Document KpwDr8Q8qMReL262dGr3bm6Q
V ^V
--i
'fllF. TKAVLI.F.HS INSURANCE CO.MI7VNY THE TRAVELERS INDEMNITY COMPANY
r ~i
Hr. S. E. Monoky, Environmental Control & Safety Co-od, Certain-Teed Products Cornoration Valley. Forge, Pennsylvania 19li8l
Addrew oil correspondence To
THE TRAVELERS COMPANIES Engineering
3 Parkway Phila., Penna. 19102
IOCaiion OF rrriwSIS. ;
^'
Asbestos Cement Pipe Plant Ambler, Pennsylvania (CODE 1058)
fTVsON WIIM WHOM nSUUs'of' SUvEr"wiVfdlSCUSSfD
Mr. Bill Hagers, Safety Supervisor
SUIVET KELATED TO COVSCAGES INOICAItDi
Dust Analysis
| Date Of SURVEY
DATE Of CONHtMAItON
12/3-9/71
rtODucfi
1/2U/72
Johnson & Higgins of Pennsylvania
Dear Steve:
Enclosed are the results of the dust survey made at the Ambler pipe plant dur ing the period 12/3/71 to 12/9/71. I have also enclosed copies of the actual survey sheets preoared by Bill Hagers, so that you can determine the exact lo cation where each survey was taken and the duration of time that the employee wore the dust sampling equipment.
The equioraent used to obtain these dust samoles was the Unico C-110 Pump with personal Respirable Dust Samoler. This equipment is used to detect respirable dust and is approved by the Environmental Health Service and the Bureau of Occupational Safety h Health. Dust samples were obtained in the area of the breathing zone of the employee and as the survey sheets indicate the sampling equipment was worn an average of four hours so that an accurate samole could be obtained indicating the exposure to the employee on the particular day of the survey.
The threshold limit value for dust containing less than 1^ free silica is 10 milligrams per cubic meter. You will note that all samples collected are substantially below this figure.
The threshold limit value for asbestos in air is 5 fibers per ML and our analysis of the samoles taken indicate that all asbestos counts were less than 5 fibors per ML.
On the basis of the sampling performed on these particular days we do not find an excessive amount of dust in the air, however, you realize that conditions may change from day to day and we may not have detected the worst condition. From the many visits I have made to the Ambler pipe plant I do feel that wo may consider these samples to be representative of the average condition found at this plant, and may be considered representative of the average condition of the air that workers in the particular area breathe.
trpott ft ho *+d upon
ond p<OCfi(M uliArrvfU onj information s I'.vp / ltd b* njnni;r>>.nl pc r
I >t tl\C
doei *> purport 10 /* all hatatJt not to
rKor
horott/% do no* ri>l. Inspect ions urn/ rfcnmmrnoni.onf map
otr od+HOtf and dein'nrd to otlill msoredl in the * t loitl <\hmcnt and mpmirnonce ol their own >olrl^
The T
tCStions ilnhtir t W.III Iijnuxil Oml Control of
Otloilifi not lot ttir (O'FfrliOrt ol the conditions pointed Ou< lirrfin
REV. 10*70 MiNfCO in W.J.fc.
CTD006807
k-
Certain-Tced Product Corp. Valley Forge, Penna. 19l8l
l/2h/72 Page 2
If there are any questions concerning the results of this dust survey, please do not hesitate to call this office.
Sincerely,
LJW/mw
DISTRIBUTION* 1 2 Orig. & "j* - as shown
1 cc. 2 cc, 2 cc.
- Certain-Teed Products Corp. Insurance Department Valley Forge, Penna. 19h8l
- Johnson & Higgins Casualty & Loss Control Dept. 120 South 17th Street Philadelphia, Penna. 19103
- File
\ CTD006808
I
t-' '-VrJ.1 210 V.-AJHINOUIM SIRLTT, HARTFORD. CONNECTICUT Of ICS
203 527-itOt
Chemical W'
Lahornloiy
REPORT OF ANALYSIS
CLlEJ]T._____ Certain Toed Prod. Corp.
ADDRESS:.
Ambler, Pa;
Wilms
SA.V.P-E SENT DY:_____
sample DEscP'OTiow___ Rcspirnblc/Dust r
ANALYSIS NUMBER:.
71C3100S
DATE RECEIVED:DATE REPORTED;-
12/14/71 1/3/72
analyst:______ M. A. Geoffroy
Results:
A. Dust, SiOz-
#3 - Coupling Mill - less than 1 7. free SiO . . Less than .02 mg/M^
#6 - Cut-off Saw - less than 17. free SiO,. Less than .02'mg/K i19 - Scrap Crusher - less than 1% free SiO-. Less than .02 mg/M3
^3 #11 - Finishing Dept. - less than 17. free Si0. Less than .02 mg/M
^3 #12 - Chicks Mill Couplings - less than 17. free SiO . Less than j02 rag/M
^3 #13 - #3 Line Lathe Operator - less than 17. free SiO-. Less than .01 mg/M
^3 #15 - Mixing Hopper - less than 17. free SiOj. .06 mg/M dust. #16 - Coupling Cut-off Saw #9 - less than 17. free Si0n. Less than .02 ng/K3
B* Asbestos Count S3 - less than 1 fiber per ml SO -- less than 1 fiber per ml $9 - less than 1 fiber per ml
#11 -- less than 1 fiber per ml #12 - less than 1 fiber per ml #13 - less than 1 f iber par n] #J 5 - less than f iber per ml flu - less than 1 fiber per ml
*^n
U.iluifil hi (hr t iiriii'r* /;*'
CTD006809