Document KJvk1Np2gEVKnRJ79vGozjnno
226
CHAPTER 10 ,
1958 Guide \
the appropriate limits of relative humidity. Only average permeabilities (or permeances) are measurable directly in practical tests. However, if several average permeabilities, at different relative humidities are known, *" and can be plotted as.for.the wet-cup and dry-cup tests shown in Fig. 3, it is possible to construct, by trial and error, a spot permeability curve which will satisfy the condition that the average height of the curve between the appropriate limits for each test must equal the value found in each test. Separate curves are required for each temperature so that a large: number of permeance cup teste would be required to cover a range of con
ditions of both temperature and humidity.
Experience to date shows that the effect of temperature is quite moderate and, for some purposes, differences in temperature at which tests are run
Fig. 3. Relation between Dry and Wet Cup Tests and the Spot Permeability for a Material such as Wood
may be ignored. Corrections for temperature have been made wiAV) some success by the use of an equation based on activation energy6 which..;. states:
fA -- Hoe BT
where, in appropriate units,
iu, = permeability at T =
R = gas constant
E = activation energy e = Naperian base of logarithms = 2.718
-tl-'
T = absolute temperature.
TT,;
Through the use of this equation, spot permeability curves for a variety;';(fe
temperatures can be constructed from a curve for one temperature, PjSat. vided only that two teste at different temperatures can be run, from whK E, the activation energy, can be evaluated. In this way it becomes P
Moisture in Building Construction '
'227
sible to describe the permeability of a material reasonably completely from the results of as few as five single teste at carefully selected conditions.
No method has yet been found, other than by direct testing for a particu lar set of conditions, of predicting the effective permeabilities for conditions of temperature gradient along with a humidity (or vapor pressure) gradient, from data obtained under other conditions, even though this is the general situation in practice. A very considerable amount of information is available on the permeances and permeabilities of various materials, but these are frequently obtained at different conditions so that the results cannot be compared directly, nor do. they often give a coverage of a range of conditions to permit construction of basic curves of spot permeability or permeance.
Since dry-cup and wet-cup tests are much easier to carry . out than teste at intermediate humidities, many of the data available have been obtained in this way. In the absence of data obtained from teste dupli cating the conditions of temperature and relative humidity in service the permeance of a piece of material may be judged adequately for many pur poses if it is tested by both dry and wet methods. It is obvious that any statement of permeance of a specimen should include the conditions of test.
Method of test E96-53T of the American Society for Testing Materials describes procedures for testing for water vapor transmission of materials in sheet form under five different test conditions. These include the drycup and wet-cup methods, based on 50 percent relative humidity outside the cup, at either 73.4 or 90 F, and a fifth condition at an elevated tempera ture of 100 F. with relative humidities of 0 and 90 percent on either side of the sheet. Standard T448m-49 of the Technical Association of the Pulp and Paper Industry covers the determination of water vapor transmission of paper and paperboard, and calls for the dry-cup method at 73.4 F., based on 50 percent relative humidity outside the cup.
tJnfortunately, there is no general agreement as yet to report results as coeliiMente of permeance, or of permeability where appropriate, as adopted in this chapter, or to use the same basic units. Test data are frequently reported m terms of weight transmitted per (unit area) (unit time). Such
ata may be called water vapor transmission data or WVT data and values are either high or low depending on the difference of vapor pressure chosen
r the test. When this difference is known, WVT data can be converted
?are being taken if conversion of the basic units (weight, a and time) is also required. The following formula applies:
where,
Permeance = --WV---T---r-a--t-i-n- gAp
(g)
rat,in(5 = weight of vapor transmitted, grains per (sq ft) (hour).
n__
~ vaPor pressure difference in the test, in inches of mercury.
Permeance is expressed in perms.
useTdabulenit2 Pr?en*'s the conversion factors applicable to the commonly
building m f-
m.ethods. Table 1 presents some, data on typical
aDDlinahu
lowing, in each case, the source and method and, where
Wate 'the thlckness tested.
147. May*24^i8U*^*n PaPers are listed in Federal Specifications UU-P-
> 1948, according to water vapor resistance required as: