Document KJyb2O8M1Ox8LbN0LOwg4eKDr
FILE NAME: Scotts (SCTS)
DATE: 1977 July 19 DOC#: SCTS023
DOCUMENT DESCRIPTION: Material Safety Data Sheet - Expanded South Carolina Vermiculite
PLAINTIFF'S EXHIBIT
SCO-16
c 618136^
DATS:
U.S. DEPARTMENT OF LABOR July 19, 1977 Occupational Safety and Health Administration
MATERIAL SAFETY BATA SHEE
Required under U SDL Safety and Health Regulations for Ship Repairing' Shipbuilding, and Shipbreakir.g (29 CFR 1915. 1916, 1917)
M A N U F A C T U R E R 'S N A M E W. R. G ra c e & C o m p a n y
SECTION 1
--
.
EMERGENCY TELEPHO NE NO.
1 -6 1 7 -8 7 6 -1 4 0 0
X 457
A O O R E S S (N u m b e r. S tr e e t, C it y . S t a t e . a n d '/ .IP C o d e ) 6 2 W h itte m o r e A v e n u e - C a m b r id a e . m a C H E M IC A L N A M E A N D 5 Y N O N V M S
E x D a n d e d S o u th C H E M IC A L F A M IL Y
C a r o lin a . V e r m ic u lit e
M a g n e s iu m . A l u m i n a s ilic a t if i_ M in e r a l.
02140
Q u a lity A s s u ra n c e j TRADE NAME AND SYNONYMS
M anager
~
`I n d u s t r i a l
| FO RM ULA
.
V e rm
ic u lite - S iz e
S3 &
t( M c r ,C a ,K ) - ( A l, F e , M q ) - ( S i, A l) (0 )
(O H ).
#4
-H- r.
SECTION II - HAZARDOUS INGREDIENTS
,
Contains a naturally occurring mixture or amphibole trantairttnant?;-- Uuzubleiide and
tremolite. The predominant morphology of the contaminant is platy Cnon-fibrous)j
OSHA Regulation 1910.1001 defines tremolite as asbestos. Less than 5% of the con
taminant is in a form which can be fibrillated by physical handling to release air
borne "asbestos fibers". Regulation 1910.1001 places a limit of 2 "asbestos fibers"/
cc; 8 hour time weighted average and a maximum of 10 "asbestos fibers"/cc at any one
time for airborne fiber exposure.
The physical handling given to expanded vemiculite can release both airborne fibers and nuisance dust. Extensive sampling of a wide variety of work stations has shown that airborne fiber levels are substantially lower than the Regulation 1910.1001 limits for permissible exposure.
B O tL IN G P O IN T ( r .) V A P O R P R E S S U R E (Rim Hg.) V A P O R D E N S IT Y (A IR -1 ) S O L U B IL IT Y in w a t e r appearanceanqoo or
SECTION 111 - PHYSICAL DATA
Free
MA ... MA
' SPECIFIC G R A V IT Y (H ,0 1 )
1 ... -
.............................. -
i PERCENT. V O L A T ILE 1 (%) V O L U M E
MB
i E V A P O R A T IO N R A T E
JA
i(
slight, 1 _if any_'Bulk Density., lbs./c. f.
flowing dark brown to tan colored particles.
NA
m
NA
5-7
SECTION IV - FIRE AND EXPLOSION HAZARD DATA NOT Ap p l i c a b l e
F L A S H p o i n t (M <stnod used)
e x t in g u is h in g m e d ia
IiF l a m m a b l e l i m i t s
i __ bf!___ i___ Uel
i ..
1
_
S P E C IA L F IR E F IG H T IN G P R O C E D U R E S l
ii
-
WRG 0676
I U N U S U A L F IR E A N D E X P L O S IO N H A Z A H O S
1
PAGE (1)
(Comir.usd on reverse side)
Form OSHA-20
Rev. M ay 72
The information contained herein is based on knowledge believed to be reliable
but W.R. GRACE fi CO. MAKES NO WARRANTIES, EXPRESS OR IMPLIED, AS TO THE ACCURACY OR
ADEQUACY THEREOF. Nothing herein excuses the recipient hereof from such duties
as shall be imposed by the Occupational Safety and Health Act of 1970 and regula
tions issued pursuant thereto.
r 'i
i
THRESHOLD l im it v a l u e
SECTION V HEALTH HAZARD DATA Dust respirable fraction 5 nwrro/M . Total dust 15 mqm/M
E N C V A N D FIR S T A IO P R O C E D U R E S
NA
S T A B IU TV
u n sta b le-
SECTION V I - R E A C TIV ITY D A TA
j C O N D IT IO N S TO A V O ID
NOT APPLICABLE
STABLE in c o m p a T A B i l i T V (Materials to avoid)
H A Z A R D O U S D E C O M P O S ITIO N P R O D U C TS
HAZARDOUS P O L Y M E R IZ A T IO N
MAV OCCUR W IL L N O T OCCUR
"
--
i
| C O N D IT IO N S TO A V O ID
'
___;|_______11-_-_--_--_-_--_--_-_--_--_-_--_--_--_-_--_--_-_--_--_-_--_--_-_--l-_--_-_--____________
|
|
-
SECTION V II - SPILL OR LEAK PROCEDURES
STEPS T O BE T A K E N IN C ASE M A T E R IA L IS R E L E A S E D O R S PILw SO
,
Dampen slightly, or use other techniques which control airborne dust within the
limits of Section V above.
_______
V .A S T E D IS P O S A L M E T H O O
.
.
_____________________ Use disposal techniques wnich control airborne dust wtthin
the TLV limits of Section V above.
SECTION V lll - SPECIALPRO TECTIO N INFOR M ATIO N
Respiratory Protection: If TLV is exceeded, use disposal respirator, Type TC-21C-132; 3M ? 8710 or similar disposable or reusable respirator.
SECTION IX - SPECIAL PRECAUTIONS PRECAUTIONS TO SE TAKEN IN HANDLING AND 5 'S S -
roVrsER PRECAUTIONS
.
............. ........................................ --............................ ..-- -- i
PAG I 12!
(VP 1 * lO.a-UJ
t
W R G 1061
...... Form OSHA-20
Rev. M ay 72