Document KRxZnBdZb5zLeZEarLL8rxvEw
Heaters, Water
101 New York
Park Ave. McDermott Water Heaters, Inc.
City
SOLD BY JOBBERS AND BOILER MANUFACTURERS
McDermott Water Heaters,
Inc., installed the first submerged water heater in New York City. Today McDermott Heaters are in stalled in buildings supplying hot water to over 48,000 apartments in the New York metropolitan area.
These heaters may be used as oil preheaters and converters for any usual adaptation.
We manufacture water heaters exclusively. We believe we can show them to be superior in quality and performance. We are prepared to meet price competition anywhere.
Complete information on request.
Table 2--McDermott In-Boiler Heaters
W ith steam a t 1 1-lb. pressure |[Using water from steam heating boiler as the heating medium fU sing 180 F. water as the heating medium Steam I Steam I
Table 1--McDermott Exterior Heaters and McDermott In-Tank Heaters
(crated), lbs.
W eight w ith shell
Capacity, Cals.
Pipe Con Dimensions nections. In. in Inches
ao
Coil Shell L D
*3 o
Zc
V .a a <J
=5 h
le 61 &
V 03
JT
||
""/a
1
5? 180 53 28C 54 37(1 55 465 56 56(1 57 65(1 58 740 59 840 510 920
110 165 220 275 330 385 440 495 550
77 2 116 2 154 2 193 2 231 2
270 2 308 2 347 2 385 2
21 2
21 2
2 1% 2 2 l'/4 21/2 2 1/2 2>A 2 IV7 2V2 22 3 22 3 22 3
30 42 54 66 78 90 102 114 126
8 8 8 8 8 8 8 8 8
3.14 4.71 6.2fi 7.85 9.42 10.99 12.56 14.13 15.70
78 $24.00 98 40.00 117 50.00 136 60.00 155 65.00 1/4 72.00 193 80.00 212 90.00 230 100.00
Cat. Size No.
4?" Cap. Gals.*
Tank Con.,
In.
Boiler Opening.
In.
List Price
V4103 V4I06 V4108 M42I0 M42I2
3 6 8 10 12
150 245 350 550 800"
IV4
!'/
l'/ 2 2
I'/4*4V4
174*4!/. 174-4!/,
3y3'/;
%*3'A
$30.00 50.00 66.67 100.00 116.67
Ratings based on 100 temperature rise in three hours, 180 F. boiler water in summer with supply at 75* F.. and 212 F. boiler water in winter with supply at 45* F.
Special lengtht take price of next larger size.
103 1100 104 148(1 105 1840 106 2220 107 2580 108 2950 109 3370 1010 3690
660 880 1100 1320 1540 1760 1980 2200
462 2 4 2 4
616 7 4 2 4
770 2 4 2 4
925 2'A 5 2/, 5
<A1078 2 5 i'/l 5
M1232 m 5
5
1386 3 6 3 6
1540 4 6 4 6
125 2775 126 3330 177 3885 128 4440 179 4995
1210 5550
1650 1980 2310 2640 2970 3300
1155 m 5 2'A 5 1386 3 5 3 5
1617 4 6 4 6 1848 4 6 4 6
2079 5 8 5 8 2310 5 8 5 8
83 1330 792' 555 2 4 2 4
84 1774 1056
740 7 4 2 4
85 2270 1320 925 l'/z 5 m 5
86 2662 1584 1110 I'/l 5 2/7 5
87 3106 #1848 1295 3 6 3 6
88 3550 1480 1460 4 6 4 6
56 16 68 16 80 16 92 16 104 16 116 16 128 16 140 16
18.64 25.12 31.40 37.68 43.96 50.24 56.52 68.80
405 105.00 459 135.00 513 216.00 567 258.00 621 300.00 675 350.00 729 400.00
783 450.00
84 19 96 19 108 19 120 19 132 19 144 19
47.10 628 415.00 56.52 697 460.00 65.94 766 505.00 75.36 835 550.00 84.78 904 595.00 94.20 973 640.00
54 13'/, 18.90 303 88.00 66 13/2 25.2 357 188.00 78 15/, 31.5 411 238.00 90 I3'/S 37.8 465 288.00 102 13'/, 44.1 519 338.00 114 13Vi 50.4 573 386.00
Gallons raised 130 F. in 3 hra. ||GaUons raised 100s F. in 3 hrs. Based upon 180 F. boiler water in summer with Bupply at 75 F. and 212 F. boiler water in winter with supply.at 45 F. fGalions raised 100* F. in 3 hra. Based on supply at 45 F. Use with circulating pump if heating medium is
water. {Write for discounts.
Table 3--McDermott Tankless-Instantaneous Water Heaters Using Water or Steam as the Heating Medium--Installed in Boilers or in Self-contained Shells
Size No......................................... V3 V4 V5 V6 V7 V8 MI0 MI2
In Cals, raised 40 lbs. .
Steam 130* F.
velocity 650 600 1000 3500 5500 7300 14000 17000
Boiler hourly
pressure*
In Cals, raised 40 lbs.
Water 100 F. velocity 455 560 700 2450 3850 5110 9800 11900
Boiler hourly
pressure*
Square feet of surface............... 10.5 13.65 16.80 19.95 23.1 26.25 50.24 54.95 Boiler opening, in...................... 14x15.5 14x15.5 Uxi5.5 I4x15J 14x15.5 14x15.5 3.75x12 3.75x12
Shell dimensions, in.................. 10* lOx lOx lOx lOx lOx I4x 14x
If self-contained, ft................... 3 4 5 6 7 8 10 12
L--length, ft............................... 3 4 5 6 7 8 10 12
W--width, in.............................. 15.25 15.25 15.25 15.25 15.25 15.25 11.5
11.5
Weight with shell, crated......... 198 248 298 348 398 448 810 880
Weight without shell, crated. . 45 52 59 66 73 80 170 180
No. of units in 1 able 2 of equal capacity?................................. 3V4I03 3V4104 3V4I05 3V4I06 3V4107 3V4108 3M42I0 3M42I2
List price with shell.................. $120.00 $150.00 $165.00 $190.00 $215.00 $240.00 $370.00 $410.00 List price without shell........... $90.00 $110.00 $125.00 $150.00 $175.00 $200.00 $300.00 $350.00
This McDermott Heater wu manufactured by us for Uu/U. S.
Government
'Maximum discharge temperature 30* F. less than boiler water temperature. Smaller boiler openings and greater efficiency in maintaining primary heat on transfer surface result from non-groupea coils. They are connected in series by piping contractors.
694
shell
|
Complete w ith r f"
*u
Heaters, Water
Parkinson Heater Corporation
Parkinson Tankless Submerged Water Heaters, Tempering Valves, etc.
11 West 42nd St., New York City
4105 N. Damen Ave., Chicago, 111.
Local Distributors in Principal Cities. Consult phone book or write
-ni/mn/SM PRODUCTS--Parkinson Tankless lvrx'i iioGli Submerged Water Heaters for do-
W-----A--T---E---R-- -- -- - - mestic water supply, designed to
eliminate storage tanks, insulation,
separate heater, extra flue, fittings,
piping and hook up at a very definite
savings in fuel costs. Holby Temper
ing Valves (write for details) for use
with water heaters to increase gallon
capacity and assure uniform tem
perature within 5 degrees and permit
continuous circulation.
Free Service--Without obligation,
our Engineering Department will submit
recommendations, layouts, or advice on
domestic hot water and piping require
ments.
One of the typical instaUatione
Send for list of users, actual case
Parkinson tn a fire tube boiler studies and circulars.
Officially approved by the Investigatin Committee of Architects and Engineers.
Guarantee--Parkinson Heaters are guaranteed to produce under normal con ditions a saving of from 30% to 70% of
fuel costs. All parts tested under 250 lbs. pressure.
How to Figure Heater Required
Tankless water heating cannot be figured by the customary method as used for tanks. Therefore the following method using the "Demand Unit" is used. This unit has been developed from the result of thousands of installations over six years.
Calculation of Demand Units Units
Installation No.
Comparative
Kitchen and bathroom.
Capacity
normal.................................... 10 Demand Standard
Water Pressure
Extra apartment bath, pri
Units Estimated Up 40 80
vate.........................................
3
Tank Size, to to to
Extra apartment bath, maid.
4
Gals.
40 80 120
Kitchen......................................
5
Lbs. Lbs. Lbs.
Cupboard kitchen....................
2
Bathtubs, normal....................
5
10
50 1 1 3
Separate shower.......................
5
20
90 3 3 3
Shower in tub...........................
1
30
120 3 3 6
Lavatories.......................
2 60 240 6 6 12
Club or institution showers... 25
120
480 12 12 12
Sinks (slop)...............................
3
160
600 12 18 20
Restaurant (hand washing)..
I
220
840 18 18 20
per seat 280
1080
20 30 30
Wash tubs, apt. laundry........
5'
360
1400
30 30 50
All other loads: the detail of
420
1680
30 50 50
equipment should be fur
480 1900 50 50 70
nished.
540
2150
50 50
70
Load on Boiler Steelflue type boiler--Due to increased efficiencies set up in the boiler it is safe to install PARKINSONS in boilers without additional radiation provided the boiler is ample for the heating load. For new boilers a factor of safety of 2 sq. ft. per demand unit may be figured. Cast-iron boilers require 4 sq. ft. radi ation for each demand unit.*
Water Temperature Line temperatures range from 135 ,
600 660 720 840 1000 1500 2000 2500
2400 2700 2900 3100 5400 6400 7000 9000
50 70 70 50 70 224 70 224 224 70 224 224 250 250 270
270 270 270
270 290 290 290 290 290
Note--Put the letter C after installation number if it is a cast-iron boiler.
Piping details furnished per request. To estimate the cost of piping same as hooking to tank.
to 165. but may be controlled within
15. For hotter water special heater is required. Holby Tempering Regulators are sup
plied for more uniform requirements built special for Parkinson Heater.
695
Construction--The Parkinson is protected
by Pat. No. 1,834,070 and operates on an ex clusive principle not to be confused with other heating coils. Supply tube and return tubes are sized to produce a rapid and constant flow of hot water. Heater is constructed of virtually pure copper, consisting
of heavy wall tubes and cast headers, brazed together, with copper flux at high tempera ture.
Installation--Heat ing unit is submerged in boiler water j ust be low water line of prac tically any low pressure boiler. Simple to in stall. Does not multilate the boiler as only one incision is required. Unit takes up no usable space in cellar. Oper ates on any fuel, auto matic or hand fired.