 20.0 1.65-80' Delevan B VPT-230 230 2.05 132 6 200.0 1333 1004.00 795 24.4 2 00-70' Monarch R 5 and VPT-250 250 2.25 132 6 217.4 1449 1004.00 795 24 4 2 25-70" Monarch R Packaged units lest tankless heater With R8182F Aquastat-relay combination, limit and circulator control, light sensing primary control, one heater opening cover plate. - vp-rts--- 115 1.05 100.0 667 * 686.00 560 15.6 1 00-80 Hago ES and 3 VP-130 130 1.15 -- -- 113.0 753 686.00 560 15.6 1,10-80 Hago ES VP-140 140 1.25 122.0 814 686.00 575 15.6 1.25-80 Hago ES VP-170 170 1.50 -- -- 147.8 985 838.00 670 20.0 1.50-80 Hago ES 4 and VP-190 190 1.70 -- -- 165.2 1102 838.00 670 20.0 1.65-80 Delevan B VP-230 230 2.05 -- -- 200.0 1333 926.00 780 24 4 2.00-70 Monarch R 5 and VP-250 250 2.25 217.4 1449 926.00 780 24.4 2.25-70" Monarch R 'Gallons of water per minute Irom 40F to 140'F with 200*F boiler water temperature. Standard equipment: Model DH-F Arcoflame oil burner with sling mounting cad cell, bracket and leads. T822D thermostat. Pre-cast refractory combustion target wall. Draft regulator. ASME relief valve. Pressure and temperature gauge. H4" circulator with piping. Wiring harness. Drain valve. Ordering ExompUt: 1. Pockoged unit with heater with standard equipment: 1 VPT-1 15 boiler-burner unit 2. Packaged unit less healer with standard equipment: 1 VP-M5 boiler-burner unit Optional equipment: Zone valve packages are available for water boilers. For details and prices, see page 33. Two stage fuel unit for DH-F oil burn er--specify on order. Trade Price... *8.30 Jacket extension. Trade Price...... $35.00 R-8182-D Aquastat relay combination for use with tankless coils for conver sion of boiler without tankless heater. Trade Price add ..................................*7.70 For tankless heatev information, see page 23. HH-75-1 See page 48 Page 20 for complete specification* refer 10 Technical Catalog Bulletin Form No 7263-2 (Rev 8-'74| 07628 _ AMERICAN 5J STANDARD HYDRONIC HfATING NON-PACKAGED BOILER-BURNER UNITS WATER AND STEAM V-3 NON-PACKAGED ALL-PURPOSE BOILER-BURNER UNITS Boiler-burner unit--wet base design--with DH-F flame retention burner (1725 RPM). Sections assembled--nozzles for two firing rates provided. Flexible for steam, water, forced or gravity circulation--with or without tankless heater. 30 lbs. water working lbs. steam. 115 volt, 60 cycle, single stage electrical characteristics. WATER WBT Forced circulation units with factory Installed tankless heater include R8182D aquastat-relay combination, high limit, low limit and circulator control, light sensing primary control. WB Forced circulation units less heater include R8182F aquastat combination, limit and circulator control, light sensing pri mary control. Section Desgnatior bolter burner unit number groat 1=0=* output mbh 1=0=0 burner capacity gph tankleaa heater number Unkless heater rating gpm net l = 0=ft rating mbh r Trade Price tirade Price net standard standard rating aquipmant equipment ataam leas with sq. ft tankleaa tankleaa approk. shipping weight node used V-33 V3-116WB(T) V3-128WBfri 116 128 1.05 1.15 222 222 4 4 4K V3-172WB(T) 172 1.55 226 5 V3-186WBfT1 186 1.70 226 5 4 V3-228WB(T) 228 2.10 232 7 V3-244WBfTf 244 2.25 232 7 V3-284WB(T) 284 2.60 445 8'/4 V-36 V3-302WB(T) 302 2.80 445 8'/4 100.9 111.3 149.6 161.7 198.3 212.2 247.0 262.6 ___ $ 613.00 -- 613.00 -- 789.00 -- 789.00 -- 957.00 -- 957.00 -- 1112.00 -- 1112.00 t 656.00 656.00 846.00 846.00 1026.00 1026.00 1199.00 1199.00 613 613 790 790 967 967 1144 1144 1 00-80* Hago ES 1.10-80* Haoo ES 1.50-80" Hago ES 1 65-70" Haoo ES 2.00-70' Monarch R 2 25-70* Monarch R 2.50-70 Delevan B 2.75-60' Delevan B WBG Gravity units less heater includes L4080B aquastat limit control, and separate R8184G light sensing primary control. V3-116WBG V3-126WBG 116 1.05 128 1.15 _ _ _ 100.9 _ 607.00 Not Avail. 613 1.00-80* Hago ES -- 111.3 -- 607.00 Not Avail. 613 1 10-80* Haoo ES V-34 V3-172WBG V3-186WBG 172 1.55 186 1.70 V3-228WBG 228 2.10 T V3-244WBG 244 2.25 V3-284WBG V-36 V3-302WBG 284 302 2.60 2.60 --_ _ _ _ -- _-- 149.6 161.7 --_ 783.00 Not Avail. 763.00 Not Avail. 790 790 1.50-80' Hago ES 1 65-70* Haao ES -- 198.3 -- 952.00 Not Avail. 967 2.00-709 Monarch R -- _ 212.2 247.0 -- 952.00 -- 1107.00 Not Avail. Not Avail. 967 1144 2.25-70c Monarch R 2.50-70* Delevan B -- 262.6 -- 1107.00 Not Avail. 1144 2.75-60" Delevan B STEAM SBT Steam units with factory installed tankless heater includes PA404A Pressuretrol, L4006A aquastat operating control, ana separate R8184G light sensing primary control. SB Steam units less heater include PA404A Pressuretrol, and separate R8184G light sensing primary control. V-33 V-34 V-36 V3-116S8(T) V3-128SBfT1 V3-172SB(T) V3-1B6SBfn V3-228SB(T) V3-244SBfT) V3-284SB(T) V3-302SB(T) 116 128 172 166 228 244 284 302 1.05 222 4'/i 1.15 222 4% 1.55 226 5 V* 1.70 226 5 Vi 2.10 232 6% 2 25 232 6 Vi 2.60 445 7 y. 2.80 445 7 Vi 87.1 363 607.00 96.0 400 607.00 129.1 538 763.00 139.4 591 7B3.00 171.1 713 952.00 183.1 763 952.00 213.1 888 1107.00 226 6 944 1107.00 548.00 548.00 708.00 708.00 857.00 857.00 1000.00 1000.00 613 613 790 790 967 967 1144 1144 1 00-80' Hago ES 1.10-80' Haoo ES 1.50-80 Hago ES 1 65-70* Haoo ES 2.00-70 Monarch R 2.25-70* Monarch R 2 50-70* Delevan B 2.75-60* Delevan B A Gallons of water per minute heated from 40*F to 140*F with 200*F boiler water temperature. W See page 48 Standard equipment: Model DH-F Arcoflame oil burner sling mounting, cad cell, bracket and leads. T822D thermostat. Pre-cast refractory combustion target wall. Draft regulator. Drain valve. Units WITH water heater: 1 cover plate with control tapping. Units LESS heater: 2 cover plates for heater openings. Wafer: ASME relief valve. Pressure and temperature gauge. Steam: ASME safety valve. Steam gauge. Gauge glass with trimmings. Ordering Examples: 1. All-Purpose boiler-burner unit with standard equipment: For forced circulation, with heater: 1 V3-116/128WBT boiler-burner unit For gravity circulation: 1 V3-172/186WBG boiler-burner unit 2. All-Purpose boiler-burner unit with optional equipment: For forced circulation, less heater: 1 V3-228/244WB boiler-burner unit with stage fuel unit. Optional equipment: Zone valve packages are available for water boilers. For details and prices, see page 33. Others--see page 23. Page 21 For complete specifications refer to Technical Catalog Bulletin Form No. 73-166*2 (6/73) HH-75-1 07629 NON-PACKAGED OIL FIRED BOILERS WATER AND STEAM ^AMERICAN L5d STANDARD HYDRONIC HEATING V-3M ALL-PURPOSE OIL FIRED BOILERS The non-packaged all-purpose boiler only, with sections factory assembled, tested and equipped for 30 psi working pressure for water, 15 psi steam. WATER WT--Forced circulation boiler only with factory installed tankless heater. W--Forced circulation boiler only less healer. Section Designation boiler number V-34M V-36M V3M-92W(T) V3M-110Wfn V3M-138W(T) V3M-1S6Wm V3M-184W(T) V3M-202Wfn V3M-230W(T) V3M-248W(T) grota l=B=* output mbh 92 110 138 156 184 202 230 248 IsBsft burner capacity gbh .85 1 00 1.30 1 45 1.70 1.90 2.15 2 35 tankleaa heater number 222 222 226 226 232 232 445 445 tankleaa heater rating gpm 4 4 5 5 6 6 7 7 net |=B=R rating mbh 80.0 95.7 120.0 135.7 160.0 175.7 200.9 215.7 Trade Price standard equip. lets tankleaa heatar $327.00 327.00 437.00 437.00 560.00 560.00 664.00 664.00 Trade Price standard equip, with tankleaa heatar $355.00 355.00 478.00 478.00 610.00 610.00 729.00 729.00 approx. shipping weight aection saa'y 613 613 790 790 967 967 1144 1144 STEAM ST--Steam boiler only with factory installed tankless heater. S--Steam boiler only. Section Designation belter number 8 roes i=b=r output mbh l=BsR burner capacity gbh tankleaa heater number tankless healer rating gpm net 1= B -- R rating mbh net 'W Trid. Pries ^ Trade Price l=B = R standard equip, tandard*equip. aq. ft. less lankiest with tankleaa steam heater heatar V.11M V3M-92S(T) V3M-110S(T1 92 110 .85 1 00 222 222 4 4 69.0 82.5 288 344 V-34M V3M-138S(T) V3M-156Sm 138 156 1.30 1.45 226 226 5 103.5 431 5 117.0 489 v*j3 nn V3M-184S(T) V3M-202Sm 184 202 1.70 1.90 232 232 6 138.0 575 6 151.5 631 V3M-230S(T) 230 2.15 445 7 173.3 722 V3M-248S(T) 248 2.35 445 7 186.0 775 327.00 437.00 437.00 560.00 560.00 664.00 664.00 355.00 478.00 478.00 610.00 610.00 729.00 729.00 A Gallons of water oer minute heated from 40*F to 140*F with 200*F boiler water temoerature. Only oil burners capable of developing 10^> CO,, such is the OH-5 burner, may be used wun V-3M oil fired boiler*. approx. shipping weight section tta'y 613 613 790 790 967 967 1144 1144 HH-75-1 'V See page 48 Standard equipment: Pre-cast refractory combustion chamber. Drain valve. Water: ASME relief valve. Pressure and temperature gauge. Steam: ASME safety valve. Steam gauge. Gauge glass with trimmings. Optional equipment: See page 23. Note: Boilers with factory installed tankless heater are shipped with one water heater opening.cover plate with control tap ping. Boilers less factory installed heatei are shipped with an additional water heater opening cover plate (blank). Zone valve packages are available for water boilers. For details and prices, see page 33. Ordering Examples: 1. Water boiler less heater with standard equip ment: 1 V3M-92/110W boiler 2. Steam boiler with heater with standard equip ment: 1 V3M-138/156ST boiler 3. Water boiler with heater with optional equip ment: 1 V3M-230/248WT boiler with jacket ex tension Page 22 For complete specifications refer to Technical Catalog Bulletin Form No 73-166-2 (6/73} 07630 i a w \jvtl_f\IN-rVIN SiSTANDARD HYDRONIC HEATING OPTIONAL EQUIPMENT OIL FIRED BOILERS OPTIONAL EQUIPMENT VP(T) PACKAGED BOILER-BURNER UNITS V-3 NON-PACKAGED BOILER-BURNER UNITS V-3M NON-PACKAGED BOILER ONLY JACKET EXTENSIONS V-3 and V-3M jacket extension provides 17 Ai" acoustical enclosure in front for concealment of oil burner and con trols--specify on order. Trade Price Add .................$50.60 LOW WATER CUT-OFF--McDonald ti Miller No. 67AR low water fuel cut-off. Trade Price .....................................$43.00 Controls and control sets are shown on page 31. MISC. V-3 BOILER-BURNER UNITS Two-stage fuel unit. Trade Price ................................... $8.30 Order R8182D Aquastat-relay combination to permit use of tankless heater with boiler-burner units furnished less water heater. Trade Price ............................................... $7.70 Order R8182E Aquastat-relay combination to provide room thermostat control of circulator. Trade Price.... $6.00 FOR V-3 ALL-PURPOSE AND VP(T) BOILER-BURNER UNITS For substitution of No. 4 control set consisting of T822D thermostat, L4081B Aquastat limit and circulator control, plus R8184G light sensing primary control, instead of R8182F combination control, for non-packaged boilerburner units for forced circulationLESS heater. Added Trade Price .......................................................................... $15.30 For substitution of No. 5 control set consisting of T822D thermostat, L8124C Aquastat, limit, reverse and operating control, circulator relay, plus R8184G light sensing pri mary control, instead of R8I82D combination control, for non-packaged boiler-burner units for forced circulation WITH tankless heater. AddedTrade Price ................. $6.05 The No. 5Z Control Set can be used for circulator zoning with boiler-burner units with tankless heater. 1 No. 5Z set is required for each zone in addition to the first zone which is controlled by the No. 5 Control Set or equivalent. Added Trade Price ......................................................... $30.05 TANKLESS HEATERS FOR V-3, V-3M AND VP BOILERS Heaters can be ordered for separate shipment for use with units or boilers specified less heater as follows: RATINGS--Gallons ol water per minute from 40'F to 140`F with 200'F boiler water temp. boiler number HEATER 222 HEATER 226 HEATER 232 HEATER 445 HEATER 130 HEATER 131 HEATER 132 Steem Water Steam Water Steem Weter Steem Weter Steem Water Steam Water Steam Water V3-116/128 4Va 4% V3-172/186 4 y4 4% V3-228/244 4 V4 4% V3-284/302 41/4 4% V3M-92/110 4 41/2 V3M-138/156 4 41/2 V3M-184/202 4 4'/2 V3M-230/248 4 41/2 VP.-115/130/140 -- -- VP-170/190 _-- VP-230/250 51/4 5% 51/4 5% 5'/4 5% 5 51/2 5 51/2 5 51/2 -- -- -- -- 61/4 7 61/4 7 6 6% 6 6% ---- ---- 71/4 8V4 7 7% ---- ---- --- --- --- --- -- 31/2 -- 3'/2 -- 31/2 ---- -- -- -- -- -- 4 ye -- 4% ---- ---- -- -- ---- --6 Note: Because of unique boiler design a second heater may be installed in V3 and V3M water boilers which will increase the intermittent draw rating. * Appropriate controls must be ordered in addition to heater only above. Trade Price* HEATER HEATER ONLY NUMBER Wtr A Stum 222 $39.00 226 53.00 232 65.00 445 83.00 130 43.00 131 43.00 132 69.00 See page 48 Page 23 HH-75-1 07631 NON-PACKAGED PRESSURE FIRED BOILER-BURNER UNITS WATER AND STEAM fZJAMERICAN SJ STANDARD HYDRONIC HEATING PFA-3 PRESSURE FIRED BOILER-BURNER UNITS Jacketed--forced draft with flame retention oil burner. Sealed sections--with or without tankless heaters. 50 lbs. water working prpseuvA, 15 lh<5 steam _ 115 volt, 60 cycle power supply. WATER burner unit bumbar in. ewtewt MM e la|sk burner cs^Blty task!** number t IsWuH rating Ml ln|s| rating MM net rotinf . ft. meter Trade We# with standard equipment naprei. ihleeinf weight rent site dtom. In. Forced circulation units with factory Installed tankless heater : No. 5 control set -- T8220 thermostat, L0124C Aouastat. reverse and operating control, circulator relay, R0184G light sensing primary control. PFA-34- WT PFA-35-WT PFA-36-WT PFA-37-WT 300 375 450 526 2.65 226 6.0 260.9 1739 $1234.00 3.30 232 7.5 326.1 2174 1396.00 3.95 445 9.0 391.3 2609 1563.00 4.60 445 9.0 457.4 3049 1713.00 905 1096 1287 1481 8 8 8 8 Forced circulation units less heiter: No, 4 control set -- T822D thermostat, L4081B Aquastat limit ana circulator control. RS104G light sensing primary control. PFA-34-W P FA-35-W PFA-36-W PFA-37-W 300 2.65 375 3.30 450 3.95 526 4.60 260.9 326.1 391.3 457.4 1739 2174 2609 3049 51167.00 1316.00 1466.00 1617.00 894 1085 1276 1470 8 a 8 8 STEAM bailer. burner vmi number (nil i = a=t output Mbh i = a= burner capacity 04* twtkleis hearer number IsWsH rating mi 1 = 1=1 rating MM net ! = B=t q. ft. ifearn *W Trade Price with standard equipment epprex. ihipaing weigh* vent rite di'am. in. Steam units with actory installed tankless heater: No. 2 control set -- T022O thermostat. PA4Q4A Pressuretroi. L4006A Aquastat operating control, R81B4G light sensing primary control. PFA-34-ST 300 2.65 226 6.0 225.1 938 $1231.00 90S 8 PFA-35-ST 375 3.30 232 7.5 281.3 1172 1393.00 1096 8 PFA-36-ST 450 3.95 445 9.0 337.6 1407 1560.00 1287 8 PFA-37-ST 526 4 60 445 9.0 394.6 1644 1710.00 1481 8 Steam units less neater: No. 1 control set--T8220 thermostat. PA404A Pressuretroi. R8184G light sensing primary control PFA-34-S PFA-35-S PFA-36-S PFA-37-S 300 2.65 375 3 30 450 3.95 526 4.60 225.1 281.3 337.6 394.6 938 1172 1407 1644 $1161.00 1313.00 1460.00 1611.00 900 1091 1282 1476 8 8 8 8 'Nozzle sues furnished with the above units: (S -- solid; M -- hollow) PFA-34. 2.50 gph 70* S. PFA-35 3.25 gph 45* S' PFA 36. 4.00 gph 45* S; PFA-37. 4 50 gph 30* S tGaMons of water per minute heated from 40*F to t40`F with 200*F boiler water temperature. Vent needs to extend 3 feet above highest part of roof. Start-up service -price on application. Standard Equipment Water: ASME relief valve Pressure and temperature gauge Flange mounted oil burner with 2-stage fuel unit; factory installed light sensing cad cell with bracket and leads: V4046B instantaneous oil valve; Syracuse elec tronic time delay; drain valve. buiUr-bumur nit PFA-34 PFA-35 il burner LC-334-A3 LC334-A boiler-burner unit PFA-36) PFA-37 ( oil burner LC-534-A Units WITH water heater: 1 cover plate with %" control tapping. Units LESS water heater; 2 cover plates for heater openings. Steam; ASME safety valve Steam gauge Gauge glass with trimmings Optional Equipment Available in split assemblies. Specify on order. Trade Price ...........................525.50 Zone valve packages are available for water boilers. For details and prices, see page 33. For other optional equipment see page 25. Ordering Examples: 1. Pressure fired boiler-burner unit with standord equipment with heater for wottr: \ PFA-34-WT boiler-burner unit 2. Pressure fi rod boiler-burner unit with optionol equipment less heater for ittom: \ PFA-37-5 boiler-burner unit with jacket extension HH-75-1 "W See page 48 Page 24 For complete specifications refer to Technical Catalog Bulletin Form No 9114-2 (Rev. 0/74) 07632 HYORONIC HEATING PFA-3 OPTIONAL EQUIPMENT PRESSURE FIRED BOILER-BURNER UNITS WATER AND STEAM Jacket extension. TradePrice ......................................... $50.60 No. 5-Z control set for circulator zoning with PFA-3 boiler-burner unitsequipped for tankless heater. 1 No. 5-Z set required for each zone in addition to the first zone which is controlled by the No. 5 control set or equivalent. Trade Price ......................................................................... $30.05 McDonnell & Miller No. 67AR low water fuel cut-off for steam. Trade Price ......................................................$42.35 McDonnell & Miller No. 63 low water cut-off for water. Trade Price ......................................................................... $57.50 Controls and control sets are shown on page 34. I=W=H RATED BUILT-IN TANKLESS WATER HEATERS FOR PFA-3 Heaters tested with boilers. Built-in tankless heaters can be ordered /or separate shipment with units or boilers specified less heater as follows: (Mil ft*. PFA-34 PFA-35 PFA-36 PFA-37 Istst burner capacity gpA 2.65 3.30 3.95 4.60 heater i*e. 226 232 445 445 laws 1 rotinf water steam 6.0 6.0 7.5 7.5 90 90 9.0 9.0 rtirw heater at rated flew 23 psi 36 psi 37 psi 37 psi healer only* 'Trade Frit* $53.00 65.00 83.00 83.00 Go Hem *f water pr minute from 40*F fo I40*F wi*h ?00*F beilor voter temperon "Appropriate controls must be ordered m addition to healer only above. "W See page 46 Page 25 HH-75-1 07633 Oil BOILER-BURNER UNITS STEAM AND WATER PFA-5 PRESSURE FIRED BOILER-BURNER UNITS Jacketed--forced draft with oil burner. 60 lbs. water working pressure--15 lbs. steam working pressure. Equipped for tankless heaters. pressure fired Seller burner unit number ell frees ll~t output MM 1 wt-t Sumer capacity ell fph RifIn* and pickup feeter sterna water net Inlnl ratio* MM steam water sq. ft. roam net ratio* sq. ft. water Trade Price with standard equipment 41 vent site dlam. in. appre** imate shippin* weight burner medel supplied with standard equipment <n ' all PFA-504-* 0(T) PFA-505-* 0(T) PFA-505-* O(T) 620 786 950 5.45 6.90 8.35 1.333 1.333 1 333 1.15 1.15 1.15 465.1 589.6 712.7 539.1 683.5 826.1 1938 2457 2969 3594 4557 5507 $1944.00 2291.00 2554.00 10 10 10 1640 2210 2520 95A-1-6702-JBT 96A-M-6131-JC-T 96A-M-6131-JC-T PFA-507-* 0{T) PFA-508-* 0(T) PFA-5 09-* O(T) 1116 1282 1446 9.80 11.20 12.65 1.333 1.330 1 315 1.15 837.2 970.4 1.15 963.9 1114.8 1.15 1099 6 1257.4 3488 4016 4582 6469 7432 8383 2924.00 3241.00 3469.00 10 10 14 2880 3190 3550 96A-B-8316-JC-T 96A-B-8318-JC-T 96A-B-8318-JC-T PFA-510-' O(T) PFA-511-* 0(T) PFA-512-* 0(T) 1612 1776 1944 14.10 15.55 16.95 1 302 1 292 1 288 1.15 1238.1 1401.7 1.15 1374.6 1544.3 1.15 1509 3 1690.4 5159 5728 6289 9345 10295 11269 4065.00 4714.00 5087.00 14 14 14 3935 4285 4645 96A-T-A-8419-JC-T 97A-T-A-8614-JC-T 97A-T-A-8614-JC-T PFA-513-* 0(T) PFA-514-* 0{T) PFA-S1S-* 0{T) 2108 2272 2440 18.40 19.85 21.25 1.288 1 288 1.288 1.15 1636.6 1833.0 1.15 1764.0 1975.7 1.15 1894.4 2121.7 6819 7350 7893 12220 13171 14145 5331.00 5580.00 6101.00 14 14 14 4955 5317 5675 97A-T-A-8614-JC-T 97A-T-A-8615-JC-T 97A-T-2-7635-E-1 PFA-51S-* 0(T) PFA-517-* 0(T) PFA-S18-* O(T) 2604 2768 2936 22.70 24.15 25.60 1.288 1.288 1.288 1.15 2021.7 2264.3 1.15 2149.1 2407.0 1.15 2279.5 2553.0 8424 8954 9498 15095 16047 17020 6492.00 6720.00 7168.00 18 18 18 5985 6345 6750 97A-Hi-Lo-2-76B5-E-1 97A-HI-LO-2-7665-E-1 98A-Hi-Lo-2-7771-E-1 PFA-519-* 0(T) PFA-520-* O(T) PFA-S21-* O(T) 3100 3260 3430 27.00 28.45 29.90 1.288 1.288 1.288 1.15 2406.8 2695.7 1.15 2531.1 2834.8 1.15 2663.0 2982.6 10028 10546 11096 17971 18899 19884 7420.00 7663.00 7951.00 18 18 18 7060 7420 7780 98A-Hi-Lo-2-7771-E-1 98A-Hi-Lo-2-7771-E-1 | 98A-Hi-Lo-2-7771 -E-1 t Height 3 feet obo*e highest port of root. The net l = 6rrR ratings shown ore based on piping and pick-up allowances listed above. Americon.Stondard should be consulted before selecting o boiler for installations having unusual piping and pick-up requirements. A.eiiade as assembled unit or with assembled sections'--see page 27 *Subrtitut latter "S" for Hum; "W" for water. Start Up and Orta Year's Sarvica . .. Price on Application Suffix (T) denote* boiler with opaningi in cantar taction for tankless heaters whan tpacifiad. For Built-in Water Heater*. sec page 27. Nozzles sees--see cage # Nozzle sizes, gpn, turnisneo with the above oil burners are as follows: unit na. *ph. type 1 i I f unit na. *ph. type unit na. *pn. type unit *- h. type unit na. gph. typa PFA-504 2 2.75 90`H PFA-505 2 3.50 90`H PFA-S0S 2 4.00 80 *H PFA-507 1 4.50 70`H 1 5.00 70`H PFA-508 2 5.50 80`H PFA-509 1 6.00 B0`H PFA-512 2 7.00 70`H PFA-514 1 3.50 60`H PFA-517 1 10.00 90`S PFA-520 1 8.00 80*S 1 6.50 B0"H 1 2.50 70`H PFA-51S 2 8.00 70`H PFA-511 1 7.50 90`S 1 8.50 80`S PFA-510 2 5.50 90`H PFA-513 2 7.00 70'H 1 5.00 70`H 1 8.00 90`S 1 12.00 80`S 1 2.75 90*H 1 4.00 70`H PFA-516 2 7.00 90`S 1 10.00 90`S PFA-521 2 8.0Q 80*S PFA-511 2 6.50 80`H 1 8.50 90'S PFA-519 2 7.50 80`S 1 14.00 80'S 1 2.00 80`H PFA-514 2 8.00 60H PFA-517 2 7.00 90`S 1 12.00 B0*S HH-75-1 See page 48 Page 26 For complete soecitications reler to Technical Catalog Bulletin Form No 91T5-2 tRev 3 6^72> 07634 PFA-5 pressure fired boiler-burner units Standard Equipment--All RoiUr* Steam: PA404A Pressuretrol, ASME safety valve, steam gauge, gauge glass with trimmings, drain valve. Water: L4006A Aquastat, ASME relief valve, pressure and temperature gauge, drain valve. Standard Equipment--Oil Fired Flange mounted oil burner--97A-T-A, 97A-T-2, 97A Hi*Lo and 98A Hi-Lo burners furnished with flange and pedestal. On 95-A1, 96A-M, 96A-B, 96A-T-A and 97A-T-A burners, factory installed cad cell, bracket and leads, R8185E light sensing primary control; V4046B instantaneous oil valve, ST70A1002 electronic time delay. On 97A-T-2, 97A Hi-Lo-2 and 98A Hi-Lo-2 burners, R4150A control--provides prepurge and post-purge, Q520A base, factory installed C7013A photo cell; delayed and instantaneous oil valves, nozzles. 2 stage fuel unit on all burners. Standard Motor Voltage* PFA-504 thru PFA-510 PFA-511 thru PFA-521 116/60/1 230/60/1 Ordering Example*-. PFA-5 boiler-burner unit for iteom with itandard equipment. 1 --PFA-514-SO boiUrbufthr unit PFA-5 boilr-burnar unit for wotir with optional *quipnsnt. 1-- PFA-511 -WO(T) with fockat axtaniion; 4 No. 543 tankiaii hootari; with 16006A control. Optional Equipment--Oil Fired Oil Burners equipped for F.M. or Massachusetts Code requirements for PFA-504 through PFA-514. Added Trade Price ........................................................ *215.00 R,,,-n..-c fny PFA-515 through PFA 521 a.e equipped to meet F.M. requirements. (Equipment includes: R4150A which provides pre- and post-purge, C7013A Photo Cell and Q520A Base.) Oil Burners for F.I.A. requirements--Price on application. Oil burners for PFA-515 thru PFA-521 for Massachusetts Code requirements--Price on application. Prewired Control Panels on burners--Prices on applica tion. Optional burners and assembly arrangements, listed be llow. PFA-5 OPTIONAL ASSEMBLY AND OIL BURNERS PFA-S04 PFA-505 PFA-506 PFA-507 PFA-508 PFA-509 PFA-510 PFA-511 PFA-512 PFA-51 3 PFA-514 PFA-515 PFA-516 PFA-517 PFA-518 PFA-519 PFA-520 PFA-521 ABC oil burner* 96A-T-A-8406 J8T 96A-T-A-84 08 JBT 96A-T-A-S408 JCT SI 63.00 153.00 153.00 96A-T-A-8409 JCT 96A-T-A-8410 JCT 96A-HI-LO-A-8808 JCT 96.00 96.00 350.00 96A-HI-LO-A-8808 JCT 254.00 astamblad section* $ 99.00 165.00 198.00 231.00 264.00 297.00 330.00 363.00 396.00 429.00 462.00 495.00 528.00 561.00 594.00 627.00 660.00 693.00 add to Trada Prica packaged botlar unit 0 Ibt. water last S666.00 684.00 702.00 719.00 737.00 848.00 869.00 889.00 910.00 929.00 949.00 969.00 990.00 1010.00 1031.00 1050.00 1071.00 1091.00 5 44.00 55.00 66.00 77.00 68.00 99.00 110.00 121.00 132.00 143.00 154.00 165.00 176.00 IB 7.00 198.00 209.00 220.00 231.00 jacket extension S85.15 65.15 85.15 85.15 65.15 85.15 65.15 65.15 85.15 85.15 65.15 85.15 85.15 65.15 65.15 85.15 85.15 65.15 Gordon-Piatt oil burner* RL 6 2-Q-03-F4B RL6 2-0-03-F48 RL 6.2-0-03-F4B $62.50 61.00 61.00 RL 8 0-0-05-F4B RL 8 1-0-05-F4B RL 8 1-0-05-F4B 26.00 28.00 2B.00 RL 8 2-0-10-F4B RL 8.2-0-10-F48 RL 8 2-0-10-F4B RL 8 2-0-15-F4B RL 8.3-0-15-F4B RL 6.4-0-20-F4B RL 8.4-0-20-F4B RL 10.1 -0-2Q-F4B RL 10.1-0-20-F4B RL 10.1-0-30-GP100R-F4B RL 10.1 -0-30-GP100R-F4B RL 10 1-0-30-GP10QR-F4B 77.00 __ -- _ __ -- _ __ -- __ _ -- W See page *6 Page 27 HH-75-1 07635 GAS BOILER-BURNER UNITS STEAM AND WATER PFA-5 PRESSURE FIRED BOILER-BURNER UNITS Jacketed--forced draft with pas burner. 50 lbs. water working pressure--15 lbs. steam working pressure. Equipped for tankless heaters. bmter-burwer util number ** r*M i ==t output Mbh -Im-ftst burner coo<itr Input Mbh piping Ad <kup farter team water net 1 t= I = rating Mb* team water I*, ft. team PFA-504-* G(T) PFA-505-' G(T) PFA-506-* G(T) 620 786 950 763 966 1169 1.333 1.333 1 333 1.15 1.15 1.15 465.1 589.6 712.7 539.1 683 5 826.1 1938 2457 2969 net reting e ft. water 3594 4557 5507 'W Trod# Price with standard equipment go* 3111.00 3434.00 3687.00 vent lie diam. in. qprex* Itnate hipping weight burner medel tuppUed with standard equipment 10 1840 R6.2-G-03-R4795 B.12S 10 2210 R6 2-G-03-R4795-B.12S 10 2520 R6.2-G-03-R4795-B.12 PFA-507-* GIT) PFA-508-* G(T) PFA-509-* G(T) 1116 1282 1446 1372 1568 1771 1 333 1 330 1.315 1.16 837.2 970 4 1.15 963 9 1114.8 1.15 1099 6 1267 4 3488 4015 4582 6469 7432 8383 4114.00 10 2880 R8-G-05-R 4795-8.12 4446.00 10 3190 R8G-05-R4795-B.15 4674.00 14 3550 R8-G-G5-R4795-8.15 PFA-510-* G(T) PFA-511-- G(T) PFA-512-' G(T) 1612 1776 1944 PFA-513-* GIT) PFA-S14-* G(T) PFA-515-* G(T) 2108 2272 2440 1974 2177 2373 2576 2779 2975 1 302 1.292 1 288 1.288 1.288 1.288 1 15 1238 1 1401 7 1 15 1374.6 1544.3 1.15 1509 3 1690 4 5159 5728 6289 9345 10295 11269 1 15 1636.6 1833 0 1.15 1764 0 1975.7 1 15 1894 4 2121.7 6819 12220 7350 13171 7893 14145 5273.00 14 3935 R8.1G-05.R4795-B.20 5990.00 14 4285 R8.2G-05-4150AH.20 6386.00 14 4645 R8.3-G-10-41 50A-H 20 6699.00 14 4955 R10.9-G-10-4150A-H 20 6948.00 14 5315 R10 9-G-10-41 50A- H. 20 7170.00 14 5675 R10.9-G-10-41 50A-H 20 PFA-516-* G(T) PFA-517-* G(T) PFA-518-' G(T) 2604 2768 2936 3178 3381 3584 1.288 1 288 1.288 1 15 2C21 7 2264 3 1 15 2149 1 2407 0 1.15 2279 5 2553 0 8424 15095 8954 16047 9498 17020 7650.00 18 5985 R 10-G-15-4150A H 25S 7878.00 18 6345 R10-G-15-4150A-H 25S 8124.00 18 6750 R10.1-G-1 5-41 50A-H 25S PFA-519-* G(T) PFA-520-" GfT) PFA-521-* G(T) 3100 3260 3430 3780 3983 4186 1.288 1 288 1 288 1 15 2406 8 2695 7 1.15 2531 1 2834 8 1 15 2663 0 2982.6 ________ 1 10028 17971 10546 18899 11096 19884 8628.00 18 7060 R10 1-G-20-41 50A-H 25 8872.00 18 7420 R10.1 -G-20-41 50A-H 25 9160.00 18 7780 R10 1-G-20-4150A-H 25 The net t = 8=R rotingt ihown ore bosed on piping and pick-up allowance! lilted above. American-Standard ihould be coniulted before selecting a boiler for installations having unusual piping and pick-up requirements. 'Substitute letter "S" for tteom, "W" for water. START-UP AND ONE YEAR'S SERVICE. INCLUDED IN TRADE PRICE OF CAS UNIT :l) Suffi* (T) denotes boiler with openings in center section for tankless heoters when specked For Built-in Water Heaters, see page 27. Height 3 feet above highesl pari of roof. Available as assembled unit or assembled sections--see cage 2~ Standard Equipment--All Boilers Steam: PA404A Pressuretrol, ASME safety valve, steam gauge, gauge glass with trimmings, drain valve. Water: L4006A Aquastat, ASME relief valve, pressure and temperature gauge, drain valve. Standard Equipment--Gat Fired Flange mounted gas burner. Standard burner controls meet latest UL requirements. Dual automatic gas valves for add ed reliability. Gas-electric ignition. Electronic program ming controls and components are factory wired in a con trol cabinet on the burner. Includes R4795 control on 4 thru 10 section; R4150A control on 11 thru 21 section; proven pilot. Standard burners equipped to operate with 1,000 Btu, 0.6 specific gravity natural gas. Ordering Example*: PFA-5 baiter-burner unit for iteom with stoodord equipment. 1--PFA-514-SC boiler-burner unit PFA-5 boiler-burner unit for water with optional equipment. 1-PFA-511-WG(T) witK jacket extension; 4 No. 545 tanklen heater*. Specify gas pressure ovoiloble ot gas troin inWt. O) Surcharge for Start-Up and Service west of Mississippi River. Contact American*Standard for details. Optional Equipment PFA-5 units for Factory Mutual and Factory Insurance Association Diinimiim requirements at the following added charges: boiler iize F.M. 9* fired ----- F.I.A. PFA-504-510 $682.00 S 827.00 PFA-511-515 PFA-516--521 811.00 811.00 1074.00 1074.00 For prices of gas burners for use with other than 1000 Btu, 0.6 specific gravity natural gas, or at gas pressures above or below pressures shown in current literature, consult your American Standard District Office. High Risk F.M. or F.I.A. requirements...... Hi-Lo Fire Control .................................... Modulating Fire Control ................................ Price Alarm System pre-wired and mounted on on control cabinet................................................. Optional Combustion Controls ....................... Application Controls to meet local requirements ........... For Additional Optional Equipment and assembly ar rangements, see page 27. Ges end G*s-0<l Burners nol stocked si Bond Plan! 3 to 4 weeks lead lime for shipment of Standard Equipped Burners after receipt of order at Hydronic Order Service Center. Standard Motor Voltages unit numbtr go* bv'Mti PF A-504-511 PFA-512-521 115-60-1 230-60-3 Other optional motor voltages--Price on Application. HH-75-1 W See page 48 Page 28 Fpf compieie specification* refer to Technical Ca's'og Bui'eim Form No 9115-2 (Rev 3 6'72) 07636 PFA-5 PRESSURE FIRED BOILER-BURNER UNITS Jacketed--forced draft with combination pas/oil burner. 50 lbs. water working pressure--15 lbs. steam working pressure. Equipped for tankless heaters. GAS--UGWT Ott BOILER-BURNEH UNITS STEAM AND WATER pretture fired beiler-bwmev **' gag lgh< <! grtil a|* IBburInSer I copoclty eutput Mbh input Mb* piping and teier steam water net s|s| rating Mbfc e. ft. iteom water team net rating Ml. ft. water ^ Trade Frit# with Standard equipment gat-- etl vent site rfiam. in. Imate hipping wlghf burner medtl tuaplied with tandord equipment go -- erl PFA-S04-* GO(T) PFA-50S-* 60(T) PFA-506-* GO(T) PFA-507-* GO(T) PFA-508-* GO(T) PFA-509-* GO(T) PFA-510-* GO(T) PFA-511-* GO(T) PFA-512-* GO(T) PFA-513-* GO(T) PFA-S14-* GO(T) PFA-515-* GO(T) PFA-516-* GO(T) PFA-S17-* GO(T) PFA-518-* GO(T) PFA-519-* GO(T) PFA-520-* GO(T) PFA-521-* GO(T) 620 . 763 786 966 950 1169 1116 1372 1282 1568 1446 1771 1612 1974 1776 2177 1944 2373 2108 2576 2272 2779 2440 2975 2604 3178 2768 3381 2936 3584 3100 3780 3260 3983 3430 4186 1.333 1.333 1.333 1.333 1.330 1.315 1.302 1.292 1.288 1.288 1 288 1 288 1 288 1 288 1.288 1 288 1.288 1.288 1.15 1.15 1 15 465 1 589.6 712.7 539.1 683.5 826.1 1.15 837.2 970.4 1.15 963.9 11 14 8 1.15 1099.6 1257.4 1.15 1238.1 1401.7 1.15 1374 6 1544.3 1.15 1509.3 1690.4 1.15 1636.6 1833 0 1.15 1764 0 1975.7 1 15 1894 4 2121.7 1 15 2021.7 2264 3 1.15 2149.1 2407.0 1.15 2279 5 2553.0 1.15 2406 8 2695 7 1.15 2531.1 2834 8 1.15 2663 0 2982 6 1938 2457 2969 3488 4016 4582 5159 5728 6289 6819 7350 7893 8424 8954 9498 10028 10546 11096 3594 4557 5507 6469 7432 8383 9345 10295 11269 12220 13171 14145 1S09S 16047 17020 17971 18899 19884 $3636.00 3959.00 4309.00 4679.00 S082.00 5310.00 5961.00 6443.00 6927.00 7243.00 7492.00 7714.00 8190.00 8418.00 8768.00 9188.00 9548.00 9836.00 10 10 10 10 10 14 14 14 14 14 14 14 18 18 18 18 18 18 1840 2210 2520 R6.2-GO-03-R4795-B.12S-F4B R6.2-GO-03-R4795-B.12S-F4B R6.2-GO-03-R4795-B.12-F4B 2880 3190 3550 R8-GO-05-R4795-8.12-F3 R8-GO-05-R4795-8.15-F3 R8-GO-OS-R4795-B.1S-F3 3935 4285 4645 R8.1-GO-05-R4795-B 20-F3 R8.2GO-07.4150A-H.20.F4H R8.3-GO-10-4150AH.20-F4H 4955 5315 5675 R10 9-GO-10-4150A-H 20-F4H R10 9-GO-10-41 50A-H.2Q-F4H R10.9-GO-10-41 50A-H 20-F4H 5985 6345 6750 R10-GO-15-4150A-H.25SF4H R10-GO-15-4150A-H 25S-F4H R 10.1 -GO-20-4150A-H.25S-F4H 7060 7420 7780 R10.1-GO-20-4150AH.25-F4H R10.1-GO-30-4150A H 25-F4H R 10.1-GO-3O-4150A-H 25-F4H The nqt I r I = K ratings shown ore based on piping and pick-up allowances listed above. American-Standard should be consulted before selecting a boiler for installations having unusual piping and pick-up requirements Substitute letter "S" for steam. "W" for water. START-UP AND ONE YEAR'S SERVICE. INCLUDED IN TRADE PRICE OF GAS-Oll UNIT (I) Suffix (T) denotes boiler with openings in center section for tonkless heaters when specified For Built-in Water Heaters, see page 27. Height 3 feet above highest port of roof. Available as assembled unit or assembled sections--see page 27 Standard Equipment--All Boilers Steam: PA404A Pressuretrol, ASME safety valve, steam gauge, gauge glass with trimmings, drain valve. Water : L4006A Aquastat, ASME relief valve, pressure and temperature gauge, drain valve. Standard Equipment--Gas-Light Oil Fired Flange mounted combination gas-oil burner. Standard burner controls meet latest UL requirements. Manually operated fuel switch for dual fuel change-over. Dual auto matic gas valves for added reliability. Gas-electric ignition. Elect:omc programming controls and components are fac tory wired in a control cabinet on the burner. Includes R4795 control on 4 thru 10 section; R4150A control on 11 thru 21 section; proven pilot. Standard burner equipped to operate on No. 1 or No. 2 fuel oil and 1,000 Btu, 0.6 specific gravity natural gas. ^hNoziie sues, gpn, furnished with combination gas-light oil burners are as follows: (nozziecaoaatyis dependent on oil pressure.) unit ne. gph. type unit ne. gph. type unit no gph. Type PFA-504 1 4 00 90H PFA-505 1 5 00 90H PFA-506 1 6 50 90H PFA-507 2 4.00 90S PF A-508 2 4,00 90S PFA-509 2 5.00 90S PFA S10 2 5 00 90S PFA-511 2 5.50 90S PFA-512 2 6.00 90S PFA-513 2 7.00 60S PFA-514 2 7.00 60S PFA-515 2 7.00 60S PFA-516 2 7 00 60S PFA-51 7 2 8 00 60S PFA-518 2 8.00 60S PFA-519 2 8 00 60S PFA-520 2 8 50 60S PFA-521 2 9 00 60S Optional Equipment PFA-5 units for Factory Mutual and Factory Insurance Association minimum requirements at the following add ed charges: get-ail fired! boiler site F.M. F.I.A. Standard Motor Voltages unit number pot-nil burner* PFA-504--5r0 115-60-1 PFA-511 230-60-1 PFA 512-521 230-60-3 Other optional motor voltages--Price on Application. (11 Surcharge far Start-Up and Service we* of Mississippi River. Contact American-Standard far details. Ordering Examples; PFA-5 boiler-burner unit for steam with standard equipment. 1--PFA-5IA-SGO boiler-burner unit. PFA-5 boiler-burner unit for woter with optional equipment. 1 -- PFA-511 -WGO(T) with jacket extension; 4 No. 548 tonkless heaters. Specify gas pressure available at got train inlet. PFA-504--510 PFA-511-515 PFA-516-52! $ 824.00 1059.00 1054.00 $ 899.00 1227.00 1239.00 Automatic Fuel Changeover Trade PriceVT.............................................................................. 9237.00 For prices of gas-oil burners for use with other than 1000 Btu, 0.6 specific gravity natural gas, or at gas pressures above or below pressures shown in current literature, consult your American Standard District Office. High Risk F.M. or F.I.A. requirements...... Hi-Lo Fire Control ............................................. Modulating Fire Control...................................... Price Alarm "System pre-wired and mounted on control cabinet................................................. Optional Combustion Controls........................ on Application Controls to meet local requirements ........... Additional optional equipment and assembly arrangements --see page 27. Gas and Gaa-Oil Bumars not Blocked at Bond Plant 3 to 4 weeks lead time for shioment of Standard Equipped Burners alter receipt of order ar Hydromc Order Service Center. W See page 48 Page 29 For complete specifications reer 10 Technical Caialog BuMeim Form No. 911S-2 (Rev. 3 6/72) HH-75-1 07637 OPTIONS--A-5/FRA-S/PFA-5 TANKLESS WATER HEATERS LOW WATER CUT-OFFS fail AMERICAN LS STANDARD HYDRONIC HEATINO TANKLESS WATER HEATERS FOR A-5, FRA-5 AND PFA-5 Tankless water heaters are available in any quantity at the following Trade Prices: Uetar iMPUf uwd with pres. drop at ratad flow Trad# PrUe --d> 530 A-5, FR-A-5 548 PFA-5 15 psi 16 psi $54.00 89.55. PFA-5 units with tankless water heaters require additional controls at current prices as follows: STEAM: L4006A Aquastat operating control. Trade Price $16.90 WATER: L6006A Aquastat operating and circulator control. Trade price $17.95 Cover plate required to close unused water heater open ings will be furnished if specified on order for "T" type boiler. Trade Price each ............................................................. PFA-5, A-5. FRA-5........... Trsde Price Met......................$5.45 Factory assembled copper pipe manifold for parallel hook up of multiple heaters are available as follows: tw A-J, .*.J 2 Hsstsr.................................................................. $11.05 3 Hester................................................................... 16.00 4 Hseter................................................................... 20.50 A*S MAS Uttar A-5 or FR-A-S04-T A-5 or FR-A-505-T thru 507-T A-5 or FR-A-508-T thru S09-T A-5 or FR-A-510-T thru S11-T IMS. M. 8p8Wlfi 2 3 4 5 PFA-J Uttar PFA-504-T PFA-505-T thru 506-T PFA-507-T thru 508-T PFA-509-T thru 511-T mai. m. i 2 3 4 PfA-S WtUr PFA-512-T thru 514-T PFA-515-T thru 517-T PFA-518-T thru 519-T PFA-520-T thru 521-T SMI. M. < 5 6 7 8 The following table shows ratings attained if more than one heater is connected in parallel: lonklcat n*. SX SmN4 H*. Ml 1*0 *1 Uartm *rotine gptn. Uttar wwwUr m* ef taatin A-5 or FR-A-5-T all sizes A-5 or F R-A-5-T ail sizes A-5 or FRA-506-T thru 511-T A-5 or FR-A-508-T thru 511*T A-5 or FR-A-510-T thru 511-T 1 2 3 4 5 4 PFA-5-T all sizes 7 PF A-505-T thru 506-T 10 PFA-507-T thru 508-T 13 PFA-509-T thru 511-T 16 PFA-S12-T thru 514-T PFA-515-T thru 517-T PFA-518-T thru 519-T PF A-520-T thru 521-T 1 2 3 4 5 6 7 8 raiW 40*P 140*F with J0O*F U'tar >o'i' fottaf ee*"- 8 16 24 32 40 48 56 64 McDonnell & miller low water cut-offs "W TrA Srlu STEAM: No. 369 Low Water Cut-off for A-5. FR-A-6, PFA-6 ..................................................$ 34.30 No. 47-2 Feeder and Cut-off for A-5, FR-A-5, PFA-604 thru PFA-509 ............... 98.00 No. 51-2 Feeder and Cut-off for PFA-510 thru PFA-621 .......................................... 127.05 WATER--60 PSI: No. 63 Low Water Cut-off for A-5, FR-A-6 and PFA-5 ........................ 57.50 WATER--80 PSI: No. 150 Low Water Cut-off for PFA-5 ........................................................ 85.90 HH-75-1 W See page 48 Page 30 07638 AMERICAN kSJ STANDARD HYDRONIC HEATINO OIL FIRED BOILER-BURNER UNIT WATER AND STEAM FR-A-5 FLAME RETENTION BOILER-BURNER UNITS Jacketed--50 lbs. water working pressure--15 lbs. steam working pressure. Sections precision ground--with or without tankless heaters. 115 volt, 60 cycle power supply. WATER boiler-burner untt number .I*s*l?a*R output Ubh burner capacity fph net l*B=ft retlng Ubh net retlng sq- ft. water Trede Price with tandsrd equipment For BuitMn Water Heaters, Staam and Water Boilers, see page 27. appro*. hipping weight chimney else . A tpf. . " e ; Bfl B1 HI [HKb K B Hr ^9 FR-A-504-WB(T) FR-A-505-WB(T) FRA-506-WBO) FR-A-507-WBfT) FR-A-508-WB(T) FR-A-509-WB(T) FR-A-510-WBfT) FR-A-5ll-WB(Tj 384 472 560 648 736 824 912 1000 3.55 4.30 5.10 5.90 6.70 7.45 8.25 9.05 333.9 410.4 487.0 563.5 640.0 716.5 793.0 869.6 2226 2736 3246 3756 4266 4776 5286 5797 STEAM boHer-bumer unit number FR-A-504-SB(T) FR-A-505-S8(T) FRA-506-SBCT) FR-A-507-SB(T) FRA-508-SBfn FR-A-509-SB(T) FR-A-510-SB(T) FR-A-511SBCT) crocs IsBaft output Ubh burner capacity gph 384 472 560 648 736 824 912 1000 3.55 4.30 5.10 5.90 6.70 7.45 8.25 9.05 net t = B:eft rating Ubh ftq. ft. staam 288.1 354.1 420.1 486.1 552.1 618.2 684.2 750.2 1200 1475 1750 2025 2301 2576 2851 3126 $1394.00 1542.00 1798.00 1963.00 2288.00 2453.00 2630.00 2805.00 1576 1827 2110 2367 2626 2890 3144 3392 12 x 12 x 15 12 x 12 x 20 12 x 12 x 20 12 x 16*20 12 x 16x20 12 x 16x20 16 x 16 x 20 16 x 16x20 Trade Pries with standard equipment 1394.00 1542.00 1798.00 1963.00 2288.00 2453.00 2630.00 2805.00 approx. shipping weight chimney Ue 1577 1828 2112 2369 2628 2892 3147 3395 12 x 12 x 15 12 x 12 x 20 12 x 12 x 20 12 x 16 x 20 12 x 16 x 20 12 x 16 x 20 16 x 16x20 16 x 16 x 20 *haGO nozzle sues con furnished 'or Above units FRa-504. 3 5. 80" P. FflA-505 4, 60" P; FRA-506, 5 60* P FRA-507 6 60 P, FRA-5C8 6 5 4$ P FRA-509. 7 5. 45* P. FRA-S10 8 45* P. FRA-5U. 9. *5* P Suffi* "T' denotes unit with openings in center sections ter tankless heaters. Start-up end one year service available. Price on application. Standard equipment Flange mounted oil burner with 2*stage fuel unit; delayed oil valve on model LC-534-A and instantaneous on HC-34A oil burners; light sensing pnmaiy control. boilerbumer untt number ell burner FRA-504 thru FRA-507 LC-534A-D 41752 FRA-S08 thru FRA-511 HC-34-A-D 41751 Draft regulator Drain valve Water No. 3 control set: T822D thermostat L4080B Aquastat limit control Nozzle(s) ASME relief valve Pressure and temperature gauge Steam: No. 1 control set: T822D thermostat PA404A Pressuretrol Nozzle(s) ASM_E safety valve Steam gauge Gauge glass with trimmings Optional Equipment 80 lbs. water test. Trade Price per section ...............111.00 Jacket extension. Trade Price ........................................ $56.00 Cover plate required to close unused water heater openings furnished if specified on order for "T" type boiler. Trade Price each ...............................................................................$5.45 For Factory Mutual Approval and Massachusetts code requirements, special electronic flame safeguard controls are available, with R4150A Protectorelay, C-7013A photo cell, and safety oil valve. Control sets other than those included in Trade Price of FR-A-5 boiler-burner units will be furnished on order at the following added charges: Control S*t eddwd charge Steam control set No. 2 $16.90 oil heating unit FRA-504 thru FRA-507 FRA-508 thru FRA-511 bumar model LC-534A-D 41431 HC-34-A-D 41431 ^ added Trade Price charge Water control set No. 5 Water control set No. 5-Z 25.85 30.05 $282.00 {Add-on zone. Use only with No. 5 Control Set. The No. 5-Z control set ter circular zoning on units with tankles* heaters.) Ordering Examples: 282.00 1. Boiler-burner unit with standard equipment: 1 FR-A 506-SB oil heating unit. 2. Boiler-burner unit for steam with optional equipment: 1 FRA-509-SB-T with No. 2 control set: 3 No. 530 tankless heaters; 1 3-heeler manifold. See page 48 Page 31 For complete ipecificaiiori* refer lo Technical Cm*'TM-. Form No 768-? (Rev 7/73) HH-75-1 07639 oil fired boilers WATER AND STEAM AMERICAN baSTANDARD HTDRONIC HEATING A-5 OIL FIRED BOILERS Jacketed--50 lbs. water working pressure--15 lbs. steam working pressure. Sections with or without tankless heater. boiler number greet IsSsft output Mb* burner eepeefty CP* net tsBsR rating Mb* net rating 9* water Trade Prteo apprwz. ftMppfetf weight For Built-in Water Heaters, Steam and Water Boilers, see page 27. A-504-W(T) A-505-W(T) A-506-WfO A-507-Wm A-508-WfT) A-509-W(T) A-5I0-W(T) A-511-W(T) 261 346 426 508 588 668 748 830 2.55 3.30 4.00 4.75 5.55 6.30 7.00 7.65 227.0 300.9 370.4 441.7 511.3 580.9 650.4 721.7 1513 2006 2469 2944 3408 3872 4336 4811 *1002.00 1151.00 1311.00 1477.00 1636.00 1794.00 1959.00 2129.00 1518 1770 2025 2282 2539 2794 3050 3298 chimney Jxe 8x 12 x 15 8 x 12x20 12 x 12x20 12 x 12 x 20 12 x 16x25 12 x 16x25 12 x 16 x 25 16 x 16 x 30 STEAM boiler number A-504-S(T) A-505-S(T) A-506-S(T) A-507-S(T) A-508-SfT) A-509-Sfn A-510S(T) A-511-SCO gross !=B=R output Mbh 261 346 426 508 588 668 748 830 IsBsR burner capacity CP* 2.55 3.30 4.00 4.75 5.55 6.30 7.00 7.65 net 1 = # = R rating Mbh sq ft steam 195.8 259.6 319.6 816 1082 1332 381.1 441.1 501.1 1588 1838 2088 561.1 622.7 2338 2594 Trade Price $1002.00 1151.00 1311.00 1477.00 1636.00 1794.00 1959.00 2129.00 approa. shipping weight 1519 1771 2027 2284 2541 2796 3052 3300 chimney atxe 8 x 12 x 15 8 x 12 x 20 12 x 12 x 20 12 x 12 x 20 12 x 16 x 25 12 x 16 x 25 12 x 16 x 25 16 x 16 x 30 Suffii "T" denotes boiler with openings In center sections for tankless halters. Standard equipment: Optional equipment: Water. ASME relief valve Pressure and temperature gauge Drain valve Cover plate required to close unused water heatei openings furnished if specified on order for "T" type boiler. Trade Price each .................................................................................. *5.45 Steam: ASME safety valve Steam gauge Gauge glass with trimmings Drain valve Ordering Examplts: 1. Boiler only for steam with standard equipment: 1 A 507 S boiler. 2. Bode' only for water with optional equipment: 1 A 506 W boiler with jacket extension Zone valve packages are available for water boilers. For details and prices, see page 33. Oil Burners available on special order .............................................. Price on Application Jacket extension: Trade Price ...........................................*56.00 80 lbs. water test. Trade Price per section ..................*11.00 For complete specifications refer to Technical Catalog Bulletin Form No. 758-2 (Rev 2 5/71) A-5 OPTIONAL EQUIPMENT HEAT LIB-O-RATOR MOLDED REFRACTORY COMBUSTION CHAMBERS unit number A-504 A-505 A 506 A-507. A-508 A-509. A-510, A-511 Heat Ub-O-Rator model No. included 14-A 15-A 15-AA 16-A 17-A maximum firing rate gallons per hour 2.55 3.30 4.00 5.55 7.65 Trade Price $51.00 51.00 65.00 65.00 74.00 approx. shipping weight 158 163 176 180 200 HH-75-1 See page 4fl Page 32 07640 , -- I AMERICAN kSJ STANDARD HYDRONIC HIATI NO OIL BURNERS OPTIONAL EQUIPMENT DH OIL BURNERS The DH burner. 115 volt, 60 cycle power supply. capacity ei. pwr iawr eir tvbe dime. UnpHi Trade Price vlrti oeule Include* factory tottolWd cad cell arllfc N. 1 r M. } centre! ref and primary central with primacy central md hassle lets end cell app. d*lp. weifM #wi* centre! at DH-4-F DH-5-F DH-5 DH-8 DH-15 DH-23 .55-3.00 .55-3.00 .55 - 3.00 .65-3.00 .65 - 3.00 .65 - 3.00 4 4 4 4 4 4 4 sling 5 sling 5 sling 8 (pedestal) 15 < or ? 23 1 flange ! $208.00 208.00 208.00 218.00 218.00 218.00 $186.00 186.00 186.00 191.00 191.00 191.00 $148.15 148.15 148.15 153.70 153.70 153.70 55 55 55 60 64 68 Mttr-biimcr unit oil burmr contrail Disc-turbulator combina tions for DH oil burner are as follows: Selection of nozzle: V-3M boiler unit OH-5 (Primary control, controls. Cad cell factory installed. I. Draft regulator. Note: For V-3M units pressure ring is packed with DH-5 burner. firing rate no. fph Bring rate tph nozzle eprpy .55 to 1.25 60*-70* hollow i .65-1.10 or solid 2 .90-1.75 3 1.80-2.50 above 1.25 60*-70* solid 4 2.35-3.00 Oil burners listed in this Price Book are approved by the National Board of Fire Underwriters, comply with U. S. Government Commercial Standard CS-75, and are for use with No. 1 or No. 2 fueloil. The correct disc-turbulator combination is furnished in stalled in the DH burner for nozzle site specified on order. Two-stage fuel unit available for DH oil burners. Capacities of oil burners using No. 1 or No. 2 fueloil are for installations at sea level and at elevations up to 1,000 feet. Reduce by 47c for each additional 1,000 feet above sea level. Trade Price ......................................................................... $6.30 Controls and control sets are shown on page 31. Ordering examples: 1. Oil Burner 1 OH-5 oil burner with No. 5 control set and 1.25 gpii 70"' solid nozzle for V3M138WT boiler burner unit. 2. Oil Burner 1 OH-23 oil burner with No. 3 control set. 1 50 gph 60* solid nottle, with pedestal. for complete specifications refer to Tecrmcai Catalog Sclletirv Form No. 60-2 (Rev.) HYDRONIC ZONE VALVE PACKAGES No. Z-2 Package for 2 Zones No. Z-3 Package for 3 Zones No. Z-4 Package for 4 Zones 1 T822D thermostat 2 T822D thermostats 3 T822D thermostats 2 V8043F lone valves soldered to 3 V8043F \" zone valves soldered to 4 V8043F 44" zone valves soldered to manifold manifold manifold Less transformer Less transformer With transformer ^ Trade Price............................... $106.00 Trade Price ........ ................. $140.00 ^Trade Price ................................ $190.00 Each zone valve package consists of 2, 3, or 4 Honeywell %4" zone valves soldered to manifold with 114" NPT inlet, wired to low voltage leads for transformer and all (auxiliary) switches wired in parallel with a pre-wired harness. On-the-job wiring requires 115 volt line to transformer, low voltage connections to circulator con trol, and low voltage wiring to each thermostat. If V6" system piping is used, a % x 54 nominal copper to copper flush bushing can be soldered to any or all of the % " zone valves on the manifold. Flush bushing not furnished. One less thermostat is furnished than the number of zone valves per package. An additional thermostat is required when zone valve package is used on boiler furnished less thermostat. 40 VA transformer is not required when control L8148G or R8226B with power for 3 zone valves, is supplied with boiler. If 40 VA transformer is wanted with No. Z-2 or No. Z-3 Packages, specify on order and add to the above Zone Valve Pack age prices....................................................................................................................................................................T Trade Price each $4.00 Honeywell V8043F Zone Valve sold separately . T Trade Price each $25.00 NT See page 48 For complete specification* refer to Technical Catalog Bulletin Form No. 2S66>2 (1/69) Page 33 HH-75-1 07641 CONTROL SETS, CONTROLS fS\ AMERICAN SJSTANDARD HYDRONIC HEATING CONTROL SETS FOR BOILER-BURNER UNITS Control tet no. 1 steam no. 2 steam for boiler without domestic hot water boiler with year-round domestic hot water, tankless heater no. 3 gravity water no. 4 forced water briler without domestic hot water, immersion control boiler without domestic hot water no. 5 V-3, V-3M, A-5, FR-A-5 units only with forced water year-round domestic hot water no. 5-Z forced water V-3, V-3M, A-5, FR-A-5 units only, fl no. 5-Z set is required for each zone in addition to the first zone which is controlled by the no. 5 control set or equivalent.) control number T822D PA404A T822D PA404A L4006A T822D L4080B T8220 L4081B T822D L8124C T822D R845A contents of control tot description Thermostat Pressuretrol Thermostat Pressuretrol Aquastat operating control Thermostat Aquastat limit control Thermostat Aquastat limit and circulator control Thermostat Aquastat limit, reverse and operating control, circulator relay Thermostat Relay add to Trade Price of oil burner with bade control set $16.90 $12.15 $25.85 $30.05 number T822D TS822A T882A L4006A L4006E L4081B L4080D L4080B L6006A L8124C L81248 L8124E L404C L604A LSI48E L8148G description thermostat, adjustable heater 0.18 to 0.8 amp. thermostat, millivolt thermostat, electric clock Aquastat operating control Aquastat operating control; locks out on high limit setting; manual reset Aquastat limit and circulator control Aouastat limit control Aquastat limit control Aquastat operating and circulator control Aquastat limit, reverse and operating control, circulator relay; line voltage burner control, horizontal case for gas or oil manual-auto switch, vertical case low voltage burner circuit for gas, vertical case. Power for 2 zone valves Aquastat-relay combination, high limit and line voltage circulator control. horizontal case: Pressuretrol w/man. reset SPDT operating controller low voltage burner control for gas. Power for 2 zone valves. millivolt burner control for gas. Power for 3 zone valves. CONTROLS ^ Trad* Price number $ 7.70 7.70 37.20 16.90 19.40 PA404A RA89A RA832A R845A R8226B R8182D 25.15 13.00 13.00 17,95 R8182E aa.as 35.30 38.15 34.20 33.95 24.40 26.65 R8182F R8184G 120320 description ^ Trade Price Pressuretrol relay, SPST relay, DPST relay, DPST Transformer and circulator relay Aquastat-relay combination, high and low limit; providing room thermostat control of circulator: light sensing primary control, less cad cell; safety switch timing 70 seconds. For use with tankless. Aquastat combination, high limit; providing room thermostat control of circulator: light sensing primary control. less cad cell; safety switch timing 70 seconds. For use less tankless. Aquastat combination, high limit: providing room thermostat control of burner and boiler water temperature control of circulator; light sensing primary control, less cad cell; safety switch timing 70 seconds. For use less tankless. light sensing primary control, less cad cell: control number safety-twitch timing-tecond eph R8184G1005 60 RB184G1021 30 R8184G1013 is cadmium sulfide cell only 3 3-7 7-20 $19.35 17.75 22.35 22.35 13.00 58.20 56.50 50.55 30.55 34.45 34.45 2.40 To substitute T882A* for T822D Thermostat; specify on order control set with suffix "B" and add difference to trade price from above. ___________________________ Accessories ind controls included In tills price boo* ire tor use In conjunction wltn American.SUndsrd products. HH-75-1 Page 34 W See page 48 07642 AMERICAN LaSTANDARD HYDRONIC HEATING hydronic assembling TOOLS PACKAGED HYDRAULIC ASSEMBLING TOOL: All necessary parts to assemble any American-Standard sectional boiler, except long tie rods, shipped in one packing case; the long tie rods are furnished in their own wooden box. Total weight approximately 250 lbs. W Trade Priea - *700.00 HEATRIM COPPER TUBE BENDING TOOL: Designed to bend riser tube connections for Model R Heatvim baseboard panels. Complete instructions for tool use included. W Trade Priea each - *18.50 HEATRIM RISER HOLE TEMPLATE: This tool accurately and quickly lo cates riser hole locations for Model R Heatrim panels. Consists of template (two pieces). 8 ft. steel tape and com plete instructions. Trade Price each -- *3.50 ALUMINUM NIPPLE-SETTING-HAMMER: --consists of a 2 lb. 1'h" diameter aluminum head and a 14" long hard wood handle. The aluminum head will not damage the nipple edges and per mits the heavy blows necessary to set nipples to the recommended depth quickly. yf Trade Price each -- $5.80 SECTION BUMPING BLOCK: -- made of a 6" x 6" x 18" hardwood block with a convenient steel handle for swinging the tool. Its purpose is to bump a section onto the pre-set nipples of the previous section to the recommended depth, prior to pulling the section up. yr Trade Price each - *17.05 So page 48 Page 35 HH-75-) 07643 PACKAGED BOILERS ELECTRIC WATER .--^AMERICAN STANDARD HYDRONIC HEATING PACKAGED ELECTRO-HYDRONIC BOILERS ELECTRA & ELECTRA II ELECTRIC KNTMl HEATING BOILER WITH MTICML UMTT COMTItX E 38076__________ No. ooo ooo ^ Pre-wired for 240 volt, three wire, 60 cycle, single phase service. Designed and equipped with con trols for forced circulation. Tested and equipped for 30 lbs. water working pressure. ELECTRA--WATER packaged boiler number number of elements output watte output btuh amps 9 240 volts T Trsdo Pries with stsndsrd equipment appros. shipping weight EP-34 EP-51 - EP-68 EP-82 2 10,000 34,130 41.7 $541.00 98 3 15,000 51,195 62.4 559.00 99 4 20,000 68,260 83.2 582.00 100 5 24.000 81,912 100.0 X 603.00 102 Output ratings based on 240 volts. Reduce output ratings for other voltages as follows: 230 volts, 8%; 220 volts, 16% ; 208 volts, 25%. ELECTRA II--WATER packaged unit number number of elements EP-7 EP-10 EP-14 EP-17 EP-20 i i i 1 i output wsttt 2,000 3,000 4,000 5.000 6.000 output btuh 6,626 10,236 13,648 17,060 20,472 amps 240 volts 8.34 12.50 16.65 20.81 25.00 Trade Price with standard equipment $270.00 270.00 270.00 270.00 270.00 approx. shipping weight 49 49 49 49 49 Standard Equipment ELECTRA T822D thermostat AT72D low voltage transformer - R8154 sequencing control L4008J adjustable immersion type limit control . Allen-Bradley 836CP11-HKAZS high pressure switch with EP-68 and EP-82 only J. W. Hobbs M4440 low pressure switch 1 %" circulator Expansion tank (diaphragm type) Automatic air vent ASME relief valve Pressure and temperature gauge Drain valve ELECTRA Optional Equipment Sequencer Package: Available for field installation on EP-68 and EP-82 Boilers in addition to regularly furnished sequencing relay. Package con tains all necessary equipment and instructions for the installation of one (EP-68) or two (EP-82) 24A11-4 Sequencer(s) provides a 45 second current delay between the third and fourth elements of the EP-68 or be tween the third, fourth and fifth elements of the EP-82. Standard R8154 relay provides a l/120th of a second (H cycle) current delay between each element. Sequencer PtckM* T TraOa Prfct EP-68 EP-82 $15.55 30.05 Note: Zone valve packages are available for water boilers. For details and prices, see page 33. ELECTRA II T822D thermostat Circulator with piping Drain valve ASME relief valve Pressure and temperature gauge Expansion tank (diaphram type) L4080D immersion limit control J. W. Hobbs M4440 low pressure switch Automatic air vent HH-75-1 See page 48 Page 36 For complete specification* refer to Technical Catalog Bulletin Form No. 2126*2 (Rev 3/70). 315-2 (Rev 4 9/70) 07644 1 AMERICAN kSi STANDARD HYDRONIC HiATINO HEATRIM PANELS MODEL R HEATRIM PANELS SEE CURRENT LITERATURE FOR APPROVED l==R HOT WATER RATINGS iFnr Mod"! P.-75C sr.d V" n-300 ranois) DESCRIPTION ordering numbr paekiftd par MODEL R-750-A COMPLETE ASSEMBLED UNITS (Single Pack) includes 1 each of front and back panel, element, damper, support brackets, slide cradles and 1 set joining pieces. (See Note #1) Finished with white prime paint. All factory assembled. Box Color Coded-Red Orderitf Example: 1-box R-750-A4 R-750A2 R-750 A3 R-750-A4 R-750A5 R-750A6 R-750-A7 R-750A8 per lineal foot 2 ft. length 3 ft. length 4 ft. length 5 ft. length 6 ft. length 7 ft. length 8 ft. length MODEL R-500-A COMPLETE ASSEMBLED UNITS (Single Pack) includes 1 each of front and back panel, *4" element, damper, support brackets, slide cradles and 1 set joining pieces. (See Note M1) Finished with white prime paint. All factory assembled. Box Color Coded-Green Ordering Example: 1-box R-500-A3 R 500-A2 R-500 A3 R-500 A4 R-500A5 R-500A6 R-500 A7 R-500 A8 per lineal foot 2 ft. length 3 ft. length 4 ft. length 5 ft. length 6 ft. length 7 ft. length 8 ft. length MODEL R ENCLOSURE ONLYASSEMBLED (Single Pack) includes 1 each of front and back panel, damper, support brackets, slide cradles and 1 set joining pieces. (See Note #1) Finished with white prime paint. All factory assembled. Box Color Coded-Black Orderieg Example: 1-box R-3-A R-3A R-4-A R-5-A R-6A R-7-A R-8-A R-10-A R12-A per lineal foot 3 ft. length 4 ft. length 5 ft. length 6 ft. length 7 ft. length 8 ft. length 10 ft. length 12 ft. length Trad* Met approx. hipplntf waif $ 2.65 $ 5.30 7.95 10.60 13.25 15.90 18.55 21.20 5 7 9 12 13 16 18 t 2.52 $ 5.04 7.56 10.08 12.60 15.12 17.64 20.16 5 7 9 11 14 15 18 $ 1.30 $ 3.90 5.20 6.50 7.80 9.10 10.40 13.00 15.60 6 8 10 11 13 IS 17 19 MODEL R ENCLOSURES ONLYUNASSEMBLED (Bulk Pack) includes 3 sets of front and back panels, dampers with clips, support orackets, slide cradles and 2 sets of joining pieces. (See Note #1) Finished with white prime paint. Unassembled. Box Color Coded--Blue Orperiag Exempli: 1-box R-5-B R3B R4-B R-5-B R-6-B R-7-B R8B R-10B R12-B For comparative and ettimatmg purposes only. Not* #1: Joining pieces not included on 2 ft. or 3 ft. sections. per lineal foot t 1.17 three 3' lengths thre.: 4' lengths three 5' lengths three'6' lengths three 7' lengths three 8' lengths three 10' lengths three 12' lengths $10.53 14.04 17.55 21.06 24.57 26.08 35.10 42.12 16 21 26 30 35 40 48 58 So* pago *8 Page 37 For complate specifications refer to Technical Cstslnn .........- -prm No. 114S-2 (Re*. 2/T2) HH-75-1 07645 HEATRIM ELEMENTS AND ACCESSORIES ^AMERICAN CaSTANDARD HYDRONIC HEATING MODEL R HEATRIM ELEMENTS ANn ACCESSORIES tfymna^r HEXl DESCRIPTION E-750 (%" tube) ELEMENTS ONLY (Bulk Pack) Individually boxed and strapped into a bundleof six equal lengths. Ordering Example: 1-bundle *750-3 ordering number E-750-3 E-750-4 E-750-5 E-750 6 E 750 7 E-750-8 packaged Pr per lineal foot Trade Price $ 1.43 approi. hipping weight six 3' lengths six 4' lengths six 5' lengths six 6' lengths six T lengths six 8' lengths $25.74 34.32 42.90 51.48 60.06 68.64 9 12 16 18 22 25 E-500 (>.4" tube) ELEMENTS ONLY (Bulk Pack) Individually boxed and strapped into a bundle of six equal lengths. Ordering Example: 1 --bundle -500-4 -500-3 E-500-4 E-500 5 E-500-6 E-500-7 E-500-8 *per lineal foot $ 1.30 six 3' lengths six 4' lengths six 5' lengths six 6' lengths six 7' lengths six 8` lengths $23.40 31.20 39.00 46.80 54.60 62.40 8 10 12 16 19 21 ACCESSORIES End Cap-3" wide-Right Hand End Cap-3" wide-Left Hand Valve Enclosure--4" wide-Right Hand Valve Enclosure--4" wide-Left Hand Valve Enclosure-6" wide-Right Hand Valve Enclosure--6" wide--Left Hand Inside Corner-hinged front and top-90* Inside Corner-back piece-90* Inside Corner-one-piece front and top-135*, 45* Inside Corner-back piece-135*/45* Outside Corner-90* Outside Corner-135*/45* Filler piece set--7" wide Filler piece set-14" wide Wall End Piece--3" wide Return tubing wire hangers Connecting tubing wire hangers Joining piece set-2" wide Extra support brackets with slide cradles and damper clips Tube bending tool NOTE: Finished with white prime paint. RA-ECR-03 box of 10 RA-ECL-03 box of 10 RA-VER-04 box of 10 RA-VEL-04 box of 10 RA-VER-06 box of 10 RA-VEL-06 box of 10 RA-ICF-90 box of 10 RA-ICB-90 box of 10 RA-ICF-45 box of 10 RA-ICB-45 box of 10 RA-OCF-90 box of 10 RA-OCF-45 box of 10 RA-FPS-07 box of 10 RA-FPS-14 box of 5 RA-WEP-03 box of 10 RA-WHR-50 bag of 50 RA WHS-50 bag of 50 RA-J PS-02 box of 20 sets RASBP-20 box of 20 sets For compantive and estimating purposes only. NOTE: Add 25"/ to price when ordering in less than quantities indicated above. $10.84 10.84 14.67 14.67 22.41 22.41 13.38 4.27 13.34 4.07 16.01 16.66 10.80 8.26 5.60 2.67 2.81 9.41 6.93 18.50 4 4 9 9 10 10 3 4 2 2 5 3 9 9 4 -- 5 5 HH-75-1 Sd6 page 48 Page 38 For complete specifications reler to Technical Catalog Bulletin Form No. 1H8-2 (Rev. 2/72) 07646 fail AMERICAN HYDROme^HIATlNO HEATRIM PANELS MODEL SS HEATRIM PANELS, ELEMENTS AND ACCESSORIES SEE CURRENT LITERATURE FOR APPROVED l=B=R HOT WATER RATINGS (For % " Modal SS75 and 1" Model SS-100 Panels) DESCRIPTION MODEL SS-75 COMPLETE UNITS (Dual Pack) Box includes 2 each of front and back panel, element, damper, support brackets and slide cradles and 1 joining piece set (see Note -1). Finished with off-white prime paint. Ordering Example I-box SS-75-4 MODEL SS-100 COMPLETE UNITS (Dual Pack) Box includes 2 each of front and back panel, 1" element, damper, support brackets and slide cradles and 1 joining piece set (see Note -1). Finished with off-white prime paint. Ordering Example: 1-box S5-100-5 rearing SS-752 SS-753 SS-75-4 SS-75-5 SS-75-6 SS-75-7 SS-75-8 SS-100-2 SS-100-3 SS-100-4 SS-100-5 SS-100-6 SS-100-7 SS-100-8 'Trade FHce par linnl foot $ 4.07 *N^lnf weigh* Two 2 ft. lengths Two 3 ft. lengths Two 4 ft. lengths Two 5 ft. lengths Two 6 ft. lengths Two 7 ft. lengths Two 8 ft. lengths $16.28 24.42 32.56 40.70 48.84 56.98 65.12 per lineel foot $ 4.57 14 20 26 33 39 46 52 Two 2 ft. lengths Two 3 ft. lengths Two 4 ft. lengths Two 5 ft. lengths Two 6 ft. lengths Two 7 ft. lengths Two 8 ft. lengths $16.28 27.42 36.56 45.70 54.84 63.98 73.12 14 20 26 33 39 46 52 MODEL SSI -75 COMPLETE UNITS (Single Pack) Assembled Box includes 1 each of front and back panel, element, damper, joining piece set (see Note -1), support brackets and slide cradles. Finished with off- white prime paint. Ordering Example: 1-box SSI -75-7 SSI-75-2 SSI-75-3 SSI-75-4 SSI-75-5 SSI-75-5 SSI-757 SSI-758 per lineel foot $ 4.24 2 ft. length 3 ft. length 4 ft. length 5 ft. length 6 ft. length 7 ft. length 8 ft. length $ 8.48 12.72 16.96 21.20 25.44 29.68 33.92 7 11 14 18 21 25 28 MODEL SSI-100 COMPLETE UNITS (Single Pack) Assembled Box includes 1 each of front and back panel, 1" element, damper, joining piece set (see Note --1), support brackets and slide cradles. Finished with offwhite prime paint. Ordering Example: 1--box SSI-100-6 SSI-100-2 SSI-100-3 SSI-100-4 SSI-100-5 SSI-100-6 SSI-100-7 SSI-100-8 par linaal foot $ 4.73 2 ft. length 3 ft. length 4 ft. length 5 ft. length 6 ft. length 7 ft. length 8 ft. length $ 9.46 14.19 18.92 23.65 28.38 33.11 37.64 7 11 14 18 21 25 28 NOTE #1: Joining pieces not included with 2 ft. or 3 ft. sections. *For comparative and estimating purposes only. See page 46 Page 39 For complete epeclficetions refer to Trhnieei `orm No. 9239-2 (Rev. 1/73) HH-75-1 07647 HEATRIM ENCLOSURES, ELEMENTS AND ACCESSORIES AMERICAN Si STANDARD HYDRONIC HIATI NO MODEL SS HEATRIM ENCLOSURES, ELEMENTS AND ACCESSORIES Commercial baseboard panels designed for hotels, motels, apartments, hospitals, schools and churches. T he SS Heatrim is ideal for residential "hard to heat" areas such as bathrooms, hallways, etc. DESCRIPTION W TmOe MODEL SS ENCLOSURES ONLY (Bulk Pack) Box includes 4 each of front and back panel, damper, sup port brackets, connecting tube wire . hangers and 3 joining piece sets (see Note #1). Fin ished with off-white prime paint. Ordering Example: 1--box SS-8 MODEL SSI ENCLOSURES ONLY (Single Pack) Assembled Box includes 1 each of front and back panel, damper, joining piece set (see Note *1), sup port brackets and connecting tube wire hangers. Finished with off-white prime paint. Ordering Example: 1-box SSI -4 ES-75-8 (%" lube) ELEMENTS ONLY (Bulk Pack) Box includes eight 8 foot lengths of element and slide cra dles. Ordering Example: 1-box ES-7J-8 ES-100-8 (1" tube) ELEMENTS ONLY (Bulk Pack) Box includes eight 8 foot lengths of 1" element and slide cra dles. Ordering Example: 1-box ES-100-8 ACCESSORIES SS-3 SS-4 SS5 SS-6 SS-7 SS-8 SSI-3 SSI-4 SSI-5 SSI-6 SSI-7 SSI-8 ES-75-8 ES-100-8 * per lineel foot t 2.1 S Four 3 ft. length* Four 4 ft. length* Four 5 ft. length* Four 6 ft. length* Four 7 ft. length* Four 8 ft. length* $25.80 34.40 43.00 51.60 60370 68.80 per lineel foot $ 2.37 3 ft. length 4 ft. length 5 ft. length 6 ft. length 7 ft. length 8 ft. length $ 7.11 9.48 11.85 14.22 16.59 18.96 per lineel foot $ 1.98 Eight 8 ft. lengths $126.72 * per lineel foot $ 2.42 Eight 8 ft. length* $154.88 R. H. 214' End Covers (Extend to Floor) ..................................................... ... L. H. 214' End Covers (Extend to Floor) ..................................................... ... R. H. 6" End Covers (Extend to Floor) ................................................. _...... ... L. H. 6" End Covers (Extend to Floor) ......................................................... ... Inside Corner Cover* ............................................................................................ ... R. H. Valve Enclosures with hinged access door.................... _.................. ... L. H. Valve Enclosures with hinged access door........................................ ... Wall End Pieces (Extend to Floor) .................................................................. ... Outside Corner Covers .......................................................................................... 14' Filler Pieces .................................................................................................. ... 2" Joining Piece Sets ............................................................................................ ... Support Brackets, Slide Cradles, Damper Clips......................................... ... Return Pipe Hangers........................................................................... ... Damper Joiners ................................................................................ Connecting Tube Hangers.................................................................................. Ne: Add 25% to prict whon ordering in Itu than quonfitios indicattd above. SS-ECR-25F SS-ECL-25F SS-ECR06F SS-ECL-06F SS-IC-90 SS-VER-06H SS-VEL-06H SS-WEP-2SF SS-FPS-14 SS-JPS-02 SS-SBP-24 SS-WHR-50 for comparative and estimating purposes only. Note #1: Joining pieces are not included with 3 ft. sections. Box of 12 Box of 12 Box of 12 Box of 12 Box of 12 Box of 12 Box of 12 Box of 12 Box of 4 Box of 6 Box of 24 Box of 24 Box of 50 Box of 50 Box of 50 $18.70 18.70 22.70 22.70 9.35 40.05 40.05 6.65 16.05 16.05 6.70 13.30 6.65 5.00 8.00 ***. 31 42 52 63 73 84 11 14 18 22 25 29 42 48 9 9 7 7 5 13 13 4 5 14 4 10 1 1 3 HH-75-1 See page 48 Page 40 For complete specifications rofsr to Technics! Cetslog Bulletin Form No. 9230-2 (Rev. 1/73) 07648 _ AMERICAN STANDARD HYORONIC HEATING CONVECTORS MULTIFIN CONVECTORS TYPE K - STOCK MODEL - FREE STANDING Expanded prices For use on two-pipe steam and hot water systems only. ttbiMI No. 4 depth (4Vi" cabinet) wait U *e * MIRVt IM'H. Tr4 hipP'M viM Fri< 20" cabinet height No. 6 depth (6Vi* cabinet) No. S depth (8Vi* cabinet) No. 10 depth (10Vi* cabinet) nit M. nh vfpwl ih'PRiM Tre< Fric iykf Mif T4. a*. ""'j ..(U Friis Mit N. e Hl|t ppa<ee>M Tfe* frill 20 420-20 24 424-20 28 32 36 40 44 48 56 64 10.6 13.0 18 S29.08 620-20 14.9 21 (32.29 20 30.88 624-20 18.4 24 34.87 628-20 22.0 27 37.53 632-20 25-S 29 40.19 832-20 31.7 33 $44.79 636-20 29.0 33 40JQ 836-20 36.0 37 47.99 1036-2Q 45.5 42 640-20 32.5 34 45.39 840-20 40 4 39 51.25 1040-20 51.2 48 644-20 36.1 37 48.05 648-20 39.6 40 50.71 848-20 49.2 46 57.84 1048-20 62.3 52 656-20 46.7 45 55.98 856-20 58.0 51 64.42 1056-20 73.4 58 664-20 53 B 52 61.30 864-20 669 59 71.02 1064-20 84 5 64 (55.10 59.30 67.62 75.87 84.12 24" cabinet height 20 420-24 24 424-24 28 428-24 32 36 40 44 48 56 64 12.1 20 (30.22 620-24 17.2 23 $34.01 14.9 22 32.29 624-24 21.2 26 36.94 17.8 25 34.41 628-24 25.4 30 40.06 632-24 29.5 33 43.20 832-24 35.6 38 (47.72 636-24 33.5 35 48.12 836-24 405 40 51.38 1036-24 49.0 45 640-24 37.6 38 49.19 840-24 45.5 44 55.10 1040-24 55.2 52 644-24 41.7 42 52.25 648-24 45.7 44 55.24 848-24 55.4 50 62.43 1048-24 67.1 62 656-24 539 50 61.36 856-24 65.2 55 59.74 1056-24 79.0 64 664-24 62.2 57 67.55 864-24 75.3 63 77.28 1064-24 91.0 ` 71 $57.71 62.29 74.51 80.07 86.98 32' cabinet height 20 620-32 18.7 29 (35.08 24 624-32 23.1 32 38.40 28 628-32 27.7 36 41.79 .... ....32 632-32 32.1 40 45.12 832-32 40.9 45 (51.65 36 636-32 36.5 43 40.39 836-32 46.5 48 55.85 1036-32 55.0 54 $62.16 40 640-32 41.0 48 st.n 840-32 52.2 56 60.10 1040-32 61.9 59 67.29 ....44 644-32 45.4 56 54.97 48 648-32 49.8 58 58.30 848-32 63.6 65 68.55 1048-32 75.3 69 77.28 56 656-32 58.7 67 64.89 856-32 74.9 73 77.00 1056-32 88.7 76 67.25 64 664-32 67.8 71 71.88 864-32 86.5 76 85.66 1064-32 102.2 84 7.37 Plugs and bushings are not regularly furnished with Multifin Convectors, but are available for separate sale. ^4" 1" 1V4" Trade Price Each $.36 Nate: For stock model cabinet extras, see page 41. Orderisj Exanple: 1-K-U6-32 Multifin. V See page Page 41 For complete specifications refer to Technical Catalog Bulletin Form No. 162*2 (Rev. 6 10/69) HH-75-1 07649 CONVECTORS .--I AMERICAN kSJ STANDARD HYDRONIC HEATING MULTIFIN CONVECTORS 0* -- _ A Nri_Kt ,., The actual output in square feet of catalog rating-Steam (215*F.) obtained with the cabinet heights furnished determines the price of convectors and cabinets sold in combination. The total price of each order equals the amount of catalog square feet ordered multiplied by (he price per square foot, plus the unit extra charge multiplied by the total number of units Ardered. SEE CURRENT LITERATURE FOR STEAM AND HOT WATER RATINGS cabinet tv* description Trad* Prte* *r unit *trs *4 ft charg* Stock Model K Floor Type-free standing.......................................................... S.75 $21.18 Not*: Price jhoum for estimating purposes only. For expanded prices, see page 38. For cabinet extras, see page iJ- Special Service F FG W FS FSG S FR FRG FRGB PR PRG PRGB Floor Type-free standing.......................................................... Floor Type-free standing-inlet grille.................................... Wall Hung-flat top..................................................................... Free Standing-sloping top--inlet grille.................................. Wall Hung-sloping top.............................................................. Fully recessed-^," beveled edges........................................... Fully recessed-Xt" beveled edges-inlet grille.................... Fully recessed-Xa" beveled edges-inlet grille with bottom overlap and liner bottom............................................ Partially recessed-1 V4", 2V4", 3", 5" flanged edges........... Partially recessed-1 Vs", 2V4", 3", 5" flanged edges-inlet grille .............................................................................................. Partially recessed-1 Vi", 2 Vi", 3". 5" flanged edges-inlet grille-with bottom overlap and liner bottom.................... $ .89 .89 .89 .84 .84 .84 .91 .91 .91 .94 .94 .94 $25.66 29.49 25.66 27.07 30.90 24.39 27.07 30.90 34.02 31.33 35.01 44.94 HH-75-1 "W See page 48 Note: For cabinet extras, see page 41. For estimating purposes only, the following approximate shipping weights per sq ft may be used for Multifin convectors: Multifin stock model -- 1.13 pounds. Also see page 38. Multifin cabinets (less element) - ltt pounds. Multifin cabinets (with element): Types F. FR, PR -Impounds. Types FS, W -- 1V4 pounds. Type S -1 Vi pounds. Orderiag Usaplit: Stock Model Multifin with an optional feature: 1 K-840-24 Multifin with Metal Trim Strips. Special Service Multifin with an optional feature: 1 PR-S40-32-2W Flange, Multifin with Knob Damper. Page 42 For complete specificaiiona refer to Technical Catalog Bulletin Form No 162-2 (Rev 6 10/69) 07650 (AMERICAN SiSTANDARD HYDRONIC HEATING MULTIFIN CONVECTORS - continued CONVECTORS eonvoctor langth Inch** 20 24 28 32 36 40 44 48 56 64 Elements only (when sold less cabinets)-- two-pipe steam or hot water No. 4 depth No. 6 depth No. 8 depth No. 10 depth approx. unit hipping Trad* no. weight Met approx. unit hipping Trado no. woight Prlco approx. unit hipping Trad# no. walght Prtco approx. unit hipping Trad# no. walght Prtco 420 424 428 432 436 440 444 448 456 464 8 SI 6.78 620 13 820.57 820 15 $24.30 1020 10 18.17 624 16 22.57 824 19 28.08 1024 12 19.57 628 19 24.56 828 23 30.09 1028 14 21.03 632 22 26.29 832 27 32.75 1032 16 22.84 636 25 28.29 836 31 35.67 1036 18 24.58 640 28 30.69 840 35 38.20 1040 20 26.22 644 31 32.75 844 39 41.06 1044 22 27.75 648 34 35.00 848 43 43.73 1048 26 30.88 656 40 39.00 856 51 48.85 1056 30 34.14 664 46 43.46 864 59 54.11 1064 Note: Elements only are furnished less floor supports. Multitln elements (or specie! one-pipe tleam header application--not available. Orderiag Example: 1-420 Multifin Element only--no cabinet. 21 26 31 36 41 46 51 56 66 76 827.95 32.42 36.15 39.67 43.79 47.26 50.58 53.77 59.90 67.22 Ratings: Ratings of Multifin Convectors have been determined in accordance with the method of testing and rating outlined in Commercial Standard Code CS140-47 and amendments and said ratings have been approved by the Convector Rating Committee. Standard Cabinets: Standard cabinets are furnished in prime painted sheet steel--reinforced, No. 18 gauge front and No. 20 gauge back, ends and top, rounded corners, front discharge grille, and open bottom inlet, in heights, lengths and depths to accommodate convectors as currently catalogued. HH-75-1 MINIMUM CABINET HEIGHTS WITH DAMPERS FOR MULTIFIN Type cabinet F.FG W FS, FSG S FR, FRG, FRGB PR, PRG, PRGB Muttlfln 20" For all depths 20" For all depths 20" For all depths 20" For all depths 20" For all depths 20" For all depths Cabinet heights shown for types W and S are nominal heights, actual heights are S' less. Page 43 For complete specifications refer to Technical Catalog Bulletin Form No. 162*2 (Rev. 6 10/69) W See page 48 07651 CONVECTORS (AMERICAN k2iSTANDARD HYDRONIC HEATING CABINET EXTRAS FOR MULTIFIN CABINET EXTRAS-STOCK MODEL MULTIFIN ONLY ITEM DESCRIPTION DAMPER Knob Operated Damper Package ....................................... ............... each METAL TRIM STRIPS For recessing stock models only 20" to 36" long ........................................................................ 40" to 64" long ........................................................................ ............... each GRILLE AIR VENT Snap-on Inlet Grille for Stock Models Only .................... Air chamber with extended tube, manual vent ............... Air chamber with Dole No. 20JR auto-vent ...................... *Not: Items also availabl* for special service Muhifm. Trada Prict t 7.33 12.58 16.10 5.59 7.13 7.13 SPECIAL SERVICE CABINET EXTRAS--MULTIFIN (Prices indicated are for standard catalogued sizes only) ITEM DAMPER DESCRIPTION Knob or Institutional Type ...................................................................... each Trad* Pric* 5 8.72 ACCESS DOOR In standard locations Ir 2, 3, 4, 7 or 8 as shown in current literature. Hinged type with Slotted Head operator ............................................. each Hinged type with Allen Head operator ................................................. each Note: Access doors in other than standard locations 8.72 10.38 Pnce on application TAMPER PROOF SCREWS Phillips or Allen Head screws (other than standard Slotted Head) per cabinet 1.41 CAM LOCKS Allen Head Cam Locks (Allen Keys Not Furnished): Types F, FG. FS and FSG......................................................... per cabinet Types S and W (MultifinOnly) ............................................... per cabinet Types FR. FRG. FRGB, PR, PRG, PRGB Note: Additional charge per order $6.29 f t0,48 .......... per P 7.18 7.18 31.68 39.67 INSULATION hi" Celotex or Fibreglas on outside of cabinet Back only...................................................................................... per cabinet Back, ends and top....................................................................................... percabinet hi" Millboard on outside of cabinet Back only....................................................................................... per cabinet Back, ends and top....................................................................................... percabinet 14.77 18.24 34.61 49.19 SOUND DEADENING MATERIAL Approx. V4" thick-inside front panel only................................ per cabinet 14.64 SEALING STRIP For standard length FR, FRG and FRGB cabinets only CV" x %" Polyurethane) ......................................................... per cabinet 6.13 STIFFENER All fronts 48" and longer, or 82" and higher have stiffening channel spotwelded to inside front in horizontal position at no additional charge. Stiffening channel on fronts other than standard ............................................................................................. per cabinet 2.07 METAL TRIM STRIPS For recessing Types F and FG Multifm convectors only Cataloged heights and lengths up to 36'........................................... each Cataloged heights and lengths 40" to 64"......................................... each 14.11 17.38 END POCKETS KNOCKOUTS Specify right or left hand side 4' end pocket with No. 18 gauge vertical baffle............ per end pocket 8' end pocket with No. IB gauge vertical baffle.............. per end pocket Are optional-Furnished only on request 7.85 12.58 Pnct on application HEAVIER GAUGE CABINETS . Trade-Price per square foot of cabinet output Front Only No. 18 gauge......................................... No. 16 gauge......................................... No. 14 gauge.......................................... -- $.10 .19 Unova Only 5.10 .12 -- HH-75-1 See page 48 Page 44 For complate specifications refer lo Technical Catalog Bulletin Form No. 162-2 (Rev. 6 10/60) 07652 HYDRONIC HEATING GENERAL INFORMATION BOILER RATINGS The net I=B=R boiler ratings represent the maximum net loads that may be connected to the boilers. The net I=B=R steam ratings are based on a piping and pickup allowance of 1.333 except where an appropriate piping and pickup column is shown. Steam-sq. ft. ratings are based on 240 Btuh per sq. ft. The net 1=B=R water ratings in Mbh are based on a piping and pickup factor of 1.15. Water sq. ft. ratings are based on 150 Btuh (170* water) per sq. ft. For installations having unusual piping and pickup requirements, AmericanStandard should be consulted before selecting a boiler. For forced hot water heating systems where the boiler and piping are within the area to be heated, the boiler may be selected on the basis of its gross output. Sufficient radiation must be installed for the requirements of the building to be served. In order to select the proper size boiler, calculate the heat loss of the building, then divide this figure by 1,000 to get the heat loss expressed in Mbh. Select a steam or water boiler which has a net I=B=R Mbh rating equal to or greater than this figure using the appropriate steam or water column. GAS FIRED BOILERS American-Standard Gas boilers are design certified by the American Gas Association. Ratings shown are for installation at sea level and at elevations up to 2,000 feet. For altitudes above 2,000 feet, ratings should be reduced at the rate of 4% for each 1,000 feet above sea level. OIL FIRED BOILERS The firing.rates or I=B=R burner capacities -- gallons per hour--are based on the use of oil having 140,000 Btu per gallon heat value. BUILT-IN TANKLESS WATER HEATERS for G-2 Wafer, G-40, G-IO, V-3, V-3M, FR-A-S, A-S, DPT, PFA-3, PFA-5, and VPT All tankless type built-in water heaters are rated in gallons per minute on the basis of a minimum boiler water temper ature of 200* F. The maintaining of 200* F boiler water temperature with rated flow through a tankless type builtin water heater is dependent on the output of the boiler. Increase the boiler size 12 Mbh for each bathroom in excess of two. In those areas where excessive liming conditions exist in the water, use of built-in tankless type water heater is not recommended except when provision is made for reg ularly cleaning the heater. EXTERNAL WATER HEATERS FOR AMERICAN-STANDARD STEAM BOILERS External tank or tankless type heaters can be connected to all American-Standard Steam boilers when provision is made in the supply and return piping of the heating system. When an external tank type heater is used and the domestic demand exceeds 75 gallons in a 24 hour period, increase the boiler size 120 Btuh for each gallon of storage tank capacity. When an external tankless type heater is used, increase the boiler size 12 Mbh for each bathroom in excess of two. (Note: G-10 Steam boilers can be provided with external water heater tappings for water to water heat exchangers. See G-10 optional eauipment pages for price and availabil ity. INSTRUCTIONS FOR ORDERING GAS BOILERS: Specify complete boiler number. Specify type of gss (whether natural or propane), Btu (heat value of gas), specific gravity. Specify elevation at point of installation if in excess of 2,000 feet and indicate barometric pressure. In odditian, for Pressure Fired PFA-J pas Fired and gas-ail fired units, specify gas pressure at gas train inlet. Specify optional equipment in detail. BOILERS: REPAIR PARTS For current price, contact your American Standard distributor Refer to Boiler Repair Parts Catalog Form 9100-2 & Revisions for Current Repair Parts Obsolete and Discontinued Boiler Repairs are available thru: H. C. Oswald Co. 120 E. 124th St. N.Y.C., N.Y. 10035 OIL BURNERS:.......................................................................................................................... Refer to "American Standard Oil Burner Repair Parts Catalog" 73197-2 dated July, 1974 See page 43 Page 45 HH-75-1 07653 I AMERICAN 12< STANDARD HYDRONIC HEATING NOTES o HH-75-1 See page 48 Page 46 o 07654 IAMERICAN kSiSTANDARD HYDAONIC HEATING NOTES See page 48 Page 47 HH-75-1 07655 * ' GENERAL TERMS F.O. IOX MO). NSW ItUMSWlOC. N.J. OOfO) TRADE PRICE BOOK Illustrations and descriptions of ordering Numbers listed In this price book will be found In the current American-Standard Hvdronic Products Catalog and literature. Items Illustrated In product literature and not included in this price book are discontinued. The illustrations In this price book although actual representations of certain products In the line, do not necessarily show sizes and details of all products In the line. ^This price list has been prepared for the convenience of American-Standard distributors and their trade customers only. The trade prices shown are guides only and do not purport to represent actual prices prevailing In any particular market and are not Intended to interfere with our distributors* right and responsibility to establish their own resale prices. All prices herein set forth supersede all prior price lists and are subject to change without notice. The Seller may also, from time to time, discontinue without notice the sale of any of the products listed herein. INVOICE MINIMUM All distributors' orders. Including repairs, which aggregate less than $25.00 net will be billed at $25.00. TERftlS AND CONDITIONS APPLYING TO ALL SALES OF GOODS BY AMERICAN-STANDARD THROUGH U.S. PLUMBING/HEATING TO ITS DISTRIBUTORS All sales of goods by American-Standard through WH Plumbing/Heating to its distributors are made subject to terms and condition* printed below, in its bulletins and on its acknowledgment of order, invoice and quotation forms. These terms and conditions, are as follows: MICC Goods sold by the Sailor will bs bitted to N Buyer according to tho prices snd terms contained in its currant bulletins and price books. In tho case of ordars for goods for which no prioa la currently In affact tha price will be determined by (ho Seiler and set forth in tho tovoioo issued after shipment of the goods. Tate Any tax or ether Government charge now or horesftor levied upon the production, sate, use or shlnmept of goods ordered or sold, wilt bo charged to and paid for by tha Buyer. DELIVERY Transportation ftMea. Delivery to tho initial carrier shall constitute delivery to tho Buyer. The Seller's responsibility ceases upon delivery in good order to such carrier, and eU goods are shipped at tha Buyer's risk. The Buyer la urged to examine all deliveries carefully before signing transportation receipts. If goods are vtalbfy damaged, tha Buyer should insist that written confirmation of tha damage be noted on the freight bill or dray ticket by tha agent of tha carrier. If damage it discovered after unpacking, the carrier should be notified at once, so that inspection ean be made snd the claimed damage substantiated by the carrier. Interference witi Delivery. The Salter has no obligation to delirer goods against any order until it has accepted the order by issuance of its acknowl edgment of order. In any event the Seller will not be liable for any delay or failure in the delivery or shipment of goods against an accepted order or for any damages suffered by reason thereof, when such delay or failure, is, directly or indirectly, due to accident (in manufacture or otherwise), fire, flood, riot war, embargo, labor stoppages. Inadequate transportation facili ties, shortage of material or supplies, delay or default on tha part of its vendors, regulation by Government authority, or any* Hite or dissimilar cause beyond Its control. CONSUMER PROTECTION - WARRANTY American-Standard products normally reach owners or consumer-users through an industry channel of distributors and plumbing and heating con tractors. Experience has shown that deists of defects in our products gam erally relate to abuse or to other damage which occur after our sole and are not our responsibility. Since determining proper responsibility requires local inspection, our warranty (sot forth below) extendi onfy to our direct buyers; distributors are boat equipped to obtain tie facts underlying claims, to place responsibility where H belongs and to recommond/handte repair or re placement. Sinoe local code requirements vsry greatly throughout the country, users of heating products should consult in advance with licensed contractors to determine whether there are any coda restrictions on tha use of a specific product. American-Standard makaa no representation nor warranty regarding, and shall not be responsible for, any coda compliance. American-Standard is proud of Its record for product quality and for fair ness in handling warranty matters; and, if an ultimata user of our products should feel our warranty system described above does not wort fairly in his case, he should writs (ha Office of the President, Director of Consumer Affairs. W. H. Plumbing/Heating. American-Standard. Box 200). New Brunswick, New Jersey 0890). CONTRACT WITH BUYER Acceptance of Orders. Orders will be accepted only by the Seller's usual acknowledgment of order containing terms and Conditions applicable thereto. No terms and conditions appearing in a Buyer's order that are at varianca with tfie Seller's terms and conditions shall ba binding upon the Seller unless specifically agreed to by it in writing. Unless tha Seller spe cifically so agrees in writing in acknowledging any ordsr, any terms and conditions appearing in a Buyar'a order contrary to thoae statsd herein and n such acknowledgment of order are to be deemed waived by tha BuyerReceipt by the Buyer of the acknowledgment of order without prompt objec tion to the terms and conditions therein and hsrain sat forth, constants acceptance by the Buyer of such terms and conditions. Cancellation of Orders. Artec the Seller's acknowledgment of order has been issued, an order may ba modified or cancelled only upon written agreement by die Seller. Orders for goods othar than thoae of standard manufacture will not be cancelled after a commitment has bean made or production scheduled. Credit ter Returned Goode. Merchandise may not be returned for credit unless the Salter has agreed to accept it. Where returns are accepted, a deduction of 20% or $20, whichever is greater will be made for rehandling All transportation coats for returned goods must be paid by the Buyar. in any event, only saleable merchandise of standard manufacture may be returned for credit CredH Approval. Buyers' orders are accepted subject to credit investiga tion and approval, and delivery may be withheld or shipment stopped in transit on accepted ordars without any liability on the Sailer's part. if. in its opinion, tha Buyer's ability to pay tor the motehondlao on these terms and conditions to in doubt SHORTAGE* OR VARIANCE* American-Standard warrants only to its distributors snd other Direct Buyers thst. at its option. It will furnish by freight s replsesmsnt tor, or repair, or refund the purchase price paid by its distributor or other direct buyer, for any product of its manufacture or pan or portipn thtreof, proved to Its satisfaction to be defective in material or workmanship under normal use and service within one year after installation. In no case will American-Standard (ba responsible for any special, direct, in direct or consequential damages, nor for labor or transportation ex panses relating to such replacement or repair, nor will it be held re sponsible for werrsnty ad|ustments costing more than the price of the product to its distributors snd other Direct Buyers. There la no oflier warranter express or Implied, fnchidteg no implied warranty of merchantability or knplted warranty ter fitness for a particular purpose. No claims for variances from or shortages in ordars will be considered unless presented whhln 60 days after receipt of goods. MODOCT AND PACKAGING CHANGES Factors beyond the control of the Seller and tha need tor continuing im provement of product require the making of changes from lima to time in products and their packaging. Tha right la reserved to make reasonable changes of any kind without notice and to deliver revised designs or models of goods against any order, unless on flte tees of the acknowledgment of order this right la specifically waived. The Seiler shall have no responsibility whatever with reaped to changes made by the manufacturer in products or their packaging sold but not manufactured by the Setter. Goods of eater manufacturers ooM by American-Standard are not wanwriad unteea accompanted by an axpraes written warranty, but the Salter will endeavor to secure for tea direct Buyers the benefits of warranties extended by such other manufacturers for such goods. SNIPPING WEIGHTS Tha shipping weights given herein are approximate, for Buyers' con venience only, snd are net guaranteed. * AMERICAN STANDARD Inc. HH-75-1 Page 48 07656