Document KY15meBDvrqooLRVO2R1d4NQ

FILE NAME: Asten Hill (AH) DATE: 1950 DOC#: AH005 DOCUMENT DESCRIPTION: PA Department of Health Report BUREAU Comnonvjoalth of Pennsylvania Department of Health G - hdlU IK OP I N D U S T R I A L Joseph S h ilo n , M. D. Director H Y. G I E N E Report of SURVEY Asten-Hi 11 Manufacturing CompanyHenry & Roberta Avenues Philadelphia, Pennsylvania Prepared for: Vr. John McCormick Asten--Hill Mfg, Co* ^5 AHD 0000591 c o M M O N Y ^ LTri0' - ^ N N s YLv< *Nl (mm DEPARTMHEa rNrTi s bOu rFg HEALTH June 19, 1950 Mr. John McCormick Asten-Hill Mfg., Co. Henry <fe Roberts Ave. Philadelphia, Pennsylvania Dear Mr. McCormicks Submitted herewith is the report of survey made recently at your plant b y personnel of this Bureau. Thank you for your cooperation in making this study. The services of.this Bureau are available to you at all times. Very truly yours, ."i) % Joseph"Shilen, M.D., Director ireau of Industrial Hygiene AHD 0000592 * .BUREAU CofliDionweaj.tn o f P e n n s y l v a n i a Department of Health OF I N D U S T R I A L H Y G I E N E Report of Survey Asten-Hill Manufacturing Company Henry k Roberts Avenues Philadelphia, Pennsylvania At the request of the management of the above-named company, a survey was made during June 1950 to determine the efficiency of their dust collecting system. None. RECOMMENDATIONS DETAILED FINDINGS The company m s engaged in the manufacture of asbestos products and the dust collecting system was installed to remove the dust and fly arising from the carding and other operations peculiar to this type of industry. The dust-laden air is passed through a P a n g b o m unit, a Precipitron, and then water spray before being conditioned and recirculated. Since the company was desirous of ascertaining if the system was effective, atmosphere samples were taken at such places as would give an indication of the functioning of the system. From the accompanying table it can be seen that the dust concentration in the general atmosphere in the finishing room is muqfi lower than that in the atmosphere of the carding room. The percentage efficiency of the system can be estimated from the dust concentrations found in the main duct leading to the Fangbprn unit and the dust concentrations found at the end of the system (between the spray and fan).' This efficiency is approximately 99ji, which is very high and shows that such a system is extremely effective in removing dust of micro- soopio site. / In tho near future, a survey will be made of the entire plant to determine the dust concentrations in the atmosphere of tho working areas. AHD 0000593 Table 1 Sampling location Co.v--y.onv.-on1th of Pennsylvania Dopart-T.ont of Koulth 8UR?a u o f i n d u s t r i a l h y g i z n s Duat Concentrations Asten-Hill Manufacturing Company Henry 4-. Roberts Avenues Philadelohia, Pcnnsvlvania Duct concentration (millions of particles per ) cubic foot of air General atmosphere in carding room Between Pangborn unit and Precipitron 4.6 2.1 2.7 2.7 0.3 j& ; $ 0.6. \ Between Precipitron and water spray Between water spray and fan Finishing room, ' general atmosphere 0.7 0.3 1.2 \ 1.1 1.4. i j 0.9 1.8 2.1 i;4. Carding machine, near hood Picker, near hood l!ain duct to Pangborn unit 9.9. - 10.1 251.2 198.4 / June 19 1950 PC/* Surrey by: Prank J. Willard, Jr. Industrial Hygienist TT. H. Taylor Jr. Industrial Hygienist U. H. Green Chemist AHD 0000594