Document KR2a68LD9VQLO9k6wMJEvyaJo
FtKSONAL AND CONFIDENTIAL
INTERNAL CORRESPONDENCE
CHEMICALS AND PLASTICS
TO (NAME)
COMPANY
location
Mr. R. N. Wheeler SOUTH CHARLESTON PLANT
P. O. BOX 471, TEXAS CITY. TEXAS 77590
August 6, 1975
Mr. M. E. Elsenhour Mr. J. F. Erdmann
Mr. R. L. Frantz Mr. J. B. Leverton Mr. W. P. Nlckles Mr. R. E. Peele Mr. K. E. Ross Mr. R. W. Sesler I. H. File
SUBJECT
VCM Fenceline V______
Dear Nick:
Attached per your request are fenceline data collected monthly, March through July 1975. Six sampling points ar^p designated on the map along Highway 146 east of the Regulated Area. Wind direction and unit operating capacities are Indicated.
All represent near eight-hour time weighted average concentrations. Two samples were above the permissible level. Two others were above the action level.
Additional data have been recorded at other set points around the Regulated Area which are not on the fenceline. These are not reported herein.
Please contact me If there are questions.
Very truly yours
ec Attachment
D. E. Deese Industrial Hygiene Director
ucc
033893
lNUUblKIAL HTtaltNt UtRARTML!
< TEXAS CITY PLANT August 5, 1975
*
^ VCM PERIMETER MONITORING
FENCELINE fifiOl
-pie /'Oint
3-3-75
3-4-75
13
14 15 0.80
16 1.08
17 18 0.10
Wind
East
ENE
F.owipment Capaciti es:
Susp,
67%
67%
N/Solv. -0-
-0-
Solv. 100%
100%
3-27-75
0.01 0.02 -00;02 0.02 SE
4-7-75 0.29 0.58 1.23 0.44 .0.02
East
-0-0-
100%
-0-050%
4-11-75
0.04 0.43
NE
5-19-75
0.06 0.04 0.03 0.03 0.21 0.02
SE
6-6-75
-0-0-00.05 -0-0SSE
-0- 67% 67%
-0- -0- , 100% 50% 10% -0-
6-16-75 -0-0-
SSE
7-18-1
-0-0-0-0-0-0SSE
67% 100%
-o- :
67% 100%
10%