Document KObLJq4VDk14Dgd4eKq4954N

Document No. R8QP-2015 RO Effective Date 4/19/2016 EPA Region 8 402c Renovation, Repair, and Painting Rule Inspection List 1 OF 6 BASIC INSPECTION INFORMATION Inspection Date/Time: 3/9/2023 11:45 ICIS #: 3601516615 Presented EPA credentials to person in charge and explained purpose and scope of inspection Inspection Entry: Entry Permitted. Entry Denied. (Provide details in notes.) NOI signed by: Kirk (NFI) Regulated Entity Firm Name: Owner Name & Contact Information: Creative Landscape & Design Inc. Scott Hopper 719 491-0891 DBA or Former Names: 719 3929598 (Cell) Firm Address + Contact Information (phone, website, email): 6810 Rolling View Drive Colorado Springs, CO 80925 Additional Representatives: Kirk (site representative) # Employees: Unknown # Projects/Year: Unknown Type of job observed (include permit information, if available): Exterior Painting Prep and interior remodel. Per Kirk, this will be a remodel for rental. Is the firm certified? Yes No Was a certified renovator assigned? Yes No Certificate(s) on site? Yes No Name(s) of renovator(s): Address of Property: Site Information Owner Name & Contact Information: 84 Baylor Street Pueblo, CO 81005 Contractor Scott Hopper 719 491-0891 or 719 3929598 (Cell) Building Type: single family residence multi-family residence child-occupied facility other Year Built: 1959 Is the building occupied? Yes No Unknown If Yes, age of residents: Person(s) interviewed during inspection: Name & Title: Contact Information: Document No. R8QP-2015 RO Effective Date 4/19/2016 EPA Region 8 402c Renovation, Repair, and Painting Rule Inspection List 2 OF 6 Facility Name: Creative Landscape & Design Inc. ICIS #: 3601516615 Work Practice Requirements What type of project is it? Interior Exterior Both (e.g. window replacement) Is RRP work involved? Yes No Is RRP work in progress? Yes No All Projects If RRP work is in progress, check the following: Comments: Are Warning Signs Posted? Are prohibited practices being used? Is waste properly contained? Are windows and doors in the work area closed and/or doors being used as an entrance covered with plastic? Is the floor in the work area covered with tapeddown plastic at least 6 ft. beyond the perimeter of surfaces undergoing renovation? Are all ducts opening in the work area covered with taped-down plastic? Are windows and doors within 20 ft. of the renovation closed? Are doors that are in use during the job covered with plastic, allowing workers to pass through while confining dust and debris? Is the ground covered with plastic sheeting extending 10 ft beyond the perimeter of surfaces undergoing renovation? Yes No Unknown Yes No Unknown Yes No Unknown Interior Projects Yes No Unknown Yes No Unknown Yes No Unknown Exterior Projects Yes No Unknown Yes No Unknown Yes No Unknown If the work is complete: Cleaning Requirements Comments: Is the work area cleaned so that no dust, debris, or residue remains? Are all paint chips and debris collected and sealed in a heavy-duty bag? Did a certified renovator perform a visual inspection and cleaning verification? (If yes, obtain documentation) Yes No Unknown Yes No Unknown Yes No Unknown Work in Progress Work in Progress Basic Recordkeeping Requirements Firm provided the following records (check all that apply): Determination that lead-based paint present on the components affected by the renovation The owner or tenant's signed acknowledgment of receipt of the EPA-approved lead hazard pamphlet Training certificate(s) for certified renovator(s) Documentation of training provided to uncertified workers Documentation of compliance with the requirements of RRP Work Practice Standards Document No. R8QP-2015 RO Effective Date 4/19/2016 EPA Region 8 402c Renovation, Repair, and Painting Rule Inspection List 3 OF 6 Facility Name: Creative Landscape & Design Inc. ICIS #: 3601516615 Inspection Summary - Inspector Comments and Findings Inspector Maksimuk observed exterior prep/painting in progress at location. No lead-safe practices were in place. Paint chips were scattered on the ground on the entry area and front lawn. Several workers were inside the residence performing a kitchen remodel and extensive drywall repairs/replacement. Maksimuk also observed painted rake boards (trim) that appeared to be scraped or sanded. Rain gutters were laying on the ground. Maksimuk was approached by the site representative, Kirk. Maksimuk ID'd self and Kirk stated this project was a remodel by the owner contractor, Scott Hopper, owner of Creative Landscape & Design. Kirk stated Mr. Hopper was in Mexico, on vacation. Maksimuk did not enter the house due to a dusty environment. When asked, the site rep (Kirk) was not familiar with the RRP Rule and lead-safe work practices. Kirk stated he will clean up the paint chips. There were numerous paint chips on the entry area and lawn. Facility Name: Creative Landscape & Design Inc. Photo #: Subject P3090676 Front of House - Across Street PHOTO LOG Time 12:49 P3090677 Close-up Front of House With Gutters 01:00 P3090679 Scaffolding - with Full View Ladder 01:19 P3090680 Scaffolding with Upper area 01:19 P3090681 Paint Chip on Ground from Eave areas 01:19 P3090682 Close-up - Paint Chips on Ground 01:20 ICIS #: 3601516615 Notes Date: 03/09/2023 P3090677 5 OF 6 Document No. R8QP-2015 RO Effective Date 4/19/2016 EPA Region 8 402c Renovation, Repair, and Painting Rule Inspection List 6 OF 6 Facility Name: Creative Landscape & Design Inc. ICIS #: 3601516615 RECORD OF REVIEW Inspector Inspector who prepared report: Christopher Maksimuk Signature: Maksimuk, Christopher Reviewed by: Kristin Jendrek Digitally signed by Maksimuk, Christopher Date: 2023.05.09 10:01:43 -06'00' Reviewer Date report completed: Signature: Digitally signed by KRISTIN JENDREK Date: 2023.05.18 21:37:03 -06'00' Date: 05/18/2023 1/3/2020 11:04 AM