GE pushes to the limit on PCBs
Holding basins, activatad-carbon treatment are major additiors to capacitor plant cleanup drive to meet proposed EPA standard
Laic lut month the Environmental Protection Agency proposed stringent standard! for polychlorinated biphenyl! in waste water--zero discharge from man ufacturing procams and I part per bil lion (daily average) from nonprocess area*. Yet, Lucas P. Hart, Jr., general manager of General Electric's belea guered capacitor manufacturing plants at Hudson Falls and Fori Edward, N.Y., is
confident of meeting the standards. The two GE units are among 19 ca
pacitor plants throughout the U.S. that use some 20 million Ibs./year of PCBs as dielectric fluid to prevent electrical breakdown in the equipment they turn out. In addition, transformer manufac turers and Monsanto, the sole U.S. pro ducer of PCBs, will be ffcced with meet ing the standards, which were published In the July 23 Federal Register.
The two GE plants gained consider able attention when New York state's Dept, of Environmental Conservation or dered the company to reduce discharges of PCBs to zero by September 1976 after Ash in the Hudson River were found to oontain levels of the materials exceeding the Food and Drug Administration's 5 ppm. limit (CIV, Sept. 17, 1975, p. 19). OE is Aghting that order and is still awaiting Anal recommendations from the suite hearing examiner.
Previously, the company had obtained a permit from the state (in December 1974) permitting discharge of up to 30 Ibs./day of PCBs into the river. Then in
34 CHEMICAL WEEK August 4, 1976
August 1975 the state changed iu PCBs limit to 1.5 lbs./day after high levels of the materials were (bund in fish and in silt dredged from behind the Fori Ed ward dam by the Corps of Engineers.
The state has now accepted GE's plan for cleaning up the discharge from the two plants. Still at issue: GE's indemnity for damages and the extent to which the river bottom must be cleaned up.
Renovation Effort: GE has already re duced PCBs discharge to 12 oz./day, partly as a result of a $l2-million renova tion eltbri at the two plants, which are less than three miles apart on the Hudson River north of Albany. And $5 million will be spent on waste-water control that will reduce the discharge of PCBs to leu than I or./day.
The control problem doesn't seem too difficult at the Hudson Falls plant, where a dosed PCBs delivery system has been built and large industrial capacitors are Ailed by a closed manifold system.
But the Fori Edward plant, which consumes 80% of the 8 million Ibs./year used by the two plants, operates under more difficult conditions. The small ca pacitors made at the plant for lighting fixtures, air conditioners and small mo tors ire filled with 0.1-3 lbs. of PCBs. Pre viously, the capacitors were loaded into cases, which were flooded. Now an auto matic system Is used. And although it is not a closed system, Hart says, "We have very little loss ofPCBs now."
The capacitors are Ailed in two stages.
1
First, a vacuum is produced, then me chanical pumps flood-fill the units. Over flow PCBs run into a pit.
Much of the Hudson Falls cleanup has
resulted from reducing the number of discharge points from nine to one. GE found that most of the PCBs runoff was from old drainage and ventilation sys tems buried when the plant, which had been used to make paper boxes, was con verted to capacitor manufacture.
New Plans: Some cooling towers will be added to reduce use of river water. Impoundment basins will cut discharge to the river from about 1.8 million gai./day of treated water to 150,000. And an acti vated carbon treatment system will elimi nate the PCBs from the waste water.
The impoundment basins-400,000>gal. capacity at Hudson Falls, 1.8 million gal. at Fort Edward-will be 15-18 fl. deep and lined with bentonite. The basins will act as clarifiers. The waste water will then pass through a diatomaceoui earth prefil ter and flow downward through two 8-fthigh, IO-in.-diameter activated-carbon columns in series. Total contact time will be 45 minutes.
Robert Marquis, GE engineer in charge of the PCBs cleanup, estimates that 80,000 lbs./year of activated carbon will be consumed. GE will rent the acti vated carbon system from Calgon foe S 160,000/year. Calgon will run the unit for the first six months, train GE person nel and regenerate activated carbon.
"Lots of equipment suppliers have asked for samples of our wastes to see if they could clean them up, but none has been as good as the activated carbon sys tem," says Hart In a pilot-plant teat last year the Calgon system cut PCBs level in the effluent to about 0.0027 Ib./day.
Meanwhile, Han says, the days of PCBs are numbered. "Logic iso longer 'applies to this situation. We will be out of PCBs use by 1978," be adds.
' Hart maintains that PCBs are still tba **best material for the job and probably less of a health hazard than running the risk of Ares with some substitutes." OE has already shipped electrical equipment to Japan, which has banned PCBs, Atled with its own phthalate ester substitute, called Econol. And it will probably shun substitutes recently developed by some chemical companies (CIV. Dec. 10, 1975, p. 18). It is developing a new material, re portedly in the ester family, called only by the code number 1131.
And GE says its cleanup system should be able to operate as well no matter what PCBs substitute the company eventually turns to.