Document KR7rGEgbDYDdXpJjmGxGmnBMX
TABLE 29-F EXHAUST HOODS FOR GRINDER AND CUTOFF WHEELS
Wheel
Good Enclosure
Poor Enclosure
Diameter (in )
Width (m)
Duct Diameter
(in)
Cfm
Duct Diameter
(in)
Cfm
Up to 9 Over 9 to 16 Over 16 to 19 Over 19 to 24 Over 24 to 30
Over 30 to 36
I'/a
2 3 4 5
6
3
220 3'/a
330
4 390 5 600
4'/a 500 5'/a 750
5 610 6 920
6
880 7
1,300
7
1,200
8
1,600
Note These figures should be considered adequate only for nontoxic metals such as gray iron Where toxic metals or alloys are encountered, these types of hoods are not adequate for control
From American Standard Z43 J, Ventilation Control of Grinding, Polishing, and Buffing Operations
polishers, with the polishing head only an inch or so in diameter, can be controlled by placing a tapered rectangular hood at each station The lace opening may be approxi mately 4 X 8 in , with a 3-in flange on four sides
To permit adjustment of the hood, there can be a section of flexible metal pipe back of the hood, or swivel and telescopic connection pieces can be inserted
A branch duct 4 in in diameter can handle 350 cfm at about 4000 fpm Ducts smaller than 4 in in diameter are unwise because the friction loss in flexible piping smaller than 4 in in diameter becomes prohibitive with a 4000 fpm duct velocity
The low-volume, high-velocity exhaust system is a relatively new design for con trolling dust from portable hand tool and machining operations Capture velocities are high but the exhaust volume is low be cause air is exhausted directly at the point of dust generation by means of close-fitting, custom-made hoods and light-weight plastic hoses
More details are given in the American Con ference of Governmental Industrial Hy gienists' Industrial Ventilation--A Manual ofRecommended Practice
Woodworking
The woodworking industry was one of the first to recognize the value of local exhaust
systems They are applied almost universally in production shops, their benefits being better housekeeping, improved working conditions, and decreased fire hazard Many states have specific codes covering this type of ventilation, and these, of course, should be complied with
Higher cutting speeds developed for wood working machinery have led to higher pro duction, which in turn means more shavings, chips, and dust Exhaust ventilation must be increased correspondingly In fact, with some of the newer machines, more air should be exhausted than is called for by the codes, which often lag behind technological prog ress
The ACGIH Industrial Ventilatton Manual gives recommended exhaust volume and branch duct diameter for average-sized wood working machines, together with excellent drawings of typical hoods Exhaust volume will vary with cutting speeds, length of cutter heads, length of sander drums, and diameter of saws In general, saws require 4- to 6-in , and occasionally 8-in branches, most cutting heads, a 5-in branch
Conveying velocities are generally 4000 fpm m branches and 3500 m main ducts Where exhaust air is used to convey material pneumatically, as, for example, after it has been through a hog, or when it is picked up from the discharge of a dust arrester, veloci ties of 4500 to 5(M)0 fpm are needed, with an
885