Document KRyk1XB2Z1px8r2EYpXvzX4KK
American Society of Heating and Ventilating Engineers Guide, 1924-25
better be taken from the Tables 96 to 102, which cover still and various
moving air conditions.
j
i HOW TO USE THE COMFORT CHART I In the Psychrometric Chart, dry bulb temperature is plotted as
abscissae and grains of moisture per pound of dry air as ordinates. The
maximum moisture which the air can hold at any temperature gives the
saturation or 100 per cent relative humidity curve. Relative humidities
between 0 and 100 per cent are given by a series of curved lines similar
to the saturation curve. The wet bulb temperatures for all atmospheric
conditions are given by a series of nearly parallel oblique lines. Effective
temperature is given by a series of oblique but not parallel lines which
approach being parallel to the wet bulb lines at high temperatures and
humidities, and dry bulb lines at low temperatures. The numerical
value of the wet and effective temperature lines is given by the dry bulb
temperature of their intersection with the saturation curve.
Dry bulb temperature is the true temperature of the air as determined
by an ordinary thermometer. It does not, however, accurately indicate a
I
person's feeling of warmth. It the humidity is high a person will feel
j
warmer at the same dry bulb temperature than he will if the humidity is
`
low.
.'
'
Wet bulb temperature is not the temperature of the air but that which a thoroughly wet body will attain if the air passes over it for a sufficient
length of time and with a high enough velocity. A person is not thoroughly
wet and hence does not react entirely in accordance with the wet bulb temperature. At high temperatures when the body is wet with perspira
tion, it reacts more nearly to wet bulb temperature while at low tempera
tures the body is comparatively dry and reacts more nearly in accordance
with the dry bulb temperature.
Effective temperature is an experimentally determined scale which
unlike the dry bulb, and wet bulb scales is a true measure of index of a
person's feeling of warmth in all combinations of temperature and
humidity. In other words with any given effective temperature a person
will always feel the same degree of warmth or coldness regardless of the
dry bulb or wet bulb temperature.
That range of effective temperatures over which 50 per cent of people t feel comfortable, namely 62 deg. effective temperature-to 69 deg. effective
temperature, is called the Comfort Zone.
That particular effective temperature at which a maximum number of
people feel comfortable is 64 deg. effective temperature and is called the
comfort line. While at rest in still air, 97 pier cent of all people are com
fortable at this temperature.
Tables 96 to 102 give the relation between dry and wet bulb tempera
tures, and effective temperature for still air, and various air velocities
up to 700 ft. per min.
Example 1.--Given dry bulb and wet bulb temperatures of 75 and 68 deg. First: what is the effective temperature? Second: is this condition warmer or cooler than 80 deg. dry bulb and 63 deg. wet bulb?
Answer.--The first condition is given by the intersection of the 75 deg. dry bulb line and the 68 deg. wet bulb line. The effective temperature is given by the numerical value of the effective temperature line, passing through this point and indicated by the
177