Document KZ8k5ak5wLQkbdaq9R6yKEjX
Federal Register / Vol. 51. No. 119 / Friday, June 20, 1986 / Rules and Regulations
22687
sampling strategies be designed to yield samples with fiber densities of at least 80 fibers per 100 fields when using the NIOSH 7400 method.
Intralaboratory Variability
NIOSH's statistical analysis of the Johns-Manville analytical data, and the resulting estimates of the precision of the P&CAM 239 method, were criticized by rulemaking participants, who believed NIOSH's estimates to be too low (Ex. 91-16, Tab D; 91-10, Tab E, 232B. 233-B, 328; Tr. 7/6, p. 66). In summarizing the record evidence on intralaboratory variability, which was . one of the three sources of variability included in NIOSH's overall estimate of precision for the method, the A1A concluded that ", . . NIOSH should . . . recognize a more reasonable CV value in the range of 0.2 to 0:3--a range which accords with the remainder of the evidence in the record on the best achievable total intralaboratory error" (Ex. 128. p. A-15). In arriving at this conclusion, the A1A relied on the following evidence:
Testimony from Dr. Ogden sleting that he had achieved intralnboratory CV's of approximately 0.2 in British laboratories.
Analysis of the Johns-Manville data by Dr. Patrick Crockett, who projected a CV of oyer 0.31 for a total fiber count of 100.
The study of the P&CAM 239 method by Chase and Rhodes (Ex. 86-002). who reportedan inlralaboratory CV of 0.38 fora total fiber count of 100.
. OSHA-has analyzed the evidence presented by the ALA and finds that these data do not necessarily refute NIOSH's estimates of the CV for samples analyzed by the P&CAM 239 or NIOSH 7400'methodB. In fact, the evidence of Dr. Ogden cited by the AIA .closely parallels the results obtained by. Busch et al. (Ex. 84-62. Appendix C). Or.. Ogden examined inlralaboratory variation among technicians analyzing 66 asbestos-samples in British Health and Safety Executive (HSE) laboratories* (Ex.,84-447). In this testimony about this work. Or. Ogden stated, that his. investigation,, as,well as- those from . other laboratories, -resulted- In estimated intralaboratory CV's similar to the estimates obtained in the NIOSH study:
There is a lot of evidence from different ' laboratories that repeated evaluation of the . same asbestos-loaded membrane filter by the same counter, or by different counlers'closely linked within a laboratory, can give a. coefficient of variation ofbelween 10 and 20
percent. .... Figure 1 (from Ex. 84-447| demonstrates
results in our laboratory of a detailed study of one year's quality, assurance results. ... On the vertical axis we haVe.the coefficient of variation of the repeated determination.
and on the horizontal axis, we have-the^mean number of fibers counted in that sample:.......
Since coming to the United States 1 have plotted the results on the seme axis which were published by (Busch ct al.] .... If we
superimpose those: you can see they lie in very much the same kind of area. (Tr. 6/20, pp. 6-7)
"100 fields'' stopping rule of the set A rules (i;e., for samples with a fiber density of less than 1 fiber per field. 100 fields must be counted, and for samples with a fiber density of more than 5 fibers per field, 20 fields must be counted). For samples with fiber densities between 1
Dr. Ogden's estimate of 0.2 as an average CV representing inlralaboratory variability is a consequence of his use of a minimum fiber density of 50 fibers per 100 fields, in contrast with NIOSH's recommendation in the 7400 method that a minimum fiber density of 80 fibers per 100 field be used, which yields an estimated CV of 0.15. Therefore, OSl-lA finds that Dr. Ogden's results actually confirm NIOSH's estimates of the intralaboratory coefficient of variation for asbestos samples analyzed by phase contrast microscopy.
The AIA also relied on the analysis
performed by Dr. Crockett (Ex. 312-A.
Tab P) of the (ohns-Manville data to refute NiOSH's estimate of the precision or the P&CAM 239 method (Ex. 328. pp. A-12 to A-15). The AIA explains Dr. Crockett's analysis as follows:
Dr. Crockett identified and plotted . . . more than forty data points that were excluded from the NIOSH analysis. ... In the very important range of 80 to 100 fibers
and 5 fibers per field, the NIOSH "A"
rules require that enough fields be
counted to yield 100 fibers. According to
Busch et al. (Ex. 84-62. Appendix C. p.
75), calculating the overall CV for
samples counted using the "100 fibers"
stopping rule rather than the "100 fields"
slopping rule cannot be done unless
additional statistical techniques are
developed, although "indications are (-
that the TOO fibers'stopping rule
|would| yields a CVT similar to that for
the TOO fields' stopping rule when 100
fibers are counted" (Ex. 84-62, p. 75).
Both because of the uncertainty
surrounding the calculation ol a CV for
samples counted using the 100 fibers
stopping rule, as reported by Busch (Ex.
84-62, p. 75), and because the Johns-
Mnnville data were appropriately
;
excluded from the NIOSH analysis.
OSHA disagrees with Dr. Crockett's
contention that NiOSH's estimated CV
is unreliable.
The final study cited by the AIA to
counted, only six or seven of the eighteen data points (in this range] were Included and the included points represented dramaticnliylower CV estimates than the excluded ' points . . .'.
When Dr. Crockett applied a close
reproduction of the NIOSH statistical method
to-the entire Johns-Manville data set, his projected CV for a total-fiber count of 100
support its contention that the inlralaboratory CV associated with the P&CAM 239 method is higher than that estimated by NIOSH is the round robin study by Chase and Rhodes (Ex. 66-002). which reported a random inlralaboratory CV of 0.38 for a total fiber count of 100. According to the AIA:
w'as over 0.31. about three times as high as NiOSH's result based.on incomplete data. In any event, the published NIOSH method does hot represent the original Johns-manville data base, but instead reflects only a subset of that database with much of the high variability data deleted. (Ex. 120. pp. A-13 to A-1.4)
This study included virtually allrelevant error sources and of the studies in the record, is the most representative of everyday . American experience with P&CAM 239 and commonly encountered workplace samples, and should be accorded significant weight by OSHA. (Ex. 328, p. A-li)
When questioned as to why NIOSH eliminated some of the data points in the analysis, Ken Busch of NIOSH replied that these data were excluded because they were outside the fiber density range permitted by-the "A" rules:
I'm absolutely certain that there.was.no intent to eliminate counts which would be the cause of high variability. The elimination of counts . . . which were based on large numbers of fibers was simply because this
AIA did acknowledge that the study may overstate the magnitude of the "best achievable inlralaboratory CV" because of the absence of quality
control programs in some of the participating: laboratories, and because. some of the samples analyzed were difficult to count (Ex. 328, p. A-ll, Footnote 17). The lack of quality control programs, as evidenced.by the . participation in the NIOSH PAT
procedure of counting more than 100 fibers
program of only 19 of the 46 laboratories
did not correspond to the standard procedure . included in the study, was one reason
for the NIOSH method. (Tr. 6/21. p. 192)
suggested by OSHA in the November
In addition, the statistical model
proposal (48 FR 51136) for the Chase and
developed by Busch et al. (Ex. 84-62,
Rhodes study's, higher reported CV.
Appendix C) was developed to estimate the relationship between CV and
number of fibers counted. As such, the
OSHA also believes that the design of the Chase and Rhodes study is deficient. The authors collected and analyzed a
model can only appropriately be applied total of l.774 full-shift samples, of which to samples that were counted using the 541 were submitted for a second
GLEASON-000935